메뉴 건너뛰기




Volumn 130, Issue 4, 2010, Pages 435-442

A new cochlear implant electrode design for preservation of residual hearing: A temporal bone study

Author keywords

Cochlear implant; Electrode array; Residual hearing; Round window approach; Temporal bone

Indexed keywords

ARTICLE; COCHLEA PROSTHESIS; DEVICE; ELECTRODE; ELECTRODE ARRAY; HUMAN; HUMAN TISSUE; PRIORITY JOURNAL; RATING SCALE; SURGICAL INJURY; SURGICAL TECHNIQUE; TEMPORAL BONE;

EID: 77950293030     PISSN: 00016489     EISSN: 16512553     Source Type: Journal    
DOI: 10.3109/00016480903283733     Document Type: Article
Times cited : (37)

References (20)
  • 1
  • 2
    • 0031934465 scopus 로고    scopus 로고
    • Speech recognition of hearing-impaired listeners: Prediction from audibility and the limited role of high-frequency amplification
    • Ching TYC, Dillon H, Byrne D. Speech recognition of hearing-impaired listeners: prediction from audibility and the limited role of high-frequency amplification. J Acoust Soc Am 1998;103:1128-1140
    • (1998) J Acoust Soc Am , vol.103 , pp. 1128-1140
    • Ching, T.Y.C.1    Dillon, H.2    Byrne, D.3
  • 3
    • 0031876497 scopus 로고    scopus 로고
    • High-frequency audibility: Benefits for hearing-impaired listeners
    • Hogan CA, Turner CW. High-frequency audibility: benefits for hearing-impaired listeners. J Acoust Soc Am 1998;104:432-441
    • (1998) J Acoust Soc Am , vol.104 , pp. 432-441
    • Hogan, C.A.1    Turner, C.W.2
  • 4
    • 33846991930 scopus 로고    scopus 로고
    • Preservation of low frequency hearing in partial deafness cochlear implantation (PDCI) using the round window surgical approach
    • Skarzynski H, Lorens A, Piotrowska A, Anderson I. Preservation of low frequency hearing in partial deafness cochlear implantation (PDCI) using the round window surgical approach. Acta Otolaryngol 2007;127:41-48
    • (2007) Acta Otolaryngol , vol.127 , pp. 41-48
    • Skarzynski, H.1    Lorens, A.2    Piotrowska, A.3    Anderson, I.4
  • 7
    • 2942719113 scopus 로고    scopus 로고
    • Combining acoustic and electrical speech processing: Iowa/Nucleus hybrid implant
    • Gantz BJ, Turner C. Combining acoustic and electrical speech processing: Iowa/Nucleus hybrid implant. Acta Otolaryngol 2004;124:344-347
    • (2004) Acta Otolaryngol , vol.124 , pp. 344-347
    • Gantz, B.J.1    Turner, C.2
  • 8
    • 33750321366 scopus 로고    scopus 로고
    • Temporal bone results and hearing preservation with a new straight electrode
    • Lenarz T, Stover T, Buechner A, Paasche G, Briggs R, Risi F, et al. Temporal bone results and hearing preservation with a new straight electrode. Audiol Neurootol 2006;11 (Suppl 1):34-41.
    • (2006) Audiol Neurootol , vol.11 , Issue.SUPPL. 1 , pp. 34-41
    • Lenarz, T.1    Stover, T.2    Buechner, A.3    Paasche, G.4    Briggs, R.5    Risi, F.6
  • 9
    • 33750286196 scopus 로고    scopus 로고
    • Combined electroacoustic stimulation in conventional candidates for cochlear implantation
    • James CJ, Fraysse B, Deguine O, Lenarz T, Mawman D, Ramos A, et al. Combined electroacoustic stimulation in conventional candidates for cochlear implantation. Audiol Neurootol 2006;11(Suppl 1):57-62.
    • (2006) Audiol Neurootol , vol.11 , Issue.SUPPL. 1 , pp. 57-62
    • James, C.J.1    Fraysse, B.2    Deguine, O.3    Lenarz, T.4    Mawman, D.5    Ramos, A.6
  • 10
    • 34247640719 scopus 로고    scopus 로고
    • Quality control after insertion of the nucleus contour and contour advance electrode in adults
    • Aschendorff A, Kromeier J, Klenzner T, Laszig R. Quality control after insertion of the nucleus contour and contour advance electrode in adults. Ear Hear 2007;28 (2 Suppl):75S-79S.
    • (2007) Ear Hear , vol.28 , Issue.2 SUPPL.
    • Aschendorff, A.1    Kromeier, J.2    Klenzner, T.3    Laszig, R.4
  • 11
    • 33750333181 scopus 로고    scopus 로고
    • The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes
    • Escudé B, James C, Deguine O, Cochard N, Eter E, Fraysse B. The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes. Audiol Neurootol 2006;11(Suppl 1):27-33.
    • (2006) Audiol Neurootol , vol.11 , Issue.SUPPL. 1 , pp. 27-33
    • Escudé, B.1    James, C.2    Deguine, O.3    Cochard, N.4    Eter, E.5    Fraysse, B.6
  • 12
    • 0037336982 scopus 로고    scopus 로고
    • Comparative study of cochlear damage with three perimodiolar electrode designs
    • Eshraghi AA, Yang NW, Balkany TJ. Comparative study of cochlear damage with three perimodiolar electrode designs. Laryngoscope 2003;113:415-419
    • (2003) Laryngoscope , vol.113 , pp. 415-419
    • Eshraghi, A.A.1    Yang, N.W.2    Balkany, T.J.3
  • 13
    • 33750366859 scopus 로고    scopus 로고
    • Ipsilateral electric acoustic stimulation of the auditory system: Results of long-term hearing preservation
    • Gstoettner WK, Helbig S, Maier N, Kiefer J, Radeloff A, Adunka OF. Ipsilateral electric acoustic stimulation of the auditory system: results of long-term hearing preservation. Audiol Neurootol 2006;11(Suppl 1):49-56.
    • (2006) Audiol Neurootol , vol.11 , Issue.SUPPL. 1 , pp. 49-56
    • Gstoettner, W.K.1    Helbig, S.2    Maier, N.3    Kiefer, J.4    Radeloff, A.5    Adunka, O.F.6
  • 14
    • 33746822371 scopus 로고    scopus 로고
    • Residual hearing conservation and electro-acoustic stimulation with the Nucleus Contour Advance cochlear implant
    • Fraysse B, Macías AR, Sterkers O, Burdo S, Ramsden R, Deguine O, et al. Residual hearing conservation and electro-acoustic stimulation with the Nucleus Contour Advance cochlear implant. Otol Neurotol 2006;27: 624-633
    • (2006) Otol Neurotol , vol.27 , pp. 624-633
    • Fraysse, B.1    MacÍas, A.R.2    Sterkers, O.3    Burdo, S.4    Ramsden, R.5    Deguine, O.6
  • 15
    • 66249090866 scopus 로고    scopus 로고
    • Results of partial deafness cochlear implantation using various electrode designs
    • Skarzyński H, Lorens A, Piotrowska A, Podskarbi-Fayette R. Results of partial deafness cochlear implantation using various electrode designs. Audiol Neurootol 2009;14 (Suppl 1):39-45.
    • (2009) Audiol Neurootol , vol.14 , Issue.SUPPL. 1 , pp. 39-45
    • Skarzyński, H.1    Lorens, A.2    Piotrowska, A.3    Podskarbi-Fayette, R.4
  • 16
    • 40949150331 scopus 로고    scopus 로고
    • Outcomes of treatment of partial deafness with cochlear implantation: A DUET study
    • Lorens A, Polak M, Piotrowska A, Skarzyński H. Outcomes of treatment of partial deafness with cochlear implantation: a DUET study. Laryngoscope 2008;118:288-294
    • (2008) Laryngoscope , vol.118 , pp. 288-294
    • Lorens, A.1    Polak, M.2    Piotrowska, A.3    Skarzyński, H.4
  • 17
    • 33748368281 scopus 로고    scopus 로고
    • Surgical aspects of cochlear implantation: Mechanisms of insertional trauma
    • Roland PS, Wright CG. Surgical aspects of cochlear implantation: mechanisms of insertional trauma. Adv Otorhinolaryngol 2006;64:11-30.
    • (2006) Adv Otorhinolaryngol , vol.64 , pp. 11-30
    • Roland, P.S.1    Wright, C.G.2
  • 18
    • 34548406424 scopus 로고    scopus 로고
    • Cochlear implant electrode insertion: The round window revisited
    • Roland PS, Wright CG, Isaacson B. Cochlear implant electrode insertion: the round window revisited. Laryngoscope 2007;117:1397-1402
    • (2007) Laryngoscope , vol.117 , pp. 1397-1402
    • Roland, P.S.1    Wright, C.G.2    Isaacson, B.3
  • 19
    • 33750367368 scopus 로고    scopus 로고
    • Comparison of round window and cochleostomy approaches with a prototype hearing preservation electrode
    • Briggs RJS, Tykocinski M, Xu J, Risi F, Svehla M, Cowan R, et al. Comparison of round window and cochleostomy approaches with a prototype hearing preservation electrode. Audiol Neurootol 2006;11(Suppl 1):42-48
    • (2006) Audiol Neurootol , vol.11 , Issue.SUPPL. 1 , pp. 42-48
    • Briggs, R.J.S.1    Tykocinski, M.2    Xu, J.3    Risi, F.4    Svehla, M.5    Cowan, R.6
  • 20
    • 4644219721 scopus 로고    scopus 로고
    • Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: A histologically controlled insertion study
    • Adunka O, Unkelbach MH, Mack M, Hambek M, Gstoettner W, Kiefer J. Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: a histologically controlled insertion study. Acta Otolaryngol 2004;124:807-812
    • (2004) Acta Otolaryngol , vol.124 , pp. 807-812
    • Adunka, O.1    Unkelbach, M.H.2    MacK, M.3    Hambek, M.4    Gstoettner, W.5    Kiefer, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.