메뉴 건너뛰기




Volumn 25, Issue 4, 2009, Pages 1865-1868

Some reasons to build a new laser doppler flowmeter to monitor microvascular blood flow

Author keywords

Depth and volume discrimination; Laser doppler flowmetry; Skin microcirculation

Indexed keywords

BIOINFORMATICS; BIOMECHANICS; BIOMEDICAL ENGINEERING; BIOPHYSICS; BLOOD; BLOOD VESSELS; CLASSIFIERS; DOPPLER EFFECT; FLOW MEASUREMENT; FLOWMETERS; MEDICAL PHYSICS; MICROCIRCULATION;

EID: 77950169517     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03882-2_495     Document Type: Conference Paper
Times cited : (3)

References (32)
  • 2
    • 33748747207 scopus 로고    scopus 로고
    • Mandal A (2006) Burn wound depth assessment - is laser Doppler imaging the best measurement tool available?. Int. Wound J., 3:138-143
    • Mandal A (2006) Burn wound depth assessment - is laser Doppler imaging the best measurement tool available?. Int. Wound J., 3:138-143
  • 3
    • 0032212312 scopus 로고    scopus 로고
    • Multichannel laser-Doppler probe for blood perfusion measurements with depth discrimination
    • Liebert A, Leahy M, Maniewski R (1998) Multichannel laser-Doppler probe for blood perfusion measurements with depth discrimination. Med. Biol. Eng. Comput., 36:740-747
    • (1998) Med. Biol. Eng. Comput , vol.36 , pp. 740-747
    • Liebert, A.1    Leahy, M.2    Maniewski, R.3
  • 6
    • 77950116782 scopus 로고    scopus 로고
    • Special issue on laser Doppler flowmetry for microcirculation monitoring. Technology and Health Care (1999), 7, nos 2-3
    • Special issue on laser Doppler flowmetry for microcirculation monitoring. Technology and Health Care (1999), vol. 7, nos 2-3
  • 7
    • 0026626319 scopus 로고
    • Tissue perfusion monitoring and imaging by coherent light scattering. Bioptics: Optics in Biomedicine and Environmental Science
    • Nilsson G, Jakobsson A, Wardell K (1991) Tissue perfusion monitoring and imaging by coherent light scattering. Bioptics: Optics in Biomedicine and Environmental Science, SPIE 1524:90-109
    • (1991) SPIE , vol.1524 , pp. 90-109
    • Nilsson, G.1    Jakobsson, A.2    Wardell, K.3
  • 9
    • 0022599420 scopus 로고
    • Blood flow in the skin of the foot related to posture in diabetes mellitus
    • Rayman G, Hassan A, Tooke J.E (1986) Blood flow in the skin of the foot related to posture in diabetes mellitus. Brit. Med. J., 292:87-90
    • (1986) Brit. Med. J , vol.292 , pp. 87-90
    • Rayman, G.1    Hassan, A.2    Tooke, J.E.3
  • 11
    • 4544358272 scopus 로고    scopus 로고
    • Spectral components of laser Doppler flowmetry signals recorded in healthy and type 1 diabetic subjects at rest and during a local and progressive cutaneous pressure application: Scalogram analyses
    • Humeau A, Koïtka A, Abraham P, Saumet J L, L'Huillier J P (2004) Spectral components of laser Doppler flowmetry signals recorded in healthy and type 1 diabetic subjects at rest and during a local and progressive cutaneous pressure application: scalogram analyses, Phys. Med. Biol., 49:3957-3970.
    • (2004) Phys. Med. Biol , vol.49 , pp. 3957-3970
    • Humeau, A.1    Koïtka, A.2    Abraham, P.3    Saumet, J.L.4    L'Huillier, J.P.5
  • 12
    • 0033104314 scopus 로고    scopus 로고
    • The association between laser Doppler reactive hyperaemia curves and the distribution of peripheral arterial disease
    • Ray S A, Buckenham T M, Belli A M, Taylor R S, Dormandy J A (1999) The association between laser Doppler reactive hyperaemia curves and the distribution of peripheral arterial disease. Eur. J. Vasc. Endovasc. Surg., 17:245-248
    • (1999) Eur. J. Vasc. Endovasc. Surg , vol.17 , pp. 245-248
    • Ray, S.A.1    Buckenham, T.M.2    Belli, A.M.3    Taylor, R.S.4    Dormandy, J.A.5
  • 13
    • 77950168720 scopus 로고    scopus 로고
    • Fagrell B (1990) Peripheral vascular diseases. Laser-Doppler Blood Flowmetry, A.P. Shepherd and P.Å. Öberg, pp. 201-213, Kluwer, Boston
    • Fagrell B (1990) Peripheral vascular diseases. Laser-Doppler Blood Flowmetry, A.P. Shepherd and P.Å. Öberg, pp. 201-213, Kluwer, Boston
  • 14
    • 0024246771 scopus 로고
    • The effects of topically applied hexil nicotinate lotion on the cutaneous blood flow in patients with Raynaud's phenomenon
    • Bunker C B, Lanigan S, Rustin M H, Dowd P M (1988) The effects of topically applied hexil nicotinate lotion on the cutaneous blood flow in patients with Raynaud's phenomenon. Br. J. Dermatol., 119:771-776
    • (1988) Br. J. Dermatol , vol.119 , pp. 771-776
    • Bunker, C.B.1    Lanigan, S.2    Rustin, M.H.3    Dowd, P.M.4
  • 16
    • 85047675880 scopus 로고
    • Laser Doppler velocimetry of fingertips during heat provocation in normals and in patients with Raynaud's phenomenon
    • Wollersheim H, Reyenga J, Thien T (1988) Laser Doppler velocimetry of fingertips during heat provocation in normals and in patients with Raynaud's phenomenon. Scand. J. Clin. Lab. Invest., 48:91-95
    • (1988) Scand. J. Clin. Lab. Invest , vol.48 , pp. 91-95
    • Wollersheim, H.1    Reyenga, J.2    Thien, T.3
  • 17
    • 0016630468 scopus 로고
    • In vivo evaluation of microcirculation by coherent light scattering
    • Stern M D (1975) In vivo evaluation of microcirculation by coherent light scattering. Nature, 254:56-58
    • (1975) Nature , vol.254 , pp. 56-58
    • Stern, M.D.1
  • 21
    • 0025435178 scopus 로고
    • In vivo comparison of a twin wavelength laser Doppler flowmeter using He-Ne and laser diode sources
    • Obeid A N, Dougherty G, Pettinger S (1990) In vivo comparison of a twin wavelength laser Doppler flowmeter using He-Ne and laser diode sources. J. Med. Eng. Tech., 14:102-110
    • (1990) J. Med. Eng. Tech , vol.14 , pp. 102-110
    • Obeid, A.N.1    Dougherty, G.2    Pettinger, S.3
  • 23
    • 3442897693 scopus 로고    scopus 로고
    • The influence of probe fiber distance on laser Doppler perfusion monitoring measurements
    • Morales F, Graaff R, Smit A J, Gush R, Rakhorst G (2003) The influence of probe fiber distance on laser Doppler perfusion monitoring measurements. Microcirculation, 10:433-441
    • (2003) Microcirculation , vol.10 , pp. 433-441
    • Morales, F.1    Graaff, R.2    Smit, A.J.3    Gush, R.4    Rakhorst, G.5
  • 24
    • 0036525877 scopus 로고    scopus 로고
    • Influence of optical properties and fiber separations on laser doppler flowmetry
    • Larsson M, Steenbergen W, Strömberg T (2002) Influence of optical properties and fiber separations on laser doppler flowmetry. J. Biomed. Opt., 7:236-243
    • (2002) J. Biomed. Opt , vol.7 , pp. 236-243
    • Larsson, M.1    Steenbergen, W.2    Strömberg, T.3
  • 25
    • 0028458916 scopus 로고
    • Laser-Doppler blood flowmetry using two wavelengths : Monte Carlo simulations and measurement
    • Koelink M H, de Mul F F M, Gerve J, Graaf R, Dassel A C M, Aarnoudse J G (1994) Laser-Doppler blood flowmetry using two wavelengths : Monte Carlo simulations and measurement, Appl. Opt., 33:3549-3558
    • (1994) Appl. Opt , vol.33 , pp. 3549-3558
    • Koelink, M.H.1    de Mul, F.F.M.2    Gerve, J.3    Graaf, R.4    Dassel, A.C.M.5    Aarnoudse, J.G.6
  • 26
    • 0026190715 scopus 로고
    • Discrimination of capillary and arteriovenular blood flow in skin by laser Doppler flowmetry
    • Gush R J, King T A (1991) Discrimination of capillary and arteriovenular blood flow in skin by laser Doppler flowmetry. Med. Biol. Eng. Comput., 29:387-392
    • (1991) Med. Biol. Eng. Comput , vol.29 , pp. 387-392
    • Gush, R.J.1    King, T.A.2
  • 27
    • 0026209407 scopus 로고
    • Influence of fibre diameter and probe geometry on the measuring depth of laser Doppler flowmetry in the gastrointestinal application
    • Johansson K, Jakobsson A, Lindahl K, Lindhagen J, Lundgren O, Nilsson G.E (1991) Influence of fibre diameter and probe geometry on the measuring depth of laser Doppler flowmetry in the gastrointestinal application, Int. J. Microcirc. Clin. Exp., 10:219-229
    • (1991) Int. J. Microcirc. Clin. Exp , vol.10 , pp. 219-229
    • Johansson, K.1    Jakobsson, A.2    Lindahl, K.3    Lindhagen, J.4    Lundgren, O.5    Nilsson, G.E.6
  • 28
  • 29
    • 0021712357 scopus 로고
    • Aspects of laser light scattering from skin tissue with application to laser Doppler blood flow measurement
    • Gush R J, King T A, and Jayson M I V (1984) Aspects of laser light scattering from skin tissue with application to laser Doppler blood flow measurement, Phys. Med. Biol., 29:1463-1476
    • (1984) Phys. Med. Biol , vol.29 , pp. 1463-1476
    • Gush, R.J.1    King, T.A.2    Jayson, M.I.V.3
  • 30
    • 31744446037 scopus 로고    scopus 로고
    • The influence of wavelength and probe configuration on findings of a skin vasoconstriction test when using laser Doppler perfusion devices
    • Freccero C, Wollmer P, Sundkvist G, Svensson H (2005) The influence of wavelength and probe configuration on findings of a skin vasoconstriction test when using laser Doppler perfusion devices. Microvascular Research, 71,:64-67
    • (2005) Microvascular Research , vol.71 , pp. 64-67
    • Freccero, C.1    Wollmer, P.2    Sundkvist, G.3    Svensson, H.4
  • 32
    • 14744291306 scopus 로고    scopus 로고
    • Evaluation of the parameters of total, nutritive, and shunt blood flows in the skin microvasculature using laser Doppler flowmetry
    • Krupatkin A I (2005) Evaluation of the parameters of total, nutritive, and shunt blood flows in the skin microvasculature using laser Doppler flowmetry. Human Physiol., 31: 98-102
    • (2005) Human Physiol , vol.31 , pp. 98-102
    • Krupatkin, A.I.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.