2
-
-
0026709009
-
The theoretical basis for the determination of optical pathlengths in tissue: Temporal and frequency analysis
-
ARRIDGR, S. R., COPE, M. and DELPY, D. T. (1992): 'The theoretical basis for the determination of optical pathlengths in tissue: temporal and frequency analysis', Phys. Med. Biol., 37, pp. 1531-1560
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 1531-1560
-
-
Arridgr, S.R.1
Cope, M.2
Delpy, D.T.3
-
4
-
-
0019583049
-
Model for laser Doppler measurements of blood flow in tissue
-
BONNER, R. and NOSSAL, R. (1981): 'Model for laser Doppler measurements of blood flow in tissue', Appl. Opt., 20, pp. 2097-2106
-
(1981)
Appl. Opt.
, vol.20
, pp. 2097-2106
-
-
Bonner, R.1
Nossal, R.2
-
5
-
-
0024119566
-
Biological zero in laser Doppler fluxmetry
-
CASPARY, L., CREUTZIG, A. and ALEXANDER, K. (1988): 'Biological zero in laser Doppler fluxmetry', Int. J. Microcirc., 7, pp. 367-371
-
(1988)
Int. J. Microcirc.
, vol.7
, pp. 367-371
-
-
Caspary, L.1
Creutzig, A.2
Alexander, K.3
-
6
-
-
0027673677
-
Biological zero of laser-Doppler fluxmetry: Microcirculatory correlates in the hamster cheek pouch during flow and no flow conditions
-
COLANTUONI, A., BERTUGLIA, S. and INTAGLIETTA, M. (1993): 'Biological zero of laser-Doppler fluxmetry: microcirculatory correlates in the hamster cheek pouch during flow and no flow conditions'. Int. J. Microcirc. Clin. Exp., 13, pp. 125-136
-
(1993)
Int. J. Microcirc. Clin. Exp.
, vol.13
, pp. 125-136
-
-
Colantuoni, A.1
Bertuglia, S.2
Intaglietta, M.3
-
7
-
-
0022971501
-
Evaluation of postischemic hyperemia on the skin using laser Doppler velocimetry: Study on patients with claudicatio intermittens
-
DELGUERCIO, R. M., LEONARDO, G. and ARPAIA, M. R. (1986): 'Evaluation of postischemic hyperemia on the skin using laser Doppler velocimetry: Study on patients with claudicatio intermittens', Microvisc. Res., 32, pp. 289-299
-
(1986)
Microvisc. Res.
, vol.32
, pp. 289-299
-
-
Delguercio, R.M.1
Leonardo, G.2
Arpaia, M.R.3
-
8
-
-
0024206831
-
Estimation of optical path length
-
DELPY, D., COPE, M., VAN DER ZEE, P., ARRIDGE, S., WRAY, S. and WYATT. J. (1988): 'Estimation of optical path length'. Phvs. Med. Biol., 33, pp. 1433-1442
-
(1988)
Phvs. Med. Biol.
, vol.33
, pp. 1433-1442
-
-
Delpy, D.1
Cope, M.2
Van Der Zee, P.3
Arridge, S.4
Wray, S.5
Wyatt, J.6
-
9
-
-
0022271568
-
A double wavelength laser Doppler system to investigate skin microcirculation
-
DUTEIL, L., BERNENGO, J. and SCHALLA, W. (1985): 'A double wavelength laser Doppler system to investigate skin microcirculation', IEEE Trans. Biomed. Eng., BME-32. pp. 439-447
-
(1985)
IEEE Trans. Biomed. Eng.
, vol.BME-32
, pp. 439-447
-
-
Duteil, L.1
Bernengo, J.2
Schalla, W.3
-
10
-
-
0000811587
-
Peripheral vascular disorders
-
SHEPHERD, A. P, and OBERG, P. A. (Eds), Kluwer
-
FAGRELL, B. (1990): 'Peripheral vascular disorders', in SHEPHERD, A. P, and OBERG, P. A. (Eds) 'Laser-Doppler blood flowmetry', (Kluwer), pp. 201-214
-
(1990)
Laser-Doppler Blood Flowmetry
, pp. 201-214
-
-
Fagrell, B.1
-
11
-
-
0001929364
-
Problems using laser Doppler on the skin in clinical practice
-
BELCARO, G., HUFFMAN, U., BOLLINGER, A. and NICOLAIDES, A. (Eds), MED-ORION, London
-
FAGRELL, B. (1994): 'Problems using laser Doppler on the skin in clinical practice', in BELCARO, G., HUFFMAN, U., BOLLINGER, A. and NICOLAIDES, A. (Eds), 'Laser-Doppler' (MED-ORION, London) pp. 49-54
-
(1994)
Laser-Doppler
, pp. 49-54
-
-
Fagrell, B.1
-
12
-
-
0342424995
-
-
FIBRE OPTICS CENTRE (1995): Technical data
-
(1995)
Technical Data
-
-
-
13
-
-
0021712357
-
Aspects of laser light scattering from skin tissue with application to laser Doppler blood flow measurement
-
GUSH, R. J., KING, T. A. and JAYSON, M. I. V. (1984): 'Aspects of laser light scattering from skin tissue with application to laser Doppler blood flow measurement', Phys. Med. Biol., 29, pp. 1463-1476
-
(1984)
Phys. Med. Biol.
, vol.29
, pp. 1463-1476
-
-
Gush, R.J.1
King, T.A.2
Jayson, M.I.V.3
-
14
-
-
0026190715
-
Discrimination of capillary and arterio-venular blood flow in skin by laser Doppler flowmetry
-
GUSH, R. and KING, T. (1991): 'Discrimination of capillary and arterio-venular blood flow in skin by laser Doppler flowmetry', Med. Biol. Eng. Comput., 29, pp. 387-392
-
(1991)
Med. Biol. Eng. Comput.
, vol.29
, pp. 387-392
-
-
Gush, R.1
King, T.2
-
15
-
-
0017851927
-
On the use of windows for harmonic analysis with the discrete Fourier transform
-
HARRIS, F. J. (1978): 'On the use of windows for harmonic analysis with the discrete Fourier transform', Proc. IEEE, 66. pp. 51-83
-
(1978)
Proc. IEEE
, vol.66
, pp. 51-83
-
-
Harris, F.J.1
-
16
-
-
0023897405
-
Partitional measurement of capillary and arteriovenous anastomotic blood flow in the human finger by laser-Doppler-flowmeter
-
HIRATA, K., NAGASAKA, T. and NODA, Y, (1988): 'Partitional measurement of capillary and arteriovenous anastomotic blood flow in the human finger by laser-Doppler-flowmeter', Eur. J. Appl. Physiol. 57, pp. 616-621
-
(1988)
Eur. J. Appl. Physiol.
, vol.57
, pp. 616-621
-
-
Hirata, K.1
Nagasaka, T.2
Noda, Y.3
-
17
-
-
0027591676
-
Prediction of sampling depth and photon pathlength in laser Doppler flowmetry
-
JAKOBSSON, A. and NILSSON, G. (1993): 'Prediction of sampling depth and photon pathlength in laser Doppler flowmetry', Med. Biol. Eng. Comput., 31, pp. 301-307
-
(1993)
Med. Biol. Eng. Comput.
, vol.31
, pp. 301-307
-
-
Jakobsson, A.1
Nilsson, G.2
-
18
-
-
84975655914
-
Monte Carlo simulations of laser Doppler blood flow measurements in tissue
-
JENTINK, H. W., DE MUL, F. F. M., HERMSEN, R. G. A. M., GRAAFF, R. and GREVE, J., (1990): 'Monte Carlo simulations of laser Doppler blood flow measurements in tissue', Appl. Opt., 29, pp. 2371-2381
-
(1990)
Appl. Opt.
, vol.29
, pp. 2371-2381
-
-
Jentink, H.W.1
De Mul, F.F.M.2
Hermsen, R.G.A.M.3
Graaff, R.4
Greve, J.5
-
19
-
-
84975598495
-
Laser Doppler flowmetry: Measurements in a layered perfusion model and Monte Carlo simulations of measurements
-
JENTINK, H, W., de MUL, F. F. M., GRAAFF, R., SUICHIES, H. E., AARNOUDSE, J. G. and GREVE, J. (1991): 'Laser Doppler flowmetry: measurements in a layered perfusion model and Monte Carlo simulations of measurements', Appl. Opt., 30, pp. 2592-2597
-
(1991)
Appl. Opt.
, vol.30
, pp. 2592-2597
-
-
Jentink, H.W.1
De Mul, F.F.M.2
Graaff, R.3
Suichies, H.E.4
Aarnoudse, J.G.5
Greve, J.6
-
20
-
-
0026209407
-
Influence of fiber diameter and probe geometry on the measuring depth of laser Doppler flowmetry in the gastrointestinal application
-
JOHANSSON, K., JAKOBSSON, A., LINDAHL, K., LINDHAGEN, J., LUNDGREN, O. and NILSSON, G. E. (1991): 'Influence of fiber diameter and probe geometry on the measuring depth of laser Doppler flowmetry in the gastrointestinal application'. Int. J. Microcirc. Clin. Exp., 10, pp. 219-229
-
(1991)
Int. J. Microcirc. Clin. Exp.
, vol.10
, pp. 219-229
-
-
Johansson, K.1
Jakobsson, A.2
Lindahl, K.3
Lindhagen, J.4
Lundgren, O.5
Nilsson, G.E.6
-
21
-
-
0024536250
-
Laser-Doppler flowmetry in evaluation of skin post-ischaemic reactive hyperaemia
-
KVERNEBO, K., SLASGSVOLD, C. and STRANDEN, M. (1989): 'Laser-Doppler flowmetry in evaluation of skin post-ischaemic reactive hyperaemia', J. Cardiovasc. Surg. 30, pp. 70-75
-
(1989)
J. Cardiovasc. Surg.
, vol.30
, pp. 70-75
-
-
Kvernebo, K.1
Slasgsvold, C.2
Stranden, M.3
-
22
-
-
0005397240
-
A calibration standard for laser-Doppler measurements
-
LIEBERT, A., LEAHY, M. and MANIEWSKI, R. (1995): 'A calibration standard for laser-Doppler measurements', Rev. Sci. Instr., 66, pp. 5169-5173
-
(1995)
Rev. Sci. Instr.
, vol.66
, pp. 5169-5173
-
-
Liebert, A.1
Leahy, M.2
Maniewski, R.3
-
23
-
-
0023628830
-
Contribution of arteriovenous anastomoses to vasoconstriction induced by local heating of the human finger
-
NAGASAKA, T., HIRATA, K. and NUNOMURA, T. (1987): 'Contribution of arteriovenous anastomoses to vasoconstriction induced by local heating of the human finger', Jpn. J. Physiol., 37, pp. 425-433
-
(1987)
Jpn. J. Physiol.
, vol.37
, pp. 425-433
-
-
Nagasaka, T.1
Hirata, K.2
Nunomura, T.3
-
24
-
-
0024043313
-
Depth discrimination in laser Doppler skin blood flow measurement using different lasers
-
OBEID, A., BOGGET, D., BARNETT, N., DOUGHERTY, G. and ROLFE, P. (1988): 'Depth discrimination in laser Doppler skin blood flow measurement using different lasers', Med. Biol. Eng. Comput., 26, pp. 415-419
-
(1988)
Med. Biol. Eng. Comput.
, vol.26
, pp. 415-419
-
-
Obeid, A.1
Bogget, D.2
Barnett, N.3
Dougherty, G.4
Rolfe, P.5
-
25
-
-
0025043445
-
Laser-Doppler flowmetry
-
ÖBERG, P.A. (1990): 'Laser-Doppler flowmetry', Crit. Rev. Biomed. Eng., 18, pp. 125-163
-
(1990)
Crit. Rev. Biomed. Eng.
, vol.18
, pp. 125-163
-
-
Öberg, P.A.1
-
26
-
-
7844230733
-
-
OXFORD OPTRONIX (1994): Technical data
-
(1994)
Technical Data
-
-
-
27
-
-
0026862264
-
Effects of local hyperemia and edema on the biological zero in laser doppler fluxmetry (LD)
-
WAHLBERG, E., OLOFSSON, P., SWEDENBORG, J. and FAGRELL, B. (1992): 'Effects of local hyperemia and edema on the biological zero in laser doppler fluxmetry (LD)', Int. J. Microcirc., 11, pp. 157-165
-
(1992)
Int. J. Microcirc.
, vol.11
, pp. 157-165
-
-
Wahlberg, E.1
Olofsson, P.2
Swedenborg, J.3
Fagrell, B.4
|