메뉴 건너뛰기




Volumn 28, Issue 4, 2010, Pages 462-467

Effect of fracture gap on stability of compression plate fixation: A finite element study

Author keywords

Compression plating; Finite element analysis; Fracture gap; Stability; Stiffness

Indexed keywords

ARTICLE; BIOMECHANICS; BONE DEFECT; BONE PLATE; COMPRESSION; CONTROLLED STUDY; FINITE ELEMENT ANALYSIS; FRACTURE; FRACTURE GAP; MECHANICAL STRESS; PLATE FIXATION; PRIORITY JOURNAL; RIGIDITY; VALIDITY; ELASTICITY; EQUIPMENT; FRACTURE HEALING; INSTRUMENTATION; INTERNAL FIXATOR; METHODOLOGY; OSTEOSYNTHESIS; PHYSIOLOGY;

EID: 77949516213     PISSN: 07360266     EISSN: 1554527X     Source Type: Journal    
DOI: 10.1002/jor.20990     Document Type: Article
Times cited : (40)

References (22)
  • 1
    • 0036854433 scopus 로고    scopus 로고
    • Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: Choosing a new balance between stability and biology
    • Br
    • Perren SM. 2002. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg [Br] 84:1093-1110.
    • (2002) J Bone Joint Surg , vol.84 , pp. 1093-1110
    • Perren, S.M.1
  • 2
    • 0029692879 scopus 로고    scopus 로고
    • The strength of plate fixation in relation to the number and spacing of bone screws
    • Tornkvist H, Hearn TC, Schatzker J. 1996. The strength of plate fixation in relation to the number and spacing of bone screws. J Orthop Trauma 10:204-208.
    • (1996) J Orthop Trauma , vol.10 , pp. 204-208
    • Tornkvist, H.1    Hearn, T.C.2    Schatzker, J.3
  • 3
    • 33646477698 scopus 로고    scopus 로고
    • Fixation of diaphyseal fractures with a segmental defect: A biomechanical comparison of locked and conventional plating techniques
    • Fulkerson E, Egol KA, Kubiak EN, et al. 2006. Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. J Trauma 60:830-835.
    • (2006) J Trauma , vol.60 , pp. 830-835
    • Fulkerson, E.1    Egol, K.A.2    Kubiak, E.N.3
  • 4
    • 0030050456 scopus 로고    scopus 로고
    • A comparative biomechanical evaluation of a noncontacting plate and currently used devices for tibial fixation
    • Kowalski MJ, Schemitsch EH, Harrington RM, et al. 1996. A comparative biomechanical evaluation of a noncontacting plate and currently used devices for tibial fixation. J Trauma 40:5-9.
    • (1996) J Trauma , vol.40 , pp. 5-9
    • Kowalski, M.J.1    Schemitsch, E.H.2    Harrington, R.M.3
  • 5
    • 2642514242 scopus 로고    scopus 로고
    • A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates
    • Korner J, Diederichs G, Arzdorf M, et al. 2004. A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates. J Orthop Trauma 18:286-293.
    • (2004) J Orthop Trauma , vol.18 , pp. 286-293
    • Korner, J.1    Diederichs, G.2    Arzdorf, M.3
  • 6
    • 0036198119 scopus 로고    scopus 로고
    • Minimal versus maximal plate fixation techniques of the ulna: The biomechanical effect of number of screws and plate length
    • Sanders R, Haidukewych GJ, Milne T, et al. 2002. Minimal versus maximal plate fixation techniques of the ulna: the biomechanical effect of number of screws and plate length. J Orthop Trauma 16:166-171.
    • (2002) J Orthop Trauma , vol.16 , pp. 166-171
    • Sanders, R.1    Haidukewych, G.J.2    Milne, T.3
  • 7
    • 16644362839 scopus 로고    scopus 로고
    • Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium
    • Stoffel K, Stachowiak G, Forster T, et al. 2004. Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium. J Orthop Trauma 18:611-616.
    • (2004) J Orthop Trauma , vol.18 , pp. 611-616
    • Stoffel, K.1    Stachowiak, G.2    Forster, T.3
  • 8
    • 0030131057 scopus 로고
    • Finite element stress analysis of a hybrid fracture fixation plate
    • Ferguson SJWU, Pichora DR. 1995. Finite element stress analysis of a hybrid fracture fixation plate. Med Eng Phys 18:241-250.
    • (1995) Med Eng Phys , vol.18 , pp. 241-250
    • Ferguson, S.J.W.U.1    Pichora, D.R.2
  • 10
    • 17344392681 scopus 로고    scopus 로고
    • Loading model for the human femur taking the tension band effect of the ilio-tibial tract into account
    • Cordey J, Borgeaud M, Frankle M, et al. 1999. Loading model for the human femur taking the tension band effect of the ilio-tibial tract into account. Injury 30 (Suppl 1):A26-A30.
    • (1999) Injury , vol.30 , Issue.SUPPL. 1
    • Cordey, J.1    Borgeaud, M.2    Frankle, M.3
  • 11
    • 14844325693 scopus 로고    scopus 로고
    • Design of fracture fixation plate for necessary and sufficient bone stress shielding
    • Ramakrishna KSI, Sivashanker I, Khong KS. et al. 2004. Design of fracture fixation plate for necessary and sufficient bone stress shielding. JSME Int J Ser C:1086-1094.
    • (2004) JSME Int J Ser C , pp. 1086-1094
    • Ramakrishna, K.S.I.1    Sivashanker, I.2    Khong, K.S.3
  • 12
    • 0142168925 scopus 로고    scopus 로고
    • Biomechanical testing of the LCP - how can stability in locked internal fixators be controlled?
    • Stoffel K, Dieter U, Stachowiak G, et al. 2003. Biomechanical testing of the LCP - how can stability in locked internal fixators be controlled? Injury 34 (Suppl 2):B11-B19.
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Stoffel, K.1    Dieter, U.2    Stachowiak, G.3
  • 13
    • 0035704172 scopus 로고    scopus 로고
    • Force transfer between the plate and the bone: Relative importance of the bending stiffness of the screws friction between plate and bone
    • Cordey J, Borgeaud M, Perren SM. 2000. Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between plate and bone. Injury 31 (Suppl 3):C21-C28.
    • (2000) Injury , vol.31 , Issue.SUPPL. 3
    • Cordey, J.1    Borgeaud, M.2    Perren, S.M.3
  • 14
    • 0034267111 scopus 로고    scopus 로고
    • Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis
    • Gautier E, Perren SM, Cordey J. 2000. Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis. Injury 31 (Suppl 3):C14-C20.
    • (2000) Injury , vol.31 , Issue.SUPPL. 3
    • Gautier, E.1    Perren, S.M.2    Cordey, J.3
  • 15
    • 0015456011 scopus 로고
    • Plate-bone friction in the compression fixation of fractures
    • Hayes WC, Perren SM. 1972. Plate-bone friction in the compression fixation of fractures. Clin Orthop Relat Res 89:236-240.
    • (1972) Clin Orthop Relat Res , vol.89 , pp. 236-240
    • Hayes, W.C.1    Perren, S.M.2
  • 16
    • 0018762030 scopus 로고
    • Physical and biological aspects of fracture healing with special reference to internal fixation
    • Perren SM. 1979. Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop Relat Res 175-196.
    • (1979) Clin Orthop Relat Res , pp. 175-196
    • Perren, S.M.1
  • 17
    • 0142230911 scopus 로고    scopus 로고
    • First clinical results of the locking compression plate (LCP)
    • Sommer C, Gautier E, Muller M, et al. 2003. First clinical results of the locking compression plate (LCP). Injury 34 (Suppl 2):B43-B54.
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Sommer, C.1    Gautier, E.2    Muller, M.3
  • 18
    • 0036799950 scopus 로고    scopus 로고
    • Fixation stability of comminuted humeral shaft fractures: Locked intramedullary nailing versus plate fixation
    • Chen AL, Joseph TN, Wolinksy PR, et al. 2002. Fixation stability of comminuted humeral shaft fractures: locked intramedullary nailing versus plate fixation. J Trauma 53:733-737.
    • (2002) J Trauma , vol.53 , pp. 733-737
    • Chen, A.L.1    Joseph, T.N.2    Wolinksy, P.R.3
  • 19
    • 58649101626 scopus 로고    scopus 로고
    • Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis
    • Fitzpatrick DC, Doornink J, Madey SM, et al. 2009. Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis. Clin Biomech (Bristol, Avon) 24:203-209.
    • (2009) Clin Biomech (Bristol, Avon) , vol.24 , pp. 203-209
    • Fitzpatrick, D.C.1    Doornink, J.2    Madey, S.M.3
  • 20
    • 0034263187 scopus 로고    scopus 로고
    • Stress protection due to plates: Myth or reality? A parametric analysis made using the composite beam theory
    • Cordey J, Perren SM, Steinemann SG. 2000. Stress protection due to plates: myth or reality? A parametric analysis made using the composite beam theory. Injury 31 (Suppl 3):C1-C13.
    • (2000) Injury , vol.31 , Issue.SUPPL. 3
    • Cordey, J.1    Perren, S.M.2    Steinemann, S.G.3
  • 21
    • 0035292772 scopus 로고    scopus 로고
    • Influence of the number of cortices on the stiffness of plate fixation of diaphyseal fractures
    • El Maraghy AW, El Maraghy MW, Nousiainen M. et al. 2001. Influence of the number of cortices on the stiffness of plate fixation of diaphyseal fractures. J Orthop Trauma 15:186-191.
    • (2001) J Orthop Trauma , vol.15 , pp. 186-191
    • El Maraghy, A.W.1    El Maraghy, M.W.2    Nousiainen, M.3
  • 22
    • 0023984796 scopus 로고
    • The influence of different degrees of stiffness of fixation plates on experimental bone healing
    • Terjesen T, Apalset K. 1988. The influence of different degrees of stiffness of fixation plates on experimental bone healing. J Orthop Res 6:293-299.
    • (1988) J Orthop Res , vol.6 , pp. 293-299
    • Terjesen, T.1    Apalset, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.