-
1
-
-
0036854433
-
Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: Choosing a new balance between stability and biology
-
Br
-
Perren SM. 2002. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg [Br] 84:1093-1110.
-
(2002)
J Bone Joint Surg
, vol.84
, pp. 1093-1110
-
-
Perren, S.M.1
-
2
-
-
0029692879
-
The strength of plate fixation in relation to the number and spacing of bone screws
-
Tornkvist H, Hearn TC, Schatzker J. 1996. The strength of plate fixation in relation to the number and spacing of bone screws. J Orthop Trauma 10:204-208.
-
(1996)
J Orthop Trauma
, vol.10
, pp. 204-208
-
-
Tornkvist, H.1
Hearn, T.C.2
Schatzker, J.3
-
3
-
-
33646477698
-
Fixation of diaphyseal fractures with a segmental defect: A biomechanical comparison of locked and conventional plating techniques
-
Fulkerson E, Egol KA, Kubiak EN, et al. 2006. Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. J Trauma 60:830-835.
-
(2006)
J Trauma
, vol.60
, pp. 830-835
-
-
Fulkerson, E.1
Egol, K.A.2
Kubiak, E.N.3
-
4
-
-
0030050456
-
A comparative biomechanical evaluation of a noncontacting plate and currently used devices for tibial fixation
-
Kowalski MJ, Schemitsch EH, Harrington RM, et al. 1996. A comparative biomechanical evaluation of a noncontacting plate and currently used devices for tibial fixation. J Trauma 40:5-9.
-
(1996)
J Trauma
, vol.40
, pp. 5-9
-
-
Kowalski, M.J.1
Schemitsch, E.H.2
Harrington, R.M.3
-
5
-
-
2642514242
-
A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates
-
Korner J, Diederichs G, Arzdorf M, et al. 2004. A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates. J Orthop Trauma 18:286-293.
-
(2004)
J Orthop Trauma
, vol.18
, pp. 286-293
-
-
Korner, J.1
Diederichs, G.2
Arzdorf, M.3
-
6
-
-
0036198119
-
Minimal versus maximal plate fixation techniques of the ulna: The biomechanical effect of number of screws and plate length
-
Sanders R, Haidukewych GJ, Milne T, et al. 2002. Minimal versus maximal plate fixation techniques of the ulna: the biomechanical effect of number of screws and plate length. J Orthop Trauma 16:166-171.
-
(2002)
J Orthop Trauma
, vol.16
, pp. 166-171
-
-
Sanders, R.1
Haidukewych, G.J.2
Milne, T.3
-
7
-
-
16644362839
-
Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium
-
Stoffel K, Stachowiak G, Forster T, et al. 2004. Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium. J Orthop Trauma 18:611-616.
-
(2004)
J Orthop Trauma
, vol.18
, pp. 611-616
-
-
Stoffel, K.1
Stachowiak, G.2
Forster, T.3
-
8
-
-
0030131057
-
Finite element stress analysis of a hybrid fracture fixation plate
-
Ferguson SJWU, Pichora DR. 1995. Finite element stress analysis of a hybrid fracture fixation plate. Med Eng Phys 18:241-250.
-
(1995)
Med Eng Phys
, vol.18
, pp. 241-250
-
-
Ferguson, S.J.W.U.1
Pichora, D.R.2
-
10
-
-
17344392681
-
Loading model for the human femur taking the tension band effect of the ilio-tibial tract into account
-
Cordey J, Borgeaud M, Frankle M, et al. 1999. Loading model for the human femur taking the tension band effect of the ilio-tibial tract into account. Injury 30 (Suppl 1):A26-A30.
-
(1999)
Injury
, vol.30
, Issue.SUPPL. 1
-
-
Cordey, J.1
Borgeaud, M.2
Frankle, M.3
-
11
-
-
14844325693
-
Design of fracture fixation plate for necessary and sufficient bone stress shielding
-
Ramakrishna KSI, Sivashanker I, Khong KS. et al. 2004. Design of fracture fixation plate for necessary and sufficient bone stress shielding. JSME Int J Ser C:1086-1094.
-
(2004)
JSME Int J Ser C
, pp. 1086-1094
-
-
Ramakrishna, K.S.I.1
Sivashanker, I.2
Khong, K.S.3
-
12
-
-
0142168925
-
Biomechanical testing of the LCP - how can stability in locked internal fixators be controlled?
-
Stoffel K, Dieter U, Stachowiak G, et al. 2003. Biomechanical testing of the LCP - how can stability in locked internal fixators be controlled? Injury 34 (Suppl 2):B11-B19.
-
(2003)
Injury
, vol.34
, Issue.SUPPL. 2
-
-
Stoffel, K.1
Dieter, U.2
Stachowiak, G.3
-
13
-
-
0035704172
-
Force transfer between the plate and the bone: Relative importance of the bending stiffness of the screws friction between plate and bone
-
Cordey J, Borgeaud M, Perren SM. 2000. Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between plate and bone. Injury 31 (Suppl 3):C21-C28.
-
(2000)
Injury
, vol.31
, Issue.SUPPL. 3
-
-
Cordey, J.1
Borgeaud, M.2
Perren, S.M.3
-
14
-
-
0034267111
-
Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis
-
Gautier E, Perren SM, Cordey J. 2000. Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis. Injury 31 (Suppl 3):C14-C20.
-
(2000)
Injury
, vol.31
, Issue.SUPPL. 3
-
-
Gautier, E.1
Perren, S.M.2
Cordey, J.3
-
15
-
-
0015456011
-
Plate-bone friction in the compression fixation of fractures
-
Hayes WC, Perren SM. 1972. Plate-bone friction in the compression fixation of fractures. Clin Orthop Relat Res 89:236-240.
-
(1972)
Clin Orthop Relat Res
, vol.89
, pp. 236-240
-
-
Hayes, W.C.1
Perren, S.M.2
-
16
-
-
0018762030
-
Physical and biological aspects of fracture healing with special reference to internal fixation
-
Perren SM. 1979. Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop Relat Res 175-196.
-
(1979)
Clin Orthop Relat Res
, pp. 175-196
-
-
Perren, S.M.1
-
17
-
-
0142230911
-
First clinical results of the locking compression plate (LCP)
-
Sommer C, Gautier E, Muller M, et al. 2003. First clinical results of the locking compression plate (LCP). Injury 34 (Suppl 2):B43-B54.
-
(2003)
Injury
, vol.34
, Issue.SUPPL. 2
-
-
Sommer, C.1
Gautier, E.2
Muller, M.3
-
18
-
-
0036799950
-
Fixation stability of comminuted humeral shaft fractures: Locked intramedullary nailing versus plate fixation
-
Chen AL, Joseph TN, Wolinksy PR, et al. 2002. Fixation stability of comminuted humeral shaft fractures: locked intramedullary nailing versus plate fixation. J Trauma 53:733-737.
-
(2002)
J Trauma
, vol.53
, pp. 733-737
-
-
Chen, A.L.1
Joseph, T.N.2
Wolinksy, P.R.3
-
19
-
-
58649101626
-
Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis
-
Fitzpatrick DC, Doornink J, Madey SM, et al. 2009. Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis. Clin Biomech (Bristol, Avon) 24:203-209.
-
(2009)
Clin Biomech (Bristol, Avon)
, vol.24
, pp. 203-209
-
-
Fitzpatrick, D.C.1
Doornink, J.2
Madey, S.M.3
-
20
-
-
0034263187
-
Stress protection due to plates: Myth or reality? A parametric analysis made using the composite beam theory
-
Cordey J, Perren SM, Steinemann SG. 2000. Stress protection due to plates: myth or reality? A parametric analysis made using the composite beam theory. Injury 31 (Suppl 3):C1-C13.
-
(2000)
Injury
, vol.31
, Issue.SUPPL. 3
-
-
Cordey, J.1
Perren, S.M.2
Steinemann, S.G.3
-
21
-
-
0035292772
-
Influence of the number of cortices on the stiffness of plate fixation of diaphyseal fractures
-
El Maraghy AW, El Maraghy MW, Nousiainen M. et al. 2001. Influence of the number of cortices on the stiffness of plate fixation of diaphyseal fractures. J Orthop Trauma 15:186-191.
-
(2001)
J Orthop Trauma
, vol.15
, pp. 186-191
-
-
El Maraghy, A.W.1
El Maraghy, M.W.2
Nousiainen, M.3
-
22
-
-
0023984796
-
The influence of different degrees of stiffness of fixation plates on experimental bone healing
-
Terjesen T, Apalset K. 1988. The influence of different degrees of stiffness of fixation plates on experimental bone healing. J Orthop Res 6:293-299.
-
(1988)
J Orthop Res
, vol.6
, pp. 293-299
-
-
Terjesen, T.1
Apalset, K.2
|