메뉴 건너뛰기




Volumn 93, Issue 1, 2010, Pages 258-265

Effect of stem preheating and precooling on residual stress formation at stem/cement interface for cemented hip implants

Author keywords

Bone cement (PMMA); Hip prosthesis; Polymerization; Residual stresses; Setting time; Stem preheating; Temperature

Indexed keywords

BONE; CURING; HIP PROSTHESES; MIXING; POLYMERIC IMPLANTS; POLYMERIZATION; PREHEATING; RESIDUAL STRESSES; SETTING; TEMPERATURE;

EID: 77949515971     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31583     Document Type: Article
Times cited : (8)

References (35)
  • 1
    • 0015445231 scopus 로고
    • Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury
    • Lundskog J. Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury. Scand J Plast Reconstr Surg 1972;9:1-80.
    • (1972) Scand J Plast Reconstr Surg , vol.9 , pp. 1-80
    • Lundskog, J.1
  • 2
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury: A vital microscopic study in the rabbit
    • Eriksson RA, Alberektsson T. Temperature threshold levels for heat-induced bone tissue injury: A vital microscopic study in the rabbit. J Prosthet Dent 1983;50:101-106.
    • (1983) J Prosthet Dent , vol.50 , pp. 101-106
    • Eriksson, R.A.1    Alberektsson, T.2
  • 3
    • 0020097103 scopus 로고
    • Transient and residual stresses and displacements in self-curing bone cement, Part 1: Characterization of relevant volumetric behavior of bone cement
    • Ahmed AM, Burke DL, Miller J, Nair R. Transient and residual stresses and displacements in self-curing bone cement, Part 1: Characterization of relevant volumetric behavior of bone cement. J Biomech Eng 1982;104:21-27.
    • (1982) J Biomech Eng , vol.104 , pp. 21-27
    • Ahmed, A.M.1    Burke, D.L.2    Miller, J.3    Nair, R.4
  • 4
    • 25844516621 scopus 로고    scopus 로고
    • The effects of fluid penetration and interfacial porosity on the fixation of cemented femoral components
    • Iesaka K, Jaffe WL, Jones CM, Kummer FJ. The effects of fluid penetration and interfacial porosity on the fixation of cemented femoral components. J Bone Joint Surg Br 2005;87-B:1298-1302.
    • (2005) J Bone Joint Surg Br , vol.87-B , pp. 1298-1302
    • Iesaka, K.1    Jaffe, W.L.2    Jones, C.M.3    Kummer, F.J.4
  • 5
    • 7444224842 scopus 로고    scopus 로고
    • Thermal analysis of bone cement polymerisation at the cement-bone interface
    • Stanczyk M, van Rietbergen B. Thermal analysis of bone cement polymerisation at the cement-bone interface. J Biomech 2004;37: 1803-1810.
    • (2004) J Biomech , vol.37 , pp. 1803-1810
    • Stanczyk, M.1    van Rietbergen, B.2
  • 6
    • 0037756784 scopus 로고    scopus 로고
    • Effects of pre-cooling and pre-heating procedures on cement polymerization and thermal osteonecrosis in cemented hip replacements
    • Li C, Schmid S, Mason J. Effects of pre-cooling and pre-heating procedures on cement polymerization and thermal osteonecrosis in cemented hip replacements. Med Eng Phys 2003;25:559-564.
    • (2003) Med Eng Phys , vol.25 , pp. 559-564
    • Li, C.1    Schmid, S.2    Mason, J.3
  • 7
    • 49449087066 scopus 로고    scopus 로고
    • Measurement of transient and residual stresses during polymerization of bone cement for cemented hip implants
    • Nuño N, Madrala A, Plamondon D. Measurement of transient and residual stresses during polymerization of bone cement for cemented hip implants. J Biomech 2008;41:2605-2611.
    • (2008) J Biomech , vol.41 , pp. 2605-2611
    • Nuño, N.1    Madrala, A.2    Plamondon, D.3
  • 8
    • 1642402000 scopus 로고    scopus 로고
    • Quantitative measurement of the stresses induced during polymerisation of bone cement
    • Roques A, Brown M, Taylor A, New A, Baker D. Quantitative measurement of the stresses induced during polymerisation of bone cement. Biomaterials 2004;25:4415-4424.
    • (2004) Biomaterials , vol.25 , pp. 4415-4424
    • Roques, A.1    Brown, M.2    Taylor, A.3    New, A.4    Baker, D.5
  • 9
    • 0036909341 scopus 로고    scopus 로고
    • The dynamic volume changes of polymerising polymethyl methacrylate bone cement
    • Muller SD, Green SM, McCaskie AW. The dynamic volume changes of polymerising polymethyl methacrylate bone cement. Acta Orthop Scand 2002;73:684-687.
    • (2002) Acta Orthop Scand , vol.73 , pp. 684-687
    • Muller, S.D.1    Green, S.M.2    McCaskie, A.W.3
  • 10
    • 0029941585 scopus 로고    scopus 로고
    • Porosity reduction in bone cement at the cement-stem interface
    • Bishop NE, Ferguson S, Tepic S. Porosity reduction in bone cement at the cement-stem interface. J Bone Joint Surg Br 1996; 78B:349-356.
    • (1996) J Bone Joint Surg Br , vol.78 B , pp. 349-356
    • Bishop, N.E.1    Ferguson, S.2    Tepic, S.3
  • 11
    • 0036171714 scopus 로고    scopus 로고
    • Residual stress due to curing can initiate damage in porous bone cement: Experimental and theoretical evidence
    • Lennon AB, Prendergast PJ. Residual stress due to curing can initiate damage in porous bone cement: Experimental and theoretical evidence. J Biomech 2002;35:311-321.
    • (2002) J Biomech , vol.35 , pp. 311-321
    • Lennon, A.B.1    Prendergast, P.J.2
  • 12
    • 0036157044 scopus 로고    scopus 로고
    • Modelling debonded stem-cement interface for hip implants: Effect of residual stresses
    • Nuño N, Amabili M. Modelling debonded stem-cement interface for hip implants: Effect of residual stresses. Clin Biomech 2002;17: 41-48.
    • (2002) Clin Biomech , vol.17 , pp. 41-48
    • Nuño, N.1    Amabili, M.2
  • 14
    • 0020093517 scopus 로고
    • Transient and residual stresses and displacements in self-curing bone cement, Part 2: Thermoelastic analysis of the stem fixation system
    • Ahmed AM, Pak W, Burke DL, Miller J. Transient and residual stresses and displacements in self-curing bone cement, Part 2: Thermoelastic analysis of the stem fixation system. J Biomech Eng 1982;104:28-37.
    • (1982) J Biomech Eng , vol.104 , pp. 28-37
    • Ahmed, A.M.1    Pak, W.2    Burke, D.L.3    Miller, J.4
  • 15
  • 16
    • 3042803662 scopus 로고    scopus 로고
    • The effects of curing history on residual stresses in bone cement during hip arthroplasty
    • Li C, Wang Y, Mason J. The effects of curing history on residual stresses in bone cement during hip arthroplasty. J Biomed Mater Res B Appl Biomater 2004;70B:30-36.
    • (2004) J Biomed Mater Res B Appl Biomater , vol.70 B , pp. 30-36
    • Li, C.1    Wang, Y.2    Mason, J.3
  • 17
    • 68049092918 scopus 로고    scopus 로고
    • Computational modelling of bone cement polymerization: Temperature and residual stresses
    • Pérez MA, Nuño N, Madrala A, García-Aznar JM, DoblaréM. Computational modelling of bone cement polymerization: Temperature and residual stresses. Comput Biol Med 2009;39: 751-759.
    • (2009) Comput Biol Med , vol.39 , pp. 751-759
    • Pérez, M.A.1    Nuño, N.2    Madrala, A.3    García-Aznar, J.M.4    DoblaréM5
  • 18
    • 0036380713 scopus 로고    scopus 로고
    • Theoretical prediction and experimental determination of the effect of mold characteristics on temperature and monomer conversion fraction profiles during polymerization of a PMMA-based bone cement
    • Vallo CI. Theoretical prediction and experimental determination of the effect of mold characteristics on temperature and monomer conversion fraction profiles during polymerization of a PMMA-based bone cement. J Biomed Mater Res 2002;63:627-642.
    • (2002) J Biomed Mater Res , vol.63 , pp. 627-642
    • Vallo, C.I.1
  • 19
    • 1342282933 scopus 로고    scopus 로고
    • The chemistry of acrylic bone cements and implications for clinical use in image-guided therapy
    • Nussbaum DA, Gailloud P, Murphy K. The chemistry of acrylic bone cements and implications for clinical use in image-guided therapy. J Vasc Interv Radiol 2004;15:121-126.
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 121-126
    • Nussbaum, D.A.1    Gailloud, P.2    Murphy, K.3
  • 20
    • 0022971948 scopus 로고
    • Accelerated polymerization of acrylic bone cement using preheated implants
    • Dall DM, Miles AW, Juby G. Accelerated polymerization of acrylic bone cement using preheated implants. Clin Orthop Relat Res 1986;211:148-150.
    • (1986) Clin Orthop Relat Res , vol.211 , pp. 148-150
    • Dall, D.M.1    Miles, A.W.2    Juby, G.3
  • 21
    • 77949537082 scopus 로고    scopus 로고
    • Swedish Hip Arthroplasty Register-Annual Report 2007. Department of Orthopaedics, Sahlgrenska University Hospital, Göteborg, Sweden.
    • Swedish Hip Arthroplasty Register-Annual Report 2007. Department of Orthopaedics, Sahlgrenska University Hospital, Göteborg, Sweden.
  • 23
    • 0037283078 scopus 로고    scopus 로고
    • Factors affecting the static shear strength of the prosthetic stem-bone cement interface
    • Wang JS, Taylor M, Flivik G, Lidgren L. Factors affecting the static shear strength of the prosthetic stem-bone cement interface. J Mater Sci Mater Med 2003;14:55-61.
    • (2003) J Mater Sci Mater Med , vol.14 , pp. 55-61
    • Wang, J.S.1    Taylor, M.2    Flivik, G.3    Lidgren, L.4
  • 24
    • 33745713061 scopus 로고    scopus 로고
    • Fatigue debonding of the roughened stem-cement interface: Effects of surface roughness and stem heating conditions
    • Damron LA, Kim D-G, Mann KA. Fatigue debonding of the roughened stem-cement interface: Effects of surface roughness and stem heating conditions. J Biomed Mater Res B Appl Biomater 2006;78B:181-188.
    • (2006) J Biomed Mater Res B Appl Biomater , vol.78 B , pp. 181-188
    • Damron, L.A.1    Kim, D.-G.2    Mann, K.A.3
  • 25
    • 0037362675 scopus 로고    scopus 로고
    • Effects of preheating of hip prostheses on the stem-cement interface
    • Iesaka K, Jaffe WL, Kummer FJ. Effects of preheating of hip prostheses on the stem-cement interface. J Bone Joint Surg Am 2003; 85:421-427.
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 421-427
    • Iesaka, K.1    Jaffe, W.L.2    Kummer, F.J.3
  • 26
    • 0025614369 scopus 로고
    • Prechilling and vacuum mixing not suitable for all bone cements. Handling characteristics and exotherms of bone cements
    • Hansen D, Jensen JS. Prechilling and vacuum mixing not suitable for all bone cements. Handling characteristics and exotherms of bone cements. J Arthroplasty 1990;5:287-290.
    • (1990) J Arthroplasty , vol.5 , pp. 287-290
    • Hansen, D.1    Jensen, J.S.2
  • 27
    • 18044369252 scopus 로고    scopus 로고
    • Effects of pre-cooling and pre-heating procedures on cement polymerisation and thermal osteonecrosis in cemented hip replacements
    • Talbot JC, Shaw DL. Effects of pre-cooling and pre-heating procedures on cement polymerisation and thermal osteonecrosis in cemented hip replacements. Med Eng Phys 2005;27:439.
    • (2005) Med Eng Phys , vol.27 , pp. 439
    • Talbot, J.C.1    Shaw, D.L.2
  • 28
    • 23844462551 scopus 로고    scopus 로고
    • Thermal manipulation of bone cement
    • Jiranek W. Thermal manipulation of bone cement. Orthopedics 2005;28:S863-S866.
    • (2005) Orthopedics , vol.28
    • Jiranek, W.1
  • 29
    • 77949499476 scopus 로고    scopus 로고
    • Salvati EA, Wright TM. Commentary & Perspective on Effects of preheating of hip prostheses on the stem-cement interface by Kazuho Iesaka, MD, et al. J Bone Joint Surg 2003.
    • Salvati EA, Wright TM. Commentary & Perspective on "Effects of preheating of hip prostheses on the stem-cement interface" by Kazuho Iesaka, MD, et al. J Bone Joint Surg 2003.
  • 30
  • 31
    • 0141961725 scopus 로고    scopus 로고
    • Mixing of acrylic bone cement: Effect of oxygen on setting properties
    • He SL, Scott C, Higham P. Mixing of acrylic bone cement: Effect of oxygen on setting properties. Biomaterials 2003;24:5045-5048.
    • (2003) Biomaterials , vol.24 , pp. 5045-5048
    • He, S.L.1    Scott, C.2    Higham, P.3
  • 32
    • 33947364877 scopus 로고    scopus 로고
    • Stem-cement porosity may explain early loosening of cemented femoral hip components: Experimental-computational in vitro study
    • Mann KA, Damron LA, Miller MA, Race A, Clarke MT, Cleary RJ. Stem-cement porosity may explain early loosening of cemented femoral hip components: Experimental-computational in vitro study. J Orthop Res 2007;25:340-350.
    • (2007) J Orthop Res , vol.25 , pp. 340-350
    • Mann, K.A.1    Damron, L.A.2    Miller, M.A.3    Race, A.4    Clarke, M.T.5    Cleary, R.J.6
  • 33
    • 0021747492 scopus 로고
    • Strength of polymethylmethacrylate increased by vacuum mixing
    • Lidgren L, Drar H, Möller J. Strength of polymethylmethacrylate increased by vacuum mixing. Acta Orthop Scand 1984;55:536-541.
    • (1984) Acta Orthop Scand , vol.55 , pp. 536-541
    • Lidgren, L.1    Drar, H.2    Möller, J.3
  • 35
    • 0031013653 scopus 로고    scopus 로고
    • Influence of temperature and vacuum mixing on bone cement properties
    • Smeds S, Goertzen D, Ivarsson I. Influence of temperature and vacuum mixing on bone cement properties. Clin Orthop Relat Res 1997:326-334.
    • (1997) Clin Orthop Relat Res , pp. 326-334
    • Smeds, S.1    Goertzen, D.2    Ivarsson, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.