1
-
-
0028282143
-
Early migration and late aseptic failiure of proximal femoral prostheses
-
Freeman MA, Plante-Bordeneuve P. 1994. Early migration and late aseptic failiure of proximal femoral prostheses. J Bone Joint Surg Br 76:432-438.
-
(1994)
J Bone Joint Surg Br
, vol.76
, pp. 432-438
-
-
Freeman, M.A.1
Plante-Bordeneuve, P.2
-
2
-
-
0028034860
-
Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses
-
Karrholm J, Borssen B, Lowenhielm G, et al. 1994. Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg Br 76:912-917.
-
(1994)
J Bone Joint Surg Br
, vol.76
, pp. 912-917
-
-
Karrholm, J.1
Borssen, B.2
Lowenhielm, G.3
-
3
-
-
0029135432
-
Prediction of clinical outcome of THR from migration measurements on standard radiographs. A study of cemented Charnley and Stanmore femoral stems
-
Walker PS, Mai SF, Cobb AG, et al. 1995. Prediction of clinical outcome of THR from migration measurements on standard radiographs. A study of cemented Charnley and Stanmore femoral stems. J Bone Joint Surg Br 77:705-714.
-
(1995)
J Bone Joint Surg Br
, vol.77
, pp. 705-714
-
-
Walker, P.S.1
Mai, S.F.2
Cobb, A.G.3
-
4
-
-
0031792614
-
Importance of a thin cement mantle: Autopsy studies of eight hips
-
Kawate K, Maloney WJ, Bragdon CR, et al. 1998. Importance of a thin cement mantle: autopsy studies of eight hips. Clin Orthop 355:70-76.
-
(1998)
Clin Orthop
, vol.355
, pp. 70-76
-
-
Kawate, K.1
Maloney, W.J.2
Bragdon, C.R.3
-
5
-
-
0033861254
-
Long-term registration has improved the quality of hip replacement: A review of the Swedish THR Register comparing 160,000 cases
-
Herberts P, Malchau H. 2000. Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases. Acta Orthop Scand 71:111-121.
-
(2000)
Acta Orthop Scand
, vol.71
, pp. 111-121
-
-
Herberts, P.1
Malchau, H.2
-
6
-
-
0030668935
-
Factors affecting aseptic failure of fixation after primary charnley total hip arthroplasty: Multivariate survival analysis
-
Kobayashi S, Takaoka K, Saito N, et al. 1997. Factors affecting aseptic failure of fixation after primary charnley total hip arthroplasty: multivariate survival analysis. J Bone Joint Surg Am 79:1618-1627.
-
(1997)
J Bone Joint Surg Am
, vol.79
, pp. 1618-1627
-
-
Kobayashi, S.1
Takaoka, K.2
Saito, N.3
-
7
-
-
0036312327
-
Fatigue crack growth rate does not depend on mantle thickness: An idealized cemented stem constructed under torsional loading
-
Hertzler J, Miller MA, Mann KA. 2002. Fatigue crack growth rate does not depend on mantle thickness: an idealized cemented stem constructed under torsional loading. J Orthop Res 20:676-682.
-
(2002)
J Orthop Res
, vol.20
, pp. 676-682
-
-
Hertzler, J.1
Miller, M.A.2
Mann, K.A.3
-
8
-
-
0025784682
-
The initiation of failure in cemented femoral components of hip arthroplasties
-
Jasty M, Maloney WJ, Bragdon CR, et al. 1991. The initiation of failure in cemented femoral components of hip arthroplasties. J Bone Joint Surg Br 73:551-558.
-
(1991)
J Bone Joint Surg Br
, vol.73
, pp. 551-558
-
-
Jasty, M.1
Maloney, W.J.2
Bragdon, C.R.3
-
9
-
-
0032897980
-
Microdamage accumulation in the cement layer of hip replacements under flexural loading
-
McCormack BAO, Prendergast PJ. 1999. Microdamage accumulation in the cement layer of hip replacements under flexural loading. J Biomech 32:467-475.
-
(1999)
J Biomech
, vol.32
, pp. 467-475
-
-
McCormack, B.A.O.1
Prendergast, P.J.2
-
10
-
-
0344838428
-
Can finite element models detect clinically inferior cemented hip implants?
-
Stolk J, Maher SA, Verdonschot N, et al. 2003. Can finite element models detect clinically inferior cemented hip implants? Clin Orthop 409:138-150.
-
(2003)
Clin Orthop
, vol.409
, pp. 138-150
-
-
Stolk, J.1
Maher, S.A.2
Verdonschot, N.3
-
11
-
-
0038681344
-
The influence of stem insertion rate on the porosity of the cement mantle of hip joint replacements
-
Baleani M, Fognani R, Toni A. 2003. The influence of stem insertion rate on the porosity of the cement mantle of hip joint replacements. Proc Inst Mech Eng [H] 217:199-205.
-
(2003)
Proc Inst Mech Eng [H]
, vol.217
, pp. 199-205
-
-
Baleani, M.1
Fognani, R.2
Toni, A.3
-
12
-
-
0029941585
-
Porosity reduction in bone cement at the cement-stem interface
-
Bishop NE, Ferguson S, Tepic S. 1996. Porosity reduction in bone cement at the cement-stem interface. J Bone Joint Surg Br 78:349-357.
-
(1996)
J Bone Joint Surg Br
, vol.78
, pp. 349-357
-
-
Bishop, N.E.1
Ferguson, S.2
Tepic, S.3
-
13
-
-
25844516621
-
The effects of fluid penetration and interfacial porosity on the fixation of cemented femoral components
-
Iesaka K, Jaffe WL, Jones CM, et al. 2005. The effects of fluid penetration and interfacial porosity on the fixation of cemented femoral components. J Bone Joint Surg Br 87: 1298-1302.
-
(2005)
J Bone Joint Surg Br
, vol.87
, pp. 1298-1302
-
-
Iesaka, K.1
Jaffe, W.L.2
Jones, C.M.3
-
14
-
-
0037362675
-
Effects of preheating of hip prostheses on the stem-cement interface
-
Iesaka K, Jaffe WL, Kummer FJ. 2003. Effects of preheating of hip prostheses on the stem-cement interface. J Bone Joint Surg Am 85:421-427.
-
(2003)
J Bone Joint Surg Am
, vol.85
, pp. 421-427
-
-
Iesaka, K.1
Jaffe, W.L.2
Kummer, F.J.3
-
15
-
-
0027535641
-
Extensive porosity at the cement-femoral prosthesis interface: A preliminary study
-
James SP, Schmalzried TP, McGarry FJ, et al. 1993. Extensive porosity at the cement-femoral prosthesis interface: a preliminary study. J Biomed Mater Res 27: 71-78.
-
(1993)
J Biomed Mater Res
, vol.27
, pp. 71-78
-
-
James, S.P.1
Schmalzried, T.P.2
McGarry, F.J.3
-
16
-
-
85031235817
-
Commentary and perspective: Effects of preheating of hip prostheses on the stem-cement interface
-
eJBJS, commentary and perspective
-
Salvati E, Wright T. 2003. Commentary and perspective: effects of preheating of hip prostheses on the stem-cement interface. J Bone Joint Surg. eJBJS, commentary and perspective: www.jbjs.org/comments2003/ cp-marO3-salvati.shtml.
-
(2003)
J Bone Joint Surg
-
-
Salvati, E.1
Wright, T.2
-
17
-
-
0032788247
-
Interface gap after implantation of a cemented femoral stem in pigs
-
Wang JS, Franzen H, Lidgren L. 1999. Interface gap after implantation of a cemented femoral stem in pigs. Acta Orthop Scand 70:234-239.
-
(1999)
Acta Orthop Scand
, vol.70
, pp. 234-239
-
-
Wang, J.S.1
Franzen, H.2
Lidgren, L.3
-
18
-
-
0036856326
-
The influence of surface roughness on stem-cement gaps
-
Race A, Miller MA, Ayers DC, et al. 2002. The influence of surface roughness on stem-cement gaps. J Bone Joint Surg Br 84:1199-1204.
-
(2002)
J Bone Joint Surg Br
, vol.84
, pp. 1199-1204
-
-
Race, A.1
Miller, M.A.2
Ayers, D.C.3
-
19
-
-
0036316205
-
Reliability of detecting prosthesis/cement interface radiolucencies in total hip arthroplasty
-
Zhang Y, Putnam AW, Heiner AD, et al. 2002. Reliability of detecting prosthesis/cement interface radiolucencies in total hip arthroplasty. J Orthop Res 20:683-687.
-
(2002)
J Orthop Res
, vol.20
, pp. 683-687
-
-
Zhang, Y.1
Putnam, A.W.2
Heiner, A.D.3
-
20
-
-
27644501807
-
Cement/implant interface gaps explain the poor results of CMW3 for femoral stem fixation: A cadaver study of migration, fatigue and mantle morphology
-
Race A, Miller MA, Clarke MT, et al. 2005. Cement/implant interface gaps explain the poor results of CMW3 for femoral stem fixation: a cadaver study of migration, fatigue and mantle morphology. Acta Orthop 5:679-687.
-
(2005)
Acta Orthop
, vol.5
, pp. 679-687
-
-
Race, A.1
Miller, M.A.2
Clarke, M.T.3
-
21
-
-
0037397195
-
Early cement damage around a femoral stem is concentrated at the cement /bone interface
-
Race A, Miller MA, Ayers DC, et al. 2003. Early cement damage around a femoral stem is concentrated at the cement/bone interface. J Biomech 36:489-496.
-
(2003)
J Biomech
, vol.36
, pp. 489-496
-
-
Race, A.1
Miller, M.A.2
Ayers, D.C.3
-
22
-
-
0343881229
-
Implant stability in revision THA: The role of allograft packing and cementing
-
Berzins A, Waslielewski RC, Sumner DR. 1993. Implant stability in revision THA: the role of allograft packing and cementing. Trans Orthop Res Soc 18:518.
-
(1993)
Trans Orthop Res Soc
, vol.18
, pp. 518
-
-
Berzins, A.1
Waslielewski, R.C.2
Sumner, D.R.3
-
23
-
-
0036901462
-
The effect of anteversion on femoral component stability assessed by radiostereometric analysis
-
Gill HS, Alfaro-Adrian J, Alfaro-Adrian C, et al. 2002. The effect of anteversion on femoral component stability assessed by radiostereometric analysis. J Arthroplasty 17:997-1005.
-
(2002)
J Arthroplasty
, vol.17
, pp. 997-1005
-
-
Gill, H.S.1
Alfaro-Adrian, J.2
Alfaro-Adrian, C.3
-
24
-
-
0037709392
-
Application of circular statistics in the study of crack distribution around cemented femoral components
-
Mann KA, Gupta S, Race A, et al. 2003. Application of circular statistics in the study of crack distribution around cemented femoral components. J Biomech 36:1231-1234.
-
(2003)
J Biomech
, vol.36
, pp. 1231-1234
-
-
Mann, K.A.1
Gupta, S.2
Race, A.3
-
25
-
-
0029361235
-
Coulomb frictional interfaces in modeling cemented total hip replacements: A more realistic model
-
Mann KA, Bartel DL, Wright TM, et al. 1995. Coulomb frictional interfaces in modeling cemented total hip replacements: a more realistic model. J Biomech 28: 1067-1078.
-
(1995)
J Biomech
, vol.28
, pp. 1067-1078
-
-
Mann, K.A.1
Bartel, D.L.2
Wright, T.M.3
-
26
-
-
0036000232
-
Residual stresses at the stem-cement interface of an idealized cemented hip stem
-
Nuno N, Avanzolini G. 2002. Residual stresses at the stem-cement interface of an idealized cemented hip stem. J Biomech 35:849-852.
-
(2002)
J Biomech
, vol.35
, pp. 849-852
-
-
Nuno, N.1
Avanzolini, G.2
-
27
-
-
0031172484
-
Properties of acrylic bone cement: State of the art review
-
Lewis G. 1997. Properties of acrylic bone cement: state of the art review. J Biomed Mater Res 38:155-182.
-
(1997)
J Biomed Mater Res
, vol.38
, pp. 155-182
-
-
Lewis, G.1
-
28
-
-
1642580585
-
In vivo surface wear mechanisms of femoral components of cemented total hip arthroplasties: The influence of wear mechanism on clinical outcome
-
Howell JR Jr, Blunt LA, Doyle C, et al. 2004. In vivo surface wear mechanisms of femoral components of cemented total hip arthroplasties: the influence of wear mechanism on clinical outcome. J Arthroplasty 19:88-101.
-
(2004)
J Arthroplasty
, vol.19
, pp. 88-101
-
-
Howell Jr., J.R.1
Blunt, L.A.2
Doyle, C.3
-
29
-
-
0030039968
-
Radiographic risk signs for loosening after cemented THA: 61 loose stems and 23 loose sockets compared with 42 controls
-
Stromberg CN, Herberts P, Palmertz B, et al. 1996. Radiographic risk signs for loosening after cemented THA: 61 loose stems and 23 loose sockets compared with 42 controls. Acta Orthop Scand 67:43-48.
-
(1996)
Acta Orthop Scand
, vol.67
, pp. 43-48
-
-
Stromberg, C.N.1
Herberts, P.2
Palmertz, B.3
-
30
-
-
0033372584
-
Increased migration of the SHP prosthesis: Radiostereometric comparison with the Lubinus SP2 design in 40 cases
-
Nivbrant B, Karrholm J, Soderlund P. 1999. Increased migration of the SHP prosthesis: radiostereometric comparison with the Lubinus SP2 design in 40 cases. Acta Orthop Scand 70:569-577.
-
(1999)
Acta Orthop Scand
, vol.70
, pp. 569-577
-
-
Nivbrant, B.1
Karrholm, J.2
Soderlund, P.3
-
31
-
-
0034255618
-
A theoretical and experimental analysis of polymerization shrinkage of bone cement: A potential major source of porosity
-
Gilbert JL, Hasenwinkel JM, Wixson RL, et al. 2000. A theoretical and experimental analysis of polymerization shrinkage of bone cement: a potential major source of porosity. J Biomed Mater Res 52:210-218.
-
(2000)
J Biomed Mater Res
, vol.52
, pp. 210-218
-
-
Gilbert, J.L.1
Hasenwinkel, J.M.2
Wixson, R.L.3
-
32
-
-
27644560038
-
A source of interfacial pore formation in cemented femoral components
-
Spiegelberg S, McKinley G. 1999. A source of interfacial pore formation in cemented femoral components. Trans Ortho Res Soc 24:253.
-
(1999)
Trans Ortho Res Soc
, vol.24
, pp. 253
-
-
Spiegelberg, S.1
McKinley, G.2
-
33
-
-
33646376187
-
A comparative FEA of the debonding process in different concepts of cemented hip implants
-
Perez MA, Garcia-Aznar JM, Doblare M, et al. 2006. A comparative FEA of the debonding process in different concepts of cemented hip implants. Med Eng Phys 28:525-533.
-
(2006)
Med Eng Phys
, vol.28
, pp. 525-533
-
-
Perez, M.A.1
Garcia-Aznar, J.M.2
Doblare, M.3
-
34
-
-
0036528664
-
Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry
-
Collis DK, Mohler CG. 2002. Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry. J Bone Joint Surg Am 84:586-592.
-
(2002)
J Bone Joint Surg Am
, vol.84
, pp. 586-592
-
-
Collis, D.K.1
Mohler, C.G.2
-
35
-
-
21844474079
-
A rough surface finish adversely affects the survivorship of a cemented femoral stem
-
Della Vallee AMG, Zoppi A, Peterson MGE, et al. 2005. A rough surface finish adversely affects the survivorship of a cemented femoral stem. Clin Orthop 436:158-163.
-
(2005)
Clin Orthop
, vol.436
, pp. 158-163
-
-
Della Vallee, A.M.G.1
Zoppi, A.2
Peterson, M.G.E.3
-
36
-
-
0036562948
-
Early failure of precoated femoral components in primary total hip arthroplasty
-
Ong A, Wong KL, Lai M, et al. 2002. Early failure of precoated femoral components in primary total hip arthroplasty. J Bone Joint Surg Am 84:786-792.
-
(2002)
J Bone Joint Surg Am
, vol.84
, pp. 786-792
-
-
Ong, A.1
Wong, K.L.2
Lai, M.3
-
37
-
-
0032947562
-
The effects of surface roughness and polymethylmethacrylate precoating on the radiographic and clinical results of the Iowa hip prosthesis. A study of patients less than fifty years old
-
Sporer SM, Callaghan JJ, Olejniczak JP, et al. 1999. The effects of surface roughness and polymethylmethacrylate precoating on the radiographic and clinical results of the Iowa hip prosthesis. A study of patients less than fifty years old. J Bone Joint Surg Am 81:481-492.
-
(1999)
J Bone Joint Surg Am
, vol.81
, pp. 481-492
-
-
Sporer, S.M.1
Callaghan, J.J.2
Olejniczak, J.P.3
|