-
1
-
-
0034018334
-
Robotics and telemanipulation technologies for endoscopic surgery. A review of the ARTEMIS project
-
Schurr MO. Robotics and telemanipulation technologies for endoscopic surgery. A review of the ARTEMIS project. Surg Endosc 2000;14:375-381.
-
(2000)
Surg Endosc
, vol.14
, pp. 375-381
-
-
Schurr, M.O.1
-
3
-
-
0347409401
-
Biomimetic Propulsion for a Swimming Surgical Micro-Robot
-
Las Vegas, NV
-
Edd J, Payen S, Rubinsky B, Stoller ML, Sitti M. Biomimetic Propulsion for a Swimming Surgical Micro-Robot. In IEEE International Conference on Intelligent Robots and Systems, Las Vegas, NV, 2003,2583-2588.
-
(2003)
IEEE International Conference on Intelligent Robots and Systems
, pp. 2583-2588
-
-
Edd, J.1
Payen, S.2
Rubinsky, B.3
Stoller, M.L.4
Sitti, M.5
-
4
-
-
33646348194
-
Design methodology for biomimetic propulsion of miniature swimming robots
-
Behkam B, Sitti M. Design methodology for biomimetic propulsion of miniature swimming robots. J Dynamic Systems Meas Control Trans ASME 2006;128:36-43.
-
(2006)
J Dynamic Systems Meas Control Trans ASME
, vol.128
, pp. 36-43
-
-
Behkam, B.1
Sitti, M.2
-
5
-
-
33947324356
-
Automatic navigation of an untethered device in the artery of a living animal using a conventional clinical magnetic resonance imaging system
-
Martel S, Mathieu J-B, Felfoul O, Chanu A, Aboussouan E, Tamaz S, Pouponneau P, Yahia LH, Beaudoin G, Soulez G, Mankiewicz M. Automatic navigation of an untethered device in the artery of a living animal using a conventional clinical magnetic resonance imaging system. App Phys Lett 2007;90: 114105.
-
(2007)
App Phys Lett
, vol.90
, pp. 114105
-
-
Martel, S.1
Mathieu, J.-B.2
Felfoul, O.3
Chanu, A.4
Aboussouan, E.5
Tamaz, S.6
Pouponneau, P.7
Yahia, L.H.8
Beaudoin, G.9
Soulez, G.10
Mankiewicz, M.11
-
6
-
-
24944452593
-
Preliminary investigation of the feasibility of magnetic propulsion for future microdevices in blood vessels
-
Mathieu J-B, Martel S, Yahia LH, Soulez G, Beaudoin G. Preliminary investigation of the feasibility of magnetic propulsion for future microdevices in blood vessels. Bio-Medical Mater Eng 2005;15:367-374.
-
(2005)
Bio-Medical Mater Eng
, vol.15
, pp. 367-374
-
-
Mathieu, J.-B.1
Martel, S.2
Yahia, L.H.3
Soulez, G.4
Beaudoin, G.5
-
7
-
-
45749138836
-
Real-time MRI-based control of a ferromagnetic core for endovascular navigation
-
Tamaz S, Gourdeau R, Chanu A, Mathieu J-B, Martel S. Real-time MRI-based control of a ferromagnetic core for endovascular navigation. IEEE Transactis Biomed Eng 2008; 55:1854-1863.
-
(2008)
IEEE Transactis Biomed Eng
, vol.55
, pp. 1854-1863
-
-
Tamaz, S.1
Gourdeau, R.2
Chanu, A.3
Mathieu, J.-B.4
Martel, S.5
-
9
-
-
18144432070
-
Mathematical modelling of magnetically targeted drug delivery
-
Grief AD, Richardson G. Mathematical modelling of magnetically targeted drug delivery. J Magn Magn Mater 2005;293: 455-463.
-
(2005)
J Magn Magn Mater
, vol.293
, pp. 455-463
-
-
Grief, A.D.1
Richardson, G.2
-
10
-
-
20644466657
-
Near equiatomic FeCo alloys: Constitution, mechanical and magnetic properties
-
Sourmail T. Near equiatomic FeCo alloys: Constitution, mechanical and magnetic properties. Prog Mater Sci 2005;50: 816-880.
-
(2005)
Prog Mater Sci
, vol.50
, pp. 816-880
-
-
Sourmail, T.1
-
12
-
-
1542788006
-
An in vitro study into the corrosion of intra-oral magnets in the presence of dental amalgam
-
Noar JH, Evans RD, Wilson D, Costello J, Ioannou E, Ayeni A, Mordan NJ, Wilson M, Pratten J. An in vitro study into the corrosion of intra-oral magnets in the presence of dental amalgam. Eur J Orthod 2003;25:615-619.
-
(2003)
Eur J Orthod
, vol.25
, pp. 615-619
-
-
Noar, J.H.1
Evans, R.D.2
Wilson, D.3
Costello, J.4
Ioannou, E.5
Ayeni, A.6
Mordan, N.J.7
Wilson, M.8
Pratten, J.9
-
13
-
-
0033090919
-
Rare earth magnets in orthodontics: An overview
-
Noar JH, Evans RD. Rare earth magnets in orthodontics: An overview. Br J Orthod 1999;26:29-37.
-
(1999)
Br J Orthod
, vol.26
, pp. 29-37
-
-
Noar, J.H.1
Evans, R.D.2
-
14
-
-
0033873962
-
Thermical hysteresis loop of the alloys having Fe, Ni content used for magnetic sensors
-
Preotu M, Filip D, Predeanu S, Tomorug A, Carciuleanu E, Ghitescu S. Thermical hysteresis loop of the alloys having Fe, Ni content used for magnetic sensors. Sens Actuators A Phys 2000;81:232-235.
-
(2000)
Sens Actuators A Phys
, vol.81
, pp. 232-235
-
-
Preotu, M.1
Filip, D.2
Predeanu, S.3
Tomorug, A.4
Carciuleanu, E.5
Ghitescu, S.6
-
16
-
-
0033691906
-
50.50 FeNi permalloy with Ti and Cr additions for improved hardness and corrosion resistance
-
Coutu L, Chaput L, Waeckerle T. 50.50 FeNi permalloy with Ti and Cr additions for improved hardness and corrosion resistance. J Magn Magn Mater 2000;215:237-239.
-
(2000)
J Magn Magn Mater
, vol.215
, pp. 237-239
-
-
Coutu, L.1
Chaput, L.2
Waeckerle, T.3
-
17
-
-
0017533028
-
50 Permalloy alloyed with Cr for increased corrosion resistance
-
Eriksson H, Salwen A. 50 Permalloy alloyed with Cr for increased corrosion resistance. IEEE Transactis Magn 1977; 13:1451-1453.
-
(1977)
IEEE Transactis Magn
, vol.13
, pp. 1451-1453
-
-
Eriksson, H.1
Salwen, A.2
-
18
-
-
0036543816
-
Ferromagnetic properties of cold rolled AISI 304L steel
-
Tavares SSM, Da Silva MR, Neto JM, Miraglia S, Fruchart D. Ferromagnetic properties of cold rolled AISI 304L steel. J Magn Magn Mater 2002;242:1391-1394.
-
(2002)
J Magn Magn Mater
, vol.242
, pp. 1391-1394
-
-
Tavares, S.S.M.1
Da Silva, M.R.2
Neto, J.M.3
Miraglia, S.4
Fruchart, D.5
-
19
-
-
33646583231
-
Effect of surface preparation on the evolution of the passive films formed on AISI 304L
-
Abreu CM, Cristobal MJ, Losada R, Novoa XR, Pena G, Perez MC. Effect of surface preparation on the evolution of the passive films formed on AISI 304L. Surf Interface Anal 2006;38:259-262.
-
(2006)
Surf Interface Anal
, vol.38
, pp. 259-262
-
-
Abreu, C.M.1
Cristobal, M.J.2
Losada, R.3
Novoa, X.R.4
Pena, G.5
Perez, M.C.6
-
20
-
-
14044272787
-
Effect of texture on corrosion behavior of AISI 304L stainless steel
-
Kumar BR, Singh R, Mahato B, De PK, Bandyopadhyay NR, Bhattacharya DK. Effect of texture on corrosion behavior of AISI 304L stainless steel. Mater Charact 2005;54:141-147.
-
(2005)
Mater Charact
, vol.54
, pp. 141-147
-
-
Kumar, B.R.1
Singh, R.2
Mahato, B.3
De, P.K.4
Bandyopadhyay, N.R.5
Bhattacharya, D.K.6
-
21
-
-
77949501437
-
-
Vacuumschmelze. Soft Magnetic Cobalt-Iron alloys, Available at: http://www.vacuumschmelze.de/dynamic/docroot/medialib/ documents/broschueren/ htbrosch/Pht-004-e.pdf. Last assessed: 16 April 2009.
-
Vacuumschmelze. Soft Magnetic Cobalt-Iron alloys, Available at: http://www.vacuumschmelze.de/dynamic/docroot/medialib/ documents/broschueren/ htbrosch/Pht-004-e.pdf. Last assessed: 16 April 2009.
-
-
-
-
22
-
-
77949498037
-
-
American Society for Testing and Materials. Annual Book of ASTM standard. Philadelphia: American Society for Testing and Materials; 2000.
-
American Society for Testing and Materials. Annual Book of ASTM standard. Philadelphia: American Society for Testing and Materials; 2000.
-
-
-
-
23
-
-
0033339176
-
Analytical performance of axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS)
-
Tian X, Emteborg H, Adams FC. Analytical performance of axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS). J Anal At Spectrom 1999;14:1807-1814.
-
(1999)
J Anal At Spectrom
, vol.14
, pp. 1807-1814
-
-
Tian, X.1
Emteborg, H.2
Adams, F.C.3
-
24
-
-
16444375995
-
A comparative study of the in vitro corrosion behavior and cytotoxicity of a superferritic stainless steel, a Ti-13Nb-13Zr alloy, and an austenitic stainless steel in Hank's solution
-
Assis SL, Rogero SO, Antunes RA, Padilha AF, Costa I. A comparative study of the in vitro corrosion behavior and cytotoxicity of a superferritic stainless steel, a Ti-13Nb-13Zr alloy, and an austenitic stainless steel in Hank's solution. J Biomed Mater Res B App Biomater 2005;73:109-116.
-
(2005)
J Biomed Mater Res B App Biomater
, vol.73
, pp. 109-116
-
-
Assis, S.L.1
Rogero, S.O.2
Antunes, R.A.3
Padilha, A.F.4
Costa, I.5
-
25
-
-
0031172794
-
Electrochemical and surface modifications of N+-ion-implanted 316L stainless steel
-
Leitao E, Silva RA, Barbosa MA. Electrochemical and surface modifications of N+-ion-implanted 316L stainless steel. J Mater Sci Mater Med 1997;8:365-368.
-
(1997)
J Mater Sci Mater Med
, vol.8
, pp. 365-368
-
-
Leitao, E.1
Silva, R.A.2
Barbosa, M.A.3
-
26
-
-
13444304224
-
Corrosion behaviour of cobalt-chromium dental alloys doped with precious metals
-
Reclaru L, Luthy H, Eschler P-Y, Blatter A, Susz C. Corrosion behaviour of cobalt-chromium dental alloys doped with precious metals. Biomaterials 2005;26:4358-4365.
-
(2005)
Biomaterials
, vol.26
, pp. 4358-4365
-
-
Reclaru, L.1
Luthy, H.2
Eschler, P.-Y.3
Blatter, A.4
Susz, C.5
-
27
-
-
1342264209
-
Passive and transpassive behaviour of CoCrMo in simulated biological solutions
-
Hodgson AWE, Kurz S, Virtanen S, Fervel V, Olsson C-OA, Mischler S. Passive and transpassive behaviour of CoCrMo in simulated biological solutions. Electrochim Acta 2004;49: 2167-2178.
-
(2004)
Electrochim Acta
, vol.49
, pp. 2167-2178
-
-
Hodgson, A.W.E.1
Kurz, S.2
Virtanen, S.3
Fervel, V.4
Olsson, C.-O.A.5
Mischler, S.6
-
29
-
-
0036464446
-
Corrosion studies related to suitability of permanent magnets for biomedical applications
-
Gurrappa I. Corrosion studies related to suitability of permanent magnets for biomedical applications. Mater Charact 2002;48:63-70.
-
(2002)
Mater Charact
, vol.48
, pp. 63-70
-
-
Gurrappa, I.1
-
30
-
-
30744459403
-
Corrosion characterization of titanium alloys by electrochemical techniques
-
De Assis SL, Wolynec S, Costa I. Corrosion characterization of titanium alloys by electrochemical techniques. Electrochim Acta 2006;51:1815-1819.
-
(2006)
Electrochim Acta
, vol.51
, pp. 1815-1819
-
-
De Assis, S.L.1
Wolynec, S.2
Costa, I.3
-
31
-
-
14844303563
-
A study on the localized corrosion of cobalt in bicarbonate solutions containing halide ions
-
Gallant D, Simard S. A study on the localized corrosion of cobalt in bicarbonate solutions containing halide ions. Corros Sci 2005;47:1810-1838.
-
(2005)
Corros Sci
, vol.47
, pp. 1810-1838
-
-
Gallant, D.1
Simard, S.2
-
32
-
-
34047097522
-
Biocompatibility of candidate materials for the realization of medical microdevices
-
New York, NY
-
Pouponneau P, Yahia LH, Merhi Y, Epure LM, Martel S. Biocompatibility of candidate materials for the realization of medical microdevices. Annual International Conference of the IEEE Engineering in Medicine and Biology, New York, NY, 2006,2362-2365.
-
(2006)
Annual International Conference of the IEEE Engineering in Medicine and Biology
, pp. 2362-2365
-
-
Pouponneau, P.1
Yahia, L.H.2
Merhi, Y.3
Epure, L.M.4
Martel, S.5
-
33
-
-
0345708222
-
Cobalt and antimony: Genotoxicity and carcinogenicity
-
De Boeck M, Kirsch-Volders M, Lison D. Cobalt and antimony: Genotoxicity and carcinogenicity. Mutat Res 2003;533: 135-152.
-
(2003)
Mutat Res
, vol.533
, pp. 135-152
-
-
De Boeck, M.1
Kirsch-Volders, M.2
Lison, D.3
-
36
-
-
0032052665
-
Neoplastic transformation of cells by soluble but not particulate forms of metals used in orthopaedic implants
-
Doran A, Law FC, Allen MJ, Rushton N. Neoplastic transformation of cells by soluble but not particulate forms of metals used in orthopaedic implants. Biomaterials 1998;19:751-759.
-
(1998)
Biomaterials
, vol.19
, pp. 751-759
-
-
Doran, A.1
Law, F.C.2
Allen, M.J.3
Rushton, N.4
-
37
-
-
0036903250
-
Enhancement of iron toxicity in L929 cells by D-glucose: Accelerated (re-)reduction
-
Lehnen-Beyel I, Groot HD, Rauen U. Enhancement of iron toxicity in L929 cells by D-glucose: Accelerated (re-)reduction. Biochem J 2002;368:517-526.
-
(2002)
Biochem J
, vol.368
, pp. 517-526
-
-
Lehnen-Beyel, I.1
Groot, H.D.2
Rauen, U.3
-
41
-
-
0029360622
-
Chromium accumulation and ultrastructural changes in the mouse liver caused by stainless steel corrosion products
-
Pereira ML, Abreu AM, Sousa JP, Carvalho GS. Chromium accumulation and ultrastructural changes in the mouse liver caused by stainless steel corrosion products. J Mater Sci Mater Med 1995;6:523-527.
-
(1995)
J Mater Sci Mater Med
, vol.6
, pp. 523-527
-
-
Pereira, M.L.1
Abreu, A.M.2
Sousa, J.P.3
Carvalho, G.S.4
-
42
-
-
0013430807
-
Corrosion resistance and corrosion fatigue strength of new titanium alloys for medical implants without V and Al
-
Okazaki Y, Ito Y, Kyo K, Tateishi T. Corrosion resistance and corrosion fatigue strength of new titanium alloys for medical implants without V and Al. Mater Sci Eng A 1996;213:138-147.
-
(1996)
Mater Sci Eng A
, vol.213
, pp. 138-147
-
-
Okazaki, Y.1
Ito, Y.2
Kyo, K.3
Tateishi, T.4
-
43
-
-
50349085604
-
A study about the bio-compatibility of Ti-8Ta-3Nb alloys with surface modification
-
Ahn H, Lee D, Moon C-W, Lee K-M, Lee K. A study about the bio-compatibility of Ti-8Ta-3Nb alloys with surface modification. Surf Coat Technol 2008;202:5779-5783.
-
(2008)
Surf Coat Technol
, vol.202
, pp. 5779-5783
-
-
Ahn, H.1
Lee, D.2
Moon, C.-W.3
Lee, K.-M.4
Lee, K.5
-
45
-
-
4344717839
-
Blood compatibility of titanium-based coatings prepared by metal plasma immersion ion implantation and deposition
-
Tsyganov I, Maitz MF, Wieser E. Blood compatibility of titanium-based coatings prepared by metal plasma immersion ion implantation and deposition. Appl Surf Sci 2004;235:156-163.
-
(2004)
Appl Surf Sci
, vol.235
, pp. 156-163
-
-
Tsyganov, I.1
Maitz, M.F.2
Wieser, E.3
-
46
-
-
0033249821
-
The durability of parylene coatings on neodymium-iron-boron magnets
-
Noar JH, Wahab A, Evans RD, Wojcik AG. The durability of parylene coatings on neodymium-iron-boron magnets. Eur J Orthod 1999;21:685-693.
-
(1999)
Eur J Orthod
, vol.21
, pp. 685-693
-
-
Noar, J.H.1
Wahab, A.2
Evans, R.D.3
Wojcik, A.G.4
-
47
-
-
23044516341
-
-
Haidopoulos M, Turgeon S, Laroche G, Mantovani D. Chemical and morphological characterization of ultra-thin fluorocarbon plasma-polymer deposition on 316 stainless steel substrates: A first step toward the improvement of the longterm safety of coated-stents. Plasma Processes Polym 2005;2: 424-440.
-
Haidopoulos M, Turgeon S, Laroche G, Mantovani D. Chemical and morphological characterization of ultra-thin fluorocarbon plasma-polymer deposition on 316 stainless steel substrates: A first step toward the improvement of the longterm safety of coated-stents. Plasma Processes Polym 2005;2: 424-440.
-
-
-
-
48
-
-
28544451357
-
Surface modification of coronary artery stent by Ti-O/Ti-N complex film coating prepared with plasma immersion ion implantation and deposition
-
Huang N, Leng YX, Yang P, Chen JY, Sun H, Wang J, Wan GJ, Zhao AS, Ding PD. Surface modification of coronary artery stent by Ti-O/Ti-N complex film coating prepared with plasma immersion ion implantation and deposition. Nucl Instrum Methods Phys Res Sect B 2006; 242:18-21.
-
(2006)
Nucl Instrum Methods Phys Res Sect B
, vol.242
, pp. 18-21
-
-
Huang, N.1
Leng, Y.X.2
Yang, P.3
Chen, J.Y.4
Sun, H.5
Wang, J.6
Wan, G.J.7
Zhao, A.S.8
Ding, P.D.9
-
49
-
-
19944384939
-
Surface treatment on an implant cobalt alloy for high biocompatibility and wear resistance
-
Spriano S, Verne E, Faga MG, Bugliosi S, Maina G. Surface treatment on an implant cobalt alloy for high biocompatibility and wear resistance. Wear 2005;259:919-925.
-
(2005)
Wear
, vol.259
, pp. 919-925
-
-
Spriano, S.1
Verne, E.2
Faga, M.G.3
Bugliosi, S.4
Maina, G.5
|