메뉴 건너뛰기




Volumn , Issue , 2006, Pages 2362-2365

Biocompatibility of candidate materials for the realization of medical microdevices

Author keywords

Biocompatibility; Fe Co alloys; Medical microdevices; MTT test; Single crystal Ni Mn Ga; Terfenol D

Indexed keywords

FE-CO ALLOYS; MEDICAL MICRODEVICES; MTT TEST; SINGLE CRYSTAL NI-MN-GA; TERFENOL-D;

EID: 34047097522     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2006.260061     Document Type: Conference Paper
Times cited : (11)

References (12)
  • 1
    • 24944452593 scopus 로고    scopus 로고
    • J.-B. Mathieu, S, Martel, L.Yahia, G. Soulez, and G. Beaudoin, G., Preliminary investigation of the feasibility of magnetic propulsion for future microdevices in blood vessels Bio-Medical Materials and Engineering, 15, no. 5, pp. 367-374, 2005.
    • J.-B. Mathieu, S, Martel, L.Yahia, G. Soulez, and G. Beaudoin, G., "Preliminary investigation of the feasibility of magnetic propulsion for future microdevices in blood vessels" Bio-Medical Materials and Engineering, vol. 15, no. 5, pp. 367-374, 2005.
  • 3
    • 0037089638 scopus 로고    scopus 로고
    • Al-Cu-Fe quasicrystal/ultra-high molecular weight polyethylene composites as biomaterials for acetabular cup prosthetics
    • B. C. Anderson, P. D. Bloom, V. V. Sheares, S. K Mallapragada, and K. G Baikerikar, "Al-Cu-Fe quasicrystal/ultra-high molecular weight polyethylene composites as biomaterials for acetabular cup prosthetics" Biomaterials, vol. 23, no. 8, pp. 1761-1768, 2002
    • (2002) Biomaterials , vol.23 , Issue.8 , pp. 1761-1768
    • Anderson, B.C.1    Bloom, P.D.2    Sheares, V.V.3    Mallapragada, S.K.4    Baikerikar, K.G.5
  • 4
    • 0007932053 scopus 로고
    • Biological evaluation of medical devices - Part 5 : Tests for cytotoxicity : in vitro methods
    • Association for the Advancement of Medical Instrumentation, ANSI/AAMI/ISO
    • Association for the Advancement of Medical Instrumentation, "Biological evaluation of medical devices - Part 5 : Tests for cytotoxicity : in vitro methods", Organisation internationale de normalisation, ANSI/AAMI/ISO 10993-5, 1993.
    • (1993) Organisation internationale de normalisation , pp. 10993-10995
  • 5
    • 0021061819 scopus 로고
    • Rapid colorimetric assay for cellular growth and survival: Application to proliferation and cytotoxicity assays
    • Dec 16
    • T. Mosmann, "Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays" J Immunol Methods, vol. 65, pp. 55-63, Dec 16, 1983.
    • (1983) J Immunol Methods , vol.65 , pp. 55-63
    • Mosmann, T.1
  • 6
    • 33644994476 scopus 로고    scopus 로고
    • Effect of cobalt and chromium ions on human MG-63 osteoblasts in vitro: Morphology, cytotoxicity, and oxidative stress
    • Jun
    • C. Fleury, A. Petit, F. Mwale, J. Antoniou, D. J. Zukor, M. Tabrizian, and O. L. Huk, "Effect of cobalt and chromium ions on human MG-63 osteoblasts in vitro: morphology, cytotoxicity, and oxidative stress" Biomaterials, vol. 27, pp. 3351-60, Jun, 2006.
    • (2006) Biomaterials , vol.27 , pp. 3351-3360
    • Fleury, C.1    Petit, A.2    Mwale, F.3    Antoniou, J.4    Zukor, D.J.5    Tabrizian, M.6    Huk, O.L.7
  • 7
    • 0033984351 scopus 로고    scopus 로고
    • In vitro cytotoxicity of various forms of cobalt for rat alveolar macrophages and type II pneumocytes
    • Jan 1
    • G. Roesems, P. H. Hoet, D. Dinsdale, M. Demedts, and B. Nemery, "In vitro cytotoxicity of various forms of cobalt for rat alveolar macrophages and type II pneumocytes" Toxicol Appl Pharmacol, vol. 162, pp. 2-9, Jan 1, 2000.
    • (2000) Toxicol Appl Pharmacol , vol.162 , pp. 2-9
    • Roesems, G.1    Hoet, P.H.2    Dinsdale, D.3    Demedts, M.4    Nemery, B.5
  • 8
    • 0032943419 scopus 로고    scopus 로고
    • Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cells in vitro
    • J. C. Wataha, P. E. Lockwood, M. Marek, and M. Ghazi, "Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cells in vitro" Journal of Biomedical Materials Research, vol. 45, no. 3, pp. 251-257, 1999
    • (1999) Journal of Biomedical Materials Research , vol.45 , Issue.3 , pp. 251-257
    • Wataha, J.C.1    Lockwood, P.E.2    Marek, M.3    Ghazi, M.4
  • 9
    • 1942508938 scopus 로고    scopus 로고
    • Unidirectional magnetostrictive Terfenol/epoxy composite
    • J. C. Kim, O. Y. Kwon, and Z. H. Lee, "Unidirectional magnetostrictive Terfenol/epoxy composite" Applied Physics Letters, vol. 84, no. 12, pp. 2130-2132, 2004.
    • (2004) Applied Physics Letters , vol.84 , Issue.12 , pp. 2130-2132
    • Kim, J.C.1    Kwon, O.Y.2    Lee, Z.H.3
  • 10
    • 24644488708 scopus 로고    scopus 로고
    • Correlation between blood compatibility and physical surface properties of titanium-based coatings
    • SPEC ISS, pp
    • I. Tsyganov, M. F. Maitz, , E. Wieser, E. Richter, and H. Reuther, "Correlation between blood compatibility and physical surface properties of titanium-based coatings" Surface and Coatings Technology, vol. 200, no. 1-4 SPEC ISS, pp. 1041-1044, 2005.
    • (2005) Surface and Coatings Technology , vol.200 , Issue.1-4 , pp. 1041-1044
    • Tsyganov, I.1    Maitz, M.F.2    Wieser, E.3    Richter, E.4    Reuther, H.5
  • 12
    • 3042585175 scopus 로고    scopus 로고
    • Material design and shape memory properties of smart composites composed of polymer and ferromagnetic shape memory alloy particles
    • H. Hosoda, S. Takeuchi, , T. Inamura, and K. Wakashima, "Material design and shape memory properties of smart composites composed of polymer and ferromagnetic shape memory alloy particles" Science and Technology of Advanced Materials, vol. 5, no. 4, pp. 503-509, 2004.
    • (2004) Science and Technology of Advanced Materials , vol.5 , Issue.4 , pp. 503-509
    • Hosoda, H.1    Takeuchi, S.2    Inamura, T.3    Wakashima, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.