메뉴 건너뛰기




Volumn 20, Issue 1, 1997, Pages 60-64

Determinants of nonthoracotomy biphasic defibrillation

Author keywords

body surface area; defibrillation threshold; implantable cardioverter defibrillator

Indexed keywords

AMIODARONE; ANTIARRHYTHMIC AGENT;

EID: 0031027548     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1997.tb04812.x     Document Type: Article
Times cited : (15)

References (8)
  • 1
    • 0025739939 scopus 로고
    • NASPE Policy Conference Committee. Implantable cardioverter‐defibrillators in cardiovascular practice: Report of the policy conference of the North American Society of Pacing and Electrophysiology
    • 1 Lehmann M, Saksena S. NASPE Policy Conference Committee. Implantable cardioverter‐defibrillators in cardiovascular practice: Report of the policy conference of the North American Society of Pacing and Electrophysiology. PACE 1991 ; 14: 969–979.
    • (1991) PACE , vol.14 , pp. 969-979
    • Lehmann, M1    Saksena, S2
  • 2
    • 0026717550 scopus 로고
    • Implantable defibrillators for prevention of sudden death
    • 2 Saksena S, Camm AJ. Implantable defibrillators for prevention of sudden death. Circulation 1992 ; 85: 2316–2321.
    • (1992) Circulation , vol.85 , pp. 2316-2321
    • Saksena, S1    Camm, AJ2
  • 3
    • 0028218797 scopus 로고
    • Mortality benefits and the implantable cardioverter‐defibrillator
    • 3 Sweeney MO, Ruskin JN. Mortality benefits and the implantable cardioverter‐defibrillator. Circulation 1994 ; 89: 1851–1858.
    • (1994) Circulation , vol.89 , pp. 1851-1858
    • Sweeney, MO1    Ruskin, JN2
  • 4
    • 0022380547 scopus 로고
    • The implanted defibrillator: Relationship of defibrillating lead configuration and clinical variables to defibrillation threshold
    • 4 Troup PJ, Chapman PD, Olinger GN, et al. The implanted defibrillator: Relationship of defibrillating lead configuration and clinical variables to defibrillation threshold. J Am Coll Cardiol 1985 ; 6: 1315–1321.
    • (1985) J Am Coll Cardiol , vol.6 , pp. 1315-1321
    • Troup, PJ1    Chapman, PD2    Olinger, GN3
  • 5
    • 0025863246 scopus 로고
    • Patients with a high defibrillation threshold: Clinical characteristics, management, and outcome
    • 5 Pinski SL, Vanerio G, Castle LW, et al. Patients with a high defibrillation threshold: Clinical characteristics, management, and outcome. Am Heart J 1991 ; 122: 89–95.
    • (1991) Am Heart J , vol.122 , pp. 89-95
    • Pinski, SL1    Vanerio, G2    Castle, LW3
  • 6
    • 0027176206 scopus 로고
    • Predictors of defibrillation efficacy in patients undergoing epicardial defibrillator implantation
    • 6 Leitch JW, Yee R. Predictors of defibrillation efficacy in patients undergoing epicardial defibrillator implantation. J Am Coll Cardiol 1993 ; 21: 132–137.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 132-137
    • Leitch, JW1    Yee, R2
  • 7
    • 0023187622 scopus 로고
    • Relationship of left ventricular mass to defibrillation for the implantable defibrillator: A combined clinical and animal study
    • 7 Chapman PD, Sagar KB, Wetherbee JN, et al. Relationship of left ventricular mass to defibrillation for the implantable defibrillator: A combined clinical and animal study. Am Heart J 1987 ; 114 274–278.
    • (1987) Am Heart J , vol.114 , pp. 274-278
    • Chapman, PD1    Sagar, KB2    Wetherbee, JN3
  • 8
    • 0027442215 scopus 로고
    • Determinants of successful nonthoracotomy cardioverter‐defibrillator implantation: Experience in 101 patients using two different lead systems
    • 8 Brooks R, Garan H, Torchiana D, et al. Determinants of successful nonthoracotomy cardioverter‐defibrillator implantation: Experience in 101 patients using two different lead systems. J Am Coll Cardiol 1993 ; 22: 1835–1842.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1835-1842
    • Brooks, R1    Garan, H2    Torchiana, D3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.