메뉴 건너뛰기




Volumn 194, Issue 3, 2010, Pages 634-641

Liver MRI at 3 T using a respiratory-triggered time-efficient 3D T2-weighted technique: Impact on artifacts and image quality

Author keywords

3 T MRI; Image quality; Liver MRI; Motion artifact; Sampling perfection with application optimized contrasts using different flip angle evolutions (SPACE); Turbo spin echo imaging

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; FEMALE; GALLBLADDER; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; KIDNEY; LIVER INJURY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; SIGNAL NOISE RATIO; SPLEEN;

EID: 77749277542     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.09.2994     Document Type: Article
Times cited : (35)

References (27)
  • 3
    • 53149117903 scopus 로고    scopus 로고
    • Abdominal applications of 3.0-T MR imaging: Comparative review versus a 1.5-T system
    • Choi JY, Kim MJ, Chung YE, et al. Abdominal applications of 3.0-T MR imaging: comparative review versus a 1.5-T system. RadioGraphics 2008; 28:e30
    • (2008) RadioGraphics , vol.28
    • Choi, J.Y.1    Kim, M.J.2    Chung, Y.E.3
  • 5
    • 33745503397 scopus 로고    scopus 로고
    • Abdominal MRI at 3.0 T: The basics revisited
    • Merkle EM, Dale BM. Abdominal MRI at 3.0 T: the basics revisited. AJR 2006; 186:1524-1532
    • (2006) AJR , vol.186 , pp. 1524-1532
    • Merkle, E.M.1    Dale, B.M.2
  • 6
    • 71849117321 scopus 로고    scopus 로고
    • Quantitative and qualitative comparison of 3.0T and 1.5T MR imaging of the liver in patients with diffuse parenchymal liver disease
    • Tsurusaki M, Semelka RC, Zapparoli M, et al. Quantitative and qualitative comparison of 3.0T and 1.5T MR imaging of the liver in patients with diffuse parenchymal liver disease. Eur J Radiol 2009; 72:314-320
    • (2009) Eur J Radiol , vol.72 , pp. 314-320
    • Tsurusaki, M.1    Semelka, R.C.2    Zapparoli, M.3
  • 7
    • 44649187785 scopus 로고    scopus 로고
    • 3.0-T MRI evaluation of patients with chronic liver diseases: Initial observations
    • Zapparoli M, Semelka RC, Altun E, et al. 3.0-T MRI evaluation of patients with chronic liver diseases: initial observations. Magn Reson Imaging 2008; 26:650-660
    • (2008) Magn Reson Imaging , vol.26 , pp. 650-660
    • Zapparoli, M.1    Semelka, R.C.2    Altun, E.3
  • 8
    • 33646360840 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the pancreas at 3.0 Tesla: Qualitative and quantitative comparison with 1.5 Tesla
    • Edelman RR, Salanitri G, Brand R, et al. Magnetic resonance imaging of the pancreas at 3.0 Tesla: qualitative and quantitative comparison with 1.5 Tesla. Invest Radiol 2006; 41:175-180
    • (2006) Invest Radiol , vol.41 , pp. 175-180
    • Edelman, R.R.1    Salanitri, G.2    Brand, R.3
  • 9
    • 28044467524 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbospin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: Initial clinical experiences
    • Lichy MP, Wietek BM, Mugler JP 3rd, et al. Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbospin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences. Invest Radiol 2005; 40:754-760
    • (2005) Invest Radiol , vol.40 , pp. 754-760
    • Lichy, M.P.1    Wietek, B.M.2    Mugler 3rd, J.P.3
  • 10
    • 2342574259 scopus 로고    scopus 로고
    • Reduced RF power without blurring: Correcting for modulation of refocusing flip angle in FSE sequences
    • Busse RF. Reduced RF power without blurring: correcting for modulation of refocusing flip angle in FSE sequences. Magn Reson Med 2004; 51:1031-1037
    • (2004) Magn Reson Med , vol.51 , pp. 1031-1037
    • Busse, R.F.1
  • 11
    • 33646449765 scopus 로고    scopus 로고
    • Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast
    • Busse RF, Hariharan H, Vu A, Brittain JH. Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast. Magn Reson Med 2006; 55:1030-1037
    • (2006) Magn Reson Med , vol.55 , pp. 1030-1037
    • Busse, R.F.1    Hariharan, H.2    Vu, A.3    Brittain, J.H.4
  • 12
    • 51449085600 scopus 로고    scopus 로고
    • Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo
    • Busse RF, Brau AC, Vu A, et al. Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo. Magn Reson Med 2008; 60:640-649
    • (2008) Magn Reson Med , vol.60 , pp. 640-649
    • Busse, R.F.1    Brau, A.C.2    Vu, A.3
  • 13
    • 0033841963 scopus 로고    scopus 로고
    • Optimized single-slab three-dimensional spin-echo MR imaging of the brain
    • Mugler JP 3rd, Bao S, Mulkern RV, et al. Optimized single-slab three-dimensional spin-echo MR imaging of the brain. Radiology 2000; 216:891-899
    • (2000) Radiology , vol.216 , pp. 891-899
    • Mugler 3rd, J.P.1    Bao, S.2    Mulkern, R.V.3
  • 14
    • 39549115232 scopus 로고    scopus 로고
    • N/2 ghosting artifacts: Elimination at 3.0-T MR cholangiography with SPACE pulse sequence
    • Haystead CM, Dale BM, Merkle EM. N/2 ghosting artifacts: elimination at 3.0-T MR cholangiography with SPACE pulse sequence. Radiology 2008; 246:589-595
    • (2008) Radiology , vol.246 , pp. 589-595
    • Haystead, C.M.1    Dale, B.M.2    Merkle, E.M.3
  • 15
    • 76149138085 scopus 로고    scopus 로고
    • High spatial resolution 3D MR cholangiography with high sampling efficiency technique (SPACE): Comparison of 3T vs. 1.5T
    • Sep 30 [Epub ahead of print
    • Arizono S, Isoda H, Maetani YS, et al. High spatial resolution 3D MR cholangiography with high sampling efficiency technique (SPACE): comparison of 3T vs. 1.5T. Eur J Radiol 2008 Sep 30 [Epub ahead of print]
    • (2008) Eur J Radiol
    • Arizono, S.1    Isoda, H.2    Maetani, Y.S.3
  • 16
    • 51449096625 scopus 로고    scopus 로고
    • Highspatial-resolution three-dimensional MR cholangiography using a high-sampling-efficiency technique (SPACE) at 3T: Comparison with the conventional constant flip angle sequence in healthy volunteers
    • Arizono S, Isoda H, Maetani YS, et al. Highspatial-resolution three-dimensional MR cholangiography using a high-sampling-efficiency technique (SPACE) at 3T: comparison with the conventional constant flip angle sequence in healthy volunteers. J Magn Reson Imaging 2008; 28:685-690
    • (2008) J Magn Reson Imaging , vol.28 , pp. 685-690
    • Arizono, S.1    Isoda, H.2    Maetani, Y.S.3
  • 17
    • 77749254517 scopus 로고    scopus 로고
    • International Electrotechnical Commission. Particular requirements for the safety of magnetic resonance equipment for medical diagnosis. London, UK: International Electrotechnical Commission, 2002: publication no. IEC 60601-2-33
    • International Electrotechnical Commission. Particular requirements for the safety of magnetic resonance equipment for medical diagnosis. London, UK: International Electrotechnical Commission, 2002: publication no. IEC 60601-2-33
  • 18
    • 44449139521 scopus 로고    scopus 로고
    • Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion
    • Franklin KM, Dale BM, Merkle EM. Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion. J Magn Reson Imaging 2008; 27:1443-1447
    • (2008) J Magn Reson Imaging , vol.27 , pp. 1443-1447
    • Franklin, K.M.1    Dale, B.M.2    Merkle, E.M.3
  • 19
    • 37349125546 scopus 로고    scopus 로고
    • MR imaging of the female pelvis at 3 Tesla: Evaluation of image homogeneity using different dielectric pads
    • Kataoka M, Isoda H, Maetani Y, et al. MR imaging of the female pelvis at 3 Tesla: evaluation of image homogeneity using different dielectric pads. J Magn Reson Imaging 2007; 26:1572-1577
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1572-1577
    • Kataoka, M.1    Isoda, H.2    Maetani, Y.3
  • 20
    • 12844272274 scopus 로고    scopus 로고
    • Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T
    • Saekho S, Boada FE, Noll DC, Stenger VA. Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T. Magn Reson Med 2005; 53:479-484
    • (2005) Magn Reson Med , vol.53 , pp. 479-484
    • Saekho, S.1    Boada, F.E.2    Noll, D.C.3    Stenger, V.A.4
  • 21
    • 33750630873 scopus 로고    scopus 로고
    • Parallel RF transmission with eight channels at 3 Tesla
    • Setsompop K, Wald LL, Alagappan V, et al. Parallel RF transmission with eight channels at 3 Tesla. Magn Reson Med 2006; 56:1163-1171
    • (2006) Magn Reson Med , vol.56 , pp. 1163-1171
    • Setsompop, K.1    Wald, L.L.2    Alagappan, V.3
  • 22
    • 70349611298 scopus 로고    scopus 로고
    • Reduction of B1 sensitivity in selective single-slab 3D turbo spin-echo imaging with very long echo trains
    • Park J, Mugler JP, Hughes T. Reduction of B1 sensitivity in selective single-slab 3D turbo spin-echo imaging with very long echo trains. Magn Reson Med 2009; 62:1060-1066
    • (2009) Magn Reson Med , vol.62 , pp. 1060-1066
    • Park, J.1    Mugler, J.P.2    Hughes, T.3
  • 23
    • 27644527486 scopus 로고    scopus 로고
    • Image reconstruction in SNR units: A general method for SNR measurement
    • Kellman P, McVeigh ER. Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med 2005; 54:1439-1447
    • (2005) Magn Reson Med , vol.54 , pp. 1439-1447
    • Kellman, P.1    McVeigh, E.R.2
  • 24
    • 34547879249 scopus 로고    scopus 로고
    • Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    • Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 2007; 26:375-385
    • (2007) J Magn Reson Imaging , vol.26 , pp. 375-385
    • Dietrich, O.1    Raya, J.G.2    Reeder, S.B.3    Reiser, M.F.4    Schoenberg, S.O.5
  • 25
    • 36248932721 scopus 로고    scopus 로고
    • Noise measurement and estimation in MR imaging experiments
    • Heverhagen JT. Noise measurement and estimation in MR imaging experiments. Radiology 2007; 245:638-639
    • (2007) Radiology , vol.245 , pp. 638-639
    • Heverhagen, J.T.1
  • 26
    • 46849105029 scopus 로고    scopus 로고
    • Pelvic imaging using a T1W fat-suppressed three-dimensional dual echo Dixon technique at 3T
    • Cornfeld DM, Israel G, McCarthy SM, Weinreb JC. Pelvic imaging using a T1W fat-suppressed three-dimensional dual echo Dixon technique at 3T. J Magn Reson Imaging 2008; 28:121-127
    • (2008) J Magn Reson Imaging , vol.28 , pp. 121-127
    • Cornfeld, D.M.1    Israel, G.2    McCarthy, S.M.3    Weinreb, J.C.4
  • 27
    • 63449095958 scopus 로고    scopus 로고
    • Effect of superparamagnetic iron oxide on tumor-to-liver contrast at T2*-weighted gradient-echo MRI: Comparison between 3.0T and 1.5T MR systems
    • Kim T, Murakami T, Hori M, Onishi H, Tomoda K, Nakamura H. Effect of superparamagnetic iron oxide on tumor-to-liver contrast at T2*-weighted gradient-echo MRI: comparison between 3.0T and 1.5T MR systems. J Magn Reson Imaging 2009; 29:595-600
    • (2009) J Magn Reson Imaging , vol.29 , pp. 595-600
    • Kim, T.1    Murakami, T.2    Hori, M.3    Onishi, H.4    Tomoda, K.5    Nakamura, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.