메뉴 건너뛰기




Volumn 28, Issue 1, 2008, Pages 121-127

Pelvic imaging using a T1W fat-suppressed three-dimensional dual echo dixon technique at 3T

Author keywords

Dixon; Fat suppression; MRI; Pelvis

Indexed keywords

ADIPOSE TISSUE; ARTICLE; ARTIFACT; CLINICAL ARTICLE; FEMALE; HUMAN; IMAGE ANALYSIS; MUSCLE TISSUE; MYOMETRIUM; NUCLEAR MAGNETIC RESONANCE IMAGING; PELVIS; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SOFT TISSUE; THREE DIMENSIONAL IMAGING;

EID: 46849105029     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21402     Document Type: Article
Times cited : (48)

References (19)
  • 1
    • 0032882776 scopus 로고    scopus 로고
    • Abdominal MR imaging with a volumetric interpolated breath-hold examination
    • Rofsky NM, Lee VS, Laub G, et al. Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology 1999;212:876-884.
    • (1999) Radiology , vol.212 , pp. 876-884
    • Rofsky, N.M.1    Lee, V.S.2    Laub, G.3
  • 2
    • 0032238529 scopus 로고    scopus 로고
    • MRI of the uterus, uterine cervix, and vagina: Diagnostic performance of dynamic contrast-enhanced fast multiplanar fast multiplanar gradient-echo imaging in comparison with fast spin-echo T2-weighted pulse imaging
    • Liu PF, Krestin GP, Huch RA, Gohde SC, Caduff RF, Debatin JF. MRI of the uterus, uterine cervix, and vagina: diagnostic performance of dynamic contrast-enhanced fast multiplanar fast multiplanar gradient-echo imaging in comparison with fast spin-echo T2-weighted pulse imaging. Eur Radiol 1998;8:1433-1440.
    • (1998) Eur Radiol , vol.8 , pp. 1433-1440
    • Liu, P.F.1    Krestin, G.P.2    Huch, R.A.3    Gohde, S.C.4    Caduff, R.F.5    Debatin, J.F.6
  • 3
    • 33749646854 scopus 로고    scopus 로고
    • MRI of the kidney and urinary tract
    • Israel GM. MRI of the kidney and urinary tract. J Magn Reson Imaging 2006;24:725-734.
    • (2006) J Magn Reson Imaging , vol.24 , pp. 725-734
    • Israel, G.M.1
  • 5
    • 0028351561 scopus 로고
    • Inversion in the steady state: Contrast optimization and reduced imaging time with fast three-dimensional inversion-recovert-prepared GRE pulse sequences
    • Foo TKF, Sawyer A, Faulkner W, Mills DG. Inversion in the steady state: contrast optimization and reduced imaging time with fast three-dimensional inversion-recovert-prepared GRE pulse sequences. Radiology 1994;191:85-90.
    • (1994) Radiology , vol.191 , pp. 85-90
    • Foo, T.K.F.1    Sawyer, A.2    Faulkner, W.3    Mills, D.G.4
  • 6
    • 33748450065 scopus 로고    scopus 로고
    • In-vivo mapping of B1 uniformity produced by a whole body 3T RF coil
    • Alsop D, Watkins RD. Greenman R, et al. In-vivo mapping of B1 uniformity produced by a whole body 3T RF coil. In: Proc ISMRM 2001;9:1094.
    • (2001) Proc ISMRM , vol.9 , pp. 1094
    • Alsop, D.1    Watkins, R.D.2    Greenman, R.3
  • 7
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • Dixon WT. Simple proton spectroscopic imaging. Radiology 1984;153:189-194.
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.T.1
  • 8
    • 0025831477 scopus 로고
    • Three point Dixon technique for true water/fat decomposition with BO inhomogeniety correction
    • Glover GH, Schneider E. Three point Dixon technique for true water/fat decomposition with BO inhomogeniety correction. Magn Reson Med 1991;18:371-383.
    • (1991) Magn Reson Med , vol.18 , pp. 371-383
    • Glover, G.H.1    Schneider, E.2
  • 9
    • 0026216918 scopus 로고
    • Multipoint Dixon technique for water and fat proton and susceptibility imaging
    • Glover GH. Multipoint Dixon technique for water and fat proton and susceptibility imaging. J Magn Reson Imaging 1991;1:521-530.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 521-530
    • Glover, G.H.1
  • 10
    • 33747408081 scopus 로고    scopus 로고
    • Fat signal suppression in head and neck imaging using fast spin-echo IDEAL technique
    • Barger AV, DeLone DR, Bernstein MA, Welker KM. Fat signal suppression in head and neck imaging using fast spin-echo IDEAL technique. AJNR Am J Neuroradiol 2006;27:1292-1294.
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 1292-1294
    • Barger, A.V.1    DeLone, D.R.2    Bernstein, M.A.3    Welker, K.M.4
  • 11
    • 21244446679 scopus 로고    scopus 로고
    • Cardiac CINE imaging with IDEAL water fat suppression and steady state free precession
    • Reeder SB, Mark LM, Yu H, et al. Cardiac CINE imaging with IDEAL water fat suppression and steady state free precession. J Magn Reson Imaging 2005;22:44-52.
    • (2005) J Magn Reson Imaging , vol.22 , pp. 44-52
    • Reeder, S.B.1    Mark, L.M.2    Yu, H.3
  • 12
    • 9644291523 scopus 로고    scopus 로고
    • T2 weighted spine imaging with a fast three-point Dixon technique: Comparison with chemical shift selective fat suppression
    • Ma J, Kingh AK, Kumar AJ, et al. T2 weighted spine imaging with a fast three-point Dixon technique: comparison with chemical shift selective fat suppression. J Magn Reson Imaging 2004;20:1025-1029.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 1025-1029
    • Ma, J.1    Kingh, A.K.2    Kumar, A.J.3
  • 13
    • 33749594255 scopus 로고    scopus 로고
    • T1- and T2-weighted fast spin-echo imaging of the brachial plexus and cervical spine with IDEAL water-fat separation
    • Reeder SB, Yu H, Jognson JW, et al. T1- and T2-weighted fast spin-echo imaging of the brachial plexus and cervical spine with IDEAL water-fat separation. J Magn Reson Imaging 2006;24:825-832.
    • (2006) J Magn Reson Imaging , vol.24 , pp. 825-832
    • Reeder, S.B.1    Yu, H.2    Jognson, J.W.3
  • 14
    • 0034773525 scopus 로고    scopus 로고
    • Fast three-point Dixon MR imaging using low-resolution images for phase correction: A comparison with chemical shift selective fat suppression for pediatriac musculoskeletal imaging
    • Rybicki FJ, Chung T, Reid T, Jaramillo D, Mulkern RV, Ma J. Fast three-point Dixon MR imaging using low-resolution images for phase correction: a comparison with chemical shift selective fat suppression for pediatriac musculoskeletal imaging. AJR Am J Roentgenol 2001;177:1019-1023.
    • (2001) AJR Am J Roentgenol , vol.177 , pp. 1019-1023
    • Rybicki, F.J.1    Chung, T.2    Reid, T.3    Jaramillo, D.4    Mulkern, R.V.5    Ma, J.6
  • 15
    • 33746263952 scopus 로고    scopus 로고
    • Cartilage of the knee: Rapid three-dimensional MR imaging at 3.0 T with IDEAL balanced steady-state free precession - initial experience
    • Gold GE, Reeder SB, Yu H, et al. Cartilage of the knee: rapid three-dimensional MR imaging at 3.0 T with IDEAL balanced steady-state free precession - initial experience. Radiology 2006;240:546-551.
    • (2006) Radiology , vol.240 , pp. 546-551
    • Gold, G.E.1    Reeder, S.B.2    Yu, H.3
  • 16
    • 33751258007 scopus 로고    scopus 로고
    • Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) fast spin-echo imaging of the ankle: Initial clinical experience
    • Fuller S, Reeder S, Shimakawa A, et al. Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) fast spin-echo imaging of the ankle: initial clinical experience. AJR Am J Roentgenol 2006;187:1442-1447.
    • (2006) AJR Am J Roentgenol , vol.187 , pp. 1442-1447
    • Fuller, S.1    Reeder, S.2    Shimakawa, A.3
  • 17
    • 30744448686 scopus 로고    scopus 로고
    • Fat-suppressed three-dimensional dual echo Dixon technique for contrast agent enhanced MRI
    • Ma J, Vu AT, Son JB, Choi H, Hazle JD. Fat-suppressed three-dimensional dual echo Dixon technique for contrast agent enhanced MRI. J Magn Reson Imaging 2006;23:36-41.
    • (2006) J Magn Reson Imaging , vol.23 , pp. 36-41
    • Ma, J.1    Vu, A.T.2    Son, J.B.3    Choi, H.4    Hazle, J.D.5
  • 18
    • 3543083453 scopus 로고    scopus 로고
    • Breath-hold water and fat imaging using a dual-echo two point Dixon technique with an efficient and robust phase-correction algorithm
    • Ma J. Breath-hold water and fat imaging using a dual-echo two point Dixon technique with an efficient and robust phase-correction algorithm. Magn Reson Med 2004;52:415-419.
    • (2004) Magn Reson Med , vol.52 , pp. 415-419
    • Ma, J.1
  • 19
    • 34547736137 scopus 로고    scopus 로고
    • Fast spin-echo triple-echo Dixon (fTED) technique for efficient T2-weighted water and fat imaging
    • Ma J, Son J, Zhou Y, Le-Petross H, Choi H. Fast spin-echo triple-echo Dixon (fTED) technique for efficient T2-weighted water and fat imaging. Magn Reson Med 2007;58:103-109.
    • (2007) Magn Reson Med , vol.58 , pp. 103-109
    • Ma, J.1    Son, J.2    Zhou, Y.3    Le-Petross, H.4    Choi, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.