메뉴 건너뛰기




Volumn 246, Issue 2, 2008, Pages 589-595

N/2 ghosting artifacts: Elimination at 3.0-T MR cholangiography with SPACE pulse sequence

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT; BILE DUCT; BILE FLOW; CHOLANGIOGRAPHY; CLINICAL ARTICLE; COMMON BILE DUCT STONE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; HUMAN; IMAGE QUALITY; INFORMED CONSENT; LIVER SURGERY; MALE; MEDICAL RECORD REVIEW; NUCLEAR MAGNETIC RESONANCE; PANCREATITIS; PATIENT REFERRAL; PRIORITY JOURNAL; RADIODIAGNOSIS; ALGORITHM; BILIARY TRACT DISEASE; COMPUTER ASSISTED DIAGNOSIS; IMAGE ENHANCEMENT; MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY; METHODOLOGY; MIDDLE AGED; PATHOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; SIGNAL PROCESSING;

EID: 39549115232     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.2462061674     Document Type: Article
Times cited : (38)

References (17)
  • 1
  • 2
    • 27744515684 scopus 로고    scopus 로고
    • A comparison of MR cholangiopancreatography at 1.5 and 3.0 Tesla
    • O'Regan DP, Fitzgerald J, Allsop J, et al. A comparison of MR cholangiopancreatography at 1.5 and 3.0 Tesla. Br J Radiol 2005;78:894-898.
    • (2005) Br J Radiol , vol.78 , pp. 894-898
    • O'Regan, D.P.1    Fitzgerald, J.2    Allsop, J.3
  • 5
    • 28044467524 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: Initial clinical experiences
    • Lichy MP, Wietek BM, Mugler JP 3rd, et al. Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences. Invest Radiol 2005;40:754-760.
    • (2005) Invest Radiol , vol.40 , pp. 754-760
    • Lichy, M.P.1    Wietek, B.M.2    Mugler 3rd, J.P.3
  • 6
    • 27944503488 scopus 로고    scopus 로고
    • Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction
    • Asbach P, Klessen C, Kroencke TJ, et al. Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction. Magn Reson Imaging 2005;23:939-945.
    • (2005) Magn Reson Imaging , vol.23 , pp. 939-945
    • Asbach, P.1    Klessen, C.2    Kroencke, T.J.3
  • 7
    • 17844396526 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction
    • Klessen C, Asbach P, Kroencke TJ, et al. Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction. J Magn Reson Imaging 2005;21:576-582.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 576-582
    • Klessen, C.1    Asbach, P.2    Kroencke, T.J.3
  • 8
    • 0035354209 scopus 로고    scopus 로고
    • Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multi-echo reference scan
    • Schmithorst VJ, Dardzinski BJ, Holland SK. Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multi-echo reference scan. IEEE Trans Med Imaging 2001;20:535-539.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 535-539
    • Schmithorst, V.J.1    Dardzinski, B.J.2    Holland, S.K.3
  • 13
    • 22844444193 scopus 로고    scopus 로고
    • Whole-body MRI at high field: Technical limits and clinical potential
    • Schick F. Whole-body MRI at high field: technical limits and clinical potential. Eur Radiol 2005;15:946-959.
    • (2005) Eur Radiol , vol.15 , pp. 946-959
    • Schick, F.1
  • 14
    • 0032726055 scopus 로고    scopus 로고
    • Dielectric resonance phenomena in ultra high field MRI
    • Kangarlu A, Baertlein BA, Lee R, et al. Dielectric resonance phenomena in ultra high field MRI. J Comput Assist Tomogr 1999;23:821-831.
    • (1999) J Comput Assist Tomogr , vol.23 , pp. 821-831
    • Kangarlu, A.1    Baertlein, B.A.2    Lee, R.3
  • 15
    • 12744262814 scopus 로고    scopus 로고
    • Central brightening due to constructive interference with, without, and despite dielectric resonance
    • Collins CM, Liu W, Schreiber W, Yang QX, Smith MB. Central brightening due to constructive interference with, without, and despite dielectric resonance. J Magn Reson Imaging 2005;21:192-196.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 192-196
    • Collins, C.M.1    Liu, W.2    Schreiber, W.3    Yang, Q.X.4    Smith, M.B.5
  • 16
    • 0030186598 scopus 로고    scopus 로고
    • Oral magnetic particles (ferristene) as a contrast medium in abdominal magnetic resonance imaging
    • Jacobsen TF, Van Beers LM, Dupas B et al. Oral magnetic particles (ferristene) as a contrast medium in abdominal magnetic resonance imaging. Acad Radiol 1996;3:571-580.
    • (1996) Acad Radiol , vol.3 , pp. 571-580
    • Jacobsen, T.F.1    Van Beers, L.M.2    Dupas, B.3
  • 17
    • 0036259855 scopus 로고    scopus 로고
    • Disappearance of the common bile duct signal caused by oral negative contrast agent on MR cholangiopancreatography
    • Sugita R, Nomiya T. Disappearance of the common bile duct signal caused by oral negative contrast agent on MR cholangiopancreatography. J Comput Assist Tomogr 2002;26:448-450.
    • (2002) J Comput Assist Tomogr , vol.26 , pp. 448-450
    • Sugita, R.1    Nomiya, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.