메뉴 건너뛰기




Volumn 16, Issue 2, 2007, Pages 239-244

Assessment of CAOS as a training model in spinal surgery: A randomised study

Author keywords

Computer assisted orthopaedic surgery; Conventional fluoroscopic technique; Pedicle screw insertion; Porcine cadaver lumbar spine study; Training model

Indexed keywords

ANIMAL TISSUE; ARTICLE; CADAVER; COMPARATIVE STUDY; COMPUTER ASSISTED SURGERY; CONTROLLED STUDY; DISSECTION; HUMAN; IMAGING; LOGISTIC REGRESSION ANALYSIS; LUMBAR SPINE; MEDICAL EDUCATION; NONHUMAN; NORMAL HUMAN; ORTHOPEDIC SURGERY; PEDICLE SCREW; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZATION; RELIABILITY; SPINE SURGERY; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; SURGEON;

EID: 33847109374     PISSN: 09406719     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00586-006-0109-9     Document Type: Article
Times cited : (16)

References (21)
  • 2
    • 0034061781 scopus 로고    scopus 로고
    • Comparative Results Between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    • Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative Results Between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25(5):606-614
    • (2000) Spine , vol.25 , Issue.5 , pp. 606-614
    • Amiot, L.P.1    Lang, K.2    Putzier, M.3    Zippel, H.4    Labelle, H.5
  • 5
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11-14
    • (1990) Spine , vol.15 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 7
    • 33847134992 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement: A prospective randomised laboratory study using porcine cervical spines
    • Br
    • Kurta I, Dove M, Richards P, Rahmatalla A, MacKenzie, Dove J (2002) Accuracy of pedicle screw placement: a prospective randomised laboratory study using porcine cervical spines. J Bone Joint Surg [Br] 84-B:96
    • (2002) J Bone Joint Surg , vol.84-B , pp. 96
    • Kurta, I.1    Dove, M.2    Richards, P.3    Rahmatalla, A.4
  • 8
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235-240
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3    Lohikoski, J.4    Schlenzka, D.5
  • 9
    • 0030926450 scopus 로고    scopus 로고
    • Improved accuracy of pedicle screw insertion with computer assisted surgery - a prospective clinical trial of 30 patients
    • Laine T, Schlenzka D, Maekitalo K, tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer assisted surgery - a prospective clinical trial of 30 patients. Spine 22(11):1254-1258
    • (1997) Spine , vol.22 , Issue.11 , pp. 1254-1258
    • Laine, T.1    Schlenzka, D.2    Maekitalo, K.3    tallroth, K.4    Nolte, L.P.5    Visarius, H.6
  • 15
    • 0035865653 scopus 로고    scopus 로고
    • Accuracy requirements for image-guided spinal pedicle screw placement
    • Rampersaud YR, Simon D, Foley K (2001) Accuracy requirements for image-guided spinal pedicle screw placement. Spine 6(4):352-359
    • (2001) Spine , vol.6 , Issue.4 , pp. 352-359
    • Rampersaud, Y.R.1    Simon, D.2    Foley, K.3
  • 16
  • 17
    • 0032532465 scopus 로고    scopus 로고
    • Clinical relevance of accuracy of pedicle screw placement - a computed tomographic-supported analysis
    • Schulze CJ, Munzinger E, Weber U (1998) Clinical relevance of accuracy of pedicle screw placement - a computed tomographic-supported analysis. Spine 23(20):2215-2221
    • (1998) Spine , vol.23 , Issue.20 , pp. 2215-2221
    • Schulze, C.J.1    Munzinger, E.2    Weber, U.3
  • 19
    • 0033508657 scopus 로고    scopus 로고
    • The porcine cervical spine as a model of the human lumbar spine: An anatomical, geometric and functional comparison
    • Yingling VR, Callaghan JP, McGill SM (1999) The porcine cervical spine as a model of the human lumbar spine: an anatomical, geometric and functional comparison. J Spinal Disord 12(5):415-423
    • (1999) J Spinal Disord , vol.12 , Issue.5 , pp. 415-423
    • Yingling, V.R.1    Callaghan, J.P.2    McGill, S.M.3
  • 20
    • 0031431918 scopus 로고    scopus 로고
    • Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine
    • Yoo JU, Ghanayem A, Petersilge C et al (1997) Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine. Spine 22(22):2668-2671
    • (1997) Spine , vol.22 , Issue.22 , pp. 2668-2671
    • Yoo, J.U.1    Ghanayem, A.2    Petersilge, C.3
  • 21
    • 0022628372 scopus 로고    scopus 로고
    • A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine
    • Zindrick MR, Wiltse LL, Widell EH et al (1998) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res 203:99-112
    • (1998) Clin Orthop Relat Res , vol.203 , pp. 99-112
    • Zindrick, M.R.1    Wiltse, L.L.2    Widell, E.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.