메뉴 건너뛰기




Volumn 34, Issue 2, 2010, Pages 105-112

Hydrodynamics of aortic cannulae during extracorporeal circulation in a mock aortic arch aneurysm model

Author keywords

Aortic arch aneurysm; Aortic cannula; Cardiopulmonary bypass; Extracorporeal circulation; Hydrodynamics; Particle image velocimetry

Indexed keywords

BLOOD VESSELS; DISPERSIONS; FIGHTER AIRCRAFT; FLOW PATTERNS; TENSORS; VELOCITY MEASUREMENT; VORTEX FLOW;

EID: 77149123335     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2009.00764.x     Document Type: Article
Times cited : (15)

References (25)
  • 1
    • 0029127309 scopus 로고
    • Risk factors for stroke following coronary bypass surgery
    • Rao V, Christakis GT, Weisel RD, et al. Risk factors for stroke following coronary bypass surgery. J Card Surg 1995 10 : 468 74.
    • (1995) J Card Surg , vol.10 , pp. 468-474
    • Rao, V.1    Christakis, G.T.2    Weisel, R.D.3
  • 2
    • 0030465092 scopus 로고    scopus 로고
    • Flow patterns in dog aortic arch under a steady flow condition simulating mid-systole
    • Endo S, Sohara Y, Karino T. Flow patterns in dog aortic arch under a steady flow condition simulating mid-systole. Heart Vessels 1996 11 : 180 91.
    • (1996) Heart Vessels , vol.11 , pp. 180-191
    • Endo, S.1    Sohara, Y.2    Karino, T.3
  • 3
    • 0020429467 scopus 로고
    • Physiological pulsatile flow experiments in a model of the human aortic arch
    • Yeawood TL, Chandran KB. Physiological pulsatile flow experiments in a model of the human aortic arch. J Biomech 1984 15 : 683 704.
    • (1984) J Biomech , vol.15 , pp. 683-704
    • Yeawood, T.L.1    Chandran, K.B.2
  • 4
    • 0036594329 scopus 로고    scopus 로고
    • Computational fluid dynamics modeling and analysis of the effect of 3-D distortion of the human aortic arch
    • Mori D, Yamaguchi T. Computational fluid dynamics modeling and analysis of the effect of 3-D distortion of the human aortic arch. Comput Methods Biomech Biomed Engin 2002 5 : 249 60.
    • (2002) Comput Methods Biomech Biomed Engin , vol.5 , pp. 249-260
    • Mori, D.1    Yamaguchi, T.2
  • 6
    • 0027484408 scopus 로고
    • Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping
    • Kilner PJ, Yang GZ, Mohiaddin RH, Firmin DN, Longmore DB. Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping. Circulation 1993 88 : 2235 47.
    • (1993) Circulation , vol.88 , pp. 2235-2247
    • Kilner, P.J.1    Yang, G.Z.2    Mohiaddin, R.H.3    Firmin, D.N.4    Longmore, D.B.5
  • 7
    • 0038650974 scopus 로고    scopus 로고
    • Echocardiografic comparison of the standard end-hole cannula, the soft-flow cannula, and the dispersion cannula during perfusion into the aortic arch
    • Grooters RK, Ver Steeg DA, Stewart MJ, Thieman KC, Schneider RF. Echocardiografic comparison of the standard end-hole cannula, the soft-flow cannula, and the dispersion cannula during perfusion into the aortic arch. Ann Thorac Surg 2003 75 : 1919 23.
    • (2003) Ann Thorac Surg , vol.75 , pp. 1919-1923
    • Grooters, R.K.1    Ver Steeg, D.A.2    Stewart, M.J.3    Thieman, K.C.4    Schneider, R.F.5
  • 9
    • 0029050814 scopus 로고
    • Aortic cannula velocimetry
    • Groom RC, Hill AG, Kuban B, et al. Aortic cannula velocimetry. Perfusion 1995 10 : 183 8.
    • (1995) Perfusion , vol.10 , pp. 183-188
    • Groom, R.C.1    Hill, A.G.2    Kuban, B.3
  • 10
    • 36448964491 scopus 로고    scopus 로고
    • Effect of cannula shape on aortic wall and flow turbulence: Hydrodynamic study during extracorporeal circulation in mock thoracic aorta
    • Minakawa M, Fukuda I, Yamazaki J, Fukui K, Yanaoka H, Inamura T. Effect of cannula shape on aortic wall and flow turbulence: hydrodynamic study during extracorporeal circulation in mock thoracic aorta. Artif Organs 2007 31 : 880 6.
    • (2007) Artif Organs , vol.31 , pp. 880-886
    • Minakawa, M.1    Fukuda, I.2    Yamazaki, J.3    Fukui, K.4    Yanaoka, H.5    Inamura, T.6
  • 11
    • 29544438084 scopus 로고    scopus 로고
    • Visualization of blood flow in aortic arch by using PIV method (in case of cannula insertion)
    • in Japanese Y.*Watanabe M.*Hirooka Y.*Ohse Y.*Tanaka A.*Watanabe T
    • Inamura T, Yanaoka H, Yamazaki J, Fukuda I, Minakawa M, Fukui K. Visualization of blood flow in aortic arch by using PIV method (in case of cannula insertion). Trans Jpn Soc Mech Eng Ser B 2005 710 : 2385 92 in Japanese Y, Watanabe M, Hirooka Y, Ohse Y, Tanaka A, Watanabe T. Significance of atherosclerotic changes of the ascending aorta during coronary bypass surgery with intraoperative detection by echography. J Cardiovasc Surg 1991 32 : 301 6.
    • (2005) J Cardiovasc Surg , vol.710 , pp. 2385-2392
    • Inamura, T.1    Yanaoka, H.2    Yamazaki, J.3    Fukuda, I.4    Minakawa, M.5    Fukui, K.6
  • 12
    • 0032751227 scopus 로고    scopus 로고
    • Stroke in cardiac surgical patients: Determinants and outcome
    • Almassi GH, Sommers T, Moritz TE, et al. Stroke in cardiac surgical patients: determinants and outcome. Ann Thorac Surg 1999 68 : 391 8.
    • (1999) Ann Thorac Surg , vol.68 , pp. 391-398
    • Almassi, G.H.1    Sommers, T.2    Moritz, T.E.3
  • 13
    • 0030880871 scopus 로고    scopus 로고
    • Aortic atheroma is related to outcome but not numbers of emboli during coronary bypass
    • Barbut D, Lo YW, Hartman GS, et al. Aortic atheroma is related to outcome but not numbers of emboli during coronary bypass. Ann Thorac Surg 1997 64 : 454 9.
    • (1997) Ann Thorac Surg , vol.64 , pp. 454-459
    • Barbut, D.1    Lo, Y.W.2    Hartman, G.S.3
  • 14
    • 0037997986 scopus 로고    scopus 로고
    • Total arch replacement using antegrade selective cerebral perfusion with right axillary artery perfusion
    • Numata S, Ogino H, Sasaki H, et al. Total arch replacement using antegrade selective cerebral perfusion with right axillary artery perfusion. Eur J Cardiothorac Surg 2003 23 : 771 5.
    • (2003) Eur J Cardiothorac Surg , vol.23 , pp. 771-775
    • Numata, S.1    Ogino, H.2    Sasaki, H.3
  • 15
    • 33846362148 scopus 로고    scopus 로고
    • Aortic arch replacement using selective cerebral perfusion
    • Kazui T, Yamashita K, Washiyama N, et al. Aortic arch replacement using selective cerebral perfusion. Ann Thorac Surg 2007 83 : S796 8.
    • (2007) Ann Thorac Surg , vol.83
    • Kazui, T.1    Yamashita, K.2    Washiyama, N.3
  • 16
    • 0345096373 scopus 로고    scopus 로고
    • Mortality and morbidity after total arch replacement using a branched arch graft with selective antegrade cerebral perfusion
    • Ueda T, Shimizu H, Hashizume K, et al. Mortality and morbidity after total arch replacement using a branched arch graft with selective antegrade cerebral perfusion. Ann Thorac Surg 2003 76 : 1951 6.
    • (2003) Ann Thorac Surg , vol.76 , pp. 1951-1956
    • Ueda, T.1    Shimizu, H.2    Hashizume, K.3
  • 17
    • 0034934915 scopus 로고    scopus 로고
    • Prospective comparative study of brain protection in total aortic arch replacement: Deep hypothermic circulatory arrest with retrograde cerebral perfusion or selective antegrade cerebral perfusion
    • Okita Y, Minatoya K, Tagusari O, Ando M, Nagatsuka K, Kitamura S. Prospective comparative study of brain protection in total aortic arch replacement: deep hypothermic circulatory arrest with retrograde cerebral perfusion or selective antegrade cerebral perfusion. Ann Thorac Surg 2001 72 : 72 9.
    • (2001) Ann Thorac Surg , vol.72 , pp. 72-79
    • Okita, Y.1    Minatoya, K.2    Tagusari, O.3    Ando, M.4    Nagatsuka, K.5    Kitamura, S.6
  • 18
  • 19
    • 10744223239 scopus 로고    scopus 로고
    • Propensity case-matched analysis of off-pump coronary artery bypass grafting in patients with atheromatous aortic disease
    • Sharony R, Grossi EA, Saunders PC, et al. Propensity case-matched analysis of off-pump coronary artery bypass grafting in patients with atheromatous aortic disease. J Thorac Cardiovasc Surg 2004 127 : 406 13.
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 406-413
    • Sharony, R.1    Grossi, E.A.2    Saunders, P.C.3
  • 20
    • 0026642567 scopus 로고
    • Atheroembolism from the ascending aorta. An emerging problem in cardiac surgery
    • Blauth CI, Cosgrove DM, Webb BW, et al. Atheroembolism from the ascending aorta. An emerging problem in cardiac surgery. J Thorac Cardiovasc Surg 1992 103 : 1104 12.
    • (1992) J Thorac Cardiovasc Surg , vol.103 , pp. 1104-1112
    • Blauth, C.I.1    Cosgrove, D.M.2    Webb, B.W.3
  • 21
    • 0034113461 scopus 로고    scopus 로고
    • Ultrasonographic demonstration of manipulation-related aortic injuries after cardiac surgery
    • Ura M, Sakata R, Nakayama Y, Goto T. Ultrasonographic demonstration of manipulation-related aortic injuries after cardiac surgery. J Am Coll Cardiol 2000 35 : 1303 10.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 1303-1310
    • Ura, M.1    Sakata, R.2    Nakayama, Y.3    Goto, T.4
  • 22
    • 0016484777 scopus 로고
    • Location of early atherosclerotic lesions in the aortic arch in the light of fluid flow
    • Rodkiewicz CM. Location of early atherosclerotic lesions in the aortic arch in the light of fluid flow. J Biomech 1975 8 : 149 56.
    • (1975) J Biomech , vol.8 , pp. 149-156
    • Rodkiewicz, C.M.1
  • 23
    • 0027689347 scopus 로고
    • Flow dynamics in the human aorta
    • Chandran KB. Flow dynamics in the human aorta. J Biomech Eng 1993 115 : 611 6.
    • (1993) J Biomech Eng , vol.115 , pp. 611-616
    • Chandran, K.B.1
  • 24
    • 0035133894 scopus 로고    scopus 로고
    • Left hemispheric strokes in coronary surgery: Implications for end-hole aortic cannulas
    • Weinstein GS. Left hemispheric strokes in coronary surgery: implications for end-hole aortic cannulas. Ann Thorac Surg 2001 71 : 128 32.
    • (2001) Ann Thorac Surg , vol.71 , pp. 128-132
    • Weinstein, G.S.1
  • 25
    • 0036435827 scopus 로고    scopus 로고
    • Is there any impact of the shape of aortic end-hole cannula on stroke occurrence? Clinical evaluation of straight and bent-tip aortic cannulae
    • Albert AA, Beller CJ, Arnrich B, et al. Is there any impact of the shape of aortic end-hole cannula on stroke occurrence? Clinical evaluation of straight and bent-tip aortic cannulae. Perfusion 2002 17 : 451 6.
    • (2002) Perfusion , vol.17 , pp. 451-456
    • Albert, A.A.1    Beller, C.J.2    Arnrich, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.