메뉴 건너뛰기




Volumn 65, Issue 2, 2010, Pages 137-146

Influence of the operating parameters and of the sample introduction system on time correlation of line intensities using an axially viewed CCD-based ICP-AES system

Author keywords

Flicker noise; Internal standardization; Repeatability; Sample introduction system; Shot noise; Time correlation; Ultrasonic nebulization

Indexed keywords

AXIALLY VIEWED; CARRIER GAS FLOW RATES; COMPLEX MATRICES; CORRELATED SIGNALS; EMISSION LINES; EMISSION SPECTROMETRY; HIGH-POWER; ICP-AES; INDUCED DEGRADATION; INTEGRATION TIME; INTERNAL STANDARD METHOD; INTERNAL STANDARDIZATION; LINE INTENSITIES; MATRIX; MULTI-CHANNEL; NOISE LEVELS; NOISE MAGNITUDE; ON TIME; OPERATING PARAMETERS; PLASMA CONDITIONS; REFERENCE LINES; RELATIVE STANDARD DEVIATIONS; SAMPLE INTRODUCTION; SIGNAL COMPENSATION; SOIL SAMPLE; TIME CORRELATIONS; ULTRASONIC NEBULIZATION;

EID: 76749107987     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2009.12.006     Document Type: Article
Times cited : (7)

References (26)
  • 1
    • 44649106562 scopus 로고    scopus 로고
    • Assessment of high precision, high accuracy Inductively Coupled Plasma-Optical Emission Spectroscopy to obtain concentration uncertainties less than 0.2% with variable matrix concentrations
    • Rabb S.A., and Olesik J.W. Assessment of high precision, high accuracy Inductively Coupled Plasma-Optical Emission Spectroscopy to obtain concentration uncertainties less than 0.2% with variable matrix concentrations. Spectrochim. Acta Part B 63 (2008) 244-256
    • (2008) Spectrochim. Acta Part B , vol.63 , pp. 244-256
    • Rabb, S.A.1    Olesik, J.W.2
  • 2
    • 0001420413 scopus 로고    scopus 로고
    • Noise power spectra and recovery rates obtained with different nebulizer systems in ICP atomic emission spectrometric analyses in the case of different types of salts and salt contents
    • Nehm R., and Broekaert J.A.C. Noise power spectra and recovery rates obtained with different nebulizer systems in ICP atomic emission spectrometric analyses in the case of different types of salts and salt contents. Fresenius' J. Anal. Chem. 368 (2000) 156-161
    • (2000) Fresenius' J. Anal. Chem. , vol.368 , pp. 156-161
    • Nehm, R.1    Broekaert, J.A.C.2
  • 3
    • 0343053333 scopus 로고    scopus 로고
    • The influence of true simultaneous internal standardization and background correction on repeatability for laser ablation and the slurry technique coupled to ICP emission spectrometry
    • Nolte J., Scheffler F., Mann S., and Paul M. The influence of true simultaneous internal standardization and background correction on repeatability for laser ablation and the slurry technique coupled to ICP emission spectrometry. J. Anal. Atom. Spectrom. 14 (1999) 597-602
    • (1999) J. Anal. Atom. Spectrom. , vol.14 , pp. 597-602
    • Nolte, J.1    Scheffler, F.2    Mann, S.3    Paul, M.4
  • 5
    • 11644310982 scopus 로고
    • Characterization of noise in inductively coupled plasma emission spectrometry
    • Duursma R.P.J., Smit H.C., and Maessen F.J.M.J. Characterization of noise in inductively coupled plasma emission spectrometry. Anal. Chim. Acta 133 (1981) 393-408
    • (1981) Anal. Chim. Acta , vol.133 , pp. 393-408
    • Duursma, R.P.J.1    Smit, H.C.2    Maessen, F.J.M.J.3
  • 6
    • 4244082516 scopus 로고
    • Pressure measurements in the nebulizer spray chamber of an inductively coupled plasma
    • Belchamber R.M., and Horlick G. Pressure measurements in the nebulizer spray chamber of an inductively coupled plasma. Spectrochim. Acta Part B 36 (1981) 581-583
    • (1981) Spectrochim. Acta Part B , vol.36 , pp. 581-583
    • Belchamber, R.M.1    Horlick, G.2
  • 7
    • 0002508170 scopus 로고
    • Noise-power spectra of optical and acoustic emission signals from an inductively coupled plasma
    • Belchamber R.M., and Horlick G. Noise-power spectra of optical and acoustic emission signals from an inductively coupled plasma. Spectrochim. Acta Part B 37 (1982) 17-27
    • (1982) Spectrochim. Acta Part B , vol.37 , pp. 17-27
    • Belchamber, R.M.1    Horlick, G.2
  • 8
    • 0342612580 scopus 로고
    • Effect of signal integration period on measurement precision in inductively coupled plasma emission spectrometry
    • Belchamber R.M., and Horlick G. Effect of signal integration period on measurement precision in inductively coupled plasma emission spectrometry. Spectrochim. Acta Part B 37 (1982) 71-74
    • (1982) Spectrochim. Acta Part B , vol.37 , pp. 71-74
    • Belchamber, R.M.1    Horlick, G.2
  • 9
    • 0024607260 scopus 로고
    • Observation of the frequency dependence of ICP radiation noise
    • Antanavicius R., Serapinas P., and Simkus P. Observation of the frequency dependence of ICP radiation noise. J. Phys. D: Appl. Phys. 22 (1989) 254-257
    • (1989) J. Phys. D: Appl. Phys. , vol.22 , pp. 254-257
    • Antanavicius, R.1    Serapinas, P.2    Simkus, P.3
  • 10
    • 0025664847 scopus 로고
    • Characterization of noise in inductively coupled plasma-atomic emission spectrometry
    • Goudzwaard M.P., and de Loos-Vollebregt M.T.C. Characterization of noise in inductively coupled plasma-atomic emission spectrometry. Spectrochim. Acta Part B 45 (1990) 887-901
    • (1990) Spectrochim. Acta Part B , vol.45 , pp. 887-901
    • Goudzwaard, M.P.1    de Loos-Vollebregt, M.T.C.2
  • 11
    • 0006440012 scopus 로고
    • Reduction of acoustic noise in ICP emission by the addition of a chimney
    • Easley S.F., Monning C.A., and Hieftje G.M. Reduction of acoustic noise in ICP emission by the addition of a chimney. Appl Spectrosc 45 (1991) 1368-1371
    • (1991) Appl Spectrosc , vol.45 , pp. 1368-1371
    • Easley, S.F.1    Monning, C.A.2    Hieftje, G.M.3
  • 13
    • 0000711355 scopus 로고
    • Theoretical principles of internal standardization in analytical emission spectroscopy
    • Barnett W.B., Fassel V.A., and Kniseley R.N. Theoretical principles of internal standardization in analytical emission spectroscopy. Spectrochim. Acta Part B 10 (1968) 643-664
    • (1968) Spectrochim. Acta Part B , vol.10 , pp. 643-664
    • Barnett, W.B.1    Fassel, V.A.2    Kniseley, R.N.3
  • 14
    • 0020289051 scopus 로고
    • Inductively coupled plasma emission spectrometry with internal standardization and subtraction of plasma background fluctuations
    • Schmidt G.J., and Slavin W. Inductively coupled plasma emission spectrometry with internal standardization and subtraction of plasma background fluctuations. Anal. Chem. 54 (1982) 2491-2495
    • (1982) Anal. Chem. , vol.54 , pp. 2491-2495
    • Schmidt, G.J.1    Slavin, W.2
  • 15
    • 49049123574 scopus 로고
    • Improved performance using internal standardization in inductively-coupled plasma emission spectroscopy
    • Myers S.A., and Tracy D.H. Improved performance using internal standardization in inductively-coupled plasma emission spectroscopy. Spectrochim. Acta Part B 38 (1983) 1227-1253
    • (1983) Spectrochim. Acta Part B , vol.38 , pp. 1227-1253
    • Myers, S.A.1    Tracy, D.H.2
  • 16
    • 0021158473 scopus 로고
    • Correction for drift by internal reference methods in inductively coupled plasma simultaneous multielement analysis
    • Lorber A., Goldbart Z., and Eldan M. Correction for drift by internal reference methods in inductively coupled plasma simultaneous multielement analysis. Anal. Chem. 56 (1984) 43-48
    • (1984) Anal. Chem. , vol.56 , pp. 43-48
    • Lorber, A.1    Goldbart, Z.2    Eldan, M.3
  • 17
    • 0001324474 scopus 로고
    • Real-time internal standardization for inductively coupled plasma atomic emission spectrometry using a custom segmented-array charge coupled device detector
    • Mermet J.M., and Ivaldi J.C. Real-time internal standardization for inductively coupled plasma atomic emission spectrometry using a custom segmented-array charge coupled device detector. J. Anal. Atom. Spectrom. 8 (1993) 795-8014
    • (1993) J. Anal. Atom. Spectrom. , vol.8 , pp. 795-8014
    • Mermet, J.M.1    Ivaldi, J.C.2
  • 18
    • 0034273099 scopus 로고    scopus 로고
    • Effect of the operating parameters on second scale time correlation between lines of the same element using axially viewed inductively coupled plasma-multichannel-based emission spectrometry
    • Chausseau M., Poussel E., and Mermet J.M. Effect of the operating parameters on second scale time correlation between lines of the same element using axially viewed inductively coupled plasma-multichannel-based emission spectrometry. Spectrochim. Acta Part B 55 (2000) 1431-1450
    • (2000) Spectrochim. Acta Part B , vol.55 , pp. 1431-1450
    • Chausseau, M.1    Poussel, E.2    Mermet, J.M.3
  • 19
    • 0034248105 scopus 로고    scopus 로고
    • Influence of time correlation on background correction using multichannel detection in inductively coupled plasma-atomic emission spectrometry
    • Chausseau M., Poussel E., and Mermet J.M. Influence of time correlation on background correction using multichannel detection in inductively coupled plasma-atomic emission spectrometry. Spectrochim. Acta Part B 55 (2000) 1315-1324
    • (2000) Spectrochim. Acta Part B , vol.55 , pp. 1315-1324
    • Chausseau, M.1    Poussel, E.2    Mermet, J.M.3
  • 20
    • 0030260716 scopus 로고    scopus 로고
    • Real-time internal standardization with an axially-viewed inductively coupled plasma for optical emission spectrometry
    • Ivaldi J.C., and Tyson J.F. Real-time internal standardization with an axially-viewed inductively coupled plasma for optical emission spectrometry. Spectrochim. Acta Part B 51 (1996) 1443-1450
    • (1996) Spectrochim. Acta Part B , vol.51 , pp. 1443-1450
    • Ivaldi, J.C.1    Tyson, J.F.2
  • 21
    • 0026201278 scopus 로고
    • Information-based expert systems for atomic emission spectroscopy
    • Pomeroy R.S., Kolczynski J.D., and Denton M.B. Information-based expert systems for atomic emission spectroscopy. Appl. Spectrosc. 7 (1991) 1111-1119
    • (1991) Appl. Spectrosc. , vol.7 , pp. 1111-1119
    • Pomeroy, R.S.1    Kolczynski, J.D.2    Denton, M.B.3
  • 23
  • 24
    • 0000322140 scopus 로고
    • Drift diagnostics in Inductively Coupled Plasma Atomic Emission Spectrometry
    • Carre M., Poussel E., and Mermet J.M. Drift diagnostics in Inductively Coupled Plasma Atomic Emission Spectrometry. J. Anal. Atom. Spectrom. 7 (1992) 791-797
    • (1992) J. Anal. Atom. Spectrom. , vol.7 , pp. 791-797
    • Carre, M.1    Poussel, E.2    Mermet, J.M.3
  • 25
    • 43049094748 scopus 로고    scopus 로고
    • Building and analyzing models from data by stirred tank experiments for investigation of matrix effects caused by inorganic matrices and selection of internal standards in Inductively Coupled Plasma-Atomic Emission Spectroscopy
    • Grotti M., Paredes E., Maestre S., and Todolí J.L. Building and analyzing models from data by stirred tank experiments for investigation of matrix effects caused by inorganic matrices and selection of internal standards in Inductively Coupled Plasma-Atomic Emission Spectroscopy. Spectrochim. Acta Part B 63 (2008) 571-584
    • (2008) Spectrochim. Acta Part B , vol.63 , pp. 571-584
    • Grotti, M.1    Paredes, E.2    Maestre, S.3    Todolí, J.L.4
  • 26
    • 0033906302 scopus 로고    scopus 로고
    • Multivariate investigation of matrix effects in inductively coupled plasma atomic emission spectrometry using pneumatic or ultrasonic nebulization
    • Grotti M., Magi E., and Frache R. Multivariate investigation of matrix effects in inductively coupled plasma atomic emission spectrometry using pneumatic or ultrasonic nebulization. J. Anal. Atom. Spectrom. 15 (2000) 89-95
    • (2000) J. Anal. Atom. Spectrom. , vol.15 , pp. 89-95
    • Grotti, M.1    Magi, E.2    Frache, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.