메뉴 건너뛰기




Volumn 4, Issue 1, 2010, Pages 39-48

High-power integrated stimulator output stages with floating discharge over a wide voltage range for nerve stimulation

Author keywords

Complementary metal x2013; oxide semiconductor (CMOS) switch; Depletion transistor; Floating discharge; High power stimulator; Implantable circuits; Neural recording; Passive discharge; Silicon on insulator (SOI)

Indexed keywords

DEPLETION TRANSISTOR; FLOATING DISCHARGE; HIGH-POWER; NEURAL RECORDINGS; OXIDE SEMICONDUCTOR; PASSIVE DISCHARGE; SILICON-ON-INSULATORS;

EID: 76549090675     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2009.2034138     Document Type: Article
Times cited : (15)

References (18)
  • 1
    • 0028575654 scopus 로고
    • The first 500 patients with sacral anterior root stimulator implants: General description
    • Dec.
    • G. S. Brindley, "The first 500 patients with sacral anterior root stimulator implants: general description," Paraplegia, vol.32, no.12, pp. 795-805, Dec. 1994.
    • (1994) Paraplegia , vol.32 , Issue.12 , pp. 795-805
    • Brindley, G.S.1
  • 2
    • 33846917981 scopus 로고    scopus 로고
    • Control of skeletal muscle force with currents injected via an intrafascicular, microelectrode array
    • Sep.
    • R. Normann, D. McDonnall, and G. G. Clark, "Control of skeletal muscle force with currents injected via an intrafascicular, microelectrode array," in Proc. 27th Int. Conf. IEEE-EMBS, Shanghai, China, Sep. 2005, pp. 7644-7647.
    • (2005) Proc. 27th Int. Conf. IEEE-EMBS, Shanghai, China , pp. 7644-7647
    • Normann, R.1    McDonnall, D.2    Clark, G.G.3
  • 3
    • 0034001259 scopus 로고    scopus 로고
    • A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
    • Mar.
    • A. Branner and R. A. Normann, "A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats," Brain Res. Bull., vol.51, no.4, pp. 293-306, Mar. 2000.
    • (2000) Brain Res. Bull. , vol.51 , Issue.4 , pp. 293-306
    • Branner, A.1    Normann, R.A.2
  • 4
    • 0032916091 scopus 로고    scopus 로고
    • Cuff electrodes for long-term recording of natural sensory information
    • May/Jun.
    • J. J. Struijk, M. Thomsen, J. O. Larsen, and T. Sinkjaer, "Cuff electrodes for long-term recording of natural sensory information," IEEE Eng. Med. Biol. Mag., vol.18, pp. 91-98, May/Jun. 1999.
    • (1999) IEEE Eng. Med. Biol. Mag. , vol.18 , pp. 91-98
    • Struijk, J.J.1    Thomsen, M.2    Larsen, J.O.3    Sinkjaer, T.4
  • 5
    • 0036159631 scopus 로고    scopus 로고
    • Real time drop foot correction using machine learning and natural sensors
    • Jan.
    • M. Hansen, M. Haugland, T. Sinkjaer, and N. Donaldson, "Real time drop foot correction using machine learning and natural sensors," Neuromodulation, vol.5, no.1, pp. 41-53, Jan. 2002.
    • (2002) Neuromodulation , vol.5 , Issue.1 , pp. 41-53
    • Hansen, M.1    Haugland, M.2    Sinkjaer, T.3    Donaldson, N.4
  • 6
    • 0035985402 scopus 로고    scopus 로고
    • Electrical stimulation for the treatment of bladder dysfunction: Current status and future possibilities
    • Jul.
    • S. Jenernik, M. Craggs, W. M. Grill, G. Creasey, and N. J. Rijkhoff, "Electrical stimulation for the treatment of bladder dysfunction: current status and future possibilities," Neurol. Res., vol.24, no.5, pp. 413-430, Jul. 2002.
    • (2002) Neurol. Res. , vol.24 , Issue.5 , pp. 413-430
    • Jenernik, S.1    Craggs, M.2    Grill, W.M.3    Creasey, G.4    Rijkhoff, N.J.5
  • 10
    • 0034283149 scopus 로고    scopus 로고
    • An improved configuration for the reduction of EMG in electrode cuff recordings: A theoretical approach
    • Sep.
    • M. Rahal, J. Winter, J. Taylor, and N. Donaldson, "An improved configuration for the reduction of EMG in electrode cuff recordings: a theoretical approach," IEEE Trans Biomed. Eng., vol.47, no.9, pp. 1281-1284, Sep. 2000.
    • (2000) IEEE Trans Biomed. Eng. , vol.47 , Issue.9 , pp. 1281-1284
    • Rahal, M.1    Winter, J.2    Taylor, J.3    Donaldson, N.4
  • 11
    • 34249282363 scopus 로고    scopus 로고
    • Passive neutralization of myoelectric interference from neural recording tripoles
    • Jun. 2007
    • I. Pachnis, A. Demosthenous, and N. Donaldson, "Passive neutralization of myoelectric interference from neural recording tripoles," IEEE Trans Biomed. Eng., vol.54, no.6, pt. 1, pp. 1067-1074, Jun. 2007.
    • IEEE Trans Biomed. Eng. , vol.54 , Issue.6 PART 1 , pp. 1067-1074
    • Pachnis, I.1    Demosthenous, A.2    Donaldson, N.3
  • 12
    • 49749084876 scopus 로고    scopus 로고
    • Design of an implant for preventing incontinence after spinal cord injury
    • Aug.
    • N. Donaldson, T. Perkins, I. Pachnis, A. Vanhoest, and A. Demosthenous, "Design of an implant for preventing incontinence after spinal cord injury," Artif. Organs, vol.32, no.8, pp. 586-591, Aug. 2008.
    • (2008) Artif. Organs , vol.32 , Issue.8 , pp. 586-591
    • Donaldson, N.1    Perkins, T.2    Pachnis, I.3    Vanhoest, A.4    Demosthenous, A.5
  • 13
    • 0022635405 scopus 로고
    • When are actively-balanced biphasic ('Lilly') stimulating pulses necessary in neurological prostheses? Part I: Historical background; Pt resting potential; Q studies
    • Jan.
    • N. N. de Donaldson and P. E. K. Donaldson, "When are actively-balanced biphasic ('Lilly') stimulating pulses necessary in neurological prostheses? Part I: Historical background; Pt resting potential; Q studies," Med. Biol. Eng. Comput., vol.24, no.1, pp. 41-49, Jan. 1986.
    • (1986) Med. Biol. Eng. Comput. , vol.24 , Issue.1 , pp. 41-49
    • De Donaldson, N.N.1    Donaldson, P.E.K.2
  • 14
    • 34548842275 scopus 로고    scopus 로고
    • Charge balancing in functional electrical stimulators: A comparative study
    • New Orleans, LA, May
    • M. Ortmanns, "Charge balancing in functional electrical stimulators: A comparative study," in Proc. IEEE Int. Symp. Circuits Syst., New Orleans, LA, May 2007, pp. 309-312.
    • (2007) Proc. IEEE Int. Symp. Circuits Syst. , pp. 309-312
    • Ortmanns, M.1
  • 16
    • 56349162989 scopus 로고    scopus 로고
    • An integrated implantable stimulator that is fail-safe without off-chip blocking-capacitors
    • Sep.
    • X. Liu, A. Demosthenous, and N. Donaldson, "An integrated implantable stimulator that is fail-safe without off-chip blocking-capacitors, " IEEE Trans. Biomed. Circuits Syst., vol.2, no.3, pp. 231-244, Sep. 2008.
    • (2008) IEEE Trans. Biomed. Circuits Syst. , vol.2 , Issue.3 , pp. 231-244
    • Liu, X.1    Demosthenous, A.2    Donaldson, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.