메뉴 건너뛰기




Volumn 32, Issue 8, 2008, Pages 586-591

Design of an implant for preventing incontinence after spinal cord injury

Author keywords

Battery charger; Conditional neuromodulator; Electroneurogram amplifier; Implant; Implant battery; Medical Implant Communication System; Urinary incontinence

Indexed keywords

ANTENNAS; BUDGET CONTROL; RADIO LINKS; SECONDARY BATTERIES; UROLOGY;

EID: 49749084876     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2008.00606.x     Document Type: Conference Paper
Times cited : (10)

References (9)
  • 1
    • 49749109076 scopus 로고    scopus 로고
    • Finetech Medical Website. Available at:. Accessed June 2008.
    • Finetech Medical Website. Available at: http://www.finetech-medical.co. uk. Accessed June 2008.
  • 2
    • 0036282670 scopus 로고    scopus 로고
    • Neuromodulation through sacral nerve roots 2 to 4 with a Finetech-Brindley sacral posterior and anterior root stimulator
    • Kirkham AP, Knight SL, Craggs MD, Casey AT, Shah PJ. Neuromodulation through sacral nerve roots 2 to 4 with a Finetech-Brindley sacral posterior and anterior root stimulator. Spinal Cord 2002 40 : 272 81.
    • (2002) Spinal Cord , vol.40 , pp. 272-281
    • Kirkham, A.P.1    Knight, S.L.2    Craggs, M.D.3    Casey, A.T.4    Shah, P.J.5
  • 3
    • 24944498495 scopus 로고    scopus 로고
    • Intraoperative recording of electroneurographic signals from cuff electrodes on extradural sacral roots in spinal cord injured patients
    • Kurstjens M, Borau A, Rodriguez A, Rijkhoff NJ, Sinkjaer T. Intraoperative recording of electroneurographic signals from cuff electrodes on extradural sacral roots in spinal cord injured patients. J Urol 2005 174 : 1482 7.
    • (2005) J Urol , vol.174 , pp. 1482-1487
    • Kurstjens, M.1    Borau, A.2    Rodriguez, A.3    Rijkhoff, N.J.4    Sinkjaer, T.5
  • 4
    • 0026883619 scopus 로고
    • Closed-loop class e transcutaneous power and data link for microimplants
    • Troyk PR, Schwan MA. Closed-loop class E transcutaneous power and data link for microimplants. IEEE Trans Biomed Eng 1992 39 : 589 99.
    • (1992) IEEE Trans Biomed Eng , vol.39 , pp. 589-599
    • Troyk, P.R.1    Schwan, M.A.2
  • 7
    • 0029430551 scopus 로고
    • Tripolar nerve cuff recording: Stimulus artifact, EMG, and the recorded nerve signal
    • Struijk JJ, Thomsen M. Tripolar nerve cuff recording: stimulus artifact, EMG, and the recorded nerve signal. IEEE-EMBS 17th Annual Conference 1995 2 : 1105 6.
    • (1995) IEEE-EMBS 17th Annual Conference , vol.2 , pp. 1105-1106
    • Struijk, J.J.1    Thomsen, M.2
  • 8
    • 34249282363 scopus 로고    scopus 로고
    • Passive neutralisation of myoelectric interference from neural recording tripoles
    • Pachnis I, Demosthenous A, Donaldson N. Passive neutralisation of myoelectric interference from neural recording tripoles. IEEE Trans Biomed Eng 2007 54 : 1067 74.
    • (2007) IEEE Trans Biomed Eng , vol.54 , pp. 1067-1074
    • Pachnis, I.1    Demosthenous, A.2    Donaldson, N.3
  • 9
    • 49749153102 scopus 로고    scopus 로고
    • Zarlink Semiconductor Website. Available at:. Accessed June 2008.
    • Zarlink Semiconductor Website. Available at: http://products.zarlink.com/ product_profiles/ZL70101.htm. Accessed June 2008.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.