메뉴 건너뛰기




Volumn 13, Issue 1, 2010, Pages 71-78

Comparison of clonazepam compliance by measurement of urinary concentration by immunoassay and LC-MS/MS in pain management population

Author keywords

7 aminoclonazepam; Clonazepam; Immunoassay; LC MS MS; Pain management; Patient compliance

Indexed keywords

ALPRAZOLAM; AMANTADINE; AMFEBUTAMONE; AMITRIPTYLINE; AMPHETAMINE; ATOMOXETINE; BENZOCAINE; BENZOYLECGONINE; BUPIVACAINE; BUPRENORPHINE; BUTALBITAL; CARBAMAZEPINE; CARISOPRODOL; CHLORDIAZEPOXIDE; CHLORPHENIRAMINE; CITALOPRAM; CLOMIPRAMINE; CLONAZEPAM; CLONIDINE; KETAMINE; LAMOTRIGINE; LIDOCAINE; LORAZEPAM; LOXAPINE; MECLOZINE; MEPROBAMATE; MESORIDAZINE; PETHIDINE; PHENAZONE; UNINDEXED DRUG;

EID: 76149121495     PISSN: 15333159     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (45)

References (33)
  • 1
    • 9444280220 scopus 로고    scopus 로고
    • Patterns of illicit drug use and opioid abuse in patients with chronic pain at initial evaluation: A prospective observational study
    • Manchikanti L, Damron KS, McManus C, Barnhill R. Patterns of illicit drug use and opioid abuse in patients with chronic pain at initial evaluation: a prospective observational study. Pain Physician 2004; 7: 431-437.
    • (2004) Pain Physician , vol.7 , pp. 431-437
    • Manchikanti, L.1    Damron, K.S.2    McManus, C.3    Barnhill, R.4
  • 2
    • 43649086356 scopus 로고    scopus 로고
    • Monitoring opioid adherence in chronic pain patients: Tools, techniques, and utility
    • Manchikanti L, Atluri S, Trescot AM, Giordano J. Monitoring opioid adherence in chronic pain patients: tools, techniques, and utility. Pain Physician. 2008; 11:S155-S180.
    • (2008) Pain Physician , vol.11
    • Manchikanti, L.1    Atluri, S.2    Trescot, A.M.3    Giordano, J.4
  • 3
    • 23644440298 scopus 로고    scopus 로고
    • Evaluation of abuse of prescription and illicit drugs in chronic pain patients receiving short acting (hydrocodone) or long acting (methadone) opioids
    • Manchikanti L, Manchukonda R, Pampati V, Damron KS. Evaluation of abuse of prescription and illicit drugs in chronic pain patients receiving short acting (hydrocodone) or long acting (methadone) opioids. Pain Physician 2005; 8:257-261.
    • (2005) Pain Physician , vol.8 , pp. 257-261
    • Manchikanti, L.1    Manchukonda, R.2    Pampati, V.3    Damron, K.S.4
  • 4
    • 43649102347 scopus 로고    scopus 로고
    • Opioids in the management of chronic non-cancer pain: An update of American Society of the Interventional Pain Physicians' (ASIPP) guidelines
    • Trescot AM, Helm S, Hansen H, Benyamin R, Glaser SE, Adlaka R, Patel S, Manchikanti L. Opioids in the management of chronic non-cancer pain: An update of American Society of the Interventional Pain Physicians' (ASIPP) guidelines. Pain Physician 2008; 11:S5-S62.
    • (2008) Pain Physician , vol.11
    • Trescot, A.M.1    Helm, S.2    Hansen, H.3    Benyamin, R.4    Glaser, S.E.5    Adlaka, R.6    Patel, S.7    Manchikanti, L.8
  • 5
    • 43649101761 scopus 로고    scopus 로고
    • Therapeutic opioids: A ten-year perspective on the complexities and complications of the escalating use, abuse, and nonmedical use of opioids
    • Manchikanti L, Singh A. Therapeutic opioids: A ten-year perspective on the complexities and complications of the escalating use, abuse, and nonmedical use of opioids. Pain Physician 2008; 11:S63-S88.
    • (2008) Pain Physician , vol.11
    • Manchikanti, L.1    Singh, A.2
  • 8
    • 57149110840 scopus 로고    scopus 로고
    • Increasing deaths from opioid analgesics in the United States: An evaluation in an interventional pain management practice
    • Manchikanti KN, Manchikanti L, Damron KS, Pampati V, Fellows B. Increasing deaths from opioid analgesics in the United States: An evaluation in an interventional pain management practice. J Opioid Manage 2008; 4:271-283.
    • (2008) J Opioid Manage , vol.4 , pp. 271-283
    • Manchikanti, K.N.1    Manchikanti, L.2    Damron, K.S.3    Pampati, V.4    Fellows, B.5
  • 9
    • 63249096644 scopus 로고    scopus 로고
    • Prevalence of side effects of prolonged low or moderate dose opioid therapy with concomitant benzodiazepine and/or antidepressant therapy in chronic non-cancer pain
    • Manchikanti L, Manchikanti KN, Pampati V, Cash, KA. Prevalence of side effects of prolonged low or moderate dose opioid therapy with concomitant benzodiazepine and/or antidepressant therapy in chronic non-cancer pain. Pain Physician 2009; 12:259-267.
    • (2009) Pain Physician , vol.12 , pp. 259-267
    • Manchikanti, L.1    Manchikanti, K.N.2    Pampati, V.3    Cash, K.A.4
  • 10
    • 84865443848 scopus 로고    scopus 로고
    • Accessed 1/4/2010
    • Drugs.com Klonopin. www.drugs.com/pdr/klonopin.html. Accessed 1/4/2010.
    • Drugs.com Klonopin
  • 12
    • 76149133587 scopus 로고    scopus 로고
    • Fraser AD. Psychotropic agents: the benzodiazepines. In Shaw LM, Kwong TC, Rosano TG, Orsolak PJ, Wolf BA, & Magnani B (eds) The Clinical Toxicology Laboratory. Contemporary Practice Of Poisoning Evaluation. 2001. AACC Press. Washington, DC.
    • Fraser AD. Psychotropic agents: the benzodiazepines. In Shaw LM, Kwong TC, Rosano TG, Orsolak PJ, Wolf BA, & Magnani B (eds) The Clinical Toxicology Laboratory. Contemporary Practice Of Poisoning Evaluation. 2001. AACC Press. Washington, DC.
  • 13
    • 0026525333 scopus 로고
    • Detection of benzodiazepine intake in therapeutic doses by immunoanalysis of urine: Two techniques evaluated and modified for improved performance
    • Beck O, Lafolie P, Hjemdahl P, Borg S, Odelius G, Wirbing P. Detection of benzodiazepine intake in therapeutic doses by immunoanalysis of urine: Two techniques evaluated and modified for improved performance. Clin Chem 1992; 38:271-275.
    • (1992) Clin Chem , vol.38 , pp. 271-275
    • Beck, O.1    Lafolie, P.2    Hjemdahl, P.3    Borg, S.4    Odelius, G.5    Wirbing, P.6
  • 14
    • 0027992953 scopus 로고
    • Optimal enzymatic hydrolysis of urinary benzodiazepine conjugates
    • Meatherall R. Optimal enzymatic hydrolysis of urinary benzodiazepine conjugates. J Anal Toxicol 1994; 18:382-384.
    • (1994) J Anal Toxicol , vol.18 , pp. 382-384
    • Meatherall, R.1
  • 15
    • 0029889163 scopus 로고    scopus 로고
    • Comparative evaluation of five immunoassays for the analysis of alprazolam and triazolam metabolites in urine: Effect of lowering the screening and GC-MS cut-off values
    • Fraser AD, Meatherall R. Comparative evaluation of five immunoassays for the analysis of alprazolam and triazolam metabolites in urine: Effect of lowering the screening and GC-MS cut-off values. J Anal Toxicol 1996; 20:217-223.
    • (1996) J Anal Toxicol , vol.20 , pp. 217-223
    • Fraser, A.D.1    Meatherall, R.2
  • 16
    • 0031756965 scopus 로고    scopus 로고
    • Comparison of four immunoassays for the detection of lorazepam in urine
    • Meatherall R, Fraser AD. Comparison of four immunoassays for the detection of lorazepam in urine. Ther Drug Monit 1998; 20:673-675.
    • (1998) Ther Drug Monit , vol.20 , pp. 673-675
    • Meatherall, R.1    Fraser, A.D.2
  • 19
    • 76149086750 scopus 로고    scopus 로고
    • Microgenics Product package inserts Microgenics Fremont CA. DAU DRI Benzodiazepine Assay
    • Microgenics Product package inserts Microgenics Fremont CA. DAU DRI Benzodiazepine Assay.
  • 20
    • 84865441194 scopus 로고    scopus 로고
    • Immunalysis Corp
    • Agilent Technologies Inc. Determination of benzodiazepines in oral fluid using lc/ms/ms. Agilent application
    • Moore CM, Coulter C, Crompton K. Immunalysis Corp., Zumwalt, M., Agilent Technologies Inc. Determination of benzodiazepines in oral fluid using lc/ms/ms. Agilent application. www.chem.agilent.com/Library/applications/5989-7074EN.pdf
    • Zumwalt, M
    • Moore, C.M.1    Coulter, C.2    Crompton, K.3
  • 21
    • 76149140820 scopus 로고    scopus 로고
    • Target Compound Identification And Quantitation Procedure. Agilent Technologies Inc., Santa Clara, CA [MSD ChemStation Data Analysis] Last Reviewed: Marc 20, 2002.
    • Target Compound Identification And Quantitation Procedure. Agilent Technologies Inc., Santa Clara, CA [MSD ChemStation Data Analysis] Last Reviewed: Marc 20, 2002.
  • 23
    • 0029848431 scopus 로고    scopus 로고
    • Identification of urinary benzodiazepines and their metabolites: Comparison of automated hplc and gc-ms after immunoassay screening of clinical specimens
    • Valentine J, Middleton R, Sparks C. Identification of urinary benzodiazepines and their metabolites: comparison of automated hplc and gc-ms after immunoassay screening of clinical specimens. Journal of Analytical Toxicology 1996; 20:416-424.
    • (1996) Journal of Analytical Toxicology , vol.20 , pp. 416-424
    • Valentine, J.1    Middleton, R.2    Sparks, C.3
  • 24
    • 0030662286 scopus 로고    scopus 로고
    • The online screening technique for urinary benzodiazepines: Comparison with EMIT, FPIA, and GC-MS
    • Beck O, Linn Z, Brodin K, Borg S, Hjemdahl P. The online screening technique for urinary benzodiazepines: Comparison with EMIT, FPIA, and GC-MS. J Anal Toxicol 1997; 21:554-557.
    • (1997) J Anal Toxicol , vol.21 , pp. 554-557
    • Beck, O.1    Linn, Z.2    Brodin, K.3    Borg, S.4    Hjemdahl, P.5
  • 27
    • 0033950038 scopus 로고    scopus 로고
    • Modification of screening immunoassays to detect sub-threshold concentrations of cocaine, cannabinoids, and opiates in urine: Use for detecting maternal and neonatal drug exposures
    • Hattab EM, Goldberger BA, Johannsen LM, Kindland PW, Ticino F, Chronister CW, Bertholf RL. Modification of screening immunoassays to detect sub-threshold concentrations of cocaine, cannabinoids, and opiates in urine: Use for detecting maternal and neonatal drug exposures. Ann Clin Lab Sci 2000; 30:85-91.
    • (2000) Ann Clin Lab Sci , vol.30 , pp. 85-91
    • Hattab, E.M.1    Goldberger, B.A.2    Johannsen, L.M.3    Kindland, P.W.4    Ticino, F.5    Chronister, C.W.6    Bertholf, R.L.7
  • 28
    • 0344198464 scopus 로고    scopus 로고
    • Impact of lowering the screening and confirmation cutoff values for urine drug testing based on dilution indicators
    • Fraser AD, Zamecnik J. Impact of lowering the screening and confirmation cutoff values for urine drug testing based on dilution indicators. Ther Drug Monit 2003; 25:723-727.
    • (2003) Ther Drug Monit , vol.25 , pp. 723-727
    • Fraser, A.D.1    Zamecnik, J.2
  • 31
    • 69849095932 scopus 로고    scopus 로고
    • Evidencebased medicine, systematic reviews, and guidelines in interventional pain management: Part 5. Diagnostic accuracy studies
    • Manchikanti L, Derby R, Wolfer LR, Singh V, Datta S, Hirsch JA. Evidencebased medicine, systematic reviews, and guidelines in interventional pain management: Part 5. Diagnostic accuracy studies. Pain Physician 2009; 12:517-540.
    • (2009) Pain Physician , vol.12 , pp. 517-540
    • Manchikanti, L.1    Derby, R.2    Wolfer, L.R.3    Singh, V.4    Datta, S.5    Hirsch, J.A.6
  • 32
    • 76149106762 scopus 로고    scopus 로고
    • Evidencebased medicine, systematic reviews, and guidelines in interventional pain management: Part 7: Systematic reviews and meta-analyses of diagnostic accuracy studies
    • Manchikanti L, Derby R, Wolfer LR, Singh V, Datta S, Hirsch JA. Evidencebased medicine, systematic reviews, and guidelines in interventional pain management: Part 7: Systematic reviews and meta-analyses of diagnostic accuracy studies. Pain Physician 2009; 12:929-963.
    • (2009) Pain Physician , vol.12 , pp. 929-963
    • Manchikanti, L.1    Derby, R.2    Wolfer, L.R.3    Singh, V.4    Datta, S.5    Hirsch, J.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.