메뉴 건너뛰기




Volumn 25, Issue 6, 2003, Pages 723-727

Impact of Lowering the Screening and Confirmation Cutoff Values for Urine Drug Testing Based on Dilution Indicators

Author keywords

Confirmation; Dilution; Drug testing; Drugs of abuse; Screening

Indexed keywords

AMPHETAMINE; CANNABINOID; COCAINE; CODEINE; MORPHINE; OPIATE; PHENCYCLIDINE;

EID: 0344198464     PISSN: 01634356     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007691-200312000-00011     Document Type: Article
Times cited : (39)

References (10)
  • 1
    • 0035885339 scopus 로고    scopus 로고
    • Experience with urine drug testing by the Correctional Service of Canada
    • Fraser AD, Zamecnik J, Keravel J, et al. Experience with urine drug testing by the Correctional Service of Canada. Forensic Sci Int. 2001;121:16-22.
    • (2001) Forensic Sci Int , vol.121 , pp. 16-22
    • Fraser, A.D.1    Zamecnik, J.2    Keravel, J.3
  • 2
    • 0036150437 scopus 로고    scopus 로고
    • Substance abuse testing by the Correctional Service of Canada
    • Fraser AD, Zamecnik J. Substance abuse testing by the Correctional Service of Canada. Ther Drug Monit. 2002;24:187-191.
    • (2002) Ther Drug Monit , vol.24 , pp. 187-191
    • Fraser, A.D.1    Zamecnik, J.2
  • 3
    • 0026769521 scopus 로고
    • Creatinine analysis in single collection urine specimens
    • Needleman SD, Porvaznik M. Creatinine analysis in single collection urine specimens. J Forensic Sci. 1992;37:1125-1133.
    • (1992) J Forensic Sci , vol.37 , pp. 1125-1133
    • Needleman, S.D.1    Porvaznik, M.2
  • 4
    • 0021916410 scopus 로고
    • Reliability of urinary creatinine as a parameter used to adjust values of urinary biological indicators
    • Alessio LA, Berlin A. Reliability of urinary creatinine as a parameter used to adjust values of urinary biological indicators. Int Arch Occup Environ Health. 1985;55:99-106.
    • (1985) Int Arch Occup Environ Health , vol.55 , pp. 99-106
    • Alessio, L.A.1    Berlin, A.2
  • 5
    • 0035143691 scopus 로고    scopus 로고
    • Adjustment to concentration-dilution of spot urine samples: Correlation between specific gravity and creatinine
    • Carrieri M, Trevisan A. Adjustment to concentration-dilution of spot urine samples: correlation between specific gravity and creatinine. Int Arch Occup Environ Health. 2001;74:63-67.
    • (2001) Int Arch Occup Environ Health , vol.74 , pp. 63-67
    • Carrieri, M.1    Trevisan, A.2
  • 6
    • 0028280442 scopus 로고
    • Replacing creatinine measurements with specific gravity values to adjust urine cotinine concentrations
    • Haddow JE, Knight GJ. Replacing creatinine measurements with specific gravity values to adjust urine cotinine concentrations. Clin Chem. 1994;40: 562-564.
    • (1994) Clin Chem , vol.40 , pp. 562-564
    • Haddow, J.E.1    Knight, G.J.2
  • 7
    • 0036212036 scopus 로고    scopus 로고
    • Use of albumin/creatinine ratio to detect microalbuminuria; implications of sex and race
    • Mattix HJ, Hsu CY. Use of albumin/creatinine ratio to detect microalbuminuria; implications of sex and race. J Am Soc Nephrol. 2002;13:1034-1039.
    • (2002) J Am Soc Nephrol , vol.13 , pp. 1034-1039
    • Mattix, H.J.1    Hsu, C.Y.2
  • 8
    • 0034015141 scopus 로고    scopus 로고
    • Urinary protein and albumin excretion corrected by creatinine and specific gravity
    • Newman DJ, Puglia MJ. Urinary protein and albumin excretion corrected by creatinine and specific gravity. Clin Chem Acta. 2000;294:139-155.
    • (2000) Clin Chem Acta , vol.294 , pp. 139-155
    • Newman, D.J.1    Puglia, M.J.2
  • 9
    • 0344354368 scopus 로고
    • Mandatory guidelines for federal employee drug testing programs
    • June 9
    • Mandatory guidelines for federal employee drug testing programs. Federal Register. 129908-129931, June 9, 1994.
    • (1994) Federal Register , pp. 129908-129931
  • 10
    • 0001288135 scopus 로고
    • Mandatory guidelines for federal workplace drug testing programs
    • April 11
    • Mandatory guidelines for federal workplace drug testing programs, Federal Register. 11970-11989, April 11, 1988.
    • (1988) Federal Register , pp. 11970-11989


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.