메뉴 건너뛰기




Volumn 106, Issue 12, 2009, Pages 1111-1115

Continuous intraocular pressure measurement: First results with a pressure-sensitive contact lens;Kontinuierliche Augeninnendruckmessung: Erste Ergebnisse einer drucksensitiven Kontaktlinse

Author keywords

Continuous pressure curves; Dynamic contour tonometer; Non invasive intraocular pressure measurement; Pressure sensitive contact lens; Vasalva manoeuvre

Indexed keywords

ARTICLE; CONTACT LENS; EQUIPMENT; EQUIPMENT DESIGN; EVALUATION; FEMALE; HUMAN; INSTRUMENTATION; INTRAOCULAR PRESSURE; MALE; METHODOLOGY; MONITORING; OCULOPLETHYSMOGRAPHY; PHYSIOLOGY; PRESSURE; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 75649118869     PISSN: 0941293X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00347-009-1919-z     Document Type: Article
Times cited : (13)

References (15)
  • 1
    • 0034448216 scopus 로고    scopus 로고
    • Large diurnal fluctuations of IOP are an independant risk factor in glaucoma
    • Asrani S, Zeimer R, Wilensky J et al (2000) Large diurnal fluctuations of IOP are an independant risk factor in glaucoma. J Glaucoma 9:134-142
    • (2000) J Glaucoma , vol.9 , pp. 134-142
    • Asrani, S.1    Zeimer, R.2    Wilensky, J.3
  • 2
    • 33846530527 scopus 로고    scopus 로고
    • Fluctuation of intraocular pressure and glaucoma progression in the Early Manifest Glaucoma Trial
    • Bengtosson B, Leske MC, Hyman L et al (2007) Fluctuation of intraocular pressure and glaucoma progression in the Early Manifest Glaucoma Trial. Ophthalmology 114:205-208
    • (2007) Ophthalmology , vol.114 , pp. 205-208
    • Bengtosson, B.1    Leske, M.C.2    Hyman, L.3
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J, Altman D (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307-310
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.1    Altman, D.2
  • 4
    • 0034758591 scopus 로고    scopus 로고
    • Retrobulbar blood flow in glaucoma patients with nocturnal over-dipping in systemic blood pressure
    • Gherghel D, Orgül S, Gugleta K, Flammer J (2001) Retrobulbar blood flow in glaucoma patients with nocturnal over-dipping in systemic blood pressure. Am J Ophthalmol 132:641-647
    • (2001) Am J Ophthalmol , vol.132 , pp. 641-647
    • Gherghel, D.1    Orgül, S.2    Gugleta, K.3    Flammer, J.4
  • 5
    • 75649113553 scopus 로고    scopus 로고
    • Long-term intraocular pressure fluctuation and visual field progression in glaucoma patients with low intraocular pressure after a triple procedure
    • (In press Aug)
    • Hong S, Hong YJ, Seong GJ (In press Aug 2007) Long-term intraocular pressure fluctuation and visual field progression in glaucoma patients with low intraocular pressure after a triple procedure. Arch Ophthalmol
    • (2007) Arch Ophthalmol
    • Hong, S.1    Hong, Y.J.2    Seong, G.J.3
  • 8
    • 33751542908 scopus 로고    scopus 로고
    • Relationship of progression of visual field damage to postural changes in intraocular pressure in patients with normal-tension glaucoma
    • Kiuchi T, Motoyama Y, Oshika T (2006) Relationship of progression of visual field damage to postural changes in intraocular pressure in patients with normal-tension glaucoma. Am A Ophthalmol 113:2150-2155
    • (2006) Am A Ophthalmol , vol.113 , pp. 2150-2155
    • Kiuchi, T.1    Motoyama, Y.2    Oshika, T.3
  • 10
    • 0031057607 scopus 로고    scopus 로고
    • Diurnal intraocular pressure in untreated exfoliation and primary open-angle glaucoma
    • Konstas AG, Mantziris DA, Stewart WC (1997) Diurnal intraocular pressure in untreated exfoliation and primary open-angle glaucoma. Arch Ophthalmol 115(2):182-185
    • (1997) Arch Ophthalmol , vol.115 , Issue.2 , pp. 182-185
    • Konstas, A.G.1    Mantziris, D.A.2    Stewart, W.C.3
  • 11
    • 4344573570 scopus 로고    scopus 로고
    • First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens
    • Leonardi M, Leuenberger P, Bertrana D et al (2004) First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens. Invest Ophthalmol Vis Sci 45:3113-3117
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 3113-3117
    • Leonardi, M.1    Leuenberger, P.2    Bertrana, D.3
  • 12
    • 37349013501 scopus 로고    scopus 로고
    • Clinical comparison of pascal dynamic contour tonometry and goldmann applanation tonometry in asymmetric open-angle glaucoma
    • Sullivan-Mee M, Halverson KD, Qualls C (2007) Clinical comparison of pascal dynamic contour tonometry and goldmann applanation tonometry in asymmetric open-angle glaucoma. J Glaucoma 16(8):694-699
    • (2007) J Glaucoma , vol.16 , Issue.8 , pp. 694-699
    • Sullivan-Mee, M.1    Halverson, K.D.2    Qualls, C.3
  • 14
    • 0033808223 scopus 로고    scopus 로고
    • The Advanced Glaucoma Intervention Study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration
    • The AGIS Investigators (2000) The Advanced Glaucoma Intervention Study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration. Arch Ophthalmol 130(4):429-440
    • (2000) Arch Ophthalmol , vol.130 , Issue.4 , pp. 429-440
    • Investigators, T.A.1
  • 15
    • 0033798256 scopus 로고    scopus 로고
    • Development of a completely encapsulated intraocular pressure sensor
    • Walter P, Schnakenberg U, vom Bögel G et al (2000) Development of a completely encapsulated intraocular pressure sensor. Ophthalmic Res 32(6):278-84
    • (2000) Ophthalmic Res , vol.32 , Issue.6 , pp. 278-284
    • Walter, P.1    Schnakenberg, U.2    vom Bögel, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.