메뉴 건너뛰기




Volumn 20, Issue 3, 2010, Pages 360-363

Revisiting the Ziegler-Nichols process dynamics characterization

Author keywords

PID controller optimization; Process modeling; Ultimate cycle

Indexed keywords

DEADTIME; ESSENTIAL DYNAMICS; FREQUENCY DOMAINS; NYQUIST CURVES; PID CONTROLLERS; PROCESS DYNAMICS; SUSTAINED OSCILLATIONS; UNSTABLE PROCESS;

EID: 75349096671     PISSN: 09591524     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jprocont.2009.08.004     Document Type: Article
Times cited : (44)

References (7)
  • 1
    • 0000756319 scopus 로고
    • Optimum settings for automatic controllers
    • Ziegler J.G., and Nichols N.B. Optimum settings for automatic controllers. Trans. ASME 64 (1942) 759-768
    • (1942) Trans. ASME , vol.64 , pp. 759-768
    • Ziegler, J.G.1    Nichols, N.B.2
  • 2
    • 59649095284 scopus 로고    scopus 로고
    • Optimization of PID controller based on maximization of the proportional gain under constraints on robustness and sensitivity to measurement noise
    • Šekara T.B., and Mataušek M.R. Optimization of PID controller based on maximization of the proportional gain under constraints on robustness and sensitivity to measurement noise. IEEE Trans. Automat. Contr. 54 (2009) 184-189
    • (2009) IEEE Trans. Automat. Contr. , vol.54 , pp. 184-189
    • Šekara, T.B.1    Mataušek, M.R.2
  • 5
    • 0033743836 scopus 로고    scopus 로고
    • Process identifier and its application to industrial control
    • Crowe J., and Johnson M.A. Process identifier and its application to industrial control. IEE Proc. Contr. Theory Appl. 147 (2000) 196-204
    • (2000) IEE Proc. Contr. Theory Appl. , vol.147 , pp. 196-204
    • Crowe, J.1    Johnson, M.A.2
  • 6
    • 0037355243 scopus 로고    scopus 로고
    • Phase-locked loops for plant tuning and monitoring
    • W Clark D., and Park J.W. Phase-locked loops for plant tuning and monitoring. IEE Proc. Contr. Theory Appl. 150 (2003) 155-169
    • (2003) IEE Proc. Contr. Theory Appl. , vol.150 , pp. 155-169
    • W Clark, D.1    Park, J.W.2
  • 7
    • 27144523705 scopus 로고    scopus 로고
    • Evaluation and simple tuning of PID controllers with high-frequency robustness
    • Kristiansson B., and Lennartson B. Evaluation and simple tuning of PID controllers with high-frequency robustness. J. Process Contr. 16 (2006) 91-102
    • (2006) J. Process Contr. , vol.16 , pp. 91-102
    • Kristiansson, B.1    Lennartson, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.