메뉴 건너뛰기




Volumn 24, Issue 6, 2009, Pages 596-603

New advances in cardiac computed tomography

Author keywords

Atherosclerosis; Computed tomography angiography; Coronary artery; Endothelial shear stress; Multidetector computed tomography; Novel imaging

Indexed keywords

BETA ADRENERGIC RECEPTOR BLOCKING AGENT; CONTRAST MEDIUM; IODINATED CONTRAST MEDIUM; IODINE;

EID: 74249113916     PISSN: 02684705     EISSN: None     Source Type: Journal    
DOI: 10.1097/HCO.0b013e3283319b84     Document Type: Review
Times cited : (21)

References (49)
  • 1
    • 39349101981 scopus 로고    scopus 로고
    • Cardiac computed tomography: Indications, applications, limitations, and training requirements: Report of a writing group deployed by the working group nuclear cardiology and cardiac CT of the european society of cardiology and the european council of nuclear cardiology
    • A review article from a writing group that has a comprehensive approach to cardiac CT and includes pooled test characteristics from 64-detector row technology
    • Schroeder S, Achenbach S, Bengel F, et al. Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology. Eur Heart J 2008; 29:531-556. A review article from a writing group that has a comprehensive approach to cardiac CT and includes pooled test characteristics from 64-detector row technology.
    • (2008) Eur Heart J , vol.29 , pp. 531-556
    • Schroeder, S.1    Achenbach, S.2    Bengel, F.3
  • 2
    • 26844549564 scopus 로고    scopus 로고
    • High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography
    • Mollet NR, Cademartiri F, van Mieghem CA, et al. High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation 2005; 112:2318-2323.
    • (2005) Circulation , vol.112 , pp. 2318-2323
    • Mollet, N.R.1    Cademartiri, F.2    Van Mieghem, C.A.3
  • 3
    • 35148867562 scopus 로고    scopus 로고
    • Diagnostic accuracy of dual-source multislice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease
    • Leber AW, Johnson T, Becker A, et al. Diagnostic accuracy of dual-source multislice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease. Eur Heart J 2007; 28:2354-2360.
    • (2007) Eur Heart J , vol.28 , pp. 2354-2360
    • Leber, A.W.1    Johnson, T.2    Becker, A.3
  • 4
    • 54549122949 scopus 로고    scopus 로고
    • Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: Results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial
    • This United States multicenter trial of 64-detector row CT highlights the high NPV using coronary catheterization as a gold standard
    • Budoff MJ, Dowe D, Jollis JG, et al. Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial. J Am Coll Cardiol 2008; 52:1724-1732. This United States multicenter trial of 64-detector row CT highlights the high NPV using coronary catheterization as a gold standard.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 1724-1732
    • Budoff, M.J.1    Dowe, D.2    Jollis, J.G.3
  • 5
    • 57149121037 scopus 로고    scopus 로고
    • Diagnostic performance of coronary angiography by 64-row CT
    • An international multicenter trial of 64-detector row CT that gives test characteristics in comparison with coronary catheterization and includes analyses of patients with obstructive CAD who require revascularization
    • Miller JM, Rochitte CE, Dewey M, et al. Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med 2008; 359:2324-2336. An international multicenter trial of 64-detector row CT that gives test characteristics in comparison with coronary catheterization and includes analyses of patients with obstructive CAD who require revascularization.
    • (2008) N Engl J Med , vol.359 , pp. 2324-2336
    • Miller, J.M.1    Rochitte, C.E.2    Dewey, M.3
  • 6
    • 0031972278 scopus 로고    scopus 로고
    • Iterative reconstruction for helical CT: A simulation study
    • Nuyts J, De Man B, Dupont P, et al. Iterative reconstruction for helical CT: a simulation study. Phys Med Biol 1998; 43:729-737.
    • (1998) Phys Med Biol , vol.43 , pp. 729-737
    • Nuyts, J.1    De Man, B.2    Dupont, P.3
  • 7
    • 34247329383 scopus 로고    scopus 로고
    • Role of noninvasive imaging in the management of coronary artery disease: An assessment of likely change over the next 10 years
    • A report from the British Cardiovascular Society Working Group
    • Gershlick AH, de Belder M, Chambers J, et al. Role of noninvasive imaging in the management of coronary artery disease: an assessment of likely change over the next 10 years. A report from the British Cardiovascular Society Working Group. Heart 2007; 93:423-431.
    • (2007) Heart , vol.93 , pp. 423-431
    • Gershlick, A.H.1    De Belder, M.2    Chambers, J.3
  • 8
    • 0035970098 scopus 로고    scopus 로고
    • Intravascular ultrasound: Novel pathophysiological insights and current clinical applications
    • Nissen SE, Yock P. Intravascular ultrasound: novel pathophysiological insights and current clinical applications. Circulation 2001; 103:604-616.
    • (2001) Circulation , vol.103 , pp. 604-616
    • Nissen, S.E.1    Yock, P.2
  • 9
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual-source CT (DSCT) system
    • Flohr TG, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 2006; 16:256-268.
    • (2006) Eur Radiol , vol.16 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3
  • 10
    • 37449003958 scopus 로고    scopus 로고
    • Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography
    • Ropers U, Ropers D, Pflederer T, et al. Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography. J Am Coll Cardiol 2007; 50:2393-2398.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 2393-2398
    • Ropers, U.1    Ropers, D.2    Pflederer, T.3
  • 11
    • 41349096091 scopus 로고    scopus 로고
    • Randomized comparison of 64-slice single-and dual-source computed tomography coronary angiography for the detection of coronary artery disease
    • Achenbach S, Ropers U, Kuettner A, et al. Randomized comparison of 64-slice single-and dual-source computed tomography coronary angiography for the detection of coronary artery disease. JACC Cardiovasc Imagingv 2008; 1:177-186.
    • (2008) JACC Cardiovasc Imagingv , vol.1 , pp. 177-186
    • Achenbach, S.1    Ropers, U.2    Kuettner, A.3
  • 12
    • 43449126798 scopus 로고    scopus 로고
    • Initial evaluation of coronary images from 320-detector row computed tomography
    • An initial study of 320-detector row CT describing technical specifications
    • Rybicki FJ, Otero HJ, Steigner ML, et al. Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging 2008; 24:535-546. An initial study of 320-detector row CT describing technical specifications.
    • (2008) Int J Cardiovasc Imaging , vol.24 , pp. 535-546
    • Rybicki, F.J.1    Otero, H.J.2    Steigner, M.L.3
  • 13
    • 63449097524 scopus 로고    scopus 로고
    • High-pitch spiral acquisition: A new scan mode for coronary CT angiography
    • An initial study of dual-source CT with very high pitch acquisition strategy for cardiac imaging
    • Achenbach S, Marwan M, Schepis T, et al. High-pitch spiral acquisition: a new scan mode for coronary CT angiography. J Cardiovasc Comput Tomogr 2009; 3:117-121. An initial study of dual-source CT with very high pitch acquisition strategy for cardiac imaging.
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 117-121
    • Achenbach, S.1    Marwan, M.2    Schepis, T.3
  • 14
    • 56949100981 scopus 로고    scopus 로고
    • Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography
    • Steigner ML, Otero HJ, Cai T, et al. Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography. Int J Cardiovasc Imaging 2009; 25:85-90.
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 85-90
    • Steigner, M.L.1    Otero, H.J.2    Cai, T.3
  • 15
    • 59049085443 scopus 로고    scopus 로고
    • The 'post64' era of coronary CT angiography: Understanding new technology from physical principles
    • A review of scanner technology introduced after 64-detector row and dual-source CT
    • Otero HJ, Steigner ML, Rybicki FJ, et al. The 'post64' era of coronary CT angiography: understanding new technology from physical principles. Radiol Clin North Am 2009; 47:79-90. A review of scanner technology introduced after 64-detector row and dual-source CT.
    • (2009) Radiol Clin North Am , vol.47 , pp. 79-90
    • Otero, H.J.1    Steigner, M.L.2    Rybicki, F.J.3
  • 16
    • 67849092675 scopus 로고    scopus 로고
    • Prediction of coronary artery plaque progression and potential rupture from 320-detector row prospectively ECG-gated single heart beat CT angiography: Lattice Boltzmann evaluation of endothelial shear stress
    • An initial study of single-heartbeat CT vascular profiling using 320-detector row technology. This study introduces the Lattice-Boltzmann method to analyze the entire coronary tree; earlier methods could only assess single vessels
    • Rybicki FJ, Melchionna S, Mitsouras D, et al. Prediction of coronary artery plaque progression and potential rupture from 320-detector row prospectively ECG-gated single heart beat CT angiography: Lattice Boltzmann evaluation of endothelial shear stress. Int J Cardiovasc Imaging 2009; 25:289-299. An initial study of single-heartbeat CT vascular profiling using 320-detector row technology. This study introduces the Lattice-Boltzmann method to analyze the entire coronary tree; earlier methods could only assess single vessels.
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 289-299
    • Rybicki, F.J.1    Melchionna, S.2    Mitsouras, D.3
  • 17
    • 25444519367 scopus 로고    scopus 로고
    • Accuracy of MSCT coronary angiography with 64-slice technology: First experience
    • Leschka S, Alkadhi H, Millstine J, et al. Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 2005; 26:1482-1487.
    • (2005) Eur Heart J , vol.26 , pp. 1482-1487
    • Leschka, S.1    Alkadhi, H.2    Millstine, J.3
  • 18
    • 21344460533 scopus 로고    scopus 로고
    • Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: A comparative study with quantitative coronary angiography and intravascular ultrasound
    • Leber AW, Knez A, Klein L, et al. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 2005; 46:147-154.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 147-154
    • Leber, A.W.1    Knez, A.2    Klein, L.3
  • 19
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography
    • Raff GL, Gallagher MJ, Kuettner A, et al. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 2005; 46:552-557.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 552-557
    • Raff, G.L.1    Gallagher, M.J.2    Kuettner, A.3
  • 20
    • 31144447047 scopus 로고    scopus 로고
    • Usefulness of multidetector row spiral computed tomography with 64- x 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses
    • Ropers D, Rixe J, Stolzmann P, et al. Usefulness of multidetector row spiral computed tomography with 64- x 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses. Am J Cardiol 2006; 97:343-348.
    • (2006) Am J Cardiol , vol.97 , pp. 343-348
    • Ropers, D.1    Rixe, J.2    Stolzmann, P.3
  • 22
    • 33744967019 scopus 로고    scopus 로고
    • Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: Influence of calcification
    • Ong TK, Chin SP, Liew CK, et al. Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: influence of calcification. Am Heart J 2006; 151:1323.e1-1323.e6.
    • (2006) Am Heart J , vol.151
    • Ong, T.K.1    Chin, S.P.2    Liew, C.K.3
  • 23
    • 33646102670 scopus 로고    scopus 로고
    • Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: Comparison with conventional invasive angiography
    • Ehara M, Surmely JF, Kawai M, et al. Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J 2006; 70:564-571.
    • (2006) Circ J , vol.70 , pp. 564-571
    • Ehara, M.1    Surmely, J.F.2    Kawai, M.3
  • 24
    • 33747121014 scopus 로고    scopus 로고
    • Accuracy of 64-MDCT in the diagnosis of ischemic heart disease
    • Nikolaou K, Knez A, Rist C, et al. Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. AJR Am J Roentgenol 2006; 187:111-117.
    • (2006) AJR Am J Roentgenol , vol.187 , pp. 111-117
    • Nikolaou, K.1    Knez, A.2    Rist, C.3
  • 25
    • 34547792220 scopus 로고    scopus 로고
    • Reliable high-speed coronary computed tomography in symptomatic patients
    • Weustink AC, Meijboom WB, Mollet NR, et al. Reliable high-speed coronary computed tomography in symptomatic patients. J Am Coll Cardiol 2007; 50:786-794.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 786-794
    • Weustink, A.C.1    Meijboom, W.B.2    Mollet, N.R.3
  • 26
    • 34447550465 scopus 로고    scopus 로고
    • Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: Meta-analysis
    • Vanhoenacker PK, Heijenbrok-Kal MH, Van Heste R, et al. Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis. Radiology 2007; 244:419-428.
    • (2007) Radiology , vol.244 , pp. 419-428
    • Vanhoenacker, P.K.1    Heijenbrok-Kal, M.H.2    Van Heste, R.3
  • 27
    • 22544451261 scopus 로고    scopus 로고
    • Three dimensional computed tomographic imaging in planning the surgical approach for redo cardiac surgery after coronary revascularization
    • Gasparovic H, Rybicki FJ, Millstine J, et al. Three dimensional computed tomographic imaging in planning the surgical approach for redo cardiac surgery after coronary revascularization. Eur J Cardiothorac Surg 2005; 28:244-249.
    • (2005) Eur J Cardiothorac Surg , vol.28 , pp. 244-249
    • Gasparovic, H.1    Rybicki, F.J.2    Millstine, J.3
  • 28
    • 34248659948 scopus 로고    scopus 로고
    • Comparison of multidetector 64-slice computed tomographic angiography to coronary angiography to assess the patency of coronary artery bypass grafts
    • Jabara R, Chronos N, Klein L, et al. Comparison of multidetector 64-slice computed tomographic angiography to coronary angiography to assess the patency of coronary artery bypass grafts. Am J Cardiol 2007; 99:1529-1534.
    • (2007) Am J Cardiol , vol.99 , pp. 1529-1534
    • Jabara, R.1    Chronos, N.2    Klein, L.3
  • 29
    • 33751574663 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation
    • quiz 2334
    • Ropers D, Pohle FK, Kuettner A, et al. Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation. Circulation 2006; 114:2334-2341; quiz 2334.
    • (2006) Circulation , vol.114 , pp. 2334-2341
    • Ropers, D.1    Pohle, F.K.2    Kuettner, A.3
  • 30
    • 65449130063 scopus 로고    scopus 로고
    • Triple rule-out CT in patients with suspicion of acute pulmonary embolism: Findings and accuracy
    • Schertler T, Frauenfelder T, Stolzmann P, et al. Triple rule-out CT in patients with suspicion of acute pulmonary embolism: findings and accuracy. Acad Radiol 2009; 16:708-717.
    • (2009) Acad Radiol , vol.16 , pp. 708-717
    • Schertler, T.1    Frauenfelder, T.2    Stolzmann, P.3
  • 31
    • 49049090804 scopus 로고    scopus 로고
    • Evaluation of a 'triple rule-out' coronary CT angiography protocol: Use of 64-Section CT in low-to-moderate risk emergency department patients suspected of having acute coronary syndrome
    • Takakuwa KM, Halpern EJ. Evaluation of a 'triple rule-out' coronary CT angiography protocol: use of 64-Section CT in low-to-moderate risk emergency department patients suspected of having acute coronary syndrome. Radiology 2008; 248:438-446.
    • (2008) Radiology , vol.248 , pp. 438-446
    • Takakuwa, K.M.1    Halpern, E.J.2
  • 32
    • 64249123624 scopus 로고    scopus 로고
    • Initial experience with a chest pain protocol using 320-slice volume MDCT
    • Hein PA, Romano VC, Lembcke A, et al. Initial experience with a chest pain protocol using 320-slice volume MDCT. Eur Radiol 2009; 19:1148-1155.
    • (2009) Eur Radiol , vol.19 , pp. 1148-1155
    • Hein, P.A.1    Romano, V.C.2    Lembcke, A.3
  • 33
    • 67849094404 scopus 로고    scopus 로고
    • Cardiac CT for acute chest pain in the emergency department: Advantages of prospective triggering
    • Knowles NG, Patel S, Kazerooni EA, et al. Cardiac CT for acute chest pain in the emergency department: advantages of prospective triggering. Int J Cardiovasc Imaging 2009; 25:255-265.
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 255-265
    • Knowles, N.G.1    Patel, S.2    Kazerooni, E.A.3
  • 34
    • 51349168247 scopus 로고    scopus 로고
    • Emergency cardiac CT for suspected acute coronary syndrome: Qualitative and quantitative assessment of coronary, pulmonary, and aortic image quality
    • Dodd JD, Kalva S, Pena A, et al. Emergency cardiac CT for suspected acute coronary syndrome: qualitative and quantitative assessment of coronary, pulmonary, and aortic image quality. AJR Am J Roentgenol 2008; 191:870-877.
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 870-877
    • Dodd, J.D.1    Kalva, S.2    Pena, A.3
  • 35
    • 65249142315 scopus 로고    scopus 로고
    • Coronary computed tomography angiography for early triage of patients with acute chest pain: The ROMICAT (Rule Out Myocardial Infarction using Computer Assisted Tomography) trial
    • A recent study of cardiac CT in patients who present to the emergency room with acute chest pain
    • Hoffmann U, Bamberg F, Chae CU, et al. Coronary computed tomography angiography for early triage of patients with acute chest pain: the ROMICAT (Rule Out Myocardial Infarction using Computer Assisted Tomography) trial. J Am Coll Cardiol 2009; 53:1642-1650. A recent study of cardiac CT in patients who present to the emergency room with acute chest pain.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 1642-1650
    • Hoffmann, U.1    Bamberg, F.2    Chae, C.U.3
  • 36
    • 10344247664 scopus 로고    scopus 로고
    • Pathologic assessment of the vulnerable human coronary plaque
    • Kolodgie FD, Virmani R, Burke AP, et al. Pathologic assessment of the vulnerable human coronary plaque. Heart 2004; 90:1385-1391.
    • (2004) Heart , vol.90 , pp. 1385-1391
    • Kolodgie, F.D.1    Virmani, R.2    Burke, A.P.3
  • 37
    • 67949124844 scopus 로고    scopus 로고
    • Novel clinical applications of state-of-the-art multi-slice computed tomography
    • Schuijf JD, Delgado V, van Werkhoven M, et al. Novel clinical applications of state-of-the-art multi-slice computed tomography. Int J Cardiovasc Imaging 2009; 25:241-254.
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 241-254
    • Schuijf, J.D.1    Delgado, V.2    Van Werkhoven, M.3
  • 38
    • 0034839070 scopus 로고    scopus 로고
    • Noninvasive characterisation of coronary lesion morphology and composition by multislice CT: First results in comparison with intracoronary ultrasound
    • Kopp AF, Schroeder S, Baumbach A, et al. Noninvasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound. Eur Radiol 2001; 11:1607-1611.
    • (2001) Eur Radiol , vol.11 , pp. 1607-1611
    • Kopp, A.F.1    Schroeder, S.2    Baumbach, A.3
  • 39
    • 41949091625 scopus 로고    scopus 로고
    • Head-to-head comparison of coronary plaque evaluation between multislice computed tomography and intravascular ultrasound radiofrequency data analysis
    • A recent study of coronary plaque analysis using CT includes comparison with IVUS
    • Pundziute G, Schuijf JD, Jukema JW, et al. Head-to-head comparison of coronary plaque evaluation between multislice computed tomography and intravascular ultrasound radiofrequency data analysis. JACC Cardiovasc Interv 2008; 1:176-182. A recent study of coronary plaque analysis using CT includes comparison with IVUS.
    • (2008) JACC Cardiovasc Interv , vol.1 , pp. 176-182
    • Pundziute, G.1    Schuijf, J.D.2    Jukema, J.W.3
  • 40
    • 40949122273 scopus 로고    scopus 로고
    • Multidetector computed tomography coronary artery plaque predictors of stress-induced myocardial ischemia by SPECT
    • Lin F, Shaw LJ, Berman DS, et al. Multidetector computed tomography coronary artery plaque predictors of stress-induced myocardial ischemia by SPECT. Atherosclerosis 2008; 197:700-709.
    • (2008) Atherosclerosis , vol.197 , pp. 700-709
    • Lin, F.1    Shaw, L.J.2    Berman, D.S.3
  • 41
    • 33846907809 scopus 로고    scopus 로고
    • Influence of a lipid-lowering therapy on calcified and noncalcified coronary plaques monitored by multislice detector computed tomography: Results of the new age II pilot study
    • Burgstahler C, Reimann A, Beck T, et al. Influence of a lipid-lowering therapy on calcified and noncalcified coronary plaques monitored by multislice detector computed tomography: results of the New Age II Pilot Study. Invest Radiol 2007; 42:189-195.
    • (2007) Invest Radiol , vol.42 , pp. 189-195
    • Burgstahler, C.1    Reimann, A.2    Beck, T.3
  • 42
    • 34249731971 scopus 로고    scopus 로고
    • Noninvasive detection of macrophages using a nanoparticulate contrast agent for computed tomography
    • Hyafil F, Cornily JC, Feig JE, et al. Noninvasive detection of macrophages using a nanoparticulate contrast agent for computed tomography. Nat Med 2007; 13:636-641.
    • (2007) Nat Med , vol.13 , pp. 636-641
    • Hyafil, F.1    Cornily, J.C.2    Feig, J.E.3
  • 43
    • 67949092879 scopus 로고    scopus 로고
    • Cardiac myocardial perfusion imaging using dual source computed tomography
    • Blankstein R, Okada DR, Rocha-Filho JA, et al. Cardiac myocardial perfusion imaging using dual source computed tomography. Int J Cardiovasc Imaging 2009; 25:209-216.
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 209-216
    • Blankstein, R.1    Okada, D.R.2    Rocha-Filho, J.A.3
  • 44
    • 65549157994 scopus 로고    scopus 로고
    • Newer methods for noninvasive assessment of myocardial perfusion: Cardiacmagnetic resonance or cardiac computed tomography?
    • Nagel E, Lima JA, George RT, Kramer CM. Newer methods for noninvasive assessment of myocardial perfusion: cardiacmagnetic resonance or cardiac computed tomography? JACC Cardiovasc Imaging 2009; 2:656-660.
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 656-660
    • Nagel, E.1    Lima, J.A.2    George, R.T.3    Kramer, C.M.4
  • 45
    • 70249150501 scopus 로고    scopus 로고
    • Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: A pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia
    • in press. A comprehensive study of perfusion CT, including evaluations with wide area detector technology
    • George RT, Arbab-Zadeh A, Miller JM, et al. Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia. Circ Cardiovasc Imaging 2009; in press. A comprehensive study of perfusion CT, including evaluations with wide area detector technology.
    • (2009) Circ Cardiovasc Imaging
    • George, R.T.1    Arbab-Zadeh, A.2    Miller, J.M.3
  • 46
    • 40749128479 scopus 로고    scopus 로고
    • Prediction of the localization of high-risk coronary atherosclerotic plaques on the basis of low endothelial shear stress: An intravascular ultrasound and histopathology natural history study
    • Chatzizisis YS, Jonas M, Coskun AU, et al. Prediction of the localization of high-risk coronary atherosclerotic plaques on the basis of low endothelial shear stress: an intravascular ultrasound and histopathology natural history study. Circulation 2008; 117:993-1002.
    • (2008) Circulation , vol.117 , pp. 993-1002
    • Chatzizisis, Y.S.1    Jonas, M.2    Coskun, A.U.3
  • 47
    • 0042140553 scopus 로고    scopus 로고
    • Reproducibility of coronary lumen, plaque, and vessel wall reconstruction and of endothelial shear stress measurements in vivo in humans
    • Coskun AU, Yeghiazarians Y, Kinlay S, et al. Reproducibility of coronary lumen, plaque, and vessel wall reconstruction and of endothelial shear stress measurements in vivo in humans. Catheter Cardiovasc Interv 2003; 60: 67-78.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 67-78
    • Coskun, A.U.1    Yeghiazarians, Y.2    Kinlay, S.3
  • 48
    • 34247871414 scopus 로고    scopus 로고
    • In-vivo flow simulation in coronary arteries based on computed tomography datasets: Feasibility and initial results
    • Frauenfelder T, Boutsianis E, Schertler T, et al. In-vivo flow simulation in coronary arteries based on computed tomography datasets: feasibility and initial results. Eur Radiol 2007; 17:1291-1300.
    • (2007) Eur Radiol , vol.17 , pp. 1291-1300
    • Frauenfelder, T.1    Boutsianis, E.2    Schertler, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.