메뉴 건너뛰기




Volumn 56, Issue 11, 2009, Pages 2482-2491

Polymer microring resonators for high-sensitivity and wideband photoacoustic imaging

Author keywords

[No Author keywords available]

Indexed keywords

2D-ARRAYS; A-CENTER; ACOUSTIC WAVELENGTH; BROADBAND RESPONSE; DETECTOR RESPONSE; HIGH FIDELITY; HIGH FREQUENCY HF; HIGH RESOLUTION; HIGH SPATIAL FREQUENCY; HIGH-SENSITIVITY; IMAGING DEPTH; IMAGING RECONSTRUCTION; INNER STRUCTURE; LASER FLUENCES; LOW-SPATIAL FREQUENCY; MULTISCALES; PHOTO-ACOUSTIC IMAGING; PHOTOACOUSTIC TOMOGRAPHY; POLYMER MICRORING RESONATORS; SIGNAL AVERAGING; ULTRASOUND DETECTION; WIDE-BAND;

EID: 73949145716     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2009.1335     Document Type: Article
Times cited : (39)

References (27)
  • 2
    • 33751312072 scopus 로고    scopus 로고
    • In vivo absorption, scattering, and physiologic properties of 58 malignant breast tumors determined by broadband diffuse optical spectroscopy
    • art. no. 044005 , Jul./aug
    • A. Cerussi, N. Shah, D. Hsiang, A. durkin, J. Butler, and B. J. Tromberg, "In vivo absorption, scattering, and physiologic properties of 58 malignant breast tumors determined by broadband diffuse optical spectroscopy," J. Biomed. Opt., vol. 11, no. 4, art. no. 044005, Jul./aug. 2006.
    • (2006) J. Biomed. Opt , vol.11 , Issue.4
    • Cerussi, A.1    Shah, N.2    Hsiang, D.3    durkin, A.4    Butler, J.5    Tromberg, B.J.6
  • 3
    • 33845370516 scopus 로고    scopus 로고
    • Imaging acute thermal burns by photoacoustic microscopy
    • art. no. 054033, sep./oct
    • H. F. Zhang, K. Maslov, G. Stoica, and L. V. Wang, "Imaging acute thermal burns by photoacoustic microscopy," J. Biomed. Opt., vol. 11, no. 5, art. no. 054033, sep./oct. 2006.
    • (2006) J. Biomed. Opt , vol.11 , Issue.5
    • Zhang, H.F.1    Maslov, K.2    Stoica, G.3    Wang, L.V.4
  • 4
    • 33749424392 scopus 로고    scopus 로고
    • In vivo volumetric imaging of subcutaneous microvasculature by photoacoustic microscopy
    • Oct
    • H. F. Zhang, K. Maslov, M.-L. Li, G. Stoica, and L. V. Wang, "In vivo volumetric imaging of subcutaneous microvasculature by photoacoustic microscopy," Opt. Express, vol. 14, no. 20, pp. 9317-9323, Oct. 2006.
    • (2006) Opt. Express , vol.14 , Issue.20 , pp. 9317-9323
    • Zhang, H.F.1    Maslov, K.2    Li, M.-L.3    Stoica, G.4    Wang, L.V.5
  • 6
    • 0038391518 scopus 로고    scopus 로고
    • Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging for the brain
    • Jul
    • X. Wang, Y. Pang, G. Ku, X. Xie, G. Stoica, and L. V. Wang, "Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging for the brain," Nat. Biotechnol., vol. 21, no. 7, pp. 803-806, Jul. 2003.
    • (2003) Nat. Biotechnol , vol.21 , Issue.7 , pp. 803-806
    • Wang, X.1    Pang, Y.2    Ku, G.3    Xie, X.4    Stoica, G.5    Wang, L.V.6
  • 7
    • 33746453851 scopus 로고    scopus 로고
    • Noninvasive imaging of hemoglobin concentration and oxygenation in the rat brain using high-resolution photoacoustic tomography
    • art. no. 024015, Mar./Apr
    • X. Wang, X. Xie, G. Ku, L. V. Wang, and G. Stoica, "Noninvasive imaging of hemoglobin concentration and oxygenation in the rat brain using high-resolution photoacoustic tomography," J. Biomed. Opt., vol. 11, no. 2, art. no. 024015, Mar./Apr. 2006.
    • (2006) J. Biomed. Opt , vol.11 , Issue.2
    • Wang, X.1    Xie, X.2    Ku, G.3    Wang, L.V.4    Stoica, G.5
  • 8
    • 26844581295 scopus 로고    scopus 로고
    • Thermoacoustic and photoacoustic tomography of thick biological tissues toward breast imaging
    • Oct
    • G. Ku, B. D. Fornage, X. Jin, M. Xu, K. K. Hunt, and L. V. Wang, "Thermoacoustic and photoacoustic tomography of thick biological tissues toward breast imaging," Technol. Cancer Res. Treat., vol. 4, no. 5, pp. 559-565, Oct. 2005.
    • (2005) Technol. Cancer Res. Treat , vol.4 , Issue.5 , pp. 559-565
    • Ku, G.1    Fornage, B.D.2    Jin, X.3    Xu, M.4    Hunt, K.K.5    Wang, L.V.6
  • 9
    • 1942520968 scopus 로고    scopus 로고
    • Multiple-bandwidth photoacoustic tomography
    • Mar
    • G. Ku, X. Wang, G. Stoica, and L. V. Wang, "Multiple-bandwidth photoacoustic tomography," Phys. Med. Biol., vol. 49, pp. 1329-1338, Mar. 2004.
    • (2004) Phys. Med. Biol , vol.49 , pp. 1329-1338
    • Ku, G.1    Wang, X.2    Stoica, G.3    Wang, L.V.4
  • 11
  • 12
    • 44049093466 scopus 로고    scopus 로고
    • Low-noise wideband ultrasound detection using polymer microring resonators
    • art. no. 193509, May
    • S.-W. Huang, S.-L. Chen, T. Ling, A. Maxwell, M. O'donnell, L. J. Guo, and S. Ashkenazi, "Low-noise wideband ultrasound detection using polymer microring resonators," Appl. Phys. Lett., vol. 92, no. 19, art. no. 193509, May 2008.
    • (2008) Appl. Phys. Lett , vol.92 , Issue.19
    • Huang, S.-W.1    Chen, S.-L.2    Ling, T.3    Maxwell, A.4    O'donnell, M.5    Guo, L.J.6    Ashkenazi, S.7
  • 13
    • 0036883172 scopus 로고    scopus 로고
    • Polymer micro-ring resonators fabricated by nanoimprint technique
    • Nov./Dec
    • C. Y. Chao and L. J. Guo, "Polymer micro-ring resonators fabricated by nanoimprint technique," J. Vac. Sci. Technol. B, vol. 20, no. 6, pp. 2862-2866, Nov./Dec. 2002.
    • (2002) J. Vac. Sci. Technol. B , vol.20 , Issue.6 , pp. 2862-2866
    • Chao, C.Y.1    Guo, L.J.2
  • 14
    • 0033888678 scopus 로고    scopus 로고
    • Characterisation of a polymer film optical fiber hydrophone for the measurement of ultrasound fields for use in the range 1-20 mHz: A comparison with PVDF needle and membrane hydrophones
    • Jan
    • P. C. Beard, A. Hurrell, and T. N. Mills, "Characterisation of a polymer film optical fiber hydrophone for the measurement of ultrasound fields for use in the range 1-20 mHz: A comparison with PVDF needle and membrane hydrophones," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 47, no. 1, pp. 256-264, Jan. 2000.
    • (2000) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.47 , Issue.1 , pp. 256-264
    • Beard, P.C.1    Hurrell, A.2    Mills, T.N.3
  • 15
    • 0012752163 scopus 로고    scopus 로고
    • Sub-10 nm imprint lithography and applications
    • nov./dec
    • S. Y. Chou, P. R. Krauss, W. Zhang, L. Guo, and L. Zhuang, "Sub-10 nm imprint lithography and applications," J. Vac. Sci. Technol. B, vol. 15, no. 6, pp. 2897-2904, nov./dec. 1997.
    • (1997) J. Vac. Sci. Technol. B , vol.15 , Issue.6 , pp. 2897-2904
    • Chou, S.Y.1    Krauss, P.R.2    Zhang, W.3    Guo, L.4    Zhuang, L.5
  • 16
    • 0042819899 scopus 로고    scopus 로고
    • Time-domain reconstruction algorithms and numerical simulations for thermoacoustic tomography in various geometries
    • Sep
    • M. Xu, Y. Xu, and L. V. Wang, "Time-domain reconstruction algorithms and numerical simulations for thermoacoustic tomography in various geometries," IEEE Trans. Biomed. Eng., vol. 50, no. 9, pp. 1086-1099, Sep. 2003.
    • (2003) IEEE Trans. Biomed. Eng , vol.50 , Issue.9 , pp. 1086-1099
    • Xu, M.1    Xu, Y.2    Wang, L.V.3
  • 17
    • 0036909176 scopus 로고    scopus 로고
    • Photoacoustic tomography of biological tissues with high cross-section resolution: Reconstruction and experiment
    • Dec
    • X. Wang, Y. Xu, M. Xu, S. yokoo, E. S. Fry, and L. V. Wang, "Photoacoustic tomography of biological tissues with high cross-section resolution: reconstruction and experiment," Med. Phys., vol. 29, no. 12, pp. 2799-2805, Dec. 2002.
    • (2002) Med. Phys , vol.29 , Issue.12 , pp. 2799-2805
    • Wang, X.1    Xu, Y.2    Xu, M.3    yokoo, S.4    Fry, E.S.5    Wang, L.V.6
  • 19
    • 28844438544 scopus 로고    scopus 로고
    • Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction
    • art. no. 056605 , May
    • M. Xu and L. V. Wang, "Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction," Phys. Rev. E Stat. Nonlin. Soft Matter Phys., vol. 67, art. no. 056605, May 2003.
    • (2003) Phys. Rev. E Stat. Nonlin. Soft Matter Phys , vol.67
    • Xu, M.1    Wang, L.V.2
  • 20
    • 17644376187 scopus 로고    scopus 로고
    • Optoacoustic imaging using thin polymer étalon
    • art. no. 134102, Mar
    • S. Ashkenazi, Y. Hou, T. Buma, and M. O'donnell, "Optoacoustic imaging using thin polymer étalon," Appl. Phys. Lett., vol. 86, no. 13, art. no. 134102, Mar. 2005.
    • (2005) Appl. Phys. Lett , vol.86 , Issue.13
    • Ashkenazi, S.1    Hou, Y.2    Buma, T.3    O'donnell, M.4
  • 21
    • 1842550440 scopus 로고
    • Photoacoustic monopole radiation in one, two, and three dimensions
    • Dec
    • G. J. Diebold, T. Sun, and M. I. Khan, "Photoacoustic monopole radiation in one, two, and three dimensions," Phys. Rev. Lett., vol. 67, no. 24, pp. 3384-3387, Dec. 1991.
    • (1991) Phys. Rev. Lett , vol.67 , Issue.24 , pp. 3384-3387
    • Diebold, G.J.1    Sun, T.2    Khan, M.I.3
  • 22
    • 0032807503 scopus 로고    scopus 로고
    • A new theoretical approach to photoacoustic signal generation
    • C. G. A. Hoelen and F. F. M. de Mul, "A new theoretical approach to photoacoustic signal generation," J. Acoust. Soc. Am., vol. 106, no. 2, pp. 695-706, 1999.
    • (1999) J. Acoust. Soc. Am , vol.106 , Issue.2 , pp. 695-706
    • Hoelen, C.G.A.1    de Mul, F.F.M.2
  • 23
    • 0030175974 scopus 로고    scopus 로고
    • Sizing emboli in blood using pulse doppler ultrasound - I: Verifcation of the Ebr model
    • Jun
    • M. A. Moehring and J. A. Ritcey, "Sizing emboli in blood using pulse doppler ultrasound - I: verifcation of the Ebr model," IEEE Trans. Biomed. Eng., vol. 43, no. 6, pp. 572-580, Jun. 1996.
    • (1996) IEEE Trans. Biomed. Eng , vol.43 , Issue.6 , pp. 572-580
    • Moehring, M.A.1    Ritcey, J.A.2
  • 24
    • 73949115634 scopus 로고    scopus 로고
    • J. Brandrup, E. H. Immergut, and E. A. Grulke, Polymer Handbook, 2nd ed. New York: Wiley, 1989, p. v-59.
    • J. Brandrup, E. H. Immergut, and E. A. Grulke, Polymer Handbook, 2nd ed. New York: Wiley, 1989, p. v-59.
  • 25
    • 0042443823 scopus 로고
    • Thermodynamic properties of polystyrene and styrene
    • R. W. Warfeld and M. C. Petree, "Thermodynamic properties of polystyrene and styrene," J. of Polym. Sci., vol. 55, no. 162, pp. 497-505, 1961.
    • (1961) J. of Polym. Sci , vol.55 , Issue.162 , pp. 497-505
    • Warfeld, R.W.1    Petree, M.C.2
  • 26
    • 32944464430 scopus 로고    scopus 로고
    • Refractive index of tissue measured with confocal microscopy
    • art. no. 044014, Jul./Aug
    • J. J. J. Dirckx, L. C. Kuypers, and W. F. Decraemer, "Refractive index of tissue measured with confocal microscopy," J. Biomed. Opt., vol. 10, no. 4, art. no. 044014, Jul./Aug. 2005.
    • (2005) J. Biomed. Opt , vol.10 , Issue.4
    • Dirckx, J.J.J.1    Kuypers, L.C.2    Decraemer, W.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.