메뉴 건너뛰기




Volumn 10, Issue 4, 2005, Pages

Refractive index of tissue measured with confocal microscopy

Author keywords

Biotissue; Imaging; Optical parameters; Optical tomography; Refractive index

Indexed keywords

ALGORITHM; ANIMAL; ARTICLE; CATTLE; COMPUTER ASSISTED DIAGNOSIS; CONFOCAL MICROSCOPY; CYTOLOGY; EVALUATION; IMAGE ENHANCEMENT; IN VITRO STUDY; METHODOLOGY; PHYSIOLOGY; REFRACTOMETRY; SKELETAL MUSCLE;

EID: 32944464430     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.1993487     Document Type: Article
Times cited : (79)

References (12)
  • 1
    • 0346431316 scopus 로고
    • Modeling and measurements of light propagation in tissue for diagnostic and therapeutic applications
    • NATO American Standards Institute Series, A. Chester, S. Martellucci, and A. M. Scheggi, Eds. Plenum, New York
    • B. C. Wilson, "Modeling and measurements of light propagation in tissue for diagnostic and therapeutic applications," in Laser Systems for Photobiology and Photomedicine, Vol. 252, NATO American Standards Institute Series, A. Chester, S. Martellucci, and A. M. Scheggi, Eds., pp. 13-27, Plenum, New York (1991).
    • (1991) Laser Systems for Photobiology and Photomedicine , vol.252 , pp. 13-27
    • Wilson, B.C.1
  • 3
    • 0025551790 scopus 로고
    • A review of the optical properties of biological tissues
    • W. F. Cheong, S. A. Prahl, and A. J. Welch, "A review of the optical properties of biological tissues," IEEE J. Quantum Electron. 26, 2166-2185 (1990).
    • (1990) IEEE J. Quantum Electron. , vol.26 , pp. 2166-2185
    • Cheong, W.F.1    Prahl, S.A.2    Welch, A.J.3
  • 4
    • 84975602245 scopus 로고
    • Refractive index of some mammalian tissues using a fiber optic cladding method
    • F. P. Bolin, L. E. Preuss, R. C. Taylor, and R. J. Ference, "Refractive index of some mammalian tissues using a fiber optic cladding method," Appl. Opt. 28, 2297-2303 (1989).
    • (1989) Appl. Opt. , vol.28 , pp. 2297-2303
    • Bolin, F.P.1    Preuss, L.E.2    Taylor, R.C.3    Ference, R.J.4
  • 5
    • 69949102288 scopus 로고
    • Determination of the refractive-index of highly scattering human tissue by optical coherence tomography
    • G. J. Tearney, M. E. Brezinski, J. F Southern, B. E. Bouma, M. R. Hee, and J. G. Fujimoto, "Determination of the refractive-index of highly scattering human tissue by optical coherence tomography," Opt. Lett. 20, 2258-2260 (1995).
    • (1995) Opt. Lett. , vol.20 , pp. 2258-2260
    • Tearney, G.J.1    Brezinski, M.E.2    Southern, J.F.3    Bouma, B.E.4    Hee, M.R.5    Fujimoto, J.G.6
  • 6
    • 0001034797 scopus 로고    scopus 로고
    • Measurement method of the refractive index of biotissue by total internal reflection
    • H. Li and S. Xie, "Measurement method of the refractive index of biotissue by internal reflection," Appl. Opt. 35, 1793-1795 (1996). (Pubitemid 126642601)
    • (1996) Applied Optics , vol.35 , Issue.10 , pp. 1793-1795
    • Li, H.1    Xie, S.2
  • 7
    • 2342593893 scopus 로고    scopus 로고
    • Refractive index measurement in human tissue samples
    • V. Tsenova and E. Stoykova, "Refractive index measurement in human tissue samples," Proc. SPIE 5226, 413-417 (2003).
    • (2003) Proc. SPIE 5226 , pp. 413-417
    • Tsenova, V.1    Stoykova, E.2
  • 8
    • 17144402183 scopus 로고    scopus 로고
    • A procedure to determine the correct thickness of an object with confocal microscopy in case of refractive index mismatch
    • DOI 10.1111/j.1365-2818.2005.01457.x
    • L. C. Kuypers, W. F Decraemer, J. J. J. Dirckx, and J. P. Timmermans, "A procedure to determine the correct thickness of an object with confocal microscopy in case of refractive index mismatch," J. Microsc. 218, 68-78 (2005). (Pubitemid 40524170)
    • (2005) Journal of Microscopy , vol.218 , Issue.1 , pp. 68-78
    • Kuypers, L.C.1    Decraemer, W.F.2    Dirckx, J.J.J.3    Timmermans, J.-P.4
  • 9
    • 0002003224 scopus 로고
    • Lens aberrations in confocal fluorescence microscopy
    • J. B. Pawley, Ed. Plenum Press, New York
    • S. W Hell and E. H. K. Stelzer, "Lens aberrations in confocal fluorescence microscopy," in Handbook of Biological Confocal Microscopy, J. B. Pawley, Ed., pp. 347-354, Plenum Press, New York (1995).
    • (1995) Handbook of Biological Confocal Microscopy , pp. 347-354
    • Hell, S.W.1    Stelzer, E.H.K.2
  • 10
    • 0027503192 scopus 로고
    • Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index
    • S. Hell, G. Reiner, C. Cremer, and E. H. K. Stelzer, "Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index," J. Microsc. 169, 391-405 (1993). (Pubitemid 23119683)
    • (1993) Journal of Microscopy , vol.169 , Issue.3 , pp. 391-405
    • Hell, S.1    Reiner, G.2    Cremer, C.3    Stelzer, E.H.K.4
  • 11
    • 6344234795 scopus 로고    scopus 로고
    • A simple method for checking the illumination profile in a laser scanning microscope and the dependence of resolution on this profile
    • L. C. Kuypers, J. J. J. Dirckx, and W. F Decraemer, "A simple method for checking the illumination profile in a laser scanning microscope and the dependence of resolution on this profile," Scanning 26, 256-258 (2004). (Pubitemid 39391814)
    • (2004) Scanning , vol.26 , Issue.5 , pp. 256-258
    • Kuypers, L.C.1    Dirckx, J.J.J.2    Decraemer, W.F.3
  • 12
    • 27644463003 scopus 로고    scopus 로고
    • Thickness distribution of fresh eardrums of cat obtained with confocal microscopy
    • in press
    • L. C. Kuypers, W F Decraemer, J. J. J. Dirckx, and J. P. Timmermans, "Thickness distribution of fresh eardrums of cat obtained with confocal microscopy" JARO, Vol. 6, 3 (in press 2005).
    • (2005) JARO , vol.6 , pp. 3
    • Kuypers, L.C.1    Decraemer, W.F.2    Dirckx, J.J.J.3    Timmermans, J.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.