메뉴 건너뛰기




Volumn 35, Issue 11, 2009, Pages 1833-1842

Determinants of regional ventilation and blood flow in the lung

Author keywords

Gravity; Prone; Pulmonary blood flow; Supine; Ventilation

Indexed keywords

ACUTE LUNG INJURY; ANIMAL; ARTIFICIAL VENTILATION; BIOLOGICAL MODEL; BLOOD FLOW; BREATHING MECHANICS; COMPUTER ASSISTED TOMOGRAPHY; HUMAN; INTENSIVE CARE; LUNG; LUNG CIRCULATION; LUNG COMPLIANCE; LUNG GAS EXCHANGE; LUNG VENTILATION PERFUSION RATIO; METHODOLOGY; PATHOPHYSIOLOGY; PHYSIOLOGY; POSITRON EMISSION TOMOGRAPHY; RADIOGRAPHY; REVIEW; SCINTISCANNING; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY; VASCULAR RESISTANCE; VASCULARIZATION;

EID: 73949133713     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-009-1649-3     Document Type: Review
Times cited : (48)

References (82)
  • 1
    • 62949173926 scopus 로고
    • Lobar alveolar gas concentrations: Effect of body position
    • Martin C, Cline F, Marshall H (1953) Lobar alveolar gas concentrations: effect of body position. J Clin Invest 32:617-621
    • (1953) J Clin Invest , vol.32 , pp. 617-621
    • Martin, C.1    Cline, F.2    Marshall, H.3
  • 2
    • 0010484131 scopus 로고
    • Distribution of ventilation and perfusion in the lobes of the dog's lung in the supine and erect position
    • Rahn H, Sadoul P, Farhi L, Shapiro J (1956) Distribution of ventilation and perfusion in the lobes of the dog's lung in the supine and erect position. J Appl Physiol 8:417-426
    • (1956) J Appl Physiol , vol.8 , pp. 417-426
    • Rahn, H.1    Sadoul, P.2    Farhi, L.3    Shapiro, J.4
  • 3
    • 0013909012 scopus 로고
    • Distribution of pulmonary perfusion in erect man
    • Anthonisen NR, Milic-Emili J (1966) Distribution of pulmonary perfusion in erect man. J Appl Physiol 21:760-766
    • (1966) J Appl Physiol , vol.21 , pp. 760-766
    • Anthonisen, N.R.1    Milic-Emili, J.2
  • 6
    • 0014244526 scopus 로고
    • Effect of lung volume on the distribution of pulmonary blood flow in man
    • Hughes JM, Glazier JB, Maloney JE, West JB (1968) Effect of lung volume on the distribution of pulmonary blood flow in man. Respir Physiol 4:58-72
    • (1968) Respir Physiol , vol.4 , pp. 58-72
    • Hughes, J.M.1    Glazier, J.B.2    Maloney, J.E.3    West, J.B.4
  • 7
    • 0005046409 scopus 로고
    • The effects of the tracheal pressure upon flow: Pressure relations in the vascular bed of isolated lungs
    • Banister J, Torrance RW (1960) The effects of the tracheal pressure upon flow: pressure relations in the vascular bed of isolated lungs. Q J Exp Physiol Cogn Med Sci 45:352-367
    • (1960) Q J Exp Physiol Cogn Med Sci , vol.45 , pp. 352-367
    • Banister, J.1    Torrance, R.W.2
  • 8
    • 0018132636 scopus 로고
    • Regional differences in the lung
    • West JB (1978) Regional differences in the lung. Chest 74:426-437
    • (1978) Chest , vol.74 , pp. 426-437
    • West, J.B.1
  • 10
    • 0014751188 scopus 로고
    • Effect of body position on vertical distribution of pulmonary blood flow
    • Reed JH Jr, Wood EH (1970) Effect of body position on vertical distribution of pulmonary blood flow. J Appl Physiol 28:303-311
    • (1970) J Appl Physiol , vol.28 , pp. 303-311
    • Reed Jr., J.H.1    Wood, E.H.2
  • 11
    • 0022534799 scopus 로고
    • Differences in regional vascular conductances in isolated dog lungs
    • Beck KC, Rehder K (1986) Differences in regional vascular conductances in isolated dog lungs. J Appl Physiol 61:530-538
    • (1986) J Appl Physiol , vol.61 , pp. 530-538
    • Beck, K.C.1    Rehder, K.2
  • 12
    • 0018525275 scopus 로고
    • Regional distribution of pulmonary ventilation and perfusion in the conscious dog [proceedings]
    • Amis TC, Heather JD, Hughes JM, Jones HA, Rhodes CG (1979) Regional distribution of pulmonary ventilation and perfusion in the conscious dog [proceedings]. J Physiol 295:40P
    • (1979) J Physiol , vol.295
    • Amis, T.C.1    Heather, J.D.2    Hughes, J.M.3    Jones, H.A.4    Rhodes, C.G.5
  • 13
    • 0013913609 scopus 로고
    • Effect of gravity on the distribution of pulmonary ventilation
    • Bryan AC, Milic-Emili J, Pengelly D (1966) Effect of gravity on the distribution of pulmonary ventilation. J Appl Physiol 21:778-784
    • (1966) J Appl Physiol , vol.21 , pp. 778-784
    • Bryan, A.C.1    Milic-Emili, J.2    Pengelly, D.3
  • 14
    • 0014864842 scopus 로고
    • Distribution of pulmonary blood flow and ventilation during forward (plus Gx) acceleration
    • Glaister DH (1970) Distribution of pulmonary blood flow and ventilation during forward (plus Gx) acceleration. J Appl Physiol 29:432-439
    • (1970) J Appl Physiol , vol.29 , pp. 432-439
    • Glaister, D.H.1
  • 16
    • 0021683658 scopus 로고
    • Regional differences in expansion in excised dog lung lobes
    • Olson LE, Rodarte JR (1984) Regional differences in expansion in excised dog lung lobes. J Appl Physiol 57:1710-1714
    • (1984) J Appl Physiol , vol.57 , pp. 1710-1714
    • Olson, L.E.1    Rodarte, J.R.2
  • 17
    • 0023574785 scopus 로고
    • Regional ventilation during spontaneous breathing and mechanical ventilation in dogs
    • Hubmayr RD, Rodarte JR, Walters BJ, Tonelli FM (1987) Regional ventilation during spontaneous breathing and mechanical ventilation in dogs. J Appl Physiol 63:2467-2475
    • (1987) J Appl Physiol , vol.63 , pp. 2467-2475
    • Hubmayr, R.D.1    Rodarte, J.R.2    Walters, B.J.3    Tonelli, F.M.4
  • 19
    • 0001311607 scopus 로고
    • Regional differences in gas exchange in the lung of erect man
    • West JB (1962) Regional differences in gas exchange in the lung of erect man. J Appl Physiol 17:893-898
    • (1962) J Appl Physiol , vol.17 , pp. 893-898
    • West, J.B.1
  • 20
    • 0018243824 scopus 로고
    • Distribution of pulmonary ventilation and perfusion during short periods of weightlessness
    • Michels DB, West JB (1978) Distribution of pulmonary ventilation and perfusion during short periods of weightlessness. J Appl Physiol 45:987-998
    • (1978) J Appl Physiol , vol.45 , pp. 987-998
    • Michels, D.B.1    West, J.B.2
  • 21
    • 33846194561 scopus 로고    scopus 로고
    • Visualizing lung function with positron emission tomography
    • Harris RS, Schuster DP (2007) Visualizing lung function with positron emission tomography. J Appl Physiol 102:448-458
    • (2007) J Appl Physiol , vol.102 , pp. 448-458
    • Harris, R.S.1    Schuster, D.P.2
  • 23
    • 33846220208 scopus 로고    scopus 로고
    • Physiological imaging of the lung: Single-photonemission computed tomography (SPECT)
    • Petersson J, Sanchez-Crespo A, Larsson SA, Mure M (2007) Physiological imaging of the lung: single-photonemission computed tomography (SPECT). J Appl Physiol 102:468-476
    • (2007) J Appl Physiol , vol.102 , pp. 468-476
    • Petersson, J.1    Sanchez-Crespo, A.2    Larsson, S.A.3    Mure, M.4
  • 24
    • 33847700911 scopus 로고    scopus 로고
    • Microsphere maps of regional blood flow and regional ventilation
    • Robertson HT, Hlastala MP (2007) Microsphere maps of regional blood flow and regional ventilation. J Appl Physiol 102:1265-1272
    • (2007) J Appl Physiol , vol.102 , pp. 1265-1272
    • Robertson, H.T.1    Hlastala, M.P.2
  • 25
    • 0023615945 scopus 로고
    • Observations with SPECT on the normal regional distribution of pulmonary blood flow in gravity independent planes
    • Lisbona R, Dean GW, Hakim TS (1987) Observations with SPECT on the normal regional distribution of pulmonary blood flow in gravity independent planes. J Nucl Med 28:1758-1762
    • (1987) J Nucl Med , vol.28 , pp. 1758-1762
    • Lisbona, R.1    Dean, G.W.2    Hakim, T.S.3
  • 27
    • 0026094793 scopus 로고
    • Gravity is a minor determinant of pulmonary blood flow distribution
    • Glenny RW, Lamm WJ, Albert RK, Robertson HT (1991) Gravity is a minor determinant of pulmonary blood flow distribution. J Appl Physiol 71:620-629
    • (1991) J Appl Physiol , vol.71 , pp. 620-629
    • Glenny, R.W.1    Lamm, W.J.2    Albert, R.K.3    Robertson, H.T.4
  • 28
    • 57049138345 scopus 로고    scopus 로고
    • Counterpoint: Gravity is not the major factor determining the distribution of blood flow in the healthy human lung
    • discussion 1535-1536
    • Glenny R (2008) Counterpoint: gravity is not the major factor determining the distribution of blood flow in the healthy human lung. J Appl Physiol 104:1533-1535; discussion 1535-1536
    • (2008) J Appl Physiol , vol.104 , pp. 1533-1535
    • Glenny, R.1
  • 29
    • 0033018875 scopus 로고    scopus 로고
    • Gravity is an important but secondary determinant of regional pulmonary blood flow in upright primates
    • Glenny RW, Bernard S, Robertson HT, Hlastala MP (1999) Gravity is an important but secondary determinant of regional pulmonary blood flow in upright primates. J Appl Physiol 86:623-632
    • (1999) J Appl Physiol , vol.86 , pp. 623-632
    • Glenny, R.W.1    Bernard, S.2    Robertson, H.T.3    Hlastala, M.P.4
  • 30
    • 0033870304 scopus 로고    scopus 로고
    • Pulmonary blood flow remains fractal down to the level of gas exchange
    • Glenny RW, Bernard SL, Robertson HT (2000) Pulmonary blood flow remains fractal down to the level of gas exchange. J Appl Physiol 89:742-748
    • (2000) J Appl Physiol , vol.89 , pp. 742-748
    • Glenny, R.W.1    Bernard, S.L.2    Robertson, H.T.3
  • 33
    • 0035100488 scopus 로고    scopus 로고
    • Pulmonary perfusion in supine and prone positions: An electron-beam computed tomography study
    • Jones AT, Hansell DM, Evans TW (2001) Pulmonary perfusion in supine and prone positions: an electron-beam computed tomography study. J Appl Physiol 90:1342-1348
    • (2001) J Appl Physiol , vol.90 , pp. 1342-1348
    • Jones, A.T.1    Hansell, D.M.2    Evans, T.W.3
  • 34
    • 33750985100 scopus 로고    scopus 로고
    • Computational predictions of pulmonary blood flow gradients: Gravity versus structure
    • Burrowes KS, Tawhai MH (2006) Computational predictions of pulmonary blood flow gradients: gravity versus structure. Respir Physiol Neurobiol 154:515-523
    • (2006) Respir Physiol Neurobiol , vol.154 , pp. 515-523
    • Burrowes, K.S.1    Tawhai, M.H.2
  • 35
    • 0028266062 scopus 로고
    • Inhomogeneity of pulmonary perfusion during sustained microgravity on SLS-1
    • Prisk GK, Guy HJ, Elliott AR, West JB (1994) Inhomogeneity of pulmonary perfusion during sustained microgravity on SLS-1. J Appl Physiol 76:1730-1738
    • (1994) J Appl Physiol , vol.76 , pp. 1730-1738
    • Prisk, G.K.1    Guy, H.J.2    Elliott, A.R.3    West, J.B.4
  • 36
    • 19444366115 scopus 로고    scopus 로고
    • Residual heterogeneity of intra- and interregional pulmonary perfusion in short-term microgravity
    • Montmerle S, Sundblad P, Linnarsson D (2005) Residual heterogeneity of intra- and interregional pulmonary perfusion in short-term microgravity. J Appl Physiol 98:2268-2277
    • (2005) J Appl Physiol , vol.98 , pp. 2268-2277
    • Montmerle, S.1    Sundblad, P.2    Linnarsson, D.3
  • 39
    • 0026635496 scopus 로고
    • Spatial correlation of regional pulmonary perfusion
    • Glenny RW (1992) Spatial correlation of regional pulmonary perfusion. J Appl Physiol 72:2378-2386
    • (1992) J Appl Physiol , vol.72 , pp. 2378-2386
    • Glenny, R.W.1
  • 40
    • 0033522952 scopus 로고    scopus 로고
    • The fourth dimension of life: Fractal geometry and allometric scaling of organisms
    • West GB, Brown JH, Enquist BJ (1999) The fourth dimension of life: fractal geometry and allometric scaling of organisms. Science 284:1677-1679
    • (1999) Science , vol.284 , pp. 1677-1679
    • West, G.B.1    Brown, J.H.2    Enquist, B.J.3
  • 41
    • 0030905470 scopus 로고    scopus 로고
    • Spatial pattern of pulmonary blood flow distribution is stable over days
    • Glenny RW, McKinney S, Robertson HT (1997) Spatial pattern of pulmonary blood flow distribution is stable over days. J Appl Physiol 82:902-907
    • (1997) J Appl Physiol , vol.82 , pp. 902-907
    • Glenny, R.W.1    McKinney, S.2    Robertson, H.T.3
  • 43
    • 34249844858 scopus 로고    scopus 로고
    • Quantifying the genetic influence on mammalian vascular tree structure
    • Glenny R, Bernard S, Neradilek B, Polissar N (2007) Quantifying the genetic influence on mammalian vascular tree structure. Proc Natl Acad Sci USA 104:6858-6863
    • (2007) Proc Natl Acad Sci USA , vol.104 , pp. 6858-6863
    • Glenny, R.1    Bernard, S.2    Neradilek, B.3    Polissar, N.4
  • 44
    • 0000782539 scopus 로고    scopus 로고
    • Regional differences in the lung: A changing perspective on blood flow distribution
    • Hlastala MP, Robertson HT (eds) Dekker, New York
    • Glenny RW, Robertson HT (1998) Regional differences in the lung: a changing perspective on blood flow distribution. In: Hlastala MP, Robertson HT (eds) Complexity in structure and function of the lung. Dekker, New York, pp 461-481
    • (1998) Complexity in Structure and Function of the Lung , pp. 461-481
    • Glenny, R.W.1    Robertson, H.T.2
  • 45
    • 45149089608 scopus 로고    scopus 로고
    • Point: Counterpoint: Gravity is/is not the major factor determining the distribution of blood flow in the human lung
    • Wagner WW Jr (2008) Point: Counterpoint: gravity is/is not the major factor determining the distribution of blood flow in the human lung. J Appl Physiol 104:1537
    • (2008) J Appl Physiol , vol.104 , pp. 1537
    • Wagner Jr., W.W.1
  • 47
    • 0034117641 scopus 로고    scopus 로고
    • Fractal nature of regional ventilation distribution
    • Altemeier WA, McKinney S, Glenny RW (2000) Fractal nature of regional ventilation distribution. J Appl Physiol 88:1551-1557
    • (2000) J Appl Physiol , vol.88 , pp. 1551-1557
    • Altemeier, W.A.1    McKinney, S.2    Glenny, R.W.3
  • 48
    • 0026348707 scopus 로고
    • Fractal geometry: A design principle for living organisms
    • Weibel ER (1991) Fractal geometry: a design principle for living organisms. Am J Physiol 261:L361-L369
    • (1991) Am J Physiol , vol.261
    • Weibel, E.R.1
  • 49
    • 0030901730 scopus 로고    scopus 로고
    • Contributions of pulmonary perfusion and ventilation to heterogeneity in V(A)/Q measured by PET
    • Treppo S, Mijailovich SM, Venegas JG (1997) Contributions of pulmonary perfusion and ventilation to heterogeneity in V(A)/Q measured by PET. J Appl Physiol 82:1163-1176
    • (1997) J Appl Physiol , vol.82 , pp. 1163-1176
    • Treppo, S.1    Mijailovich, S.M.2    Venegas, J.G.3
  • 50
    • 0035143503 scopus 로고    scopus 로고
    • Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs
    • Marcucci C, Nyhan D, Simon BA (2001) Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs. J Appl Physiol 90:421-430
    • (2001) J Appl Physiol , vol.90 , pp. 421-430
    • Marcucci, C.1    Nyhan, D.2    Simon, B.A.3
  • 54
    • 0031737065 scopus 로고    scopus 로고
    • Pulmonary gas-exchange analysisbyusing simultaneous deposition of aerosolized and injected microspheres
    • Altemeier WA, Robertson HT, Glenny RW (1998) Pulmonary gas-exchange analysisbyusing simultaneous deposition of aerosolized and injected microspheres. J Appl Physiol 85:2344-2351
    • (1998) J Appl Physiol , vol.85 , pp. 2344-2351
    • Altemeier, W.A.1    Robertson, H.T.2    Glenny, R.W.3
  • 55
    • 33746754164 scopus 로고    scopus 로고
    • Vital capacity, respiratory muscle strength, and pulmonary gas exchange during long-duration exposure to microgravity
    • Prisk GK, Fine JM, Cooper TK, West JB (2006) Vital capacity, respiratory muscle strength, and pulmonary gas exchange during long-duration exposure to microgravity. J Appl Physiol 101:439-447
    • (2006) J Appl Physiol , vol.101 , pp. 439-447
    • Prisk, G.K.1    Fine, J.M.2    Cooper, T.K.3    West, J.B.4
  • 56
    • 0033675580 scopus 로고    scopus 로고
    • Vasomotor tone does not affect perfusion heterogeneity and gas exchange in normal primate lungs during normoxia
    • Glenny RW, Robertson HT, Hlastala MP (2000) Vasomotor tone does not affect perfusion heterogeneity and gas exchange in normal primate lungs during normoxia. J Appl Physiol 89:2263-2267
    • (2000) J Appl Physiol , vol.89 , pp. 2263-2267
    • Glenny, R.W.1    Robertson, H.T.2    Hlastala, M.P.3
  • 57
    • 0034092548 scopus 로고    scopus 로고
    • No apparent effect of nitric oxide on the local matching of pulmonary perfusion and ventilation in awake sheep
    • Melsom MN, Flatebo T, Nicolaysen G (2000) No apparent effect of nitric oxide on the local matching of pulmonary perfusion and ventilation in awake sheep. Acta Physiol Scand 168:361-370
    • (2000) Acta Physiol Scand , vol.168 , pp. 361-370
    • Melsom, M.N.1    Flatebo, T.2    Nicolaysen, G.3
  • 59
    • 0031794923 scopus 로고    scopus 로고
    • Pulmonary response of normal human subjects to inhaled vasodilator substances
    • Brett SJ, Chambers J, Bush A, Rosenthal M, Evans TW (1998) Pulmonary response of normal human subjects to inhaled vasodilator substances. Clin Sci (Lond) 95:621-627
    • (1998) Clin Sci (Lond) , vol.95 , pp. 621-627
    • Brett, S.J.1    Chambers, J.2    Bush, A.3    Rosenthal, M.4    Evans, T.W.5
  • 60
    • 0027418979 scopus 로고
    • Inhaled nitric oxide selectively reverses human hypoxic pulmonary vasoconstriction without causing systemic vasodilation
    • Frostell CG, Blomqvist H, Hedenstierna G, Lundberg J, Zapol WM (1993) Inhaled nitric oxide selectively reverses human hypoxic pulmonary vasoconstriction without causing systemic vasodilation. Anesthesiology 78:427-435
    • (1993) Anesthesiology , vol.78 , pp. 427-435
    • Frostell, C.G.1    Blomqvist, H.2    Hedenstierna, G.3    Lundberg, J.4    Zapol, W.M.5
  • 62
    • 0030934043 scopus 로고    scopus 로고
    • Inhaled nitric oxide (40 ppm) during one-lung ventilation, in the lateral decubitus position, does not decrease pulmonary vascular resistance or improve oxygenation in normal patients
    • Wilson WC, Kapelanski DP, Benumof JL, Newhart JW 2nd, Johnson FW, Channick RN (1997) Inhaled nitric oxide (40 ppm) during one-lung ventilation, in the lateral decubitus position, does not decrease pulmonary vascular resistance or improve oxygenation in normal patients. J Cardiothorac Vasc Anesth 11:172-176
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 172-176
    • Wilson, W.C.1    Kapelanski, D.P.2    Benumof, J.L.3    Newhart II, J.W.4    Johnson, F.W.5    Channick, R.N.6
  • 63
    • 0006205461 scopus 로고    scopus 로고
    • Functional design of the human lung for gas exchange
    • Fishman A (ed) McGraw-Hill, New York
    • Weibel E, Taylor C (1998) Functional design of the human lung for gas exchange. In: Fishman A (ed) Fishman's pulmonary diseaes and disorders. McGraw-Hill, New York, pp 21-61
    • (1998) Fishman's Pulmonary Diseaes and Disorders , pp. 21-61
    • Weibel, E.1    Taylor, C.2
  • 64
    • 13544249881 scopus 로고    scopus 로고
    • Developmental biology of the pulmonary circulation
    • Hislop A (2005) Developmental biology of the pulmonary circulation. Paediatr Respir Rev 6:35-43
    • (2005) Paediatr Respir Rev , vol.6 , pp. 35-43
    • Hislop, A.1
  • 65
    • 0025787971 scopus 로고
    • The concept of symmorphosis: A testable hypothesis of structure-function relationship
    • Weibel ER, Taylor CR, Hoppeler H (1991) The concept of symmorphosis: a testable hypothesis of structure-function relationship. Proc Natl Acad Sci USA 88:10357-10361
    • (1991) Proc Natl Acad Sci USA , vol.88 , pp. 10357-10361
    • Weibel, E.R.1    Taylor, C.R.2    Hoppeler, H.3
  • 68
    • 0029737331 scopus 로고    scopus 로고
    • Endotoxin alters hypoxic pulmonary vasoconstriction in isolated rat lungs
    • Frank DU, Lowson SM, Roos CM, Rich GF (1996) Endotoxin alters hypoxic pulmonary vasoconstriction in isolated rat lungs. J Appl Physiol 81:1316-1322
    • (1996) J Appl Physiol , vol.81 , pp. 1316-1322
    • Frank, D.U.1    Lowson, S.M.2    Roos, C.M.3    Rich, G.F.4
  • 69
    • 0032749418 scopus 로고    scopus 로고
    • Hypoxic pulmonary blood flow redistribution and arterial oxygenation in endotoxin-challenged NOS2-deficient mice
    • Ullrich R, Bloch KD, Ichinose F, Steudel W, Zapol WM (1999) Hypoxic pulmonary blood flow redistribution and arterial oxygenation in endotoxin-challenged NOS2-deficient mice. J Clin Invest 104:1421-1429
    • (1999) J Clin Invest , vol.104 , pp. 1421-1429
    • Ullrich, R.1    Bloch, K.D.2    Ichinose, F.3    Steudel, W.4    Zapol, W.M.5
  • 70
    • 1642364655 scopus 로고
    • Effects of anesthetics on pulmonary gas exchange
    • Stanley T, Sperry R (eds) Kluwer, London
    • Marshall BE (1989) Effects of anesthetics on pulmonary gas exchange. In: Stanley T, Sperry R (eds) Anesthesia and the lung. Kluwer, London, pp 117-125
    • (1989) Anesthesia and the Lung , pp. 117-125
    • Marshall, B.E.1
  • 71
    • 0028318151 scopus 로고
    • Role of hypoxic pulmonary vasoconstriction in pulmonary gas exchange and blood flow distribution. 2. Pathophysiology
    • Marshall BE, Hanson CW, Frasch F, Marshall C (1994) Role of hypoxic pulmonary vasoconstriction in pulmonary gas exchange and blood flow distribution. 2. Pathophysiology. Intensive Care Med 20:379-389
    • (1994) Intensive Care Med , vol.20 , pp. 379-389
    • Marshall, B.E.1    Hanson, C.W.2    Frasch, F.3    Marshall, C.4
  • 72
    • 0023150060 scopus 로고
    • Lung collapse and gas exchange during general anesthesia: Effects of spontaneous breathing, muscle paralysis, and positive end-expiratory pressure
    • Tokics L, Hedenstierna G, Strandberg A, Brismar B, Lundquist H (1987) Lung collapse and gas exchange during general anesthesia: effects of spontaneous breathing, muscle paralysis, and positive end-expiratory pressure. Anesthesiology 66:157-167
    • (1987) Anesthesiology , vol.66 , pp. 157-167
    • Tokics, L.1    Hedenstierna, G.2    Strandberg, A.3    Brismar, B.4    Lundquist, H.5
  • 73
    • 0030880906 scopus 로고    scopus 로고
    • Pulmonary blood flow distribution in sheep: Effects of anesthesia, mechanical ventilation, and change in posture
    • Walther SM, Domino KB, Glenny RW, Hlastala MP (1997) Pulmonary blood flow distribution in sheep: effects of anesthesia, mechanical ventilation, and change in posture. Anesthesiology 87:335-342
    • (1997) Anesthesiology , vol.87 , pp. 335-342
    • Walther, S.M.1    Domino, K.B.2    Glenny, R.W.3    Hlastala, M.P.4
  • 74
    • 0032918853 scopus 로고    scopus 로고
    • Positive end-expiratory pressure redistributes perfusion to dependent lung regions in supine but not in prone lambs
    • Walther SM, Domino KB, Glenny RW, Hlastala MP (1999) Positive end-expiratory pressure redistributes perfusion to dependent lung regions in supine but not in prone lambs. Crit Care Med 27:37-45
    • (1999) Crit Care Med , vol.27 , pp. 37-45
    • Walther, S.M.1    Domino, K.B.2    Glenny, R.W.3    Hlastala, M.P.4
  • 75
    • 0016287166 scopus 로고
    • Effects of anesthesia and paralysis on diaphragmatic mechanics in man
    • Froese AB, Bryan AC (1974) Effects of anesthesia and paralysis on diaphragmatic mechanics in man. Anesthesiology 41:242-255
    • (1974) Anesthesiology , vol.41 , pp. 242-255
    • Froese, A.B.1    Bryan, A.C.2
  • 76
    • 0017332619 scopus 로고
    • Regional intrapulmonary gas distribution in awake and anesthetized-paralyzed man
    • RehderK, Sessler AD, Rodarte JR (1977) Regional intrapulmonary gas distribution in awake and anesthetized-paralyzed man. J Appl Physiol 42:391-402
    • (1977) J Appl Physiol , vol.42 , pp. 391-402
    • Rehder, K.1    Sessler, A.D.2    Rodarte, J.R.3
  • 79
    • 38549145341 scopus 로고    scopus 로고
    • Effect of prone positioning in patients with acute respiratory distress syndrome: A meta-analysis
    • Alsaghir AH, Martin CM (2008) Effect of prone positioning in patients with acute respiratory distress syndrome: a meta-analysis. Crit Care Med 36:603-609
    • (2008) Crit Care Med , vol.36 , pp. 603-609
    • Alsaghir, A.H.1    Martin, C.M.2
  • 80
    • 42549095021 scopus 로고    scopus 로고
    • Effect of mechanical ventilation in the prone position on clinical outcomes in patients with acute hypoxemic respiratory failure: A systematic review and meta-analysis
    • Sud S, Sud M, Friedrich JO, Adhikari NK (2008) Effect of mechanical ventilation in the prone position on clinical outcomes in patients with acute hypoxemic respiratory failure: a systematic review and meta-analysis. CMAJ 178:1153-1161
    • (2008) CMAJ , vol.178 , pp. 1153-1161
    • Sud, S.1    Sud, M.2    Friedrich, J.O.3    Adhikari, N.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.