메뉴 건너뛰기




Volumn 61, Issue 4, 2005, Pages 1227-1242

Improved treatment planning for COMS eye plaques

Author keywords

103Pd; 125I; Dosimetry; Eye plaque; Seed carrier; Silastic

Indexed keywords

ANISOTROPY; APPROXIMATION THEORY; ATTENUATION; DOSIMETRY; MONTE CARLO METHODS; PHOTOELECTRICITY; TUMORS;

EID: 14844310231     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2004.09.062     Document Type: Article
Times cited : (70)

References (29)
  • 1
    • 0034933028 scopus 로고    scopus 로고
    • The COMS randomized trial of iodine 125 brachytherapy for choroidal melanoma: III. Initial mortality findings. COMS Report No. 18
    • Collaborative Ocular Melanoma Study Group
    • Collaborative Ocular Melanoma Study Group The COMS randomized trial of iodine 125 brachytherapy for choroidal melanoma III. Initial mortality findings. COMS Report No. 18 Arch Ophthalmol 119 2001 969 982
    • (2001) Arch Ophthalmol , vol.119 , pp. 969-982
  • 2
    • 0002671289 scopus 로고
    • Ocular melanoma, I-125 plaques
    • R.W. Kline, P.D. Yeakel Ocular melanoma, I-125 plaques [Abstract] Med Phys 14 1987 475
    • (1987) Med Phys , vol.14 , pp. 475
    • Kline, R.W.1    Yeakel, P.D.2
  • 5
    • 0029665666 scopus 로고    scopus 로고
    • 125I seed eye plaque dose distribution including penumbra characteristics
    • 125I seed eye plaque dose distribution including penumbra characteristics Med Phys 23 1996 407 418
    • (1996) Med Phys , vol.23 , pp. 407-418
    • Zerda, A.1    Chiu-Tsao, S.-T.2    Lin, J.3
  • 6
    • 0037605848 scopus 로고    scopus 로고
    • A reanalysis of the Collaborative Ocular Melanoma Study medium tumor trial eye plaque dosimetry
    • A.L. Krintz, W.F. Hanson, G.S. Ibbott, D.S. Followill A reanalysis of the Collaborative Ocular Melanoma Study medium tumor trial eye plaque dosimetry Int J Radiat Oncol Biol Phys 56 2003 889 898
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 889-898
    • Krintz, A.L.1    Hanson, W.F.2    Ibbott, G.S.3    Followill, D.S.4
  • 8
    • 0036891049 scopus 로고    scopus 로고
    • Palladium-103 plaque radiotherapy for choroidal melanoma: An 11 year study
    • P.T. Finger, A. Berson, N. Tracy, A. Szechter Palladium-103 plaque radiotherapy for choroidal melanoma: An 11 year study Int J Radiat Oncol Biol Phys 54 2002 1438 1445
    • (2002) Int J Radiat Oncol Biol Phys , vol.54 , pp. 1438-1445
    • Finger, P.T.1    Berson, A.2    Tracy, N.3    Szechter, A.4
  • 9
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM radiation therapy committee task group no
    • R. Nath, L.L. Anderson, G. Luxton, K.A. Weaver, J.F. Williamson, A.S. Meigooni Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM radiation therapy committee task group no 43. Med Phys 24 1995 209 234
    • (1995) 43. Med Phys , vol.24 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 11
    • 0003523753 scopus 로고    scopus 로고
    • Gaithersburg, MD: National Institute of Standards and Technology; (Originally published as NISTIR 5632, National Institute of Standards and Technology, Gaithersburg, MD; 1995.)
    • Hubbell JH, Seltzer SM. Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients (version 1.03). Available at: http://physics.nist.gov/PhysRefData/XrayMassCoef/cover.html. Gaithersburg, MD: National Institute of Standards and Technology; 1997. (Originally published as NISTIR 5632, National Institute of Standards and Technology, Gaithersburg, MD; 1995.) Accessed in December 2003.
    • (1997) Tables of X-ray Mass Attenuation Coefficients and Mass Energy-absorption Coefficients (Version 1.03)
    • Hubbell, J.H.1    Seltzer, S.M.2
  • 14
    • 0022559909 scopus 로고
    • 125I seed eye plaques
    • 125I seed eye plaques Med Phys 13 1986 78 83
    • (1986) Med Phys , vol.13 , pp. 78-83
    • Weaver, K.A.1
  • 18
    • 0025018351 scopus 로고
    • Film dosimetry analyses on the effect of gold shielding for iodine-125 eye plaque therapy for choroidal melanoma
    • A. Wu, F. Krasin Film dosimetry analyses on the effect of gold shielding for iodine-125 eye plaque therapy for choroidal melanoma Med Phys 17 1990 843 846
    • (1990) Med Phys , vol.17 , pp. 843-846
    • Wu, A.1    Krasin, F.2
  • 20
    • 0029867605 scopus 로고    scopus 로고
    • Direct reading measurement of absorbed dose with plastic scintillators: The general concept and applications to ophthalmic plaque dosimetry
    • D. Flühs, M. Heintz, F. Indenkampen, C. Wieczorek, H. Kolanoski, U. Quast Direct reading measurement of absorbed dose with plastic scintillators The general concept and applications to ophthalmic plaque dosimetry Med Phys 23 1996 427 434
    • (1996) Med Phys , vol.23 , pp. 427-434
    • Flühs, D.1    Heintz, M.2    Indenkampen, F.3    Wieczorek, C.4    Kolanoski, H.5    Quast, U.6
  • 21
    • 0020611771 scopus 로고
    • Some theoretical derivations relating to the tissue dosimetry of brachytherapy nuclides, with particular reference to iodine-125
    • R.G. Dale Some theoretical derivations relating to the tissue dosimetry of brachytherapy nuclides, with particular reference to iodine-125 Med Phys 10 1983 176 183
    • (1983) Med Phys , vol.10 , pp. 176-183
    • Dale, R.G.1
  • 22
    • 0023784058 scopus 로고
    • Dosimetric calculations and measurements of gold plaque ophthalmic irradiators using iridium-192 and iodine-125 seeds
    • G. Luxton, M.A. Astrahan, P. Liggett, D.L. Neblett, D.M. Cohen, Z. Petrovich Dosimetric calculations and measurements of gold plaque ophthalmic irradiators using iridium-192 and iodine-125 seeds Int J Radiat Oncol Biol Phys 15 1988 167 176
    • (1988) Int J Radiat Oncol Biol Phys , vol.15 , pp. 167-176
    • Luxton, G.1    Astrahan, M.A.2    Liggett, P.3    Neblett, D.L.4    Cohen, D.M.5    Petrovich, Z.6
  • 24
    • 0027238604 scopus 로고
    • Tumor localization using fundus view photography for episcleral plaque therapy
    • M.D.C. Evans, M.A. Astrahan, R. Bate Tumor localization using fundus view photography for episcleral plaque therapy Med Phys 20 1993 769 775
    • (1993) Med Phys , vol.20 , pp. 769-775
    • Evans, M.D.C.1    Astrahan, M.A.2    Bate, R.3
  • 26
    • 0035889379 scopus 로고    scopus 로고
    • Dosimetric verification of a dedicated 3D treatment planning system for episcleral plaque therapy
    • S. Knutsen, R. Hafslund, O.R. Monge Dosimetric verification of a dedicated 3D treatment planning system for episcleral plaque therapy Int J Radiat Oncol Biol Phys 51 2001 1159 1166
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 1159-1166
    • Knutsen, S.1    Hafslund, R.2    Monge, O.R.3
  • 27
    • 0038715481 scopus 로고    scopus 로고
    • A patch source model for treatment planning of ruthenium ophthalmic applicators
    • M.A. Astrahan A patch source model for treatment planning of ruthenium ophthalmic applicators Med Phys 30 2003 1219 1228
    • (2003) Med Phys , vol.30 , pp. 1219-1228
    • Astrahan, M.A.1
  • 28
    • 0032891406 scopus 로고    scopus 로고
    • Guidance to users of Nycomed Amersham and North American Scientific Inc: I-125 interstitial sources: Dosimetry and calibration changes, recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Ad Hoc Subcommittee on low-energy seed dosimetry
    • J.F. Williamson, B.M. Coursey, L.A. DeWerd, W.F. Hanson, R. Nath, G. Ibbott Guidance to users of Nycomed Amersham and North American Scientific Inc I-125 interstitial sources: Dosimetry and calibration changes, recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Ad Hoc Subcommittee on low-energy seed dosimetry Med Phys 26 1999 570 572
    • (1999) Med Phys , vol.26 , pp. 570-572
    • Williamson, J.F.1    Coursey, B.M.2    Dewerd, L.A.3    Hanson, W.F.4    Nath, R.5    Ibbott, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.