메뉴 건너뛰기




Volumn 18, Issue 6, 2009, Pages 332-340

Fast image mapping of endoscopic image mosaics with three-dimensional ultrasound image for intrauterine fetal surgery

Author keywords

Endoscope; Fetal surgery; Mapping; Placenta; Ultrasound

Indexed keywords

ARTICLE; BLOOD VESSEL SHUNT; FETUS SURGERY; HUMAN; LASER COAGULATION; PRIORITY JOURNAL; SIMULATION; SURVIVAL RATE; THREE DIMENSIONAL IMAGING; TWIN TWIN TRANSFUSION SYNDROME; ULTRASOUND;

EID: 73349084332     PISSN: 13645706     EISSN: 13652931     Source Type: Journal    
DOI: 10.3109/13645700903201217     Document Type: Article
Times cited : (32)

References (21)
  • 1
    • 0027443963 scopus 로고
    • Twin-to-twin transfusion syndrome: A subset of the twin oligohydramnios-polyhydramnois sequence
    • Bruner JP, Rosemond RL. Twin-to-twin transfusion syndrome: a subset of the twin oligohydramnios-polyhydramnois sequence. Am. J. Obs. Gyne. 1993;169:925-930
    • (1993) Am. J. Obs. Gyne , vol.169 , pp. 925-930
    • Bruner, J.P.1    Rosemond, R.L.2
  • 2
    • 85030307181 scopus 로고    scopus 로고
    • Placental pathophysiology of the twin-to-twin transfusion syndrome
    • Bruner JP, Anderson TL, Rosemond RL. Placental pathophysiology of the twin-to-twin transfusion syndrome. Placenta 1996;19:81-86
    • (1996) Placenta , vol.19 , pp. 81-86
    • Bruner, J.P.1    Anderson, T.L.2    Rosemond, R.L.3
  • 3
    • 0032980077 scopus 로고    scopus 로고
    • Endoscopic laser surgery versus serial amniocenteses in the treatment of severe twin-twin transfusion syndrome
    • DOI 10.1016/S0002-9378(99)70278-4
    • Hecher K, Plath H, Bregenzer T, Hansmann M, et al. Endo-scopic laser surgery versus serial amniocenteses in the treatment of severe twin-twin transfusion syndrome. Am. J. Obst. Gyne. 1999;180:717-724 (Pubitemid 29149152)
    • (1999) American Journal of Obstetrics and Gynecology , vol.180 , Issue.3 I , pp. 717-724
    • Hecher, K.1    Plath, H.2    Bregenzer, T.3    Hansmann, M.4    Hackeloer, B.J.5
  • 4
    • 0025345498 scopus 로고
    • Fetoscopic neodymium: Yag laser occlusion of placental vessels in severe twin-twin transfusion syndrome
    • Lia JED, Cruikshank DP, Keye WR. Fetoscopic neodymium: yag laser occlusion of placental vessels in severe twin-twin transfusion syndrome. Obstetrics & gynecology 1990;75: 1046-1056
    • (1990) Obstetrics & Gynecology , vol.75 , pp. 1046-1056
    • Lia, J.E.D.1    Cruikshank, D.P.2    Keye, W.R.3
  • 5
    • 61349189016 scopus 로고    scopus 로고
    • ICG fuo-rescence endoscope for visualization of the placental vascular network
    • Harada K, Miwa M, Fukuyo T, Watanabe S, et al. ICG fuo-rescence endoscope for visualization of the placental vascular network. Minim Invas Ther & allied Technol. 2009;18:1-5.
    • (2009) Minim Invas Ther & Allied Technol , vol.18 , pp. 1-5
    • Harada, K.1    Miwa, M.2    Fukuyo, T.3    Watanabe, S.4
  • 6
    • 0034521928 scopus 로고    scopus 로고
    • Selective verus non-selective laser photocoagulation of placental vessels in twin-twin transfusion syndrome
    • Quintero RA, Comas C, Bornick PW, Allen MH, et al. Selective verus non-selective laser photocoagulation of placental vessels in twin-twin transfusion syndrome. Ultrasound Obstet gynecol. 2000;16:230-236
    • (2000) Ultrasound Obstet Gynecol , vol.16 , pp. 230-236
    • Quintero, R.A.1    Comas, C.2    Bornick, P.W.3    Allen, M.H.4
  • 7
    • 0034310514 scopus 로고    scopus 로고
    • Design and evaluation of a system for microscope-assisted guided interventions (MagI)
    • Edwards PJ, King AP, Maurer CR, Cunha Jr. DA, et al. Design and evaluation of a system for microscope-assisted guided interventions (MagI). IEEE Trans. Med. Imag. 2000;19: 1082-1093
    • (2000) IEEE Trans. Med. Imag , vol.19 , pp. 1082-1093
    • Edwards, P.J.1    King, A.P.2    Maurer, C.R.3    Cunha Jr., D.A.4
  • 8
    • 0036007865 scopus 로고    scopus 로고
    • Automatic fusion of freehand endoscopic brain images to three-dimensional surfaces creating stereoscopic panoramas
    • Dey D, Gobbi DG, Slomka PJ, Surry Kjm, et al. Automatic fusion of freehand endoscopic brain images to three-dimensional surfaces creating stereoscopic panoramas. IEEE Trans. Medical Imaging 2002;21:23-30.
    • (2002) IEEE Trans. Medical Imaging , vol.21 , pp. 23-30
    • Dey, D.1    Gobbi, D.G.2    Slomka, P.J.3    Kjm, S.4
  • 9
    • 25144489051 scopus 로고    scopus 로고
    • Real-Time Fusion of endoscopic Views with Dynamic 3-D cardiac Images: A Phantom Study
    • Szpala S, Wierzbicki M, Guiraudon G, Peters TM. Real-Time Fusion of endoscopic Views with Dynamic 3-D cardiac Images: a Phantom Study. IEEE Trans. Medical Imaging 2005;24: 1207-1215
    • (2005) IEEE Trans. Medical Imaging , vol.24 , pp. 1207-1215
    • Szpala, S.1    Wierzbicki, M.2    Guiraudon, G.3    Peters, T.M.4
  • 11
    • 0026741340 scopus 로고
    • A fast algorithm for active contours and curvature estimation
    • Williams D, Shah M. A fast algorithm for active contours and curvature estimation. CVGIP: Image Understanding 1992;55:14-26.
    • (1992) CVGIP: Image Understanding , vol.55 , pp. 14-26
    • Williams, D.1    Shah, M.2
  • 12
    • 0027963791 scopus 로고
    • A Simple calibration Procedure for Fish-eye (High Distortion) Lens camera
    • Shah S, Aggarwal JK. A Simple calibration Procedure for Fish-eye (High Distortion) Lens camera. IEEE Icra 1994;4: 3422-3427
    • (1994) IEEE Icra , vol.4 , pp. 3422-3427
    • Shah, S.1    Aggarwal, J.K.2
  • 14
    • 23644439966 scopus 로고    scopus 로고
    • Comparison of calibration methods for spatial tracking of a 3-D ultrasound probe
    • Poon TC, Rohling RN. Comparison of calibration methods for spatial tracking of a 3-D ultrasound probe. Ultrasound in Medicine & biology 2008;31:1095-1108
    • (2008) Ultrasound in Medicine & Biology , vol.31 , pp. 1095-1108
    • Poon, T.C.1    Rohling, R.N.2
  • 15
    • 33750815385 scopus 로고    scopus 로고
    • Quantitative evaluation of Three calibration Methods for 3-D Freehand Ultrasound
    • Rousseau F, Hellier P, Letteboer Mmj, Niessen WJ, et al. Quantitative evaluation of Three calibration Methods for 3-D Freehand Ultrasound. IEEE Trans. On Medical imaging 2006;25:1492-1501
    • (2006) IEEE Trans. on Medical Imaging , vol.25 , pp. 1492-1501
    • Rousseau, F.1    Hellier, P.2    Mmj, L.3    Niessen, W.J.4
  • 18
    • 84886920608 scopus 로고    scopus 로고
    • 3D Slicer, http://www.3d-slicer.org/
    • 3D Slicer
  • 21
    • 12844251890 scopus 로고    scopus 로고
    • Scalable high-resolution integral videography autostereoscopic display by use of seamless multi-projection
    • Liao H, Iwahara M, Koike T, Hata N, et al. Scalable high-resolution integral videography autostereoscopic display by use of seamless multi-projection. Applied Optics 2005;44:305-315
    • (2005) Applied Optics , vol.44 , pp. 305-315
    • Liao, H.1    Iwahara, M.2    Koike, T.3    Hata, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.