메뉴 건너뛰기




Volumn 36, Issue 1, 2010, Pages 87-96

Intraocular lens power calculation after laser refractive surgery. Corrective algorithm for corneal power estimation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; CALCULATION; CLINICAL TRIAL; CONTROLLED STUDY; CORNEA; GERMANY; HUMAN; KERATOMETRY; LASER SURGERY; LENS IMPLANT; LENS POWER; MAJOR CLINICAL STUDY; MYOPIA; POLARIMETRY; POSTOPERATIVE CARE; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; REFRACTIVE SURGERY;

EID: 72049126962     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2009.07.011     Document Type: Article
Times cited : (34)

References (40)
  • 1
    • 0000369832 scopus 로고    scopus 로고
    • Cataract surgery in patients with previous keratorefractive surgery (RK, PRK, and LASIK)
    • Holladay J.T. Cataract surgery in patients with previous keratorefractive surgery (RK, PRK, and LASIK). Ophthalmic Pract 15 (1997) 238-244
    • (1997) Ophthalmic Pract , vol.15 , pp. 238-244
    • Holladay, J.T.1
  • 2
    • 0033498941 scopus 로고    scopus 로고
    • Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy
    • Seitz B., Langenbucher A., Nguyen N.X., Kus M.M., and Küchle M. Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy. Ophthalmology 106 (1999) 693-702
    • (1999) Ophthalmology , vol.106 , pp. 693-702
    • Seitz, B.1    Langenbucher, A.2    Nguyen, N.X.3    Kus, M.M.4    Küchle, M.5
  • 3
    • 62349103924 scopus 로고    scopus 로고
    • Intraocular lens power calculation after previous laser refractive surgery
    • Hoffer K.J. Intraocular lens power calculation after previous laser refractive surgery. J Cataract Refract Surg 35 (2009) 759-765
    • (2009) J Cataract Refract Surg , vol.35 , pp. 759-765
    • Hoffer, K.J.1
  • 4
    • 0034076365 scopus 로고    scopus 로고
    • Intraocular lens power calculation in eyes after corneal refractive surgery
    • Seitz B., and Langenbucher A. Intraocular lens power calculation in eyes after corneal refractive surgery. J Refract Surg 16 (2000) 349-361
    • (2000) J Refract Surg , vol.16 , pp. 349-361
    • Seitz, B.1    Langenbucher, A.2
  • 5
    • 0035147564 scopus 로고    scopus 로고
    • Intra-ocular lens calculation status after corneal refractive surgery
    • Speicher L. Intra-ocular lens calculation status after corneal refractive surgery. Curr Opin Ophthalmol 12 (2001) 17-29
    • (2001) Curr Opin Ophthalmol , vol.12 , pp. 17-29
    • Speicher, L.1
  • 6
    • 0042828973 scopus 로고    scopus 로고
    • Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis
    • Shammas H.J., Shammas M.C., Garabet A., Kim J.H., Shammas A., and LaBree L. Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis. Am J Ophthalmol 136 (2003) 426-432
    • (2003) Am J Ophthalmol , vol.136 , pp. 426-432
    • Shammas, H.J.1    Shammas, M.C.2    Garabet, A.3    Kim, J.H.4    Shammas, A.5    LaBree, L.6
  • 7
    • 33646072742 scopus 로고    scopus 로고
    • Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation
    • Masket S., and Masket S.E. Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation. J Cataract Refract Surg 32 (2006) 430-434
    • (2006) J Cataract Refract Surg , vol.32 , pp. 430-434
    • Masket, S.1    Masket, S.E.2
  • 8
    • 0034764626 scopus 로고    scopus 로고
    • Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia; a standardized approach
    • Feiz V., Mannis M.J., Garcia-Ferrer F., Kandavel G., Darlington J.K., Kim E., Caspar J., Wang J.-L., and Wang W. Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia; a standardized approach. Cornea 20 (2001) 792-797
    • (2001) Cornea , vol.20 , pp. 792-797
    • Feiz, V.1    Mannis, M.J.2    Garcia-Ferrer, F.3    Kandavel, G.4    Darlington, J.K.5    Kim, E.6    Caspar, J.7    Wang, J.-L.8    Wang, W.9
  • 9
    • 33646073049 scopus 로고    scopus 로고
    • Accurate intraocular lens power calculation after myopic laser in situ keratomileusis, bypassing corneal power
    • Walter K.A., Gagnon M.R., Hoopes Jr. P.C., and Dickinson P.J. Accurate intraocular lens power calculation after myopic laser in situ keratomileusis, bypassing corneal power. J Cataract Refract Surg 32 (2006) 425-429
    • (2006) J Cataract Refract Surg , vol.32 , pp. 425-429
    • Walter, K.A.1    Gagnon, M.R.2    Hoopes Jr., P.C.3    Dickinson, P.J.4
  • 10
    • 0036205558 scopus 로고    scopus 로고
    • A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis
    • Hamed A.M., Wang L., Misra M., and Koch D.D. A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis. Ophthalmology 109 (2002) 651-658
    • (2002) Ophthalmology , vol.109 , pp. 651-658
    • Hamed, A.M.1    Wang, L.2    Misra, M.3    Koch, D.D.4
  • 12
    • 2642529695 scopus 로고    scopus 로고
    • Consideration of the posterior corneal curvature for assessment of corneal power after myopic LASIK
    • Accessed August 19, 2009
    • Langenbucher A., Torres F., Behrens A., Suarez E., Haigis W., and Seitz B. Consideration of the posterior corneal curvature for assessment of corneal power after myopic LASIK. Acta Ophthalmol Scand 82 (2004) 264-269. http://www3.interscience.wiley.com/cgi-bin/fulltext/118808619/PDFSTART Accessed August 19, 2009
    • (2004) Acta Ophthalmol Scand , vol.82 , pp. 264-269
    • Langenbucher, A.1    Torres, F.2    Behrens, A.3    Suarez, E.4    Haigis, W.5    Seitz, B.6
  • 14
    • 43049106183 scopus 로고    scopus 로고
    • Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery
    • Savini G., Barboni P., Profazio V., Zanini M., and Hoffer K.J. Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery. J Cataract Refract Surg 34 (2008) 809-813
    • (2008) J Cataract Refract Surg , vol.34 , pp. 809-813
    • Savini, G.1    Barboni, P.2    Profazio, V.3    Zanini, M.4    Hoffer, K.J.5
  • 15
    • 33751325375 scopus 로고    scopus 로고
    • Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula
    • Borasio E., Stevens J., and Smith G.T. Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula. J Cataract Refract Surg 32 (2006) 2004-2014
    • (2006) J Cataract Refract Surg , vol.32 , pp. 2004-2014
    • Borasio, E.1    Stevens, J.2    Smith, G.T.3
  • 16
    • 34247512562 scopus 로고    scopus 로고
    • Corneal changes after laser refractive surgery for myopia: comparison of Orbscan II and Pentacam findings
    • Hashemi H., and Mehravaran S. Corneal changes after laser refractive surgery for myopia: comparison of Orbscan II and Pentacam findings. J Cataract Refract Surg 33 (2007) 841-847
    • (2007) J Cataract Refract Surg , vol.33 , pp. 841-847
    • Hashemi, H.1    Mehravaran, S.2
  • 17
    • 33845738187 scopus 로고    scopus 로고
    • Determining corneal power using Orbscan II videokeratography for intraocular lens calculation after excimer laser surgery for myopia
    • Qazi M.A., Cua I.Y., Roberts C.J., and Pepose J.S. Determining corneal power using Orbscan II videokeratography for intraocular lens calculation after excimer laser surgery for myopia. J Cataract Refract Surg 33 (2007) 21-30
    • (2007) J Cataract Refract Surg , vol.33 , pp. 21-30
    • Qazi, M.A.1    Cua, I.Y.2    Roberts, C.J.3    Pepose, J.S.4
  • 18
    • 22644442254 scopus 로고    scopus 로고
    • Keratometry for intraocular lens power calculation using Orbscan II in eyes with laser in situ keratomileusis
    • Cheng A.C.K., and Lam D.S.C. Keratometry for intraocular lens power calculation using Orbscan II in eyes with laser in situ keratomileusis. J Refract Surg 21 (2005) 365-368
    • (2005) J Refract Surg , vol.21 , pp. 365-368
    • Cheng, A.C.K.1    Lam, D.S.C.2
  • 19
    • 0033485849 scopus 로고    scopus 로고
    • Accuracy of Orbscan total optical power maps in detecting refractive change after myopic laser in situ keratomileusis
    • Srivannaboon S., Reinstein D.Z., Sutton H.F.S., and Holland S.P. Accuracy of Orbscan total optical power maps in detecting refractive change after myopic laser in situ keratomileusis. J Cataract Refract Surg 25 (1999) 1596-1599
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1596-1599
    • Srivannaboon, S.1    Reinstein, D.Z.2    Sutton, H.F.S.3    Holland, S.P.4
  • 20
    • 33750440764 scopus 로고    scopus 로고
    • Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography
    • Tang M., Li Y., Avila M., and Huang D. Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography. J Cataract Refract Surg 32 (2006) 1843-1850
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1843-1850
    • Tang, M.1    Li, Y.2    Avila, M.3    Huang, D.4
  • 21
    • 4744341208 scopus 로고    scopus 로고
    • Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK
    • Wang L., Booth M.A., and Koch D.D. Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK. Ophthalmology 111 (2004) 1825-1831
    • (2004) Ophthalmology , vol.111 , pp. 1825-1831
    • Wang, L.1    Booth, M.A.2    Koch, D.D.3
  • 22
    • 33746315107 scopus 로고    scopus 로고
    • Intraocular lens power calculation after myopic refractive surgery; theoretical comparison of different methods
    • Savini G., Barboni P., and Zanini M. Intraocular lens power calculation after myopic refractive surgery; theoretical comparison of different methods. Ophthalmology 113 (2006) 1271-1282
    • (2006) Ophthalmology , vol.113 , pp. 1271-1282
    • Savini, G.1    Barboni, P.2    Zanini, M.3
  • 23
    • 45549094643 scopus 로고    scopus 로고
    • Intraocular lens power calculation after myopic laser in situ keratomileusis: estimating the corneal refractive power
    • Awwad S.T., Manasseh C., Bowman R.W., Cavanagh H.D., Verity S., Mootha V., and McCulley J.P. Intraocular lens power calculation after myopic laser in situ keratomileusis: estimating the corneal refractive power. J Cataract Refract Surg 34 (2008) 1070-1076
    • (2008) J Cataract Refract Surg , vol.34 , pp. 1070-1076
    • Awwad, S.T.1    Manasseh, C.2    Bowman, R.W.3    Cavanagh, H.D.4    Verity, S.5    Mootha, V.6    McCulley, J.P.7
  • 24
    • 57749191496 scopus 로고    scopus 로고
    • Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement
    • Kawamorita T., Uozato H., Kamiya K., Bax L., Tsutsui K., Aizawa D., and Shimizu K. Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement. J Cataract Refract Surg 35 (2009) 127-133
    • (2009) J Cataract Refract Surg , vol.35 , pp. 127-133
    • Kawamorita, T.1    Uozato, H.2    Kamiya, K.3    Bax, L.4    Tsutsui, K.5    Aizawa, D.6    Shimizu, K.7
  • 25
    • 33646035845 scopus 로고    scopus 로고
    • The Haigis formula
    • Shammas H.J. (Ed), Slack, Thorofare, NJ
    • Haigis W. The Haigis formula. In: Shammas H.J. (Ed). Intraocular Lens Power Calculations (2004), Slack, Thorofare, NJ 41-57
    • (2004) Intraocular Lens Power Calculations , pp. 41-57
    • Haigis, W.1
  • 26
    • 0027442385 scopus 로고
    • The HofferQ formula: a comparison of theoretic and regression formulas
    • errata 1994; 20:677
    • Hoffer K.J. The HofferQ formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg 19 (1993) 700-712 errata 1994; 20:677
    • (1993) J Cataract Refract Surg , vol.19 , pp. 700-712
    • Hoffer, K.J.1
  • 27
    • 33845800773 scopus 로고    scopus 로고
    • Errata in printed Hoffer Q formula
    • [letter] reply by KJ Hoffer, 2-3
    • Zuberbuhler B., and Morrell A.J. Errata in printed Hoffer Q formula. [letter]. J Cataract Refract Surg 33 (2007) 2 reply by KJ Hoffer, 2-3
    • (2007) J Cataract Refract Surg , vol.33 , pp. 2
    • Zuberbuhler, B.1    Morrell, A.J.2
  • 28
    • 0025315983 scopus 로고
    • Development of the SRK/T intraocular lens implant power calculation formula
    • correction, 528
    • Retzlaff J.A., Sanders D.R., and Kraff M.C. Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg 16 (1990) 333-340 correction, 528
    • (1990) J Cataract Refract Surg , vol.16 , pp. 333-340
    • Retzlaff, J.A.1    Sanders, D.R.2    Kraff, M.C.3
  • 29
    • 0347379977 scopus 로고    scopus 로고
    • Intraocular lens power calculation after corneal refractive surgery: double-K method
    • Aramberri J. Intraocular lens power calculation after corneal refractive surgery: double-K method. J Cataract Refract Surg 29 (2003) 2063-2068
    • (2003) J Cataract Refract Surg , vol.29 , pp. 2063-2068
    • Aramberri, J.1
  • 31
    • 0033497421 scopus 로고    scopus 로고
    • Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thickness
    • discussion by RK Maloney, 409-410
    • Wang Z., Chen J., and Yang B. Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thickness. Ophthalmology 106 (1999) 406-409 discussion by RK Maloney, 409-410
    • (1999) Ophthalmology , vol.106 , pp. 406-409
    • Wang, Z.1    Chen, J.2    Yang, B.3
  • 32
    • 0035086297 scopus 로고    scopus 로고
    • Posterior corneal curvature changes after myopic laser in situ keratomileusis
    • discussion by ED Donnenfeld, 673
    • Seitz B., Torres F., Langenbucher A., Behrens A., and Suárez E. Posterior corneal curvature changes after myopic laser in situ keratomileusis. Ophthalmology 108 (2001) 666-672 discussion by ED Donnenfeld, 673
    • (2001) Ophthalmology , vol.108 , pp. 666-672
    • Seitz, B.1    Torres, F.2    Langenbucher, A.3    Behrens, A.4    Suárez, E.5
  • 33
    • 0035150749 scopus 로고    scopus 로고
    • Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis
    • Baek T.M., Lee K.H., Kagaya F., Tomidokoro A., Amano S., and Oshika T. Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis. Ophthalmology 108 (2001) 317-320
    • (2001) Ophthalmology , vol.108 , pp. 317-320
    • Baek, T.M.1    Lee, K.H.2    Kagaya, F.3    Tomidokoro, A.4    Amano, S.5    Oshika, T.6
  • 34
    • 36448970833 scopus 로고    scopus 로고
    • Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry
    • Kim S.W., Byun Y.J., Kim E.K., and Kim T.-I. Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry. J Refract Surg 23 (2007) 888-894
    • (2007) J Refract Surg , vol.23 , pp. 888-894
    • Kim, S.W.1    Byun, Y.J.2    Kim, E.K.3    Kim, T.-I.4
  • 35
    • 0037373268 scopus 로고    scopus 로고
    • Reliability of pachymetric measurements using Orbscan after excimer refractive surgery
    • Prisant O., Calderon N., Chastang P., Gatinel D., and Hoang-Xuan T. Reliability of pachymetric measurements using Orbscan after excimer refractive surgery. Ophthalmology 110 (2003) 511-515
    • (2003) Ophthalmology , vol.110 , pp. 511-515
    • Prisant, O.1    Calderon, N.2    Chastang, P.3    Gatinel, D.4    Hoang-Xuan, T.5
  • 36
    • 37249088358 scopus 로고    scopus 로고
    • Comparison of corneal thickness measurements by ultrasound and Scheimpflug photography in eyes that have undergone laser in situ keratomileusis
    • Ciolino J.B., Khachikian S.S., and Belin M.W. Comparison of corneal thickness measurements by ultrasound and Scheimpflug photography in eyes that have undergone laser in situ keratomileusis. Am J Ophthalmol 145 (2008) 75-80
    • (2008) Am J Ophthalmol , vol.145 , pp. 75-80
    • Ciolino, J.B.1    Khachikian, S.S.2    Belin, M.W.3
  • 37
    • 33747364036 scopus 로고    scopus 로고
    • Changes in the posterior cornea after laser in situ keratomileusis and photorefractive keratectomy
    • Ciolino J.B., and Belin M.W. Changes in the posterior cornea after laser in situ keratomileusis and photorefractive keratectomy. J Cataract Refract Surg 32 (2006) 1426-1431
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1426-1431
    • Ciolino, J.B.1    Belin, M.W.2
  • 38
    • 34447644418 scopus 로고    scopus 로고
    • Long-term stability of the posterior cornea after laser in situ keratomileusis
    • Ciolino J.B., Khachikian S.S., Cortese M.J., and Belin M.W. Long-term stability of the posterior cornea after laser in situ keratomileusis. J Cataract Refract Surg 33 (2007) 1366-1370
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1366-1370
    • Ciolino, J.B.1    Khachikian, S.S.2    Cortese, M.J.3    Belin, M.W.4
  • 39
    • 42949161527 scopus 로고    scopus 로고
    • Changes in posterior corneal elevation after laser in situ keratomileusis enhancement
    • Vicente D., Clinch T.E., and Kang P.C. Changes in posterior corneal elevation after laser in situ keratomileusis enhancement. J Cataract Refract Surg 34 (2008) 785-788
    • (2008) J Cataract Refract Surg , vol.34 , pp. 785-788
    • Vicente, D.1    Clinch, T.E.2    Kang, P.C.3
  • 40
    • 33845792375 scopus 로고    scopus 로고
    • No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis
    • Shammas H.J., and Shammas M.C. No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis. J Cataract Refract Surg 33 (2007) 31-36
    • (2007) J Cataract Refract Surg , vol.33 , pp. 31-36
    • Shammas, H.J.1    Shammas, M.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.