메뉴 건너뛰기




Volumn 13, Issue 10, 1998, Pages 1091-1097

Thiolated Salmonella antibody immobilization onto the gold surface of piezoelectric quartz crystal

Author keywords

Antibody coated sensor; Quartz crystal microbalance; Sulfo LC SPDP; Thiolated antibody immobilization

Indexed keywords

ANTIBODIES; CELL IMMOBILIZATION; ELECTRODES; GOLD; PIEZOELECTRIC MATERIALS; QUARTZ APPLICATIONS; SULFUR COMPOUNDS;

EID: 0032213121     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(98)00067-0     Document Type: Article
Times cited : (148)

References (16)
  • 1
    • 0021876325 scopus 로고
    • Direct immunoassay of Salmonellae in foods and feeds
    • Anderson J.M., Hartman P.A. Direct immunoassay of Salmonellae in foods and feeds. Appl. Environ. Microbiol. 49:1985;1124-1127.
    • (1985) Appl. Environ. Microbiol. , vol.49 , pp. 1124-1127
    • Anderson, J.M.1    Hartman, P.A.2
  • 2
    • 33845184543 scopus 로고
    • Formation of monolayers by coadsorption of thiols on gold: Variation in the head group, tail group, and solvent
    • Bain C.D., Evall J., Whitesides G.M. Formation of monolayers by coadsorption of thiols on gold: Variation in the head group, tail group, and solvent. J. Am. Chem. Soc. 111:1989;7155-7164.
    • (1989) J. Am. Chem. Soc. , vol.111 , pp. 7155-7164
    • Bain, C.D.1    Evall, J.2    Whitesides, G.M.3
  • 3
    • 0024405872 scopus 로고
    • Continuous liquid-phase piezoelectric biosensor for kinetic immunoassays
    • Davis K.A., Leary T.R. Continuous liquid-phase piezoelectric biosensor for kinetic immunoassays. Anal. Chem. 61:1989;1227-1230.
    • (1989) Anal. Chem. , vol.61 , pp. 1227-1230
    • Davis, K.A.1    Leary, T.R.2
  • 4
    • 33845282373 scopus 로고
    • Blocking oriented monolayers of alkyl mercaptans on gold electrodes
    • Finklea H.O., Avery S., Lynch M., Furfsch T. Blocking oriented monolayers of alkyl mercaptans on gold electrodes. Langmuir. 3:1987;409-413.
    • (1987) Langmuir , vol.3 , pp. 409-413
    • Finklea, H.O.1    Avery, S.2    Lynch, M.3    Furfsch, T.4
  • 5
    • 0010327284 scopus 로고
    • Rapid microbiological testing kits and instruments
    • Giese J. Rapid microbiological testing kits and instruments. Food Technol. 49(7):1995;64-70.
    • (1995) Food Technol. , vol.49 , Issue.7 , pp. 64-70
    • Giese, J.1
  • 6
  • 9
    • 0021671232 scopus 로고
    • An improved enzyme immunoassay for the detection of Salmonella
    • Mattingly J.A., Gehle W.D. An improved enzyme immunoassay for the detection of Salmonella. J. Food Sci. 49:1984;807-809.
    • (1984) J. Food Sci. , vol.49 , pp. 807-809
    • Mattingly, J.A.1    Gehle, W.D.2
  • 10
    • 0001287053 scopus 로고
    • Piezoelectric immunosensor for the detection of Candida albicans microbes
    • Muramatsu H., Kajiwara K., Tamiya E., Karube I. Piezoelectric immunosensor for the detection of Candida albicans microbes. Anal. Chim. Acta. 188:1986;257-261.
    • (1986) Anal. Chim. Acta , vol.188 , pp. 257-261
    • Muramatsu, H.1    Kajiwara, K.2    Tamiya, E.3    Karube, I.4
  • 12
    • 33845281250 scopus 로고
    • Fundamental studies of the chemisorption of organosulfur compounds on Au(III). Implications for molecular self-assembly on gold surfaces
    • Nuzzo R.G., Zegarski B.R., Dubois L.H. Fundamental studies of the chemisorption of organosulfur compounds on Au(III). Implications for molecular self-assembly on gold surfaces. J. Am. Chem. Soc. 109:1987;733-740.
    • (1987) J. Am. Chem. Soc. , vol.109 , pp. 733-740
    • Nuzzo, R.G.1    Zegarski, B.R.2    Dubois, L.H.3
  • 13
    • 0026832837 scopus 로고
    • Development of a piezoelectric immunosensor for the detection of Enterobacteria
    • Plomer M., Guilbault G.G., Hock B. Development of a piezoelectric immunosensor for the detection of Enterobacteria. Enzyme Microb. Technol. 14:1992;230-235.
    • (1992) Enzyme Microb. Technol. , vol.14 , pp. 230-235
    • Plomer, M.1    Guilbault, G.G.2    Hock, B.3
  • 14
    • 0025404361 scopus 로고
    • Development of a piezoelectric immunosensor for the detection of Salmonella typhimurium
    • Prusak-Sochaczewski E., Luong J.H.T., Guilbault G.G. Development of a piezoelectric immunosensor for the detection of Salmonella typhimurium. Enzyme Microb. Technol. 12:1990;173-177.
    • (1990) Enzyme Microb. Technol. , vol.12 , pp. 173-177
    • Prusak-Sochaczewski, E.1    Luong, J.H.T.2    Guilbault, G.G.3
  • 15
    • 84951279351 scopus 로고
    • Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung
    • Sauerbrey G. Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung. Z. Phys. 155:1959;206-222.
    • (1959) Z. Phys. , vol.155 , pp. 206-222
    • Sauerbrey, G.1
  • 16
    • 0029808619 scopus 로고    scopus 로고
    • Activating piezoelectric crystal surface by silanization for microgravimetric immunobiosensor application
    • Suri C.R., Mishra G.C. Activating piezoelectric crystal surface by silanization for microgravimetric immunobiosensor application. Biosensors and Bioelectronics. 11:1996;1199-1205.
    • (1996) Biosensors and Bioelectronics , vol.11 , pp. 1199-1205
    • Suri, C.R.1    Mishra, G.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.