메뉴 건너뛰기




Volumn 49, Issue 12, 2009, Pages 2625-2630

Instituting a thawed plasma procedure: It just makes sense and saves cents

Author keywords

[No Author keywords available]

Indexed keywords

APHERESIS; ARTICLE; BLOOD BANK; BLOOD TRANSFUSION; COMPARATIVE STUDY; CONTROLLED STUDY; COST CONTROL; HEALTH CARE UTILIZATION; HUMAN; RISK; TIME SERIES ANALYSIS;

EID: 71849085796     PISSN: 00411132     EISSN: 15372995     Source Type: Journal    
DOI: 10.1111/j.1537-2995.2009.02342.x     Document Type: Article
Times cited : (32)

References (19)
  • 3
    • 0004149236 scopus 로고    scopus 로고
    • AABB. 17th ed. Bethesda (MD). American Association of Blood Banks
    • AABB. Standards for blood banks and transfusion services. 17th ed. Bethesda (MD) : American Association of Blood Banks 1996.
    • (1996) Standards for Blood Banks and Transfusion Services
  • 4
    • 41149097593 scopus 로고    scopus 로고
    • AABB. 25th ed. Bethesda (MD). American Association of Blood Banks
    • AABB. Standards for blood banks and transfusion services. 25th ed. Bethesda (MD) : American Association of Blood Banks 2008.
    • (2008) Standards for Blood Banks and Transfusion Services
  • 5
    • 38549122334 scopus 로고    scopus 로고
    • Plasma components: FFP, FP24, and thawed plasma
    • Eder AF, Sebok MA. Plasma components: FFP, FP24, and thawed plasma. Immunohematology 2007 23 : 150 7.
    • (2007) Immunohematology , vol.23 , pp. 150-157
    • Eder, A.F.1    Sebok, M.A.2
  • 6
    • 0034097236 scopus 로고    scopus 로고
    • Retention of coagulation factors in plasma frozen after extended holding at 1-6 degrees C
    • Smith JF, Ness PM, Moroff G, Luban NL. Retention of coagulation factors in plasma frozen after extended holding at 1-6 degrees C. Vox Sang. 2000 78 : 28 30.
    • (2000) Vox Sang , vol.78 , pp. 28-30
    • Smith, J.F.1    Ness, P.M.2    Moroff, G.3    Luban, N.L.4
  • 8
    • 23844453082 scopus 로고    scopus 로고
    • The quality of fresh-frozen plasma produced from whole blood stored at 4 degrees C overnight
    • Cardigan R, Lawrie AS, Mackie IJ, Williamson LM. The quality of fresh-frozen plasma produced from whole blood stored at 4 degrees C overnight. Transfusion 2005 45 : 1342 8.
    • (2005) Transfusion , vol.45 , pp. 1342-1348
    • Cardigan, R.1    Lawrie, A.S.2    MacKie, I.J.3    Williamson, L.M.4
  • 9
    • 55349114016 scopus 로고    scopus 로고
    • The effect of storing whole blood at 22 degrees C for up to 24 hours with and without rapid cooling on the quality of red cell concentrates and fresh-frozen plasma
    • Wilsher C, Garwood M, Sutherland J, Turner C, Cardigan R. The effect of storing whole blood at 22 degrees C for up to 24 hours with and without rapid cooling on the quality of red cell concentrates and fresh-frozen plasma. Transfusion 2008 48 : 2338 47.
    • (2008) Transfusion , vol.48 , pp. 2338-23347
    • Wilsher, C.1    Garwood, M.2    Sutherland, J.3    Turner, C.4    Cardigan, R.5
  • 10
    • 33746345852 scopus 로고    scopus 로고
    • Characterization of blood components prepared from whole-blood donations after a 24-hour hold with the platelet-rich plasma method
    • Thibault L, Beausejour A, de Grandmont MJ, Lemieux R, Leblanc JF. Characterization of blood components prepared from whole-blood donations after a 24-hour hold with the platelet-rich plasma method. Transfusion 2006 46 : 1292 9.
    • (2006) Transfusion , vol.46 , pp. 1292-1299
    • Thibault, L.1    Beausejour, A.2    De Grandmont, M.J.3    Lemieux, R.4    Leblanc, J.F.5
  • 12
    • 0035037923 scopus 로고    scopus 로고
    • Serial measurement of clotting factors in thawed plasma stored for 5 days
    • Downes KA, Wilson E, Yomtovian R, Sarode R. Serial measurement of clotting factors in thawed plasma stored for 5 days. Transfusion 2001 41 : 570.
    • (2001) Transfusion , vol.41 , pp. 570
    • Downes, K.A.1    Wilson, E.2    Yomtovian, R.3    Sarode, R.4
  • 13
    • 33845942215 scopus 로고    scopus 로고
    • Effects of thawing FFP at 37C and 45C and prolonged storage on the coagulation factors V, VII, and VIII
    • SUPPL
    • Monson J, Bracey A, Radovancevic R. Effects of thawing FFP at 37C and 45C and prolonged storage on the coagulation factors V, VII, and VIII. Transfusion 2004 44 Suppl : 64A.
    • (2004) Transfusion , vol.44
    • Monson, J.1    Bracey, A.2    Radovancevic, R.3
  • 14
    • 33845959477 scopus 로고    scopus 로고
    • Study of coagulation factor activities in apheresed thawed fresh frozen plasma at 1-6 degrees C for five days
    • Sidhu RS, Le T, Brimhall B, Thompson H. Study of coagulation factor activities in apheresed thawed fresh frozen plasma at 1-6 degrees C for five days. J Clin Apher 2006 21 : 224 6.
    • (2006) J Clin Apher , vol.21 , pp. 224-236
    • Sidhu, R.S.1    Le, T.2    Brimhall, B.3    Thompson, H.4
  • 15
    • 57249086396 scopus 로고    scopus 로고
    • Coagulation factor levels in plasma frozen within 24 hours of phlebotomy over 5 days of storage at 1-6 degrees C
    • Yazer MH, Cortese-Hassett A, Triulzi DJ. Coagulation factor levels in plasma frozen within 24 hours of phlebotomy over 5 days of storage at 1-6 degrees C. Transfusion 2008 48 : 2525 30.
    • (2008) Transfusion , vol.48 , pp. 2525-2530
    • Yazer, M.H.1    Cortese-Hassett, A.2    Triulzi, D.J.3
  • 17
    • 0242571144 scopus 로고    scopus 로고
    • American Association of Blood Banks, America's Blood Centers, American Red Cross. [cited 2009 Jan 12]. Available from: URL
    • Circular of information for use of human blood and blood components [homepage on the Internet]. American Association of Blood Banks, America's Blood Centers, American Red Cross 2002. [cited 2009 Jan 12]. Available from: URL: http://www.aabb.org/Documents/About-Blood/Circulars-of-Information/coi0702.pdf
    • (2002) Circular of Information for Use of Human Blood and Blood Components [homepage on the Internet]
  • 18
    • 84869673540 scopus 로고    scopus 로고
    • Code of Federal Regulations (4-1-2008 ed.) 21CFR601.22 The U.S. National Archives and Records Administration, College Park, MD. Available from: URL
    • Products in short supply; initial manufacturing at other than licensed location. In: Code of Federal Regulations (4-1-2008 ed.) 21CFR601.22 The U.S. National Archives and Records Administration, College Park, MD, 2008. Available from: URL: http://edocket.access.gpo.gov/cfr-2008/aprqtr/pdf/21cfr601.22.pdf
    • (2008) Products in Short Supply; Initial Manufacturing at other than Licensed Location


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.