메뉴 건너뛰기




Volumn 20, Issue 1, 2010, Pages 108-117

Intramuscular fine-wire electromyography during cycling: Repeatability, normalisation and a comparison to surface electromyography

Author keywords

Amplitude normalisation; Cycling; Electrode placement; Fine wire electromyography (EMG); Muscle recruitment; Repeatability

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; CYCLING; ELECTRODE; ELECTRODIAGNOSIS; ELECTROMYOGRAPHY; FEASIBILITY STUDY; FEMALE; FINE WIRE ELECTROMYOGRAPHY; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; KINEMATICS; LEG MUSCLE; MALE; MUSCLE CONTRACTION; MYOELECTRICITY; NORMAL HUMAN; PRIORITY JOURNAL; REPRODUCIBILITY; STATISTICAL ANALYSIS; TEST RETEST RELIABILITY;

EID: 71349086016     PISSN: 10506411     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jelekin.2008.11.013     Document Type: Article
Times cited : (53)

References (52)
  • 1
    • 0033838999 scopus 로고    scopus 로고
    • Comparison of across subject emg profiles using surface and multiple indwelling electrodes during gait
    • Bogey R.A., Perry J., Bontrager E.L., and Gronley J.K. Comparison of across subject emg profiles using surface and multiple indwelling electrodes during gait. J Electromyo Kinesiol 10 (2000) 255-259
    • (2000) J Electromyo Kinesiol , vol.10 , pp. 255-259
    • Bogey, R.A.1    Perry, J.2    Bontrager, E.L.3    Gronley, J.K.4
  • 2
    • 0037404604 scopus 로고    scopus 로고
    • Repeatability of wire and surface electrodes in gait
    • Bogey R.A., Carny K., and Mohammed O. Repeatability of wire and surface electrodes in gait. Am J Phys Med Rehabil 82 (2003) 338-344
    • (2003) Am J Phys Med Rehabil , vol.82 , pp. 338-344
    • Bogey, R.A.1    Carny, K.2    Mohammed, O.3
  • 3
    • 33750976379 scopus 로고    scopus 로고
    • Reliability of electromyographic normalization methods for evaluating the hip musculature
    • Bolgla L.A., and Uhl T.L. Reliability of electromyographic normalization methods for evaluating the hip musculature. J Electromyo Kinesiol 17 (2006) 102-111
    • (2006) J Electromyo Kinesiol , vol.17 , pp. 102-111
    • Bolgla, L.A.1    Uhl, T.L.2
  • 4
    • 0016199463 scopus 로고
    • Perceived exertion
    • Wilmore J.H. (Ed), Academic Press Inc., New York
    • Borg G., and Noblem B.J. Perceived exertion. In: Wilmore J.H. (Ed). Exercise and sports science reviews (1974), Academic Press Inc., New York 131-153
    • (1974) Exercise and sports science reviews , pp. 131-153
    • Borg, G.1    Noblem, B.J.2
  • 5
    • 0015444340 scopus 로고
    • Quantitative relationship between the surface emg and intramuscular electromyographic activity in voluntary movement
    • Bouisset S., and Matson M.S. Quantitative relationship between the surface emg and intramuscular electromyographic activity in voluntary movement. Am J Phys Med 51 (1972) 285-295
    • (1972) Am J Phys Med , vol.51 , pp. 285-295
    • Bouisset, S.1    Matson, M.S.2
  • 8
    • 34447550095 scopus 로고    scopus 로고
    • Leg muscle recruitment during cycling is less developed in triathletes than cyclists despite matched cycling training loads
    • Chapman, AR, Vicenzino B, Blanch P, Hodges PW. Leg muscle recruitment during cycling is less developed in triathletes than cyclists despite matched cycling training loads. Exp Brain Res 2007;181:503-11.
    • (2007) Exp Brain Res , vol.181 , pp. 503-511
    • Chapman, A.R.1    Vicenzino, B.2    Blanch, P.3    Hodges, P.W.4
  • 9
    • 42949117435 scopus 로고    scopus 로고
    • Patterns of leg muscle recruitment vary between trained and novice cyclists
    • Chapman AR, Vicenzino B, Blanch P, Hodges PW. Patterns of leg muscle recruitment vary between trained and novice cyclists. J Electromyo Kinesiol 2008b;18:359-71.
    • (2008) J Electromyo Kinesiol , vol.18 , pp. 359-371
    • Chapman, A.R.1    Vicenzino, B.2    Blanch, P.3    Hodges, P.W.4
  • 10
    • 39749173081 scopus 로고    scopus 로고
    • Is running less skilled in Triathletes than runners matched for training history?
    • Chapman A.R., Vicenzino B., Blanch P., and Hodges P.W. Is running less skilled in Triathletes than runners matched for training history?. Med Sci Sports Exerc 40 (2008) 557-565
    • (2008) Med Sci Sports Exerc , vol.40 , pp. 557-565
    • Chapman, A.R.1    Vicenzino, B.2    Blanch, P.3    Hodges, P.W.4
  • 11
    • 0036301218 scopus 로고    scopus 로고
    • Altered vastii recruitment when people with patellofemoral pain syndrome complete a postural task
    • Cowan S.M., Hodges P.W., Bennell K.L., and Crossley K.M. Altered vastii recruitment when people with patellofemoral pain syndrome complete a postural task. Arch Phys Med Rehabil 83 (2002) 989-995
    • (2002) Arch Phys Med Rehabil , vol.83 , pp. 989-995
    • Cowan, S.M.1    Hodges, P.W.2    Bennell, K.L.3    Crossley, K.M.4
  • 13
    • 0023939011 scopus 로고
    • Surface myoelectric signal cross-talk among muscles of the leg
    • De Luca C.J., and Merletti R. Surface myoelectric signal cross-talk among muscles of the leg. Electroencephalogr Clin Neurophysiol 69 (1988) 568-575
    • (1988) Electroencephalogr Clin Neurophysiol , vol.69 , pp. 568-575
    • De Luca, C.J.1    Merletti, R.2
  • 14
  • 16
    • 0025920047 scopus 로고
    • A comparison of the triceps surae and residual muscle moments at the ankle during cycling
    • Gregor R.J., Komi P.V., Browning R.C., and Jarvinen M. A comparison of the triceps surae and residual muscle moments at the ankle during cycling. J Biomech 24 (1991) 287-297
    • (1991) J Biomech , vol.24 , pp. 287-297
    • Gregor, R.J.1    Komi, P.V.2    Browning, R.C.3    Jarvinen, M.4
  • 18
    • 0030859787 scopus 로고    scopus 로고
    • Repeated measures of adult normal walking using a video tracking system
    • Growney E., Meglan D., Johnson M., Cahalan T., and An K.N. Repeated measures of adult normal walking using a video tracking system. Gait Posture 6 (1997) 147-162
    • (1997) Gait Posture , vol.6 , pp. 147-162
    • Growney, E.1    Meglan, D.2    Johnson, M.3    Cahalan, T.4    An, K.N.5
  • 19
    • 0033813270 scopus 로고    scopus 로고
    • Development of recommendations for SEMG sensors and sensor placement procedures
    • Hermens H.J., Freriks B., Disselhorst-Klug C., and Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyo Kinesiol 10 (2000) 361-374
    • (2000) J Electromyo Kinesiol , vol.10 , pp. 361-374
    • Hermens, H.J.1    Freriks, B.2    Disselhorst-Klug, C.3    Rau, G.4
  • 20
    • 0036334996 scopus 로고    scopus 로고
    • Delayed onset of quadriceps activity and altered knee joint kinematics during stair stepping in individuals with knee osteoarthritis
    • Hinman R.S., Bennell K.L., Metcalf B.R., and Crossley K.M. Delayed onset of quadriceps activity and altered knee joint kinematics during stair stepping in individuals with knee osteoarthritis. Arch Phys Med Rehabil 83 8 (2002) 1080-1086
    • (2002) Arch Phys Med Rehabil , vol.83 , Issue.8 , pp. 1080-1086
    • Hinman, R.S.1    Bennell, K.L.2    Metcalf, B.R.3    Crossley, K.M.4
  • 21
    • 0034255932 scopus 로고    scopus 로고
    • Pitfalls of intramuscular electromyographic recordings from the human costal diaphragm
    • Hodges P.W., and Gandevia S.C. Pitfalls of intramuscular electromyographic recordings from the human costal diaphragm. Clin Neurophysiol 111 (2000) 1420-1424
    • (2000) Clin Neurophysiol , vol.111 , pp. 1420-1424
    • Hodges, P.W.1    Gandevia, S.C.2
  • 22
    • 0031043828 scopus 로고    scopus 로고
    • Validation of a technique for accurate fine-wire electrode placement into posterior gluteus medius using real-time ultrasound guidance
    • Hodges P.W., Kippers V., and Richardson C.A. Validation of a technique for accurate fine-wire electrode placement into posterior gluteus medius using real-time ultrasound guidance. Electromyogr Clin Neurophysiol 37 (1997) 39-47
    • (1997) Electromyogr Clin Neurophysiol , vol.37 , pp. 39-47
    • Hodges, P.W.1    Kippers, V.2    Richardson, C.A.3
  • 24
    • 2142695520 scopus 로고
    • Insertion of fine-wire electrodes does not alter temporal emg patterns in normal adults
    • Jacobson W.C., Gabel R.H., and Brand R.A. Insertion of fine-wire electrodes does not alter temporal emg patterns in normal adults. Gait Posture 3 (1995) 59-63
    • (1995) Gait Posture , vol.3 , pp. 59-63
    • Jacobson, W.C.1    Gabel, R.H.2    Brand, R.A.3
  • 25
    • 71349085326 scopus 로고
    • Electrode problem in electromyographic kinesiology
    • Johnson B. Electrode problem in electromyographic kinesiology. Electromyography 1 Suppl. 1 (1968) 27-35
    • (1968) Electromyography , vol.1 , Issue.SUPPL. 1 , pp. 27-35
    • Johnson, B.1
  • 26
    • 0342793762 scopus 로고
    • Wire electrodes in electromyographic kinesiology
    • Wartenweiler J., Jokl E., and Hebbelinch G. (Eds), University Park Press, Baltimore
    • Jonsson B. Wire electrodes in electromyographic kinesiology. In: Wartenweiler J., Jokl E., and Hebbelinch G. (Eds). Biomechanics i (1968), University Park Press, Baltimore 123-127
    • (1968) Biomechanics i , pp. 123-127
    • Jonsson, B.1
  • 27
    • 0000581550 scopus 로고
    • Reproducibility problems when using wire electrodes
    • Desmedt J.E. (Ed)
    • Jonsson B., and Komi P.V. Reproducibility problems when using wire electrodes. In: Desmedt J.E. (Ed). New dev emg clin neurophysiol (1973) 540-546
    • (1973) New dev emg clin neurophysiol , pp. 540-546
    • Jonsson, B.1    Komi, P.V.2
  • 28
    • 0014241216 scopus 로고
    • Reproducibility in kinesiologic emg investigations with intramuscular electrodes
    • Jonsson B., and Reichmann S. Reproducibility in kinesiologic emg investigations with intramuscular electrodes. Acta Morphol Neerlando-Scand 7 (1968) 73-90
    • (1968) Acta Morphol Neerlando-Scand , vol.7 , pp. 73-90
    • Jonsson, B.1    Reichmann, S.2
  • 29
    • 0014517249 scopus 로고
    • Displacement and deformation of wire electrodes in electromyography. A roentgenologic study
    • Jonsson B., and Reichmann S. Displacement and deformation of wire electrodes in electromyography. A roentgenologic study. Electromyography 9 (1969) 201-211
    • (1969) Electromyography , vol.9 , pp. 201-211
    • Jonsson, B.1    Reichmann, S.2
  • 30
    • 0022929716 scopus 로고
    • Analysis of emg measurement during bicycle pedalling
    • Jorge M., and Hull M.L. Analysis of emg measurement during bicycle pedalling. J Biomech 19 (1986) 683-694
    • (1986) J Biomech , vol.19 , pp. 683-694
    • Jorge, M.1    Hull, M.L.2
  • 31
    • 0022360685 scopus 로고
    • Repeatability of phasic muscle activity: performance of surface and intramuscular wire electrodes in gait analysis
    • Kadaba M.P., Wootten M.E., Gainey J., and Cochran G.V. Repeatability of phasic muscle activity: performance of surface and intramuscular wire electrodes in gait analysis. J Orthop Res 3 (1985) 350-359
    • (1985) J Orthop Res , vol.3 , pp. 350-359
    • Kadaba, M.P.1    Wootten, M.E.2    Gainey, J.3    Cochran, G.V.4
  • 32
    • 0025915494 scopus 로고
    • Valgus deformities of the feet and characteristics of gait in patients who have rheumatoid arthritis
    • Keenan M.A., Peabody T.D., Gronley J.K., and Perry J. Valgus deformities of the feet and characteristics of gait in patients who have rheumatoid arthritis. J Bone Joint Surg Am 73 (1991) 237-247
    • (1991) J Bone Joint Surg Am , vol.73 , pp. 237-247
    • Keenan, M.A.1    Peabody, T.D.2    Gronley, J.K.3    Perry, J.4
  • 33
    • 0022525611 scopus 로고
    • "Cross-talk" In electromyograms: contamination of emgs recorded with bipolar fine-wire electrodes by volume conducted myoelectric activity from distant sources
    • Mangun G.R., Mulkey R.M., Young B.L., and Goslow Jr. G.E. "Cross-talk" In electromyograms: contamination of emgs recorded with bipolar fine-wire electrodes by volume conducted myoelectric activity from distant sources. Electromyography Clin Neurophysiol 26 (1986) 443-461
    • (1986) Electromyography Clin Neurophysiol , vol.26 , pp. 443-461
    • Mangun, G.R.1    Mulkey, R.M.2    Young, B.L.3    Goslow Jr., G.E.4
  • 34
    • 71349085980 scopus 로고
    • Doctoral Thesis. The University of Queensland, Department of Anatomical Science, Brisbane, Australia;
    • McLean B. Anatomical and biomechanical correlates of performance in cycling. Doctoral Thesis. The University of Queensland, Department of Anatomical Science, Brisbane, Australia; 1990.
    • (1990) Anatomical and biomechanical correlates of performance in cycling
    • McLean, B.1
  • 35
    • 0029803185 scopus 로고    scopus 로고
    • Myoelectric and mechanical manifestations of muscle fatigue in voluntary contractions
    • Merletti R., and Roy S. Myoelectric and mechanical manifestations of muscle fatigue in voluntary contractions. J Orthop Sports Phys Ther 24 (1996) 342-353
    • (1996) J Orthop Sports Phys Ther , vol.24 , pp. 342-353
    • Merletti, R.1    Roy, S.2
  • 36
    • 0025641868 scopus 로고
    • Myoelectric manifestations of fatigue in voluntary and electrically elicited contractions
    • Merletti R., Knaflitz M., and De Luca C.J. Myoelectric manifestations of fatigue in voluntary and electrically elicited contractions. J Appl Physiol 69 (1990) 1810-1820
    • (1990) J Appl Physiol , vol.69 , pp. 1810-1820
    • Merletti, R.1    Knaflitz, M.2    De Luca, C.J.3
  • 37
    • 0034485771 scopus 로고    scopus 로고
    • The triathlon: acute and overuse injuries
    • Migliorini S. The triathlon: acute and overuse injuries. J Sports Traumatol Related Res 22 (2000) 186-195
    • (2000) J Sports Traumatol Related Res , vol.22 , pp. 186-195
    • Migliorini, S.1
  • 38
    • 5644297315 scopus 로고    scopus 로고
    • Neuromuscular and biomechanical coupling in human cycling: modulation of cutaneous reflex responses to sural nerve stimulation
    • Mileva K., and Turner D. Neuromuscular and biomechanical coupling in human cycling: modulation of cutaneous reflex responses to sural nerve stimulation. Exp Brain Res 158 (2004) 450-464
    • (2004) Exp Brain Res , vol.158 , pp. 450-464
    • Mileva, K.1    Turner, D.2
  • 39
  • 40
    • 0032191630 scopus 로고    scopus 로고
    • A study of the reproducibility of three different normalisation methods in intramuscular dual fine wire electromyography of the shoulder
    • Morris A.D., Kemp G.J., Lees A., and Frostick S.P. A study of the reproducibility of three different normalisation methods in intramuscular dual fine wire electromyography of the shoulder. J Electromyo Kinesiol 8 (1998) 317-322
    • (1998) J Electromyo Kinesiol , vol.8 , pp. 317-322
    • Morris, A.D.1    Kemp, G.J.2    Lees, A.3    Frostick, S.P.4
  • 41
    • 0031259617 scopus 로고    scopus 로고
    • The effect of pedaling rate on coordination in cycling
    • Neptune R.R., Kautz S.A., and Hull M.L. The effect of pedaling rate on coordination in cycling. J Biomech 30 (1997) 1051-1058
    • (1997) J Biomech , vol.30 , pp. 1051-1058
    • Neptune, R.R.1    Kautz, S.A.2    Hull, M.L.3
  • 44
    • 0242593720 scopus 로고    scopus 로고
    • Changes in reciprocal inhibition across the ankle joint with changes in external load and pedaling rate during bicycling
    • Pyndt H.S., Laursen M., and Nielsen J.B. Changes in reciprocal inhibition across the ankle joint with changes in external load and pedaling rate during bicycling. J Neurophysiol 90 (2003) 3168-3177
    • (2003) J Neurophysiol , vol.90 , pp. 3168-3177
    • Pyndt, H.S.1    Laursen, M.2    Nielsen, J.B.3
  • 46
    • 1242298663 scopus 로고    scopus 로고
    • A method for positioning electrodes during surface emg recordings in lower limb muscles
    • Rainoldi A., Melchiorri G., and Caruso I. A method for positioning electrodes during surface emg recordings in lower limb muscles. J Neurosci Meth 134 (2004) 37-43
    • (2004) J Neurosci Meth , vol.134 , pp. 37-43
    • Rainoldi, A.1    Melchiorri, G.2    Caruso, I.3
  • 47
    • 0032898287 scopus 로고    scopus 로고
    • Three-dimensional kinematics of the forefoot, rearfoot, and leg without the function of tibialis posterior in comparison with normals during stance phase of walking
    • Rattanaprasert U., Smith R., Sullivaqb M., and Gilleard W. Three-dimensional kinematics of the forefoot, rearfoot, and leg without the function of tibialis posterior in comparison with normals during stance phase of walking. Clin Biomech 14 (1999) 14-23
    • (1999) Clin Biomech , vol.14 , pp. 14-23
    • Rattanaprasert, U.1    Smith, R.2    Sullivaqb, M.3    Gilleard, W.4
  • 48
    • 0022995453 scopus 로고
    • Effects of electrode location on myoelectric conduction velocity and median frequency estimates
    • Roy S.H., De Luca C.J., and Schneider J. Effects of electrode location on myoelectric conduction velocity and median frequency estimates. J Appl Physiol 61 (1986) 1510-1517
    • (1986) J Appl Physiol , vol.61 , pp. 1510-1517
    • Roy, S.H.1    De Luca, C.J.2    Schneider, J.3
  • 49
    • 0026774019 scopus 로고
    • Emg profiles of lower-extremity muscles during cycling at constant workload and cadence
    • Ryan M.M., and Gregor R.J. Emg profiles of lower-extremity muscles during cycling at constant workload and cadence. J Electromyo Kinesiol 2 (1992) 69-80
    • (1992) J Electromyo Kinesiol , vol.2 , pp. 69-80
    • Ryan, M.M.1    Gregor, R.J.2
  • 51
    • 33748757927 scopus 로고    scopus 로고
    • Comparison of foot kinematics between subjects with posterior tibialis tendon dysfunction and healthy controls
    • Tome J., Nawoczenski D., Flemister A., and Houck J. Comparison of foot kinematics between subjects with posterior tibialis tendon dysfunction and healthy controls. J Orthop Sport Phys Ther 36 9 (2006) 635-644
    • (2006) J Orthop Sport Phys Ther , vol.36 , Issue.9 , pp. 635-644
    • Tome, J.1    Nawoczenski, D.2    Flemister, A.3    Houck, J.4
  • 52
    • 0027194924 scopus 로고
    • Effects of external load and abduction angle on emg level of shoulder muscles during isometric action
    • Van Woensel W., and Arwert H. Effects of external load and abduction angle on emg level of shoulder muscles during isometric action. Electromyogr Clin Neurophysiol 33 (1993) 185-191
    • (1993) Electromyogr Clin Neurophysiol , vol.33 , pp. 185-191
    • Van Woensel, W.1    Arwert, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.