메뉴 건너뛰기




Volumn 134, Issue 1, 2004, Pages 37-43

A method for positioning electrodes during surface EMG recordings in lower limb muscles

Author keywords

Electrode positioning; Electromyography; EMG variables; Innervation zone; Lower limb muscles; Standardization

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; ELECTRODE; ELECTROMYOGRAM; FOLLOW UP; GASTROCNEMIUS MUSCLE; GLUTEUS MAXIMUS MUSCLE; HEALTH STATUS; HUMAN; HUMAN EXPERIMENT; LEG MUSCLE; MALE; MUSCLE FIBER MEMBRANE CONDUCTANCE; NORMAL HUMAN; PERONEUS MUSCLE; PRIORITY JOURNAL; QUALITY CONTROL; RECORDING; RECTUS FEMORIS MUSCLE; SEMITENDINOUS MUSCLE; SKELETAL MUSCLE; SOLEUS MUSCLE; STANDARDIZATION; SURFACE PROPERTY; TENSOR FASCIA LATA MUSCLE; TIBIALIS ANTERIOR MUSCLE; VASTUS LATERALIS MUSCLE; VASTUS MEDIALIS MUSCLE; VELOCITY;

EID: 1242298663     PISSN: 01650270     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jneumeth.2003.10.014     Document Type: Article
Times cited : (458)

References (32)
  • 1
    • 0035524244 scopus 로고    scopus 로고
    • Muscle activation intervals and EMG envelope in clinical gait analysis
    • Benedetti M. Muscle activation intervals and EMG envelope in clinical gait analysis. IEEE Eng. Med. Biol. Mag. 20(6):2001;33-34.
    • (2001) IEEE Eng. Med. Biol. Mag. , vol.20 , Issue.6 , pp. 33-34
    • Benedetti, M.1
  • 2
    • 0031028476 scopus 로고    scopus 로고
    • Lower limb skeletal muscle function after 6 wk of bed rest
    • Berg H.E., Larsson L., Tesch P.A. Lower limb skeletal muscle function after 6 wk of bed rest. J. Appl. Physiol. 82(1):1997;182-188.
    • (1997) J. Appl. Physiol. , vol.82 , Issue.1 , pp. 182-188
    • Berg, H.E.1    Larsson, L.2    Tesch, P.A.3
  • 3
    • 0037388888 scopus 로고    scopus 로고
    • Can continuous physical training counteract aging effect on myoelectric fatigue? a surface electromyography study application
    • Casale R., Rainoldi A., Nilsson J., Bellotti P. Can continuous physical training counteract aging effect on myoelectric fatigue? A surface electromyography study application. Arch. Phys. Med. Rehabil. 84(4):2003;513-517.
    • (2003) Arch. Phys. Med. Rehabil. , vol.84 , Issue.4 , pp. 513-517
    • Casale, R.1    Rainoldi, A.2    Nilsson, J.3    Bellotti, P.4
  • 4
    • 0027393824 scopus 로고
    • Use of the surface EMG signal for performance evaluation of back muscles
    • De Luca C.J. Use of the surface EMG signal for performance evaluation of back muscles. Muscle Nerve. 16(2):1993a;210-216.
    • (1993) Muscle Nerve , vol.16 , Issue.2 , pp. 210-216
    • De Luca, C.J.1
  • 5
    • 0030973129 scopus 로고
    • The use of surface electromyography in biomechanics
    • De Luca C.J. The use of surface electromyography in biomechanics. J. Appl. Biomech. 13:1993b;135-163.
    • (1993) J. Appl. Biomech. , vol.13 , pp. 135-163
    • De Luca, C.J.1
  • 6
    • 0021600921 scopus 로고
    • Myoelectric manifestations of localized muscular fatigue in humans.
    • De Luca CJ. Myoelectric manifestations of localized muscular fatigue in humans. Crit Rev Biomed Eng 1984;251-79.
    • (1984) Crit Rev Biomed Eng , pp. 251-279
    • De Luca, C.J.1
  • 7
    • 0028724382 scopus 로고
    • Neuromuscular adaptation to actual and simulated weightlessness
    • Bonting SL (Ed.), Greenwich, CT: JAI Press
    • Edgerton VR, Roy RR. Neuromuscular adaptation to actual and simulated weightlessness. In: Bonting SL (Ed.), Advances in space biology and medicine, vol. 4. Greenwich, CT: JAI Press; 1994. p. 33-67.
    • (1994) Advances in Space Biology and Medicine , vol.4 , pp. 33-67
    • Edgerton, V.R.1    Roy, R.R.2
  • 8
    • 0036153336 scopus 로고    scopus 로고
    • Location of innervation zones of sternocleidomastoid and scalene muscles: A basis for clinical and research electromyography applications
    • Falla D., Dall'Alba P., Rainoldi A., Merletti R., Jull G. Location of innervation zones of sternocleidomastoid and scalene muscles: a basis for clinical and research electromyography applications. Clin. Neurophysiol. 113(1):2002;57-63.
    • (2002) Clin. Neurophysiol. , vol.113 , Issue.1 , pp. 57-63
    • Falla, D.1    Dall'Alba, P.2    Rainoldi, A.3    Merletti, R.4    Jull, G.5
  • 10
    • 0025915061 scopus 로고
    • Dependence of the mean power frequency of the electromyogram on muscle force and fibre type
    • Gerdle B., Henriksson-Larsen K., Lorentzon R., Wretling M.L. Dependence of the mean power frequency of the electromyogram on muscle force and fibre type. Acta Physiol. Scand. 142(4):1991;457-465.
    • (1991) Acta Physiol. Scand. , vol.142 , Issue.4 , pp. 457-465
    • Gerdle, B.1    Henriksson-Larsen, K.2    Lorentzon, R.3    Wretling, M.L.4
  • 11
    • 0033813270 scopus 로고    scopus 로고
    • Development of recommendations for SEMG sensors and sensor placement procedures
    • Hermens H.J., Freriks B., Disselhorst-Klug C., Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J. Electromyogr. Kinesiol. 10(5):2000;361-374.
    • (2000) J. Electromyogr. Kinesiol. , vol.10 , Issue.5 , pp. 361-374
    • Hermens, H.J.1    Freriks, B.2    Disselhorst-Klug, C.3    Rau, G.4
  • 12
    • 0030946683 scopus 로고    scopus 로고
    • Feedforward contraction of transversus abdominis is not influenced by the direction of arm movement
    • Hodges P.W., Richardson C.A. Feedforward contraction of transversus abdominis is not influenced by the direction of arm movement. Exp. Brain Res. 114:1997;362-370.
    • (1997) Exp. Brain Res. , vol.114 , pp. 362-370
    • Hodges, P.W.1    Richardson, C.A.2
  • 13
    • 0015957374 scopus 로고
    • Fast and slow contraction times associated with fast and slow spike conduction of skeletal muscle fibres in normal subjects and in spastic hemiparesis
    • Hopf H.C., Herbort R.L., Gnass M., Gunther H., Lowitzsch K. Fast and slow contraction times associated with fast and slow spike conduction of skeletal muscle fibres in normal subjects and in spastic hemiparesis. Z. Neurol. 206(3):1974;193-202.
    • (1974) Z. Neurol. , vol.206 , Issue.3 , pp. 193-202
    • Hopf, H.C.1    Herbort, R.L.2    Gnass, M.3    Gunther, H.4    Lowitzsch, K.5
  • 15
    • 0032033365 scopus 로고    scopus 로고
    • The influence of muscle fiber size and type distribution on electromyographic measures of back muscle fatigability
    • Mannion A.F., Dumas G.A., Stevenson J.M., Cooper R.G. The influence of muscle fiber size and type distribution on electromyographic measures of back muscle fatigability. Spine. 23(5):1998;576-584.
    • (1998) Spine , vol.23 , Issue.5 , pp. 576-584
    • Mannion, A.F.1    Dumas, G.A.2    Stevenson, J.M.3    Cooper, R.G.4
  • 16
    • 0021892188 scopus 로고
    • The position of innervation zones in the biceps brachii investigated by surface electromyography
    • Masuda T., Miyano H., Sadoyama T. The position of innervation zones in the biceps brachii investigated by surface electromyography. IEEE Trans. Biomed. Eng. 32(1):1985a;36-42.
    • (1985) IEEE Trans. Biomed. Eng. , vol.32 , Issue.1 , pp. 36-42
    • Masuda, T.1    Miyano, H.2    Sadoyama, T.3
  • 17
    • 0021828128 scopus 로고
    • A surface electrode array for detecting action potential trains of single motor units
    • Masuda T., Miyano H., Sadoyama T. A surface electrode array for detecting action potential trains of single motor units. Electroencephalogr. Clin. Neurophysiol. 60(5):1985b;435-443.
    • (1985) Electroencephalogr. Clin. Neurophysiol. , vol.60 , Issue.5 , pp. 435-443
    • Masuda, T.1    Miyano, H.2    Sadoyama, T.3
  • 19
    • 0025641868 scopus 로고
    • Myoelectric manifestations of fatigue in voluntary and electrically elicited contractions
    • Merletti R., Knaflitz M., De Luca C.J. Myoelectric manifestations of fatigue in voluntary and electrically elicited contractions. J. Appl. Physiol. 69(5):1990;1810-1820.
    • (1990) J. Appl. Physiol. , vol.69 , Issue.5 , pp. 1810-1820
    • Merletti, R.1    Knaflitz, M.2    De Luca, C.J.3
  • 20
    • 0033255264 scopus 로고    scopus 로고
    • Non-invasive assessment of motor unit properties with linear electrode arrays
    • Merletti R., Farina D., Granata A. Non-invasive assessment of motor unit properties with linear electrode arrays. Electroenceph. Clin. Neurophysiol. Suppl 50:1999;293-300.
    • (1999) Electroenceph. Clin. Neurophysiol. , vol.50 , pp. 293-300
    • Merletti, R.1    Farina, D.2    Granata, A.3
  • 21
    • 0036136615 scopus 로고    scopus 로고
    • Effect of age on muscle functions investigated with surface electromyography
    • Merletti R., Farina D., Gazzoni M., Schieroni M.P. Effect of age on muscle functions investigated with surface electromyography. Muscle Nerve. 25(1):2002;65-76.
    • (2002) Muscle Nerve , vol.25 , Issue.1 , pp. 65-76
    • Merletti, R.1    Farina, D.2    Gazzoni, M.3    Schieroni, M.P.4
  • 22
    • 12244299982 scopus 로고    scopus 로고
    • Electrode placement in dynamic surface EMG: The effect of the innervation zone in ESMAC&SIAMOC Joint Congress, Rome, 12-14 October
    • Merletti R., Merlo A., Rainoldi A. Electrode placement in dynamic surface EMG: the effect of the innervation zone in ESMAC&SIAMOC Joint Congress, Rome, 12-14 October. Gait Posture. 14(2):2001a;120.
    • (2001) Gait Posture , vol.14 , Issue.2 , pp. 120
    • Merletti, R.1    Merlo, A.2    Rainoldi, A.3
  • 23
    • 0035234413 scopus 로고    scopus 로고
    • Surface EMG for non-invasive muscle characterization
    • Merletti R., Rainoldi A., Farina D. Surface EMG for non-invasive muscle characterization. Exerc. Sport Sci. Rev. 29(1):2001b;20-25.
    • (2001) Exerc. Sport Sci. Rev. , vol.29 , Issue.1 , pp. 20-25
    • Merletti, R.1    Rainoldi, A.2    Farina, D.3
  • 27
    • 0022995453 scopus 로고
    • Effects of electrode location on myoelectric conduction velocity and median frequency estimates
    • Roy S.H., De Luca C.J., Schneider J. Effects of electrode location on myoelectric conduction velocity and median frequency estimates. J. Appl. Physiol. 61(4):1986;1510-1517.
    • (1986) J. Appl. Physiol. , vol.61 , Issue.4 , pp. 1510-1517
    • Roy, S.H.1    De Luca, C.J.2    Schneider, J.3
  • 28
    • 0022093412 scopus 로고
    • Optimal conditions for the measurement of muscle fiber conduction velocity using surface electrode arrays
    • Sadoyama T., Masuda T., Miyano T. Optimal conditions for the measurement of muscle fiber conduction velocity using surface electrode arrays. Med. Biol. Eng. Comput. 23:1985;339-342.
    • (1985) Med. Biol. Eng. Comput. , vol.23 , pp. 339-342
    • Sadoyama, T.1    Masuda, T.2    Miyano, T.3
  • 30
    • 0034990012 scopus 로고    scopus 로고
    • The evolution of clinical gait analysis. Part 1. Kinesiological EMG
    • Sutherland D. The evolution of clinical gait analysis. Part 1. Kinesiological EMG. Gait Posture. 14(1):2001;61-70.
    • (2001) Gait Posture , vol.14 , Issue.1 , pp. 61-70
    • Sutherland, D.1
  • 31
    • 0014786680 scopus 로고
    • Effects of skin electrode position on averaged electromyographic potentials
    • Zuniga E.N., Truong X.T., Simons D.G. Effects of skin electrode position on averaged electromyographic potentials. Arch. Phys. Med. Rehabil. 51(5):1970;264-272.
    • (1970) Arch. Phys. Med. Rehabil. , vol.51 , Issue.5 , pp. 264-272
    • Zuniga, E.N.1    Truong, X.T.2    Simons, D.G.3
  • 32
    • 0033817510 scopus 로고    scopus 로고
    • Recent progress in the diagnostic use of surface EMG for neurological diseases
    • Zwarts M.J., Drost G., Stegeman D.F. Recent progress in the diagnostic use of surface EMG for neurological diseases. J. Electromyogr. Kinesiol. 10(5):2000;287-291.
    • (2000) J. Electromyogr. Kinesiol. , vol.10 , Issue.5 , pp. 287-291
    • Zwarts, M.J.1    Drost, G.2    Stegeman, D.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.