메뉴 건너뛰기




Volumn , Issue , 2006, Pages 127-136

Optical coherence tomography

Author keywords

[No Author keywords available]

Indexed keywords


EID: 71049185448     PISSN: None     EISSN: None     Source Type: Book    
DOI: None     Document Type: Chapter
Times cited : (1)

References (43)
  • 1
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science 1991; 254:1178.
    • (1991) Science , vol.254 , pp. 1178
    • Huang, D.1    Swanson, E.A.2    Lin, C.P.3
  • 2
    • 0033327503 scopus 로고    scopus 로고
    • Optical coherence tomography (OCT): A review
    • Schmitt JM. Optical coherence tomography (OCT): a review. IEEE 1999; 5:1205.
    • (1999) IEEE , vol.5 , pp. 1205
    • Schmitt, J.M.1
  • 4
    • 0030760309 scopus 로고    scopus 로고
    • In vivo endoscopic optical biopsy with optical coherence tomography
    • Tearney GJ, Brezinski ME, Bouma BE, et al. In vivo endoscopic optical biopsy with optical coherence tomography. Science 1997; 276:2037.
    • (1997) Science , vol.276 , pp. 2037
    • Tearney, G.J.1    Brezinski, M.E.2    Bouma, B.E.3
  • 5
    • 69949102288 scopus 로고
    • Determination of the refractive index of highly scattering human tissue by optical coherence tomography
    • Tearney GT, Brezinski ME, Southem JF, et al. Determination of the refractive index of highly scattering human tissue by optical coherence tomography. Opt Lett 1995; 20:2258.
    • (1995) Opt Lett , vol.20 , pp. 2258
    • Tearney, G.T.1    Brezinski, M.E.2    Southem, J.F.3
  • 6
    • 1642633824 scopus 로고    scopus 로고
    • Effect of target biological tissue and choice of light source on penetration depth and resolution in optical coherence tomography
    • Sainter AW, King TA, Dickinson MR. Effect of target biological tissue and choice of light source on penetration depth and resolution in optical coherence tomography. J Biomed Opt 2004; 9:193.
    • (2004) J Biomed Opt , vol.9 , pp. 193
    • Sainter, A.W.1    King, T.A.2    Dickinson, M.R.3
  • 7
    • 0035297583 scopus 로고    scopus 로고
    • Optical properties of human skin in the near infrared wavelength range of 1000-2200 nm
    • Troy TL, Thennadil SN. Optical properties of human skin in the near infrared wavelength range of 1000-2200 nm. J Biomed Opt 2001; 6:167.
    • (2001) J Biomed Opt , vol.6 , pp. 167
    • Troy, T.L.1    Thennadil, S.N.2
  • 8
    • 0242322532 scopus 로고    scopus 로고
    • Optical coherence tomography for ultrahigh resolution in vivo imaging
    • Fujimoto JG. Optical coherence tomography for ultrahigh resolution in vivo imaging. Nat Biotechnol 2003; 21:1361.
    • (2003) Nat Biotechnol , vol.21 , pp. 1361
    • Fujimoto, J.G.1
  • 9
    • 1642602745 scopus 로고    scopus 로고
    • Ultrahigh-resolution optical coherence tomography
    • Drexler W. Ultrahigh-resolution optical coherence tomography. J Biomed Opt 2004; 9:47.
    • (2004) J Biomed Opt , vol.9 , pp. 47
    • Drexler, W.1
  • 10
    • 11144355809 scopus 로고    scopus 로고
    • Advances in broad bandwidth light sources for ultrahigh resolution optical coherence tomography
    • Unterhuber A, Povazay B, Bizheva K, et al. Advances in broad bandwidth light sources for ultrahigh resolution optical coherence tomography. Phys Med Biol 2004; 49:1235.
    • (2004) Phys Med Biol , vol.49 , pp. 1235
    • Unterhuber, A.1    Povazay, B.2    Bizheva, K.3
  • 11
    • 0033624456 scopus 로고    scopus 로고
    • Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography
    • Knüttel A, Boehlau-Godau M. Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography. J Biomed Opt 2000; 5:83.
    • (2000) J Biomed Opt , vol.5 , pp. 83
    • Knüttel, A.1    Boehlau-Godau, M.2
  • 12
    • 2442717902 scopus 로고    scopus 로고
    • New method for evaluation of in vivo scattering and refractive index properties obtained with optical coherence tomography
    • Knüttel A, Bonev S, Knaak W. New method for evaluation of in vivo scattering and refractive index properties obtained with optical coherence tomography. J Biomed Opt 2004; 9:265.
    • (2004) J Biomed Opt , vol.9 , pp. 265
    • Knüttel, A.1    Bonev, S.2    Knaak, W.3
  • 13
  • 14
    • 0037280575 scopus 로고    scopus 로고
    • Optical coherence and Doppler tomography for monitoring tissue changes induced by laser thermal therapy-an in vivo feasibility study
    • Yang VXD, Pekar J, Lo SSW, et al. Optical coherence and Doppler tomography for monitoring tissue changes induced by laser thermal therapy-an in vivo feasibility study. Rev Sci Instrum 2003; 74:437.
    • (2003) Rev Sci Instrum , vol.74 , pp. 437
    • Yang, V.X.D.1    Pekar, J.2    Lo, S.S.W.3
  • 15
    • 0009363792 scopus 로고    scopus 로고
    • Three-dimensional reconstruction of blood vessels from in vivo color Doppler optical coherence tomography images
    • Kehlet Barton J, Izatt JA, Kulkarni MD, et al. Three-dimensional reconstruction of blood vessels from in vivo color Doppler optical coherence tomography images. Dermatology 1999; 198:355.
    • (1999) Dermatology , vol.198 , pp. 355
    • Kehlet Barton, J.1    Izatt, J.A.2    Kulkarni, M.D.3
  • 16
    • 10744222069 scopus 로고    scopus 로고
    • In vivo Doppler optical coherence tomography of mucocutaneous telangiectases in hereditary hemorrhagic telangiectasia
    • Tang SJ, Gordon ML, Yang VX, et al. In vivo Doppler optical coherence tomography of mucocutaneous telangiectases in hereditary hemorrhagic telangiectasia. Gastrointest Endosc 2003; 58:591.
    • (2003) Gastrointest Endosc , vol.58 , pp. 591
    • Tang, S.J.1    Gordon, M.L.2    Yang, V.X.3
  • 17
    • 4143143251 scopus 로고    scopus 로고
    • Advances in optical coherence tomography imaging for dermatology
    • Pierce MC, Strasswimmer J, Hyle Park B, et al. Advances in optical coherence tomography imaging for dermatology. J Invest Dermatol 2004; 123:458.
    • (2004) J Invest Dermatol , vol.123 , pp. 458
    • Pierce, M.C.1    Strasswimmer, J.2    Hyle Park, B.3
  • 18
    • 2442646774 scopus 로고    scopus 로고
    • Polarization-sensitive optical coherence tomography of invasive basal cell carcinoma
    • Strasswimmer J, Pierce MC, Park BH, et al. Polarization-sensitive optical coherence tomography of invasive basal cell carcinoma. J Biomed Opt 2004; 9:292.
    • (2004) J Biomed Opt , vol.9 , pp. 292
    • Strasswimmer, J.1    Pierce, M.C.2    Park, B.H.3
  • 19
    • 2442690677 scopus 로고    scopus 로고
    • Birefringence measurements in human skin using polarization-sensitive optical coherence tomography
    • Pierce MC, Strasswimmer H, Hyle Park B, et al. Birefringence measurements in human skin using polarization-sensitive optical coherence tomography. J Biomed Opt 2004; 9:287.
    • (2004) J Biomed Opt , vol.9 , pp. 287
    • Pierce, M.C.1    Strasswimmer, H.2    Hyle Park, B.3
  • 21
    • 0000439050 scopus 로고    scopus 로고
    • Imaging thermally damaged tissue by polarization sensitive optical coherence tomography
    • de Boer JF, Srinivas SM, Malekafzali A, et al. Imaging thermally damaged tissue by polarization sensitive optical coherence tomography. Opt Express 1998; 3:212.
    • (1998) Opt Express , vol.3 , pp. 212
    • de Boer, J.F.1    Srinivas, S.M.2    Malekafzali, A.3
  • 22
    • 1642633821 scopus 로고    scopus 로고
    • Determination of burn depth by polarizationsensitive optical coherence tomography
    • Srinivas SM, de Boer JF, Park BH, et al. Determination of burn depth by polarizationsensitive optical coherence tomography. J Biomed Opt 2004; 9:207.
    • (2004) J Biomed Opt , vol.9 , pp. 207
    • Srinivas, S.M.1    de Boer, J.F.2    Park, B.H.3
  • 23
    • 6444234850 scopus 로고    scopus 로고
    • Polarization-resolved second-harmonic generation optical coherence tomography in collagen
    • Applegate BE, Yang C, Rollins AM, Izatt JA. Polarization-resolved second-harmonic generation optical coherence tomography in collagen. Opt Lett 2004; 29:2252.
    • (2004) Opt Lett , vol.29 , pp. 2252
    • Applegate, B.E.1    Yang, C.2    Rollins, A.M.3    Izatt, J.A.4
  • 24
    • 0010749679 scopus 로고    scopus 로고
    • OCT elastography: Imaging microscopic deformation and strain of tissue
    • Schmitt JM. OCT elastography: imaging microscopic deformation and strain of tissue. Opt Express 1998; 3:199.
    • (1998) Opt Express , vol.3 , pp. 199
    • Schmitt, J.M.1
  • 25
    • 10444241923 scopus 로고    scopus 로고
    • Optical coherence tomography of skin for measurement of epidermal thickness by shapelet-based image analysis
    • Weissman J, Hancewicz T, Kaplan P. Optical coherence tomography of skin for measurement of epidermal thickness by shapelet-based image analysis. Opt Express 2004; 12:5,760.
    • (2004) Opt Express , vol.12
    • Weissman, J.1    Hancewicz, T.2    Kaplan, P.3
  • 26
    • 27744492183 scopus 로고    scopus 로고
    • Comparison of histometric data obtained by optical coherence tomography and routine histology
    • Gambichler T, Boms S, Stücker M, et al. Comparison of histometric data obtained by optical coherence tomography and routine histology. J Biomed Opt 2005; 10:44,008.
    • (2005) J Biomed Opt , vol.10
    • Gambichler, T.1    Boms, S.2    Stücker, M.3
  • 27
    • 2442667968 scopus 로고    scopus 로고
    • Characterization of age-related effects in human skin: A comparative study that applies confocal laser scanning microscopy and optical coherence tomography
    • Neerken S, Lucassen GW, Bisschop BA, et al. Characterization of age-related effects in human skin: a comparative study that applies confocal laser scanning microscopy and optical coherence tomography. J Biomed Opt 2004; 9:274.
    • (2004) J Biomed Opt , vol.9 , pp. 274
    • Neerken, S.1    Lucassen, G.W.2    Bisschop, B.A.3
  • 31
    • 0033983388 scopus 로고    scopus 로고
    • In vivo optical coherence tomography imaging of human skin: Norm and pathology
    • Gladova ND, Petrova GA, Nikulin NK, et al. In vivo optical coherence tomography imaging of human skin: norm and pathology. Skin Res Technol 2000; 6:6.
    • (2000) Skin Res Technol , vol.6 , pp. 6
    • Gladova, N.D.1    Petrova, G.A.2    Nikulin, N.K.3
  • 32
    • 1542507092 scopus 로고    scopus 로고
    • Changes in function and morphology of normal human skin: Evaluation using optical coherence tomography
    • Welzel J, Reinhardt C, Lankenau E, et al. Changes in function and morphology of normal human skin: evaluation using optical coherence tomography. Br J Dermatol 2004; 150:220.
    • (2004) Br J Dermatol , vol.150 , pp. 220
    • Welzel, J.1    Reinhardt, C.2    Lankenau, E.3
  • 33
    • 0035188381 scopus 로고    scopus 로고
    • Optical coherence tomography in dermatology: A review
    • Welzel J. Optical coherence tomography in dermatology: a review. Skin Res Technol 2001; 7:1.
    • (2001) Skin Res Technol , vol.7 , pp. 1
    • Welzel, J.1
  • 34
    • 0038050999 scopus 로고    scopus 로고
    • Optical coherence tomography in contact dermatitis and psoriasis
    • Welzel J, Bruhns M, Wolff HH. Optical coherence tomography in contact dermatitis and psoriasis. Arch Dermatol Res 2003; 295:50.
    • (2003) Arch Dermatol Res , vol.295 , pp. 50
    • Welzel, J.1    Bruhns, M.2    Wolff, H.H.3
  • 35
    • 2442705677 scopus 로고    scopus 로고
    • Imaging wound healing using optical coherence tomography and multiphoton microscopy in an in vitro skin equivalent tissue model
    • Yeh AT, Kao B, Jung WG, et al. Imaging wound healing using optical coherence tomography and multiphoton microscopy in an in vitro skin equivalent tissue model. J Biomed Opt 2004; 9:248.
    • (2004) J Biomed Opt , vol.9 , pp. 248
    • Yeh, A.T.1    Kao, B.2    Jung, W.G.3
  • 36
    • 4043079174 scopus 로고    scopus 로고
    • Histomorphologic correlation with routine histology and optical coherence tomography
    • Bechara FG, Gambichler T, Stücker M, et al. Histomorphologic correlation with routine histology and optical coherence tomography. Skin Res Technol 2004; 10:169.
    • (2004) Skin Res Technol , vol.10 , pp. 169
    • Bechara, F.G.1    Gambichler, T.2    Stücker, M.3
  • 37
    • 0032969447 scopus 로고    scopus 로고
    • Use of an agent to reduce scattering in skin
    • Vargas G, Chan EK, Barton JK, et al. Use of an agent to reduce scattering in skin. Lasers Surg Med 1999; 24:133.
    • (1999) Lasers Surg Med , vol.24 , pp. 133
    • Vargas, G.1    Chan, E.K.2    Barton, J.K.3
  • 38
    • 0037928110 scopus 로고    scopus 로고
    • Morphological changes in blood vessels produced by hyperosmotic agents and measured by optical coherence tomography
    • Vargas G, Readinger A, Dozier SS, Welsh AJ. Morphological changes in blood vessels produced by hyperosmotic agents and measured by optical coherence tomography. Photochem Photobiol 2003; 77:541.
    • (2003) Photochem Photobiol , vol.77 , pp. 541
    • Vargas, G.1    Readinger, A.2    Dozier, S.S.3    Welsh, A.J.4
  • 39
    • 19944432509 scopus 로고    scopus 로고
    • UVA1 and UVB irradiated skin investigated by optical coherence tomography in vivo: A preliminary study
    • Gambichler T, Künzlberger B, Paech V, et al. UVA1 and UVB irradiated skin investigated by optical coherence tomography in vivo: a preliminary study. Clin Exp Dermatol 2005; 30:79.
    • (2005) Clin Exp Dermatol , vol.30 , pp. 79
    • Gambichler, T.1    Künzlberger, B.2    Paech, V.3
  • 40
    • 27744596406 scopus 로고    scopus 로고
    • Skin alterations following ultraviolet radiation investigated by optical coherence tomography
    • Gambichler T, Boms S, Stücker M, et al. Skin alterations following ultraviolet radiation investigated by optical coherence tomography. Arch Dermatol Res 2005; 297:218.
    • (2005) Arch Dermatol Res , vol.297 , pp. 218
    • Gambichler, T.1    Boms, S.2    Stücker, M.3
  • 42
    • 0038029572 scopus 로고    scopus 로고
    • Compact, broad-bandwidth fiber laser for sub-2-microm axial resolution optical coherence tomography in the 1300-nm wavelength region
    • Bizheva K, Povazay B, Hermann B, et al. Compact, broad-bandwidth fiber laser for sub-2-microm axial resolution optical coherence tomography in the 1300-nm wavelength region. Opt Lett 2003; 28:707.
    • (2003) Opt Lett , vol.28 , pp. 707
    • Bizheva, K.1    Povazay, B.2    Hermann, B.3
  • 43
    • 10944229859 scopus 로고    scopus 로고
    • Real-time, ultrahigh resolution optical coherence tomography with an all-fiber, femtosecond fiber laser continuum at 1.5 microm
    • Nishizawa N, Chen Y, Hsiung P, et al. Real-time, ultrahigh resolution optical coherence tomography with an all-fiber, femtosecond fiber laser continuum at 1.5 microm. Opt Lett 2004; 29:2,846.
    • (2004) Opt Lett , vol.29
    • Nishizawa, N.1    Chen, Y.2    Hsiung, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.