메뉴 건너뛰기




Volumn 49, Issue 2, 2010, Pages 1326-1339

Diffusion orientation transform revisited

Author keywords

Diffusion orientation transform (DOT); Diffusion spectrum imaging (DSI); High angular resolution diffusion imaging (HARDI); Orientational distribution function (ODF); Q ball imaging (QBI)

Indexed keywords

ANALYTIC METHOD; ARTICLE; ARTIFACT; CONTROLLED STUDY; DIFFUSION; DIFFUSION WEIGHTED IMAGING; HYPOTHESIS; IMAGE RECONSTRUCTION; IMAGING; MATHEMATICAL ANALYSIS; MEASUREMENT ERROR; METHODOLOGY; PHANTOM; PRIORITY JOURNAL; PROBABILITY; SAMPLING; SIGNAL PROCESSING; VALIDITY;

EID: 70949090831     PISSN: 10538119     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2009.09.067     Document Type: Article
Times cited : (31)

References (43)
  • 1
    • 26444574077 scopus 로고    scopus 로고
    • Multiple-fiber reconstruction algorithms for diffusion MRI
    • Alexander D.C. Multiple-fiber reconstruction algorithms for diffusion MRI. Ann. N.Y. Acad. Sci. 1064 (2005) 113-133
    • (2005) Ann. N.Y. Acad. Sci. , vol.1064 , pp. 113-133
    • Alexander, D.C.1
  • 2
    • 27644461834 scopus 로고    scopus 로고
    • Measurement of fiber orientation distributions using high angular resolution diffusion imaging
    • Anderson A.W. Measurement of fiber orientation distributions using high angular resolution diffusion imaging. Magn. Reson. Med. 54 (2005) 1194-1206
    • (2005) Magn. Reson. Med. , vol.54 , pp. 1194-1206
    • Anderson, A.W.1
  • 3
    • 47549090792 scopus 로고    scopus 로고
    • Subwavelength displacement of the far-field image of a radiating dipole
    • Arnoldus H.F., Li X., and Shu J. Subwavelength displacement of the far-field image of a radiating dipole. Opt. Lett. 33 (2008) 1446-1448
    • (2008) Opt. Lett. , vol.33 , pp. 1446-1448
    • Arnoldus, H.F.1    Li, X.2    Shu, J.3
  • 4
    • 22044439126 scopus 로고    scopus 로고
    • Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
    • Assaf Y., and Basser P.J. Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain. Neuroimage 27 (2005) 48-58
    • (2005) Neuroimage , vol.27 , pp. 48-58
    • Assaf, Y.1    Basser, P.J.2
  • 5
    • 0028154030 scopus 로고
    • MR diffusion tensor spectroscopy and imaging
    • Basser P.J., Mattiello J., and LeBihan D. MR diffusion tensor spectroscopy and imaging. Biophys. J. 66 (1994) 259-267
    • (1994) Biophys. J. , vol.66 , pp. 259-267
    • Basser, P.J.1    Mattiello, J.2    LeBihan, D.3
  • 7
    • 33751096767 scopus 로고    scopus 로고
    • Probabilistic diffusion tractography with multiple fibre orientations: what can we gain?
    • Behrens T.E., Berg H.J., Jbabdi S., Rushworth M.F., and Woolrich M.W. Probabilistic diffusion tractography with multiple fibre orientations: what can we gain?. Neuroimage 34 (2007) 144-155
    • (2007) Neuroimage , vol.34 , pp. 144-155
    • Behrens, T.E.1    Berg, H.J.2    Jbabdi, S.3    Rushworth, M.F.4    Woolrich, M.W.5
  • 9
    • 47849127692 scopus 로고    scopus 로고
    • Antenna-mediated back-scattering efficiency in infrared near-field microscopy
    • Brehm M., Schliesser A., Cajko F., Tsukerman I., and Keilmann F. Antenna-mediated back-scattering efficiency in infrared near-field microscopy. Opt. Express 16 (2008) 11203-11215
    • (2008) Opt. Express , vol.16 , pp. 11203-11215
    • Brehm, M.1    Schliesser, A.2    Cajko, F.3    Tsukerman, I.4    Keilmann, F.5
  • 12
    • 67049167419 scopus 로고    scopus 로고
    • Mathematical description of q-space in spherical coordinates: exact q-Ball imaging
    • 2009 Jun
    • Canales-Rodríguez E.J., Melie-García L., and Iturria-Medina Y. Mathematical description of q-space in spherical coordinates: exact q-Ball imaging. Magn. Reson. Med. 61 6 (2009) 1350-1367 2009 Jun
    • (2009) Magn. Reson. Med. , vol.61 , Issue.6 , pp. 1350-1367
    • Canales-Rodríguez, E.J.1    Melie-García, L.2    Iturria-Medina, Y.3
  • 14
    • 33746752673 scopus 로고    scopus 로고
    • Apparent diffusion coefficients from high angular resolution diffusion imaging: estimation and applications
    • Descoteaux M., Angelino E., Fitzgibbons S., and Deriche R. Apparent diffusion coefficients from high angular resolution diffusion imaging: estimation and applications. Magn. Reson. Med. 56 (2006) 395-410
    • (2006) Magn. Reson. Med. , vol.56 , pp. 395-410
    • Descoteaux, M.1    Angelino, E.2    Fitzgibbons, S.3    Deriche, R.4
  • 15
    • 0035007493 scopus 로고    scopus 로고
    • Anisotropy in high angular resolution diffusion-weighted MRI
    • Frank L.R. Anisotropy in high angular resolution diffusion-weighted MRI. Magn. Reson. Med. 45 (2001) 935-939
    • (2001) Magn. Reson. Med. , vol.45 , pp. 935-939
    • Frank, L.R.1
  • 16
    • 0036263865 scopus 로고    scopus 로고
    • Characterization of anisotropy in high angular resolution diffusion-weighted MRI
    • Frank L.R. Characterization of anisotropy in high angular resolution diffusion-weighted MRI. Magn. Reson. Med. 47 (2002) 1083-1099
    • (2002) Magn. Reson. Med. , vol.47 , pp. 1083-1099
    • Frank, L.R.1
  • 17
    • 33746768810 scopus 로고    scopus 로고
    • Mapping complex myoarchitecture in the bovine tongue with diffusion-spectrum magnetic resonance imaging
    • Gilbert R.J., Magnusson L.H., Napadow V.J., Benner T., Wang R., and Wedeen V.J. Mapping complex myoarchitecture in the bovine tongue with diffusion-spectrum magnetic resonance imaging. Biophys. J. 91 (2006) 1014-1022
    • (2006) Biophys. J. , vol.91 , pp. 1014-1022
    • Gilbert, R.J.1    Magnusson, L.H.2    Napadow, V.J.3    Benner, T.4    Wang, R.5    Wedeen, V.J.6
  • 18
    • 0021895466 scopus 로고
    • The admittance of the squid giant axon at radio frequencies and its relation to membrane structure
    • Mar
    • Haydon D.A., and Urban BW. The admittance of the squid giant axon at radio frequencies and its relation to membrane structure. J. Physiol. 360 (1985) 275-291 Mar
    • (1985) J. Physiol. , vol.360 , pp. 275-291
    • Haydon, D.A.1    Urban, BW.2
  • 19
    • 0037372228 scopus 로고    scopus 로고
    • Comparison of the return-to-the-origin probability and the apparent diffusion coefficient of water as indicators of necrosis in RIF-1 tumors
    • Helmer K.G., Meiler M.R., Sotak C.H., and Petruccelli J.D. Comparison of the return-to-the-origin probability and the apparent diffusion coefficient of water as indicators of necrosis in RIF-1 tumors. Magn. Reson. Med. 49 (2003) 468-478
    • (2003) Magn. Reson. Med. , vol.49 , pp. 468-478
    • Helmer, K.G.1    Meiler, M.R.2    Sotak, C.H.3    Petruccelli, J.D.4
  • 20
    • 33745699926 scopus 로고    scopus 로고
    • Q-ball reconstruction of multimodal fiber orientations using the spherical harmonic basis
    • Hess C.P., Mukherjee P., Han E.T., Xu D., and Vigneron D.B. Q-ball reconstruction of multimodal fiber orientations using the spherical harmonic basis. Magn. Reson. Med. 56 (2006) 104-117
    • (2006) Magn. Reson. Med. , vol.56 , pp. 104-117
    • Hess, C.P.1    Mukherjee, P.2    Han, E.T.3    Xu, D.4    Vigneron, D.B.5
  • 21
    • 28544450535 scopus 로고    scopus 로고
    • Inference of multiple fiber orientations in high angular resolution diffusion imaging
    • Hosey T., Williams G., and Ansorge R. Inference of multiple fiber orientations in high angular resolution diffusion imaging. Magn. Reson. Med. 54 (2005) 1480-1489
    • (2005) Magn. Reson. Med. , vol.54 , pp. 1480-1489
    • Hosey, T.1    Williams, G.2    Ansorge, R.3
  • 23
    • 0142125688 scopus 로고    scopus 로고
    • Persistent angular structure: new insights from diffusion MRI data
    • Jansons K.M., and Alexander D.C. Persistent angular structure: new insights from diffusion MRI data. Inverse Problems 19 (2003) 1031-1046
    • (2003) Inverse Problems , vol.19 , pp. 1031-1046
    • Jansons, K.M.1    Alexander, D.C.2
  • 24
    • 0032835247 scopus 로고    scopus 로고
    • Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
    • Jones D.K., Horsfield M.A., and Simmons A. Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging. Magn. Reson. Med. 42 (1999) 515-525
    • (1999) Magn. Reson. Med. , vol.42 , pp. 515-525
    • Jones, D.K.1    Horsfield, M.A.2    Simmons, A.3
  • 25
    • 0038042125 scopus 로고    scopus 로고
    • Looking into the functional architecture of the brain with diffusion MRI
    • LeBihan D. Looking into the functional architecture of the brain with diffusion MRI. Nat. Rev. Neurosci. 4 (2003) 469-480
    • (2003) Nat. Rev. Neurosci. , vol.4 , pp. 469-480
    • LeBihan, D.1
  • 26
    • 0043172480 scopus 로고    scopus 로고
    • Validation of diffusion spectrum magnetic resonance imaging with manganese-enhanced rat optic tracts and ex vivo phantoms
    • Lin C.P., Wedeen V.J., Chen J.H., Yao C., and Tseng W.Y. Validation of diffusion spectrum magnetic resonance imaging with manganese-enhanced rat optic tracts and ex vivo phantoms. Neuroimage 19 (2003) 482-495
    • (2003) Neuroimage , vol.19 , pp. 482-495
    • Lin, C.P.1    Wedeen, V.J.2    Chen, J.H.3    Yao, C.4    Tseng, W.Y.5
  • 27
    • 2342542443 scopus 로고    scopus 로고
    • Characterizing non-Gaussian diffusion by using generalized diffusion tensors
    • Liu C., Bammer R., Acar B., and Moseley M.E. Characterizing non-Gaussian diffusion by using generalized diffusion tensors. Magn. Reson. Med. 51 (2004) 924-937
    • (2004) Magn. Reson. Med. , vol.51 , pp. 924-937
    • Liu, C.1    Bammer, R.2    Acar, B.3    Moseley, M.E.4
  • 28
    • 22744450648 scopus 로고    scopus 로고
    • Limitations of apparent diffusion coefficient-based models in characterizing non-gaussian diffusion
    • Liu C., Bammer R., and Moseley M.E. Limitations of apparent diffusion coefficient-based models in characterizing non-gaussian diffusion. Magn. Reson. Med. 54 (2005) 419-428
    • (2005) Magn. Reson. Med. , vol.54 , pp. 419-428
    • Liu, C.1    Bammer, R.2    Moseley, M.E.3
  • 31
    • 0002611222 scopus 로고
    • Pulsed-field-gradient NMR measurements of restricted diffusion and the return-to-the-origin probability
    • Mitra P.P., Latour L.L., Kleinberg R.L., and Sotak C.H. Pulsed-field-gradient NMR measurements of restricted diffusion and the return-to-the-origin probability. J. Magn. Reson., Series A 114 (1995) 47-58
    • (1995) J. Magn. Reson., Series A , vol.114 , pp. 47-58
    • Mitra, P.P.1    Latour, L.L.2    Kleinberg, R.L.3    Sotak, C.H.4
  • 32
    • 33744928872 scopus 로고    scopus 로고
    • Resolution of complex tissue microarchitecture using the diffusion orientation transform (DOT)
    • Ozarslan E., Shepherd T.M., Vemuri B.C., Blackband S.J., and Mareci T.H. Resolution of complex tissue microarchitecture using the diffusion orientation transform (DOT). Neuroimage 31 (2006) 1086-1103
    • (2006) Neuroimage , vol.31 , pp. 1086-1103
    • Ozarslan, E.1    Shepherd, T.M.2    Vemuri, B.C.3    Blackband, S.J.4    Mareci, T.H.5
  • 33
    • 0043212183 scopus 로고    scopus 로고
    • A framework for a streamline-based probabilistic index of connectivity (PICo) using a structural interpretation of MRI diffusion measurements
    • Parker G.J., Haroon H.A., and Wheeler-Kingshott C.A. A framework for a streamline-based probabilistic index of connectivity (PICo) using a structural interpretation of MRI diffusion measurements. J. Magn. Reson. Imaging 18 (2003) 242-254
    • (2003) J. Magn. Reson. Imaging , vol.18 , pp. 242-254
    • Parker, G.J.1    Haroon, H.A.2    Wheeler-Kingshott, C.A.3
  • 34
  • 35
    • 0023774277 scopus 로고
    • Changes of the ratio between myelin thickness and axon diameter in human developing sural, femoral, ulnar, facial, and trochlear nerves
    • Schröder J.M., Bohl J., and von Bardeleben U. Changes of the ratio between myelin thickness and axon diameter in human developing sural, femoral, ulnar, facial, and trochlear nerves. Acta Neuropathol. 76 5 (1988) 471-483
    • (1988) Acta Neuropathol. , vol.76 , Issue.5 , pp. 471-483
    • Schröder, J.M.1    Bohl, J.2    von Bardeleben, U.3
  • 36
    • 0001862719 scopus 로고
    • Restricted diffusion in cylindrical geometry
    • Soderman O., and Jonsson B. Restricted diffusion in cylindrical geometry. J. Magn. Reson., Series A 117 (1995) 94-97
    • (1995) J. Magn. Reson., Series A , vol.117 , pp. 94-97
    • Soderman, O.1    Jonsson, B.2
  • 38
    • 34147121196 scopus 로고    scopus 로고
    • Robust determination of the fibre orientation distribution in diffusion MRI: non-negativity constrained super-resolved spherical deconvolution
    • Tournier J.D., Calamante F., and Connelly A. Robust determination of the fibre orientation distribution in diffusion MRI: non-negativity constrained super-resolved spherical deconvolution. Neuroimage 35 (2007) 1459-1472
    • (2007) Neuroimage , vol.35 , pp. 1459-1472
    • Tournier, J.D.1    Calamante, F.2    Connelly, A.3
  • 39
    • 47949112827 scopus 로고    scopus 로고
    • Resolving crossing fibres using constrained spherical deconvolution: validation using diffusion-weighted imaging phantom data
    • Tournier J.D., Yeh C.H., Calamante F., Cho K.H., Connelly A., and Lin C.P. Resolving crossing fibres using constrained spherical deconvolution: validation using diffusion-weighted imaging phantom data. Neuroimage 42 (2008) 617-625
    • (2008) Neuroimage , vol.42 , pp. 617-625
    • Tournier, J.D.1    Yeh, C.H.2    Calamante, F.3    Cho, K.H.4    Connelly, A.5    Lin, C.P.6
  • 40
    • 10044249029 scopus 로고    scopus 로고
    • Q-ball imaging
    • Tuch D.S. Q-ball imaging. Magn. Reson. Med. 52 (2004) 1358-1372
    • (2004) Magn. Reson. Med. , vol.52 , pp. 1358-1372
    • Tuch, D.S.1
  • 41
  • 42
    • 28444477694 scopus 로고    scopus 로고
    • Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
    • Wedeen V.J., Hagmann P., Tseng W.Y., Reese T.G., and Weisskoff R.M. Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging. Magn. Reson. Med. 54 (2005) 1377-1386
    • (2005) Magn. Reson. Med. , vol.54 , pp. 1377-1386
    • Wedeen, V.J.1    Hagmann, P.2    Tseng, W.Y.3    Reese, T.G.4    Weisskoff, R.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.