메뉴 건너뛰기




Volumn 9, Issue 6, 2009, Pages 4483-4502

An overview of recent strategies in pathogen sensing

Author keywords

Lab on a chip; Microfabrication; Microfluidics; Nanofabrication; Pathogen

Indexed keywords

CONVENTIONAL METHODS; DELETERIOUS EFFECTS; DETECTION AND IDENTIFICATIONS; PATHOGENIC BACTERIUM; REPRODUCTIVE CYCLE; SAMPLE PREPARATION; SENSING MODALITIES; WATER TREATMENT FACILITIES;

EID: 70849103161     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s90604483     Document Type: Review
Times cited : (107)

References (88)
  • 1
    • 0036096446 scopus 로고    scopus 로고
    • Detection of infectious and toxigenic bacteria
    • Deisingh, A.K.; Thompson, M. Detection of infectious and toxigenic bacteria. Analyst 2002, 127, 567-581.
    • (2002) Analyst , vol.127 , pp. 567-581
    • Deisingh, A.K.1    Thompson, M.2
  • 3
    • 43049108745 scopus 로고    scopus 로고
    • Trends and opportunities in food pathogen detection
    • Nugen, S.R.; Baeumner, A.J. Trends and opportunities in food pathogen detection. Anal. Bioanal. Chem. 2008, 391, 451-454.
    • (2008) Anal. Bioanal. Chem , vol.391 , pp. 451-454
    • Nugen, S.R.1    Baeumner, A.J.2
  • 4
    • 34250886406 scopus 로고    scopus 로고
    • Food pathogen detection
    • Batt, C.A. Food pathogen detection. Science 2007, 316, 1579-1580.
    • (2007) Science , vol.316 , pp. 1579-1580
    • Batt, C.A.1
  • 5
    • 33846448162 scopus 로고    scopus 로고
    • Pathogen detection: A perspective of traditional methods and biosensors
    • Lazcka, O.; Del Campo, F.J.; Munoz, F.X. Pathogen detection: a perspective of traditional methods and biosensors. Biosens. Bioelectron. 2007, 22, 1205-1217.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 1205-1217
    • Lazcka, O.1    Del Campo, F.J.2    Munoz, F.X.3
  • 6
    • 38349133990 scopus 로고    scopus 로고
    • Electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria
    • Yang, L.; Bashir, R. Electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria. Biotechnol. Adv. 2008, 26, 135-150.
    • (2008) Biotechnol. Adv , vol.26 , pp. 135-150
    • Yang, L.1    Bashir, R.2
  • 7
    • 49849102138 scopus 로고    scopus 로고
    • Towards on-site pathogen detection using antibodybased sensors
    • Skottrup, P.D.; Nicolaisen, M.; Justesen, A.F. Towards on-site pathogen detection using antibodybased sensors. Biosens. Bioelectron. 2008, 24, 339-348.
    • (2008) Biosens. Bioelectron , vol.24 , pp. 339-348
    • Skottrup, P.D.1    Nicolaisen, M.2    Justesen, A.F.3
  • 8
    • 48249150392 scopus 로고    scopus 로고
    • Cantilever biosensors
    • Fritz, J. Cantilever biosensors. Analyst 2008, 133, 855-863.
    • (2008) Analyst , vol.133 , pp. 855-863
    • Fritz, J.1
  • 10
    • 0035715839 scopus 로고    scopus 로고
    • DNA-gold conjugates for the detection of specific molecular interactions
    • Fritzsche, W. DNA-gold conjugates for the detection of specific molecular interactions. Rev. Mol. Biotechnol. 2001, 82, 37-46.
    • (2001) Rev. Mol. Biotechnol , vol.82 , pp. 37-46
    • Fritzsche, W.1
  • 11
    • 0029975638 scopus 로고    scopus 로고
    • Direct enzyme-amplified electrical recognition of a 30-base model oligonucleotide
    • de Lumley-Woodyear, T.; Campbell, C.N.; Heller, A. Direct enzyme-amplified electrical recognition of a 30-base model oligonucleotide. J. Am. Chem. Soc. 1996, 118, 5504-5505.
    • (1996) J. Am. Chem. Soc , vol.118 , pp. 5504-5505
    • de Lumley-Woodyear, T.1    Campbell, C.N.2    Heller, A.3
  • 12
    • 0027668945 scopus 로고
    • Sequence-selective biosensor for DNA based on electroactive hybridization indicators
    • Millan, K.M.; Mikkelsen, S.R. Sequence-selective biosensor for DNA based on electroactive hybridization indicators. Anal. Chem. 1993, 65, 2317-2323.
    • (1993) Anal. Chem , vol.65 , pp. 2317-2323
    • Millan, K.M.1    Mikkelsen, S.R.2
  • 13
    • 0027967657 scopus 로고
    • Voltammetric DNA biosensor for cystic fibrosis based on a modified carbon paste electrode
    • Millan, K.M.; Saraullo, A.; Mikkelsen, S R. Voltammetric DNA biosensor for cystic fibrosis based on a modified carbon paste electrode. Anal. Chem. 1994, 66, 2943-2948.
    • (1994) Anal. Chem , vol.66 , pp. 2943-2948
    • Millan, K.M.1    Saraullo, A.2    Mikkelsen, S.R.3
  • 14
    • 0035120564 scopus 로고    scopus 로고
    • Electrochemical detection of sequence-specific DNA using a DNA probe labeled with aminoferrocene and chitosan modified electrode immobilized with ssDNA
    • Xu, C.; Cai, H.; He, P.; Fang, Y. Electrochemical detection of sequence-specific DNA using a DNA probe labeled with aminoferrocene and chitosan modified electrode immobilized with ssDNA. Analyst 2001, 126, 62-65.
    • (2001) Analyst , vol.126 , pp. 62-65
    • Xu, C.1    Cai, H.2    He, P.3    Fang, Y.4
  • 15
    • 0034654434 scopus 로고    scopus 로고
    • DNA sensing on a DNA probemodified electrode using ferrocenylnaphthalene diimide as the electrochemically active ligand
    • Takenaka, S.; Yamashita, K.; Takagi, M.; Uto, Y.; Kondo, H. DNA sensing on a DNA probemodified electrode using ferrocenylnaphthalene diimide as the electrochemically active ligand. Anal. Chem. 2000, 72, 1334-1341.
    • (2000) Anal. Chem , vol.72 , pp. 1334-1341
    • Takenaka, S.1    Yamashita, K.2    Takagi, M.3    Uto, Y.4    Kondo, H.5
  • 16
    • 34548639001 scopus 로고    scopus 로고
    • On-chip microfluidic biosensor for bacterial detection and identification
    • Boehm, D.A.; Gottlieb, P.A.; Hua, S.Z. On-chip microfluidic biosensor for bacterial detection and identification. Sens. Actuators B 2007, B126, 508-514.
    • (2007) Sens. Actuators B , vol.B126 , pp. 508-514
    • Boehm, D.A.1    Gottlieb, P.A.2    Hua, S.Z.3
  • 17
    • 62749092115 scopus 로고    scopus 로고
    • A microfluidic chip for real-time studies of the volume of single cells
    • Hua, S.Z.; Thomas, P. A microfluidic chip for real-time studies of the volume of single cells. Lab. Chip 2009, 9, 251-256.
    • (2009) Lab. Chip , vol.9 , pp. 251-256
    • Hua, S.Z.1    Thomas, P.2
  • 18
    • 41149104835 scopus 로고    scopus 로고
    • Direct electrical detection of target cells on a microfluidic biochip
    • 68860B/68861-68860B/68810
    • Javanmard, M.; Talasaz, A.H.; Nemat-Gorgani, M.; Pease, F.; Ronaghi, M.; Davis, R.W. Direct electrical detection of target cells on a microfluidic biochip. Proc. SPIE 2008, 6886, 68860B/68861-68860B/68810.
    • (2008) Proc. SPIE , vol.6886
    • Javanmard, M.1    Talasaz, A.H.2    Nemat-Gorgani, M.3    Pease, F.4    Ronaghi, M.5    Davis, R.W.6
  • 19
    • 36348971066 scopus 로고    scopus 로고
    • Development of a microfluidic biochip for online monitoring of fungal biofilm dynamics
    • Richter, L.; Stepper, C.; Mak, A.; Reinthaler, A.; Heer, R.; Kast, M.; Brueckl, H.; Ertl, P. Development of a microfluidic biochip for online monitoring of fungal biofilm dynamics. Lab. Chip 2007, 7, 1723-1731.
    • (2007) Lab. Chip , vol.7 , pp. 1723-1731
    • Richter, L.1    Stepper, C.2    Mak, A.3    Reinthaler, A.4    Heer, R.5    Kast, M.6    Brueckl, H.7    Ertl, P.8
  • 22
    • 39449122974 scopus 로고    scopus 로고
    • Development of a Faradic impedimetric immunosensor for the detection of Salmonella typhimurium in milk
    • Mantzila, A.G.; Maipa, V.; Prodromidis, M.I. Development of a Faradic impedimetric immunosensor for the detection of Salmonella typhimurium in milk. Anal. Chem. 2008, 80, 1169-1175
    • (2008) Anal. Chem , vol.80 , pp. 1169-1175
    • Mantzila, A.G.1    Maipa, V.2    Prodromidis, M.I.3
  • 23
    • 37349013278 scopus 로고    scopus 로고
    • The development of a labeless immunosensor for the detection of Listeria monocytogenes cell surface protein, Internalin B
    • Tully, E.; Higson, S.P.; O'Kennedy, R. The development of a labeless immunosensor for the detection of Listeria monocytogenes cell surface protein, Internalin B. Biosens. Bioelectron. 2008, 23, 906-912.
    • (2008) Biosens. Bioelectron , vol.23 , pp. 906-912
    • Tully, E.1    Higson, S.P.2    O'Kennedy, R.3
  • 24
    • 40649089602 scopus 로고    scopus 로고
    • Electrical detection and characterization of bacterial adhesion using electrochemical impedance spectroscopy-based flow chamber
    • Bayoudh, S.; Othmane, A.; Ponsonnet, L.; Ben Ouada, H. Electrical detection and characterization of bacterial adhesion using electrochemical impedance spectroscopy-based flow chamber. Colloids Surf. A 2008, 318, 291-300.
    • (2008) Colloids Surf. A , vol.318 , pp. 291-300
    • Bayoudh, S.1    Othmane, A.2    Ponsonnet, L.3    Ben, O.H.4
  • 26
    • 54749134679 scopus 로고    scopus 로고
    • Detection of Escherichia coli and Salmonella typhimurium using interdigitated microelectrode capacitive immunosensors: The importance of transducer geometry
    • Lazcka, O.; Baldrich, E.; Munoz, F.X.; del Campo, F.J. Detection of Escherichia coli and Salmonella typhimurium using interdigitated microelectrode capacitive immunosensors: the importance of transducer geometry. Anal. Chem. 2008, 80, 7239-7247.
    • (2008) Anal. Chem , vol.80 , pp. 7239-7247
    • Lazcka, O.1    Baldrich, E.2    Munoz, F.X.3    del Campo, F.J.4
  • 27
    • 11144231293 scopus 로고    scopus 로고
    • A high density microelectrode array biosensor for detection of E. coli O157:H7
    • Radke, S.M.; Alocilja, E.C. A high density microelectrode array biosensor for detection of E. coli O157:H7. Biosens. Bioelectron. 2005, 20, 1662-1667.
    • (2005) Biosens. Bioelectron , vol.20 , pp. 1662-1667
    • Radke, S.M.1    Alocilja, E.C.2
  • 28
    • 1642370490 scopus 로고    scopus 로고
    • Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium
    • Yang, L.; Li, Y.; Griffis, C.L.; Johnson, M.G. Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium. Biosens. Bioelectron. 2004, 19, 1139-1147.
    • (2004) Biosens. Bioelectron , vol.19 , pp. 1139-1147
    • Yang, L.1    Li, Y.2    Griffis, C.L.3    Johnson, M.G.4
  • 29
    • 35748931751 scopus 로고    scopus 로고
    • A label-free, microfluidics and interdigitated array microelectrode-based impedance biosensor in combination with nanoparticles immunoseparation for detection of Escherichia coli O157:H7 in food samples
    • Varshney, M.; Li, Y.; Srinivasan, V.; Tung, S. A label-free, microfluidics and interdigitated array microelectrode-based impedance biosensor in combination with nanoparticles immunoseparation for detection of Escherichia coli O157:H7 in food samples. Sens. Actuat. A 2007, 128, 99-107.
    • (2007) Sens. Actuat. A , vol.128 , pp. 99-107
    • Varshney, M.1    Li, Y.2    Srinivasan, V.3    Tung, S.4
  • 31
    • 1242338814 scopus 로고    scopus 로고
    • Interdigitated array microelectrode-based electrochemical impedance immunosensor for detection of Escherichia coli O157:H7
    • Yang, L.; Li, Y.; Erf, G.F. Interdigitated array microelectrode-based electrochemical impedance immunosensor for detection of Escherichia coli O157:H7. Anal. Chem. 2004, 76, 1107-1113.
    • (2004) Anal. Chem , vol.76 , pp. 1107-1113
    • Yang, L.1    Li, Y.2    Erf, G.F.3
  • 32
    • 35548951784 scopus 로고    scopus 로고
    • Total nucleic acid analysis integrated on microfluidic devices
    • Chen, L.; Manz, A.; Day, P.J.R. Total nucleic acid analysis integrated on microfluidic devices. Lab. Chip 2007, 7, 1413-1423.
    • (2007) Lab. Chip , vol.7 , pp. 1413-1423
    • Chen, L.1    Manz, A.2    Day, P.J.R.3
  • 33
    • 4344700526 scopus 로고    scopus 로고
    • Filter-based microfluidic device for immunofluorescent assay of microbial cells
    • Zhu, L.; Zhang, Q.; Feng, H.; Ang, S.; Chau, F.S.; Liu, W.T. Filter-based microfluidic device for immunofluorescent assay of microbial cells. Lab. Chip 2004, 4, 337-341.
    • (2004) Lab. Chip , vol.4 , pp. 337-341
    • Zhu, L.1    Zhang, Q.2    Feng, H.3    Ang, S.4    Chau, F.S.5    Liu, W.T.6
  • 34
    • 52449127957 scopus 로고    scopus 로고
    • Immunomagnetic bead-based cell concentration microdevice for dilute pathogen detection
    • Beyor, N.; Seo, T.S.; Liu, P.; Mathies, R.A. Immunomagnetic bead-based cell concentration microdevice for dilute pathogen detection. Biomed. Microdev. 2008, 10, 909-917.
    • (2008) Biomed. Microdev , vol.10 , pp. 909-917
    • Beyor, N.1    Seo, T.S.2    Liu, P.3    Mathies, R.A.4
  • 35
    • 15544362224 scopus 로고    scopus 로고
    • Fabrication of a dielectrophoretic chip with 3D silicon electrodes
    • Iliescu, C.; Xu, G.L.; Samper, V.; Tay, F.E.H. Fabrication of a dielectrophoretic chip with 3D silicon electrodes. J. Micromech. Microeng. 2005, 15, 494-500.
    • (2005) J. Micromech. Microeng , vol.15 , pp. 494-500
    • Iliescu, C.1    Xu, G.L.2    Samper, V.3    Tay, F.E.H.4
  • 36
    • 0032840907 scopus 로고    scopus 로고
    • Dielectrophoresis of human red cells in microchips
    • Xu, C.X.; Wang, Y.; Cao, M.; Lu, Z.H. Dielectrophoresis of human red cells in microchips. Electrophoresis 1999, 20, 1829-1831.
    • (1999) Electrophoresis , vol.20 , pp. 1829-1831
    • Xu, C.X.1    Wang, Y.2    Cao, M.3    Lu, Z.H.4
  • 38
    • 33751007558 scopus 로고    scopus 로고
    • A DNA biochip for on-the-spot multiplexed pathogen identification
    • Yeung, S.-W.; Lee, T. M.-H.; Cai, H.; Hsing, I.-M. A DNA biochip for on-the-spot multiplexed pathogen identification. Nucleic Acids Res. 2006, 34, e118.
    • (2006) Nucleic Acids Res , vol.34
    • Yeung, S.-W.1    Lee T., M.-H.2    Cai, H.3    Hsing, I.-M.4
  • 39
    • 33745509562 scopus 로고    scopus 로고
    • Microchip-based one step DNA extraction and real-time PCR in one chamber for rapid pathogen identification
    • Lee, J.-G.; Cheong, K.H.; Huh, N.; Kim, S.; Choi, J.-W.; Ko, C. Microchip-based one step DNA extraction and real-time PCR in one chamber for rapid pathogen identification. Lab. Chip 2006, 6, 886-895.
    • (2006) Lab. Chip , vol.6 , pp. 886-895
    • Lee, J.-G.1    Cheong, K.H.2    Huh, N.3    Kim, S.4    Choi, J.-W.5    Ko, C.6
  • 40
    • 42549103536 scopus 로고    scopus 로고
    • Gold nanoparticles for one step for DNA extraction and real-time PCR of pathogens in a single chamber
    • Cheong, K.H.; Yi, D.K.; Lee, J.-G.; Park, J.-M.; Kim, M.J.; Edel, J.B.; Ko, C. Gold nanoparticles for one step for DNA extraction and real-time PCR of pathogens in a single chamber. Lab. Chip 2008, 8, 810-813.
    • (2008) Lab. Chip , vol.8 , pp. 810-813
    • Cheong, K.H.1    Yi, D.K.2    Lee, J.-G.3    Park, J.-M.4    Kim, M.J.5    Edel, J.B.6    Ko, C.7
  • 41
    • 1842834076 scopus 로고    scopus 로고
    • Reagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation
    • Di Carlo, D.; Jeong, K.H.; Lee, L.P. Reagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation. Lab. Chip 2003, 3, 287-291.
    • (2003) Lab. Chip , vol.3 , pp. 287-291
    • Di Carlo, D.1    Jeong, K.H.2    Lee, L.P.3
  • 42
    • 20444403042 scopus 로고    scopus 로고
    • Cell stimulus and lysis in a microfluidic device with segmented gas-liquid flow
    • El-Ali, J.; Gaudet, S.; Guenther, A.; Sorger, P.K.; Jensen, K. F. Cell stimulus and lysis in a microfluidic device with segmented gas-liquid flow. Anal. Chem. 2005, 77, 3629-3636.
    • (2005) Anal. Chem , vol.77 , pp. 3629-3636
    • El-Ali, J.1    Gaudet, S.2    Guenther, A.3    Sorger, P.K.4    Jensen, K.F.5
  • 43
    • 0031569477 scopus 로고    scopus 로고
    • Transport, manipulation, and reaction of biological cells on-chip using electrokinetic effects
    • Li, P.C.H.; Harrison, D.J. Transport, manipulation, and reaction of biological cells on-chip using electrokinetic effects. Anal. Chem. 1997, 69, 1564-1568.
    • (1997) Anal. Chem , vol.69 , pp. 1564-1568
    • Li, P.C.H.1    Harrison, D.J.2
  • 45
    • 1542614140 scopus 로고    scopus 로고
    • Nucleic acid purification using microfabricated silicon structures
    • Cady, N.C.; Stelick, S.; Batt, C.A. Nucleic acid purification using microfabricated silicon structures. Biosens. Bioelectron. 2003, 19, 59-66.
    • (2003) Biosens. Bioelectron , vol.19 , pp. 59-66
    • Cady, N.C.1    Stelick, S.2    Batt, C.A.3
  • 47
    • 13844308101 scopus 로고    scopus 로고
    • Extrinsic Fabry-Perot interferometry for noncontact temperature control of nanoliter-volume enzymatic reactions in glass microchips
    • Easley, C.J.; Legendre, L.A.; Roper, M.G.; Wavering, T.A.; Ferrance, J.P.; Landers, J.P. Extrinsic Fabry-Perot interferometry for noncontact temperature control of nanoliter-volume enzymatic reactions in glass microchips. Anal. Chem. 2005, 77, 1038-1045.
    • (2005) Anal. Chem , vol.77 , pp. 1038-1045
    • Easley, C.J.1    Legendre, L.A.2    Roper, M.G.3    Wavering, T.A.4    Ferrance, J.P.5    Landers, J.P.6
  • 49
    • 0041837248 scopus 로고    scopus 로고
    • Integrating polymerase chain reaction, valving, and electrophoresis in a plastic device for bacterial detection
    • Koh, C.G.; Tan, W.; Zhao, M.-Q.; Ricco, A.J.; Fan, Z.H. Integrating polymerase chain reaction, valving, and electrophoresis in a plastic device for bacterial detection. Anal. Chem. 2003, 75, 4591-4598.
    • (2003) Anal. Chem , vol.75 , pp. 4591-4598
    • Koh, C.G.1    Tan, W.2    Zhao, M.-Q.3    Ricco, A.J.4    Fan, Z.H.5
  • 50
    • 1842477059 scopus 로고    scopus 로고
    • Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection
    • Liu, R.H.; Yang, J.; Lenigk, R.; Bonanno, J.; Grodzinski, P. Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection. Anal. Chem. 2004, 76, 1824-1831.
    • (2004) Anal. Chem , vol.76 , pp. 1824-1831
    • Liu, R.H.1    Yang, J.2    Lenigk, R.3    Bonanno, J.4    Grodzinski, P.5
  • 51
    • 29144446032 scopus 로고    scopus 로고
    • A nanoparticle amplification based quartz crystal microbalance DNA sensor for detection of Escherichia coli O157:H7
    • Mao, X.; Yang, L.; Su, X.-L.; Li, Y. A nanoparticle amplification based quartz crystal microbalance DNA sensor for detection of Escherichia coli O157:H7. Biosens. Bioelectron. 2006, 21, 1178-1185.
    • (2006) Biosens. Bioelectron , vol.21 , pp. 1178-1185
    • Mao, X.1    Yang, L.2    Su, X.-L.3    Li, Y.4
  • 55
    • 33746035696 scopus 로고    scopus 로고
    • A DNA microarray platform based on direct detection of rRNA for characterization of freshwater sediment-related prokaryotic communities
    • Peplies, J.; Lachmund, C.; Gloeckner, F. O.; Manz, W. A DNA microarray platform based on direct detection of rRNA for characterization of freshwater sediment-related prokaryotic communities. Appl. Environ. Microbiol. 2006, 72, 4829-4838.
    • (2006) Appl. Environ. Microbiol , vol.72 , pp. 4829-4838
    • Peplies, J.1    Lachmund, C.2    Gloeckner, F.O.3    Manz, W.4
  • 56
    • 0036488787 scopus 로고    scopus 로고
    • The role of intimin in the adherence of enterohaemorrhagic Escherichia coli (EHEC) O157: H7 to HEp-2 tissue culture cells and to bovine gut explant tissues
    • Cookson, A.L.; Woodward, M.J. The role of intimin in the adherence of enterohaemorrhagic Escherichia coli (EHEC) O157: H7 to HEp-2 tissue culture cells and to bovine gut explant tissues. Int. J. Med. Microbiol. 2003, 292, 547-553.
    • (2003) Int. J. Med. Microbiol , vol.292 , pp. 547-553
    • Cookson, A.L.1    Woodward, M.J.2
  • 58
    • 11144285416 scopus 로고    scopus 로고
    • Adherence of diarrheagenic Escherichia coli strains to epithelial cells
    • Torres, A.G.; Zhou, X.; Kaper, J.B. Adherence of diarrheagenic Escherichia coli strains to epithelial cells. Infect. Immun. 2005, 73, 18-29.
    • (2005) Infect. Immun , vol.73 , pp. 18-29
    • Torres, A.G.1    Zhou, X.2    Kaper, J.B.3
  • 59
    • 54949146496 scopus 로고    scopus 로고
    • Sample processing for DNA chip array-based analysis of enterohemorrhagic Escherichia coli (EHEC)
    • doi: 10.1186/1475-2859-7-29
    • Basselet, P.; Wegrzyn, G.; Enfors, S.-O.; Gabig-Ciminska, M. Sample processing for DNA chip array-based analysis of enterohemorrhagic Escherichia coli (EHEC). Microb. Cell Fact. 2008, 7, 6 doi: 10.1186/1475-2859-7-29.
    • (2008) Microb. Cell Fact , vol.7 , pp. 6
    • Basselet, P.1    Wegrzyn, G.2    Enfors, S.-O.3    Gabig-Ciminska, M.4
  • 60
    • 42549150052 scopus 로고    scopus 로고
    • Enhanced microfiltration devices configured with hydrodynamic trapping and a rain drop bypass filtering architecture for microbial cell detection
    • Lay, C.; Teo, C. Y.; Zhu, L.; Peh, X.L.; Ji, H.M.; Chew, B.-R.; Murthy, R.; Feng, H.H.; Liu, W.-T. Enhanced microfiltration devices configured with hydrodynamic trapping and a rain drop bypass filtering architecture for microbial cell detection. Lab. Chip 2008, 8, 830-833.
    • (2008) Lab. Chip , vol.8 , pp. 830-833
    • Lay, C.1    Teo, C.Y.2    Zhu, L.3    Peh, X.L.4    Ji, H.M.5    Chew, B.-R.6    Murthy, R.7    Feng, H.H.8    Liu, W.-T.9
  • 61
    • 33847218638 scopus 로고    scopus 로고
    • Single-cell detection: Test of microbial contamination using capillary electrophoresis
    • Lantz, A.W.; Bao, Y.; Armstrong, D.W. Single-cell detection: test of microbial contamination using capillary electrophoresis. Anal. Chem. 2007, 79, 1720-1724.
    • (2007) Anal. Chem , vol.79 , pp. 1720-1724
    • Lantz, A.W.1    Bao, Y.2    Armstrong, D.W.3
  • 62
    • 33746220398 scopus 로고    scopus 로고
    • Capillary electrophoretic method for the detection of bacterial contamination
    • Rodriguez, M.A.; Lantz, A.W.; Armstrong, D.W. Capillary electrophoretic method for the detection of bacterial contamination. Anal. Chem. 2006, 78, 4759-4767.
    • (2006) Anal. Chem , vol.78 , pp. 4759-4767
    • Rodriguez, M.A.1    Lantz, A.W.2    Armstrong, D.W.3
  • 63
    • 34447650564 scopus 로고    scopus 로고
    • Rapid identification of purified enteropathogenic Escherichia coli by microchip electrophoresis
    • Law, W.S.; Tay, E. T.T.; Feng, H.; Yu, L.; Zha, J.H.; Li, S.F.Y. Rapid identification of purified enteropathogenic Escherichia coli by microchip electrophoresis. J. Sep. Sci. 2007, 30, 1446-1452.
    • (2007) J. Sep. Sci , vol.30 , pp. 1446-1452
    • Law, W.S.1    Tay, E.T.T.2    Feng, H.3    Yu, L.4    Zha, J.H.5    Li, S.F.Y.6
  • 65
    • 34547103752 scopus 로고    scopus 로고
    • In situ detection of Bacillus anthracis spores using fully submersible, self-exciting, self-sensing PMN-Pt/Sn piezolelectric microcantilevers
    • McGovern, J.-P.; Shih, W.Y.; Shih, W.-H. In situ detection of Bacillus anthracis spores using fully submersible, self-exciting, self-sensing PMN-Pt/Sn piezolelectric microcantilevers. Analyst 2007, 132, 777-783.
    • (2007) Analyst , vol.132 , pp. 777-783
    • McGovern, J.-P.1    Shih, W.Y.2    Shih, W.-H.3
  • 66
    • 42449100022 scopus 로고    scopus 로고
    • Label-free flowenhanced specific detection of Bacillus anthracis using a piezoelectric microcantilever sensor
    • McGovern, J.-P.; Shih, W.Y.; Rest, R.; Purohit, M.; Pandya, Y.; Shih, W.-H. Label-free flowenhanced specific detection of Bacillus anthracis using a piezoelectric microcantilever sensor. Analyst 2008, 133, 649-654.
    • (2008) Analyst , vol.133 , pp. 649-654
    • McGovern, J.-P.1    Shih, W.Y.2    Rest, R.3    Purohit, M.4    Pandya, Y.5    Shih, W.-H.6
  • 67
    • 34247578242 scopus 로고    scopus 로고
    • A simple method to integrate in situ nano-particle focusing with cantilever detection
    • Wu, J.; Islam, N. A simple method to integrate in situ nano-particle focusing with cantilever detection. IEEE Sensors Journal 2007, 7, 957-958.
    • (2007) IEEE Sensors Journal , vol.7 , pp. 957-958
    • Wu, J.1    Islam, N.2
  • 72
    • 33845256207 scopus 로고    scopus 로고
    • Microelectrical noise detector for rapid, specific, and sensitive identification of bacteria
    • Seo, S.; Kim, H.C.; Cheng, M.; Ruan, X.; Ruan, W. Microelectrical noise detector for rapid, specific, and sensitive identification of bacteria. J. Vac. Sci. Technol., B 2006, 24, 3133-3138.
    • (2006) J. Vac. Sci. Technol., B , vol.24 , pp. 3133-3138
    • Seo, S.1    Kim, H.C.2    Cheng, M.3    Ruan, X.4    Ruan, W.5
  • 73
    • 48149093146 scopus 로고    scopus 로고
    • Fast detection of Salmonella Infantis with carbon nanotube field effect transistors
    • Villamizar, R.A.; Maroto, A.; Rius, F. X.; Inza, I.; Figueras, M.J. Fast detection of Salmonella Infantis with carbon nanotube field effect transistors. Biosens. Bioelectron. 2008, 24, 279-283.
    • (2008) Biosens. Bioelectron , vol.24 , pp. 279-283
    • Villamizar, R.A.1    Maroto, A.2    Rius, F.X.3    Inza, I.4    Figueras, M.J.5
  • 74
    • 54549103406 scopus 로고    scopus 로고
    • Fabrication of bio/nano interfaces between biological cells and carbon nanotubes using dielectrophoresis
    • Suehiro, J.; Ikeda, N.; Ohtsubo, A.; Imasaka, K. Fabrication of bio/nano interfaces between biological cells and carbon nanotubes using dielectrophoresis. Microfluid. Nanofluid. 2008, 5, 741-747.
    • (2008) Microfluid. Nanofluid , vol.5 , pp. 741-747
    • Suehiro, J.1    Ikeda, N.2    Ohtsubo, A.3    Imasaka, K.4
  • 75
    • 57049152893 scopus 로고    scopus 로고
    • Label-free pathogen detection with sensor chips assembled from peptide nanotubes
    • de la Rica, R.; Mendoza, E.; Lechuga, L.M.; Matsui, H. Label-free pathogen detection with sensor chips assembled from peptide nanotubes. Angew. Chem. Int. Ed. 2008, 47, 9752-9755.
    • (2008) Angew. Chem. Int. Ed , vol.47 , pp. 9752-9755
    • de la Rica, R.1    Mendoza, E.2    Lechuga, L.M.3    Matsui, H.4
  • 76
    • 33847342833 scopus 로고    scopus 로고
    • Nanowire labeled direct-charge transfer biosensor for detecting Bacillus species
    • Pal, S.; Alocilja, E.C.; Downes, F.P. Nanowire labeled direct-charge transfer biosensor for detecting Bacillus species. Biosens. Bioelectron. 2007, 22, 2329-2336.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 2329-2336
    • Pal, S.1    Alocilja, E.C.2    Downes, F.P.3
  • 79
    • 23044432937 scopus 로고    scopus 로고
    • Detection of single bacterial pathogens with semiconductor quantum dots
    • Hahn, M.A.; Tabb, J.S.; Krauss, T.D. Detection of single bacterial pathogens with semiconductor quantum dots. Anal. Chem. 2005, 77, 4861-4869.
    • (2005) Anal. Chem , vol.77 , pp. 4861-4869
    • Hahn, M.A.1    Tabb, J.S.2    Krauss, T.D.3
  • 80
    • 33644631872 scopus 로고    scopus 로고
    • Simultaneous detection of Esherichia coli O157:H7 and Salmonella Typhimurium using quantum dots as fluorescent labels
    • Yang, L.; Li, Y. Simultaneous detection of Esherichia coli O157:H7 and Salmonella Typhimurium using quantum dots as fluorescent labels. Analyst 2006, 131, 394-401.
    • (2006) Analyst , vol.131 , pp. 394-401
    • Yang, L.1    Li, Y.2
  • 81
    • 36448943989 scopus 로고    scopus 로고
    • Detection of pathogen using luminescent CdSe/ZnS dendron nanocrystals and a porous membrane immunofilter
    • Liu, Y.; Brandon, R.; Cate, M.; Peng, X.; Stony, R.; Johnson, M. Detection of pathogen using luminescent CdSe/ZnS dendron nanocrystals and a porous membrane immunofilter. Anal. Chem. 2007, 79, 8796-8802.
    • (2007) Anal. Chem , vol.79 , pp. 8796-8802
    • Liu, Y.1    Brandon, R.2    Cate, M.3    Peng, X.4    Stony, R.5    Johnson, M.6
  • 82
    • 61449147073 scopus 로고    scopus 로고
    • Synthesis of fluorescent carbohydrate-protected Au nanodots for detection of Concanavalin A and Escherichia coli
    • Huang, C.-C.; Chen, C.-T.; Shiang, Y.-C.; Lin, Z.-H.; Chang, H.-T. Synthesis of fluorescent carbohydrate-protected Au nanodots for detection of Concanavalin A and Escherichia coli. Anal. Chem. 2009, 81, 875-882.
    • (2009) Anal. Chem , vol.81 , pp. 875-882
    • Huang, C.-C.1    Chen, C.-T.2    Shiang, Y.-C.3    Lin, Z.-H.4    Chang, H.-T.5
  • 86
    • 17144419663 scopus 로고    scopus 로고
    • Immunoassay for B. globigii spores as a model for detecting B. anthracis spores in finished water
    • Farrel, S.; Halsall, B.; Heineman, W.R. Immunoassay for B. globigii spores as a model for detecting B. anthracis spores in finished water. Analyst 2005, 130, 489-497.
    • (2005) Analyst , vol.130 , pp. 489-497
    • Farrel, S.1    Halsall, B.2    Heineman, W.R.3
  • 87
    • 35948933369 scopus 로고    scopus 로고
    • Magnetic glyco-nanoparticles: A unique tool for rapid pathogen detection, decontamination, and strain differentiation
    • El-Boubbou, K.; Gruden, C.; Huang, X. Magnetic glyco-nanoparticles: a unique tool for rapid pathogen detection, decontamination, and strain differentiation. J. Am. Chem. Soc. 2007, 129, 13392-13393.
    • (2007) J. Am. Chem. Soc , vol.129 , pp. 13392-13393
    • El-Boubbou, K.1    Gruden, C.2    Huang, X.3
  • 88
    • 43449114775 scopus 로고    scopus 로고
    • Disposable amperometric immunosensing strips fabricated by Au nanoparticles-modified screenprinted carbon electrodes for the detection of foodborne pathogen Escherichia coli O157:H7
    • Lin, Y.-H.; Chen, S.-H.; Chuang, Y.-C.; Lu, Y.-C.; Shen, T.-Y.; Chang, C.-A.; Lin, C.-S. Disposable amperometric immunosensing strips fabricated by Au nanoparticles-modified screenprinted carbon electrodes for the detection of foodborne pathogen Escherichia coli O157:H7. Biosens. Bioelectron. 2008, 23, 1832-1837.
    • (2008) Biosens. Bioelectron , vol.23 , pp. 1832-1837
    • Lin, Y.-H.1    Chen, S.-H.2    Chuang, Y.-C.3    Lu, Y.-C.4    Shen, T.-Y.5    Chang, C.-A.6    Lin, C.-S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.