메뉴 건너뛰기




Volumn 59, Issue 3, 2009, Pages 366-368

Immunomagnetic bead separation of mononuclear cells from contaminating granulocytes in cryopreserved blood samples

Author keywords

Cryopreservation; Density gradient centrifugation; Granulocytes; Human blood; Immunomagnetic beads; Mononuclear cells

Indexed keywords

CD15 ANTIGEN;

EID: 70649095177     PISSN: 00112240     EISSN: 10902392     Source Type: Journal    
DOI: 10.1016/j.cryobiol.2009.09.008     Document Type: Article
Times cited : (7)

References (10)
  • 1
    • 0016961001 scopus 로고
    • Isolation of lymphocytes, granulocytes and macrophages
    • Boyum A. Isolation of lymphocytes, granulocytes and macrophages. Scand. J. Immunol. Suppl. 5 (1976) 9-15
    • (1976) Scand. J. Immunol. Suppl. , vol.5 , pp. 9-15
    • Boyum, A.1
  • 2
    • 0023899107 scopus 로고
    • Granulocyte contamination of Ficoll-Hypaque preparations of mononuclear cells following thermal injury may lead to substantial overestimation of lymphocyte recovery
    • Calvano S.E., Greenlee P.G., Reid A.M., deRiesthal H.F., Shires G.T., and Antonacci A.C. Granulocyte contamination of Ficoll-Hypaque preparations of mononuclear cells following thermal injury may lead to substantial overestimation of lymphocyte recovery. J. Trauma 28 (1988) 353-361
    • (1988) J. Trauma , vol.28 , pp. 353-361
    • Calvano, S.E.1    Greenlee, P.G.2    Reid, A.M.3    deRiesthal, H.F.4    Shires, G.T.5    Antonacci, A.C.6
  • 3
    • 0019137066 scopus 로고
    • Separation of viable from nonviable cells using a discontinuous density gradient
    • Clynes M.M., Smyth H., O'Kennedy R., and Corrigan A. Separation of viable from nonviable cells using a discontinuous density gradient. In Vitro 16 (1980) 809-812
    • (1980) In Vitro , vol.16 , pp. 809-812
    • Clynes, M.M.1    Smyth, H.2    O'Kennedy, R.3    Corrigan, A.4
  • 4
    • 0020857720 scopus 로고
    • Granulocytes in gradient separations of stored blood
    • Dzik W.H. Granulocytes in gradient separations of stored blood. Transfusion 23 (1983) 538-539
    • (1983) Transfusion , vol.23 , pp. 538-539
    • Dzik, W.H.1
  • 5
    • 0016007887 scopus 로고
    • Cell separation by gradient centrifugation
    • Harwood R. Cell separation by gradient centrifugation. Int. Rev. Cytol. 38 (1974) 369-403
    • (1974) Int. Rev. Cytol. , vol.38 , pp. 369-403
    • Harwood, R.1
  • 6
    • 0019301323 scopus 로고
    • A rapid and efficient procedure for the removal of nonviable cells from suspension culture of lymphoid cell lines
    • Hurrell J.G., Black P.H., Haber E., and Zurawski Jr. V.R. A rapid and efficient procedure for the removal of nonviable cells from suspension culture of lymphoid cell lines. Aust. J. Exp. Biol. Med. Sci. 58 (1980) 373-376
    • (1980) Aust. J. Exp. Biol. Med. Sci. , vol.58 , pp. 373-376
    • Hurrell, J.G.1    Black, P.H.2    Haber, E.3    Zurawski Jr., V.R.4
  • 7
    • 33847610140 scopus 로고    scopus 로고
    • Basic Principles in Clinical Flow Cytometry
    • Karen D.F., McCoy Jr. J.P., and Carey J.L. (Eds), ASCP Press, Chicago
    • McCoy Jr. J.P. Basic Principles in Clinical Flow Cytometry. In: Karen D.F., McCoy Jr. J.P., and Carey J.L. (Eds). Flow Cytometry in Clinical Diagnosis. third ed. (2001), ASCP Press, Chicago 39-45
    • (2001) Flow Cytometry in Clinical Diagnosis. third ed. , pp. 39-45
    • McCoy Jr., J.P.1
  • 8
    • 42549121038 scopus 로고    scopus 로고
    • Optimization of flow cytometric measurement of ZAP-70 in chronic lymphocytic leukemia
    • Preobrazhensky S.N., and Bahler D.W. Optimization of flow cytometric measurement of ZAP-70 in chronic lymphocytic leukemia. Cytometry B Clin. Cytom. 74 (2008) 118-1127
    • (2008) Cytometry B Clin. Cytom. , vol.74 , pp. 118-1127
    • Preobrazhensky, S.N.1    Bahler, D.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.