메뉴 건너뛰기




Volumn 74, Issue 2, 2008, Pages 118-127

Optimization of flow cytometric measurement of ZAP-70 in chronic lymphocytic leukemia

Author keywords

CLL, scatchard analysis; Flow cytometry; ZAP 70

Indexed keywords

ANTIGEN; DYE; FLUORESCEIN ISOTHIOCYANATE; PROTEIN; PROTEIN ANTIBODY; SAPONIN; TRITON X 100; UNCLASSIFIED DRUG; ZETA CHAIN ASSOCIATED PROTEIN 70;

EID: 42549121038     PISSN: 15524949     EISSN: 15524957     Source Type: Journal    
DOI: 10.1002/cyto.b.20378     Document Type: Article
Times cited : (14)

References (35)
  • 1
    • 0028292001 scopus 로고
    • Human severe combined immunodeficiency due to a defect in ZAP-70, a T cell tyrosine kinase
    • Elder ME, Lin D, Clever J, Chan AC, Hope TJ, Weiss A, Parslow TG. Human severe combined immunodeficiency due to a defect in ZAP-70, a T cell tyrosine kinase. Science 1994;264:1596-1599.
    • (1994) Science , vol.264 , pp. 1596-1599
    • Elder, M.E.1    Lin, D.2    Clever, J.3    Chan, A.C.4    Hope, T.J.5    Weiss, A.6    Parslow, T.G.7
  • 2
    • 0028209548 scopus 로고
    • Sequential interactions of the TCR with two distinct cytoplasmic tyrosine kinases
    • Iwashima M, Irving BA, van Oers NS, Chan AC, Weiss A. Sequential interactions of the TCR with two distinct cytoplasmic tyrosine kinases. Science 1994;263:1136-1139.
    • (1994) Science , vol.263 , pp. 1136-1139
    • Iwashima, M.1    Irving, B.A.2    van Oers, N.S.3    Chan, A.C.4    Weiss, A.5
  • 4
    • 28844449552 scopus 로고    scopus 로고
    • Functional and prognostic role of ZAP-70 in chronic lymphocytic leukaemia
    • Hamblin AD, Hamblin TJ. Functional and prognostic role of ZAP-70 in chronic lymphocytic leukaemia. Expert Opin Ther Targets 2005;9: 1165-1178.
    • (2005) Expert Opin Ther Targets , vol.9 , pp. 1165-1178
    • Hamblin, A.D.1    Hamblin, T.J.2
  • 14
    • 33748488256 scopus 로고    scopus 로고
    • Flow cytometry for ZAP-70: New colors for chronic lymphocytic leukemia
    • Wiestner A. Flow cytometry for ZAP-70: New colors for chronic lymphocytic leukemia. Cytometry B Clin Cytom 2006;70B:201-203.
    • (2006) Cytometry B Clin Cytom , vol.70 B , pp. 201-203
    • Wiestner, A.1
  • 15
    • 33748515699 scopus 로고    scopus 로고
    • ZAP-70 in CLL: Towards standardization of a biomarker for patient management: History of clinical cytometry special issue
    • Marti G, Orfao A, Goolsby C. ZAP-70 in CLL: Towards standardization of a biomarker for patient management: History of clinical cytometry special issue. Cytometry B Clin Cytom 2006;70B:197-200.
    • (2006) Cytometry B Clin Cytom , vol.70 B , pp. 197-200
    • Marti, G.1    Orfao, A.2    Goolsby, C.3
  • 16
    • 33748484706 scopus 로고    scopus 로고
    • Comparison of methods for determining zeta-chain associated protein-70 (ZAP-70) expression in patients with B-cell chronic lymphocytic leukemia (B-CLL)
    • Bojarska-Junak A, Giannopoulos K, Kowal M, Dmoszynska A, Rolinski J. Comparison of methods for determining zeta-chain associated protein-70 (ZAP-70) expression in patients with B-cell chronic lymphocytic leukemia (B-CLL). Cytometry B Clin Cytom 2006;70B:293-301.
    • (2006) Cytometry B Clin Cytom , vol.70 B , pp. 293-301
    • Bojarska-Junak, A.1    Giannopoulos, K.2    Kowal, M.3    Dmoszynska, A.4    Rolinski, J.5
  • 18
    • 33748486024 scopus 로고    scopus 로고
    • A robust ratio metric method for analysis of Zap-70 expression in chronic lymphocytic leukemia (CLL)
    • Bakke AC, Purtzer Z, Leis J, Huang J. A robust ratio metric method for analysis of Zap-70 expression in chronic lymphocytic leukemia (CLL). Cytometry B Clin Cytom 2005;70B:227-234.
    • (2005) Cytometry B Clin Cytom , vol.70 B , pp. 227-234
    • Bakke, A.C.1    Purtzer, Z.2    Leis, J.3    Huang, J.4
  • 21
    • 23444453040 scopus 로고    scopus 로고
    • Comparison of flow cytometric methods for the measurement of ZAP-70 expression in a routine diagnostic laboratory
    • Gibbs G, Bromidge T, Howe D, Hopkins J, Johnson S. Comparison of flow cytometric methods for the measurement of ZAP-70 expression in a routine diagnostic laboratory. Clin Lab Haematol 2005;27: 258-266.
    • (2005) Clin Lab Haematol , vol.27 , pp. 258-266
    • Gibbs, G.1    Bromidge, T.2    Howe, D.3    Hopkins, J.4    Johnson, S.5
  • 22
    • 33748512177 scopus 로고    scopus 로고
    • Quantitative flow cytometry of ZAP-70 levels in chronic lymphocytic leukemia using molecules of equivalent soluble fluorochrome
    • Kay S, Herishanu Y, Pick M, Rogowski O, Baron S, Naparstek E, Polliack A, Deutsch VR. Quantitative flow cytometry of ZAP-70 levels in chronic lymphocytic leukemia using molecules of equivalent soluble fluorochrome. Cytometry B Clin Cytom 2006;70B:218-226.
    • (2006) Cytometry B Clin Cytom , vol.70 B , pp. 218-226
    • Kay, S.1    Herishanu, Y.2    Pick, M.3    Rogowski, O.4    Baron, S.5    Naparstek, E.6    Polliack, A.7    Deutsch, V.R.8
  • 23
    • 33748494685 scopus 로고    scopus 로고
    • Use of a blocking antibody method for the flow cytometric measurement of ZAP-70 in B-CLL
    • Shenkin M, Maiese R. Use of a blocking antibody method for the flow cytometric measurement of ZAP-70 in B-CLL. Cytometry B Clin Cytom 2006;70B:251-258.
    • (2006) Cytometry B Clin Cytom , vol.70 B , pp. 251-258
    • Shenkin, M.1    Maiese, R.2
  • 24
    • 33748508638 scopus 로고    scopus 로고
    • Comparison of bone marrow and peripheral blood ZAP-70 status examined by flow cytometric immunophenotyping in patients with chronic lymphocytic leukemia
    • Sheridan R, Mounajjed T, Ehrmann DE, Hurtubise PE, Schrager JA. Comparison of bone marrow and peripheral blood ZAP-70 status examined by flow cytometric immunophenotyping in patients with chronic lymphocytic leukemia. Cytometry B Clin Cytom 2006;70B: 319-320.
    • (2006) Cytometry B Clin Cytom , vol.70 B , pp. 319-320
    • Sheridan, R.1    Mounajjed, T.2    Ehrmann, D.E.3    Hurtubise, P.E.4    Schrager, J.A.5
  • 25
    • 33748484269 scopus 로고    scopus 로고
    • Discordant results of flow cytometric ZAP-70 expression status in B-CLL samples if different gating strategies are applied
    • Wilhelm C, Neubauer A, Brendel C. Discordant results of flow cytometric ZAP-70 expression status in B-CLL samples if different gating strategies are applied. Cytometry B Clin Cytom 2006;70B:242-250.
    • (2006) Cytometry B Clin Cytom , vol.70 B , pp. 242-250
    • Wilhelm, C.1    Neubauer, A.2    Brendel, C.3
  • 27
    • 0013592069 scopus 로고
    • Intracellular antigen staining. Methods: A
    • Jacobberger JW. Intracellular antigen staining. Methods: A Companion Methods Enzymol 1991;2:207-218.
    • (1991) Companion Methods Enzymol , vol.2 , pp. 207-218
    • Jacobberger, J.W.1
  • 29
    • 24944560467 scopus 로고    scopus 로고
    • Whole blood fixation and permeabilization protocol with red blood cell lysis for flow cytometry of intracellular phosphorylated epitopes in leukocyte subpopulations
    • Chow S, Hedley D, Grom P, Magari R, Jacobberger JW, Shankey TV. Whole blood fixation and permeabilization protocol with red blood cell lysis for flow cytometry of intracellular phosphorylated epitopes in leukocyte subpopulations. Cytometry A 2005;67A:4-17.
    • (2005) Cytometry A , vol.67 A , pp. 4-17
    • Chow, S.1    Hedley, D.2    Grom, P.3    Magari, R.4    Jacobberger, J.W.5    Shankey, T.V.6
  • 30
    • 0031614185 scopus 로고    scopus 로고
    • Detection of intracellular/intranuclear antigens in tumor cells
    • Widen RH, Becker JL. Detection of intracellular/intranuclear antigens in tumor cells. Methods Mol Biol 1998;91:57-65.
    • (1998) Methods Mol Biol , vol.91 , pp. 57-65
    • Widen, R.H.1    Becker, J.L.2
  • 31
    • 0007652805 scopus 로고
    • Scatchard analysis by flow cytometry
    • Radburch A, editor, Berlin: Springer-Verlag;
    • Murphy R.F. Scatchard analysis by flow cytometry. In:Radburch A, editor. Flow Cytometry and Cell Sorting. Berlin: Springer-Verlag; 1992. pp 59-62.
    • (1992) Flow Cytometry and Cell Sorting , pp. 59-62
    • Murphy, R.F.1
  • 32
    • 3242854520 scopus 로고
    • Rate and equilibrium constants for binding of apo-E HDLc (a cholesterol-induced lipoprotein) and low density lipoproteins to human fibroblasts: Evidence for multiple receptor binding of apo-E HDLc
    • Pitas RE, Innerarity TL, Arnold KS, Mahley RW. Rate and equilibrium constants for binding of apo-E HDLc (a cholesterol-induced lipoprotein) and low density lipoproteins to human fibroblasts: Evidence for multiple receptor binding of apo-E HDLc. Proc Natl Acad Sci USA 1979;76:2311-2315.
    • (1979) Proc Natl Acad Sci USA , vol.76 , pp. 2311-2315
    • Pitas, R.E.1    Innerarity, T.L.2    Arnold, K.S.3    Mahley, R.W.4
  • 33
    • 0029132029 scopus 로고
    • Binding kinetics of ecotropic (Moloney) murine leukemia retrovirus with NIH 3T3 cells
    • Yu H, Soong N, Anderson WF. Binding kinetics of ecotropic (Moloney) murine leukemia retrovirus with NIH 3T3 cells. J Virol 1995;69:6557-6562.
    • (1995) J Virol , vol.69 , pp. 6557-6562
    • Yu, H.1    Soong, N.2    Anderson, W.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.