메뉴 건너뛰기




Volumn 91, Issue 4, 2009, Pages 1100-1110

In vivo production of nanosized metal wear debris formed by tribochemical reaction as confirmed by high-resolution TEM and XPS analyses

Author keywords

Metal on metal; Nanoparticles; TEM; Wear debris; XPS

Indexed keywords

BASE ALLOYS; CARBON-RICH LAYERS; CHROMIUM LAYER; FEMORAL HEADS; GLOBULAR PARTICLES; HIGH RESOLUTION; HIGH-RESOLUTION TEM; IN-VIVO; METAL OXIDES; METAL WEAR; METAL-ON-METAL; NANO-SIZED; SHAPED PARTICLES; SOLID DEPOSITS; TEM; THICK LAYERS; TRIBOCHEMICAL REACTION; WEAR DEBRIS; WEAR PARTICLES; XPS; XPS ANALYSIS;

EID: 70450164378     PISSN: 15493296     EISSN: 15524965     Source Type: Journal    
DOI: 10.1002/jbm.a.32301     Document Type: Article
Times cited : (61)

References (36)
  • 2
    • 34748921063 scopus 로고    scopus 로고
    • Wear particles, periprosthetic osteolysis and the immune system
    • Goodman SB. Wear particles, periprosthetic osteolysis and the immune system. Biomaterials 2007;28:5044-5048.
    • (2007) Biomaterials , vol.28 , pp. 5044-5048
    • Goodman, S.B.1
  • 3
    • 0037290074 scopus 로고    scopus 로고
    • Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro
    • DOI 10.1016/S0142-9612(02)00360-5, PII S0142961202003605
    • Germain MA, Hatton A, Williams S, Matthews JB, Stone MH, Fisher J, Ingham E. Comparison of cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro. Biomaterials 2003;24:469-479. (Pubitemid 35287518)
    • (2003) Biomaterials , vol.24 , Issue.3 , pp. 469-479
    • Germain, M.A.1    Hatton, A.2    Williams, S.3    Matthews, J.B.4    Stone, M.H.5    Fisher, J.6    Ingham, E.7
  • 4
    • 4744355541 scopus 로고    scopus 로고
    • The role of macrophages in osteolysis of total joint replacement
    • DOI 10.1016/j.biomaterials.2004.04.035, PII S014296120400393X
    • Ingham E, Fisher J. The role of macrophages in osteolysis of total joint replacement. Biomaterials 2005;26:1271-1286. (Pubitemid 39314501)
    • (2005) Biomaterials , vol.26 , Issue.11 , pp. 1271-1286
    • Ingham, E.1    Fisher, J.2
  • 6
    • 34250754537 scopus 로고    scopus 로고
    • Orthopaedic metals and their potential toxicity in the arthroplasty patient
    • Keegan GM, Learmonth ID, Case CP. Orthopaedic metals and their potential toxicity in the arthroplasty patient. J Bone Joint Surg Br 2007;89:5567-5573.
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 5567-5573
    • Keegan, G.M.1    Learmonth, I.D.2    Case, C.P.3
  • 8
    • 0028144389 scopus 로고
    • Trace element reference values in tissues from inhabitants of the European Community. V. Review of trace elements in blood, serum and urine and critical evaluation of reference values for Danish population
    • Poulsen OM, Molin Christensen J, Sabbioni E, Van der Venne MT. Trace element reference values in tissues from inhabitants of the European Community. V. Review of trace elements in blood, serum and urine and critical evaluation of reference values for Danish population. Sci Total Environ 1994;141:197-215.
    • (1994) Sci Total Environ , vol.141 , pp. 197-215
    • Poulsen, O.M.1    Molin Christensen, J.2    Sabbioni, E.3    Van Der Venne, M.T.4
  • 10
    • 18244384199 scopus 로고    scopus 로고
    • Serum levels of cobalt and chromium in patients with Sikomet metal-metal total hip replacements
    • DOI 10.1016/j.orthres.2004.12.007, PII S0736026605000707
    • Milošev I, Pišot V, Campbell P. Serum levels of cobalt and chromium in patients with Sikomet metal-on-metal total hip replacements. J Orthop Res 2005;23:526-535. (Pubitemid 40631322)
    • (2005) Journal of Orthopaedic Research , vol.23 , Issue.3 , pp. 526-535
    • Milosev, I.1    Pisot, V.2    Campbell, P.3
  • 12
    • 0026656109 scopus 로고
    • Metall-Metall-Totalprothese des Hüftgelekes: Züruck in die Zukunft
    • Weber BG. Metall-Metall-Totalprothese des Hüftgelekes: Züruck in die Zukunft. Z Orthop 1992;130:306-309.
    • (1992) Z Orthop , vol.130 , pp. 306-309
    • Weber, B.G.1
  • 15
    • 0035811273 scopus 로고    scopus 로고
    • Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. I. Analysis of particle size and shape
    • Catelas I, Bobyn JD, Medley JB, Krygier JJ, Zukor DJ, Petir A, Huk OL. Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. I. Analysis of particle size and shape. J Biomed Mater Res 2001;55:320-337.
    • (2001) J Biomed Mater Res , vol.55 , pp. 320-337
    • Catelas, I.1    Bobyn, J.D.2    Medley, J.B.3    Krygier, J.J.4    Zukor, D.J.5    Petir, A.6    Huk, O.L.7
  • 16
    • 0032837830 scopus 로고    scopus 로고
    • Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements
    • DOI 10.1023/A:1026473723777
    • Tipper JL, Firkins PJ, Ingham E, Fisher J, Stone MH, Farrar R. Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements. J Mater Sci: Mater Med 1999;10:353-362. (Pubitemid 29363878)
    • (1999) Journal of Materials Science: Materials in Medicine , vol.10 , Issue.6 , pp. 353-362
    • Tipper, J.L.1    Firkins, P.J.2    Ingham, E.3    Fisher, J.4    Stone, M.H.5    Farrar, R.6
  • 19
    • 33645217648 scopus 로고    scopus 로고
    • Metal-on-metal hip simulator study of increased wear particle surface area due to "severe" patient activity
    • Bowsher JG, Hussain A, Williams PA, Shelton JC. Metal-on-metal hip simulator study of increased wear particle surface area due to "severe" patient activity. Proc Inst Mech Eng Part H: J Eng Med 2006;220:279-287.
    • (2006) Proc Inst Mech Eng Part H: J Eng Med , vol.220 , pp. 279-287
    • Bowsher, J.G.1    Hussain, A.2    Williams, P.A.3    Shelton, J.C.4
  • 20
    • 0032190304 scopus 로고    scopus 로고
    • Metal wear particle characterization from metal on metal total hip replacements: Transmission electron microscopy study of periprosthetic tissues and isolated particles
    • DOI 10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.0.CO;2-M
    • Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC. Metal wear particle characterization from metal on metal total hip replacement: Transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res 1998;42:103-111. (Pubitemid 28413002)
    • (1998) Journal of Biomedical Materials Research , vol.42 , Issue.1 , pp. 103-111
    • Doorn, P.F.1    Campbell, P.A.2    Worrall, J.3    Benya, P.D.4    McKellop, H.A.5    Amstutz, H.C.6
  • 21
  • 23
    • 33744785097 scopus 로고    scopus 로고
    • Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years
    • DOI 10.2106/JBJS.E.00604
    • Milošev I, Trebše R, Kovač S, Cör A, Pišot V. Survivorship and retrieval analysis of Sikomet metal-on-metal total hip arthroplasty at a mean of seven years. J Bone Joint Surg Am 2006;88:1173-1182. (Pubitemid 43837109)
    • (2006) Journal of Bone and Joint Surgery - Series a , vol.88 , Issue.6 , pp. 1173-1182
    • Milosev, I.1    Trebse, R.2    Kovac, S.3    Cor, A.4    Pisot, V.5
  • 24
    • 34147223855 scopus 로고    scopus 로고
    • The effect of nano- And micron-sized particles of cobalt-chromium alloy on human fibroblasts in vitro
    • DOI 10.1016/j.biomaterials.2007.02.034, PII S0142961207001901
    • Papageorgiou I, Brown C, Schins R, Singh S, Newson R, Davis S, Fisher J, Ingham E, Case CP. The effect of nano- and micron-sized particles of cobalt-chromium alloy on human fibroblasts in vitro. Biomaterials 2007;28:2946-2958. (Pubitemid 46578251)
    • (2007) Biomaterials , vol.28 , Issue.19 , pp. 2946-2958
    • Papageorgiou, I.1    Brown, C.2    Schins, R.3    Singh, S.4    Newson, R.5    Davis, S.6    Fisher, J.7    Ingham, E.8    Case, C.P.9
  • 25
    • 0042171490 scopus 로고    scopus 로고
    • The composition of the passive film formed on CoCrMo alloy in simulated physiological solution
    • Milošev I, Strehblow H-H. The composition of the passive film formed on CoCrMo alloy in simulated physiological solution. Electrochim Acta 2003;48:2767-2774.
    • (2003) Electrochim Acta , vol.48 , pp. 2767-2774
    • Milošev, I.1    Strehblow, H.-H.2
  • 27
    • 70450143045 scopus 로고    scopus 로고
    • Joint Committe on Powder Diffraction Standards - International Centre for Diffraction Data, PDF numbers: 9-345, 33-297, 41-489
    • Joint Committe on Powder Diffraction Standards - International Centre for Diffraction Data, www.icdd.com, PDF numbers: 9-345, 33-297, 41-489.
  • 28
    • 0035482039 scopus 로고    scopus 로고
    • The acting mechanisms on metal-on-metal hip joint bearings: In vitro results
    • Wimmer MA, Loos J, Nassutt R, Heitkemper M, Fischer A. The acting mechanisms on metal-on-metal hip joint bearings: In vitro results. Wear 2001;250:129-139.
    • (2001) Wear , vol.250 , pp. 129-139
    • Wimmer, M.A.1    Loos, J.2    Nassutt, R.3    Heitkemper, M.4    Fischer, A.5
  • 29
    • 0042564752 scopus 로고    scopus 로고
    • Tribochemical reaction on metal-on-metal hip joint bearings. A comparison between in-vitro and in-vivo results
    • Wimmer MA, Sprecher C, Hauert R, Täger G, Fischer A. Tribochemical reaction on metal-on-metal hip joint bearings. A comparison between in-vitro and in-vivo results. Wear 2003;255:1007-1014.
    • (2003) Wear , vol.255 , pp. 1007-1014
    • Wimmer, M.A.1    Sprecher, C.2    Hauert, R.3    Täger, G.4    Fischer, A.5
  • 32
    • 0030935497 scopus 로고    scopus 로고
    • Experimentelle Untersuchungen an Metall-Metall-Gleitpaarungen und ihre Wertigkeit hinsichtlich eines zu erwartenden In-vivo-Verhaltens
    • DOI 10.1007/s001320050079
    • Plitz W, Huber J, Refior HJ. Experimentelle Untersuchungen an Metall-Metall-Gleitpaarungen undihre Wertigketi hinsichtlich eines zu erwartenden In-vivo-Verhaltens. Orthpäde 1997;26:135-141. (Pubitemid 27119569)
    • (1997) Orthopade , vol.26 , Issue.2 , pp. 135-141
    • Plitz, W.1    Huber, J.2    Refior, H.J.3
  • 33
    • 0028999336 scopus 로고
    • Release of hexavalent chromium from corrosion of stainless steel and cobalt-chromium alloys
    • Merritt K, Brown SA. Release of hexavalent chromium from corrosion of stainless steel and cobalt-chromium alloys. J Biomed Mater Res 1995;29:627-633.
    • (1995) J Biomed Mater Res , vol.29 , pp. 627-633
    • Merritt, K.1    Brown, S.A.2
  • 34
    • 0035882642 scopus 로고    scopus 로고
    • Examination of in vivo influences of bioluminescent microbial assessment of corrosion product toxicity
    • Shettlemore MG, Bundy KJ. Examination of in vivo influences of bioluminescent microbial assessment of corrosion product toxicity. Biomaterials 2001;22:2215-2228.
    • (2001) Biomaterials , vol.22 , pp. 2215-2228
    • Shettlemore, M.G.1    Bundy, K.J.2
  • 36
    • 0021459367 scopus 로고
    • In vivo production of hexavalent chromium
    • Rogers GT. In vivo production of hexavalent chromium. Biomaterials 1984;5:244-245.
    • (1984) Biomaterials , vol.5 , pp. 244-245
    • Rogers, G.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.