메뉴 건너뛰기




Volumn 72, Issue 3, 2009, Pages 432-439

Focal liver lesion detection and characterization: Comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging

Author keywords

Diffusion magnetic resonance imaging; EPI; Ferucarbotran; Liver

Indexed keywords

B VALUE; CONSPICUITY; CONTRAST-ENHANCED; DIFFUSION MAGNETIC RESONANCE IMAGING; ECHO PLANAR IMAGING; ENHANCED DIFFUSION; EXACT TESTS; FOCAL LIVER LESIONS; LESION DETECTION; LIVER METASTASIS; MALIGNANT LESION; RANK-ORDER STATISTICS; REFERENCE STANDARD; SINGLE-SHOT; SPIN ECHO; SUPERPARAMAGNETIC IRON OXIDES; T2-WEIGHTED IMAGING; TURBO SPIN ECHOS;

EID: 70449633653     PISSN: 0720048X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejrad.2008.09.005     Document Type: Article
Times cited : (22)

References (18)
  • 1
    • 33745966057 scopus 로고    scopus 로고
    • New MR techniques for the detection of liver metastases
    • Ward J. New MR techniques for the detection of liver metastases. Cancer Imaging 6 (2006) 33-42
    • (2006) Cancer Imaging , vol.6 , pp. 33-42
    • Ward, J.1
  • 2
    • 12544252337 scopus 로고    scopus 로고
    • Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging
    • Kim Y., Lee J., Kim C., Chung G., Kim C., and Kim I. Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging. Eur Radiol 15 (2005) 220-228
    • (2005) Eur Radiol , vol.15 , pp. 220-228
    • Kim, Y.1    Lee, J.2    Kim, C.3    Chung, G.4    Kim, C.5    Kim, I.6
  • 3
    • 4744367361 scopus 로고    scopus 로고
    • Detection and characterization of focal hepatic lesions: mangafodipir vs. superparamagnetic iron oxide-enhanced magnetic resonance imaging
    • Kim M., Kim J., Lim J., et al. Detection and characterization of focal hepatic lesions: mangafodipir vs. superparamagnetic iron oxide-enhanced magnetic resonance imaging. JMRI 20 (2004) 612-621
    • (2004) JMRI , vol.20 , pp. 612-621
    • Kim, M.1    Kim, J.2    Lim, J.3
  • 4
    • 33645115696 scopus 로고    scopus 로고
    • Hepatic metastases: diffusion-weighted sensitivity-encoding versus SPIO-enhanced MR imaging
    • Nasu K., Kuroki Y., Nawano S., et al. Hepatic metastases: diffusion-weighted sensitivity-encoding versus SPIO-enhanced MR imaging. Radiology 239 (2006) 122-130
    • (2006) Radiology , vol.239 , pp. 122-130
    • Nasu, K.1    Kuroki, Y.2    Nawano, S.3
  • 6
    • 39049083433 scopus 로고    scopus 로고
    • Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique
    • Bruegel M., Holzapfel K., Gaa J., et al. Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique. Eur Radiol 18 (2008) 477-485
    • (2008) Eur Radiol , vol.18 , pp. 477-485
    • Bruegel, M.1    Holzapfel, K.2    Gaa, J.3
  • 7
    • 0027993463 scopus 로고
    • Hepatic hemangiomas: a multi-institutional study of appearance on T2-weighted and serial gadolinium-enhanced gradient-echo MR images
    • Semelka R., Brown E., Ascher S., et al. Hepatic hemangiomas: a multi-institutional study of appearance on T2-weighted and serial gadolinium-enhanced gradient-echo MR images. Radiology 192 (1994) 401-406
    • (1994) Radiology , vol.192 , pp. 401-406
    • Semelka, R.1    Brown, E.2    Ascher, S.3
  • 8
    • 0028080944 scopus 로고
    • Hepatic tumors: detection and characterization at 1-T MR imaging enhanced with AMI-25
    • Denys A., Arrive L., Servois V., Dubray B., Najmark D., Sibert A., and Menu Y. Hepatic tumors: detection and characterization at 1-T MR imaging enhanced with AMI-25. Radiology 193 (1994) 665-669
    • (1994) Radiology , vol.193 , pp. 665-669
    • Denys, A.1    Arrive, L.2    Servois, V.3    Dubray, B.4    Najmark, D.5    Sibert, A.6    Menu, Y.7
  • 9
    • 0034053652 scopus 로고    scopus 로고
    • Characterization of focal hepatic lesions with ferumoxides-enhanced T2-weighted MR imaging
    • Paley M., Mergo P., Torres G., et al. Characterization of focal hepatic lesions with ferumoxides-enhanced T2-weighted MR imaging. Am J Roentgenol 175 (2000) 159-163
    • (2000) Am J Roentgenol , vol.175 , pp. 159-163
    • Paley, M.1    Mergo, P.2    Torres, G.3
  • 10
    • 0029053490 scopus 로고
    • Benign hepatocellular tumors: MRI after superparamagnetic iron oxide administration
    • Grandin C., Van Beers B., Robert A., et al. Benign hepatocellular tumors: MRI after superparamagnetic iron oxide administration. J Comput Assist Tomogr 19 (1995) 412-418
    • (1995) J Comput Assist Tomogr , vol.19 , pp. 412-418
    • Grandin, C.1    Van Beers, B.2    Robert, A.3
  • 11
    • 0029808352 scopus 로고    scopus 로고
    • Detection of hepatic metastases: ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography
    • Seneterre E., Taourel P., Bouvier Y., et al. Detection of hepatic metastases: ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography. Radiology 200 (1996) 785-792
    • (1996) Radiology , vol.200 , pp. 785-792
    • Seneterre, E.1    Taourel, P.2    Bouvier, Y.3
  • 12
    • 0032956637 scopus 로고    scopus 로고
    • Hepatic lesion detection: comparison of MR imaging after the administration of superparamagnetic iron oxide with dual-phase CT by using alternative-free response receiver operating characteristic analysis
    • Ward J., Naik K., Guthrie J., Wilson D., and Robinson P. Hepatic lesion detection: comparison of MR imaging after the administration of superparamagnetic iron oxide with dual-phase CT by using alternative-free response receiver operating characteristic analysis. Radiology 210 (1999) 459-466
    • (1999) Radiology , vol.210 , pp. 459-466
    • Ward, J.1    Naik, K.2    Guthrie, J.3    Wilson, D.4    Robinson, P.5
  • 13
    • 0034877607 scopus 로고    scopus 로고
    • Conspicuity of hepatocellular nodular lesions in cirrhotic livers at ferumoxides-enhanced MR imaging: importance of Kupffer cell number
    • Lim J., Choi D., Cho S., et al. Conspicuity of hepatocellular nodular lesions in cirrhotic livers at ferumoxides-enhanced MR imaging: importance of Kupffer cell number. Radiology 220 (2001) 669-676
    • (2001) Radiology , vol.220 , pp. 669-676
    • Lim, J.1    Choi, D.2    Cho, S.3
  • 14
    • 0002945732 scopus 로고
    • How to use RIDIT analysis
    • Bross I.D.J. How to use RIDIT analysis. Biometrics 14 (1958) 18-38
    • (1958) Biometrics , vol.14 , pp. 18-38
    • Bross, I.D.J.1
  • 15
    • 33646712315 scopus 로고    scopus 로고
    • Evaluation of super paramagnetic iron oxide-enhanced diffusion-weighted PROPELLER T2-fast spin echo magnetic resonance imaging: Preliminary experience
    • Kiryu S., Watanabe M., Kabasawa H., Akahane M., Aoki S., and Ohtomo K. Evaluation of super paramagnetic iron oxide-enhanced diffusion-weighted PROPELLER T2-fast spin echo magnetic resonance imaging: Preliminary experience. J Comput Assist Tomogr 30 (2006) 197-200
    • (2006) J Comput Assist Tomogr , vol.30 , pp. 197-200
    • Kiryu, S.1    Watanabe, M.2    Kabasawa, H.3    Akahane, M.4    Aoki, S.5    Ohtomo, K.6
  • 16
    • 33750531208 scopus 로고    scopus 로고
    • Detection of hepatic metastases using ferucarbotran-enhanced MR imaging: Feasibility and diagnostic accuracy of three-dimensional sensitivity-encoding water-excitation multishot echo-planar sequence (3D-SWEEP)
    • Mori K., Takahashi N., Hiratsuka M., et al. Detection of hepatic metastases using ferucarbotran-enhanced MR imaging: Feasibility and diagnostic accuracy of three-dimensional sensitivity-encoding water-excitation multishot echo-planar sequence (3D-SWEEP). JMRI 24 (2006) 1110-1116
    • (2006) JMRI , vol.24 , pp. 1110-1116
    • Mori, K.1    Takahashi, N.2    Hiratsuka, M.3
  • 17
    • 20044394195 scopus 로고    scopus 로고
    • Diffusion-weighted images of the liver: comparison of tumor detection before and after contrast enhancement with superparamagnetic iron oxide
    • Naganawa S., Sato C., Nakamura T., et al. Diffusion-weighted images of the liver: comparison of tumor detection before and after contrast enhancement with superparamagnetic iron oxide. JMRI 21 (2005) 836-840
    • (2005) JMRI , vol.21 , pp. 836-840
    • Naganawa, S.1    Sato, C.2    Nakamura, T.3
  • 18
    • 37849048271 scopus 로고    scopus 로고
    • Improved focal liver lesion detection: comparison of single-shot spin-echo echo-planar and superparamagnetic iron oxide (SPIO)-enhanced MRI
    • Coenegrachts K., Orlent H., ter Beek L., et al. Improved focal liver lesion detection: comparison of single-shot spin-echo echo-planar and superparamagnetic iron oxide (SPIO)-enhanced MRI. JMRI 27 (2008) 117-124
    • (2008) JMRI , vol.27 , pp. 117-124
    • Coenegrachts, K.1    Orlent, H.2    ter Beek, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.