메뉴 건너뛰기




Volumn 13, Issue 4, 2009, Pages 512-517

Bioreactance: A new tool for cardiac output and thoracic fluid content monitoring during hemodialysis

Author keywords

Bioreactance; Fluid removal; Hemodialysis; Noninvasive hemodynamic monitoring; Thoracic fluid content

Indexed keywords

ACCURACY; AGED; ARTICLE; BODY WEIGHT; CLINICAL ARTICLE; COHORT ANALYSIS; CORRELATION ANALYSIS; DEVICE; FEMALE; HEART OUTPUT; HEMATOCRIT; HEMODIALYSIS; HEMODIALYSIS PATIENT; HEMODYNAMICS; HIGH RISK PATIENT; HUMAN; IMPEDANCE; MALE; MEASUREMENT; MONITORING; NON INVASIVE PROCEDURE; PLEURA FLUID; TOTAL BODY WATER; WEIGHT REDUCTION;

EID: 70350542844     PISSN: 14927535     EISSN: 15424758     Source Type: Journal    
DOI: 10.1111/j.1542-4758.2009.00386.x     Document Type: Article
Times cited : (37)

References (30)
  • 1
    • 2442681474 scopus 로고    scopus 로고
    • Cardiac diseases in maintenance hemodialysis patients
    • Cheung AK, Sarnak MJ, Yan G. Cardiac diseases in maintenance hemodialysis patients. Kidney Int 2004, 65:2380-2389.
    • (2004) Kidney Int , vol.65 , pp. 2380-2389
    • Cheung, A.K.1    Sarnak, M.J.2    Yan, G.3    et al4
  • 2
    • 33645313451 scopus 로고    scopus 로고
    • Intradialytic complications during hemodialysis
    • Davenport A. Intradialytic complications during hemodialysis. Hemodial Int 2006, 10:162-167.
    • (2006) Hemodial Int , vol.10 , pp. 162-167
    • Davenport, A.1
  • 3
    • 0034770116 scopus 로고    scopus 로고
    • Clinical case-based approach to understanding intradialytic hypotension
    • Schreiber MJ. Clinical case-based approach to understanding intradialytic hypotension. Am J Kidney Dis 2001, 38((Suppl 4)):S37-S47.
    • (2001) Am J Kidney Dis , vol.38 , Issue.SUPPL 4
    • Schreiber, M.J.1
  • 4
    • 0033864894 scopus 로고    scopus 로고
    • Impact of biofeedback-induced cardiovascular stability on hemodialysis tolerance and efficiency
    • Ronco C, Brendolan A, Milan M, Rodeghiero MP, Zanella M, La Greca G. Impact of biofeedback-induced cardiovascular stability on hemodialysis tolerance and efficiency. Kidney Int 2000, 58:800-808.
    • (2000) Kidney Int , vol.58 , pp. 800-808
    • Ronco, C.1    Brendolan, A.2    Milan, M.3    Rodeghiero, M.P.4    Zanella, M.5    La Greca, G.6
  • 6
    • 1642545129 scopus 로고    scopus 로고
    • Model-based study of the effects of the hemodialysis technique on the compensatory response to hypovolemia
    • Cavalcanti S, Ciandrini A, Severi S. Model-based study of the effects of the hemodialysis technique on the compensatory response to hypovolemia. Kidney Int 2004, 65:1499-1510.
    • (2004) Kidney Int , vol.65 , pp. 1499-1510
    • Cavalcanti, S.1    Ciandrini, A.2    Severi, S.3    et al4
  • 8
    • 1642382811 scopus 로고    scopus 로고
    • Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients
    • Ishibe S, Peixoto AJ. Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients. Semin Dial 2004, 17:37-43.
    • (2004) Semin Dial , vol.17 , pp. 37-43
    • Ishibe, S.1    Peixoto, A.J.2
  • 9
    • 0036895459 scopus 로고    scopus 로고
    • The role of blood volume reduction in the genesis of intradialytic hypotension
    • Andrulli S, Colzani S, Mascia F. The role of blood volume reduction in the genesis of intradialytic hypotension. Am J Kidney Dis 2002, 40:1244-1254.
    • (2002) Am J Kidney Dis , vol.40 , pp. 1244-1254
    • Andrulli, S.1    Colzani, S.2    Mascia, F.3    et al4
  • 11
    • 35448975252 scopus 로고    scopus 로고
    • Acute effects of haemodialysis on biochemical modulators of endothelial function
    • Hewitson CL, Whiting MJ, Barbara JA, Mangoni AA. Acute effects of haemodialysis on biochemical modulators of endothelial function. J Intern Med 2007, 262:571-580.
    • (2007) J Intern Med , vol.262 , pp. 571-580
    • Hewitson, C.L.1    Whiting, M.J.2    Barbara, J.A.3    Mangoni, A.A.4
  • 12
    • 0032427658 scopus 로고    scopus 로고
    • Systemic vascular resistance in intradialytic hypotension determined by means of impedance cardiography
    • Straver B, Roggekamp MC, de Vries PM, ter Wee PM. Systemic vascular resistance in intradialytic hypotension determined by means of impedance cardiography. Blood Purif 1998, 16:281-289.
    • (1998) Blood Purif , vol.16 , pp. 281-289
    • Straver, B.1    Roggekamp, M.C.2    de Vries, P.M.3    ter Wee, P.M.4
  • 13
    • 0028464341 scopus 로고
    • Hematocrit as an indicator of blood volume and a predictor of intradialytic morbid events
    • Steuer RR, Leypoldt JK, Cheung AK, Harris DH, Conis JM. Hematocrit as an indicator of blood volume and a predictor of intradialytic morbid events. ASAIO J 1994, 40:M691-M696.
    • (1994) ASAIO J , vol.40
    • Steuer, R.R.1    Leypoldt, J.K.2    Cheung, A.K.3    Harris, D.H.4    Conis, J.M.5
  • 14
    • 0019822796 scopus 로고
    • Non-invasive monitoring of cardiac function during haemodialysis
    • Thayssen P, Andersen KH, Pindborg T. Non-invasive monitoring of cardiac function during haemodialysis. Scand J Urol Nephrol 1981, 15:313-317.
    • (1981) Scand J Urol Nephrol , vol.15 , pp. 313-317
    • Thayssen, P.1    Andersen, K.H.2    Pindborg, T.3
  • 15
    • 0028048977 scopus 로고
    • Validation study of thoracic fluid bioimpedance for assessing the haemodialysis-induced changes in total body fluids
    • Graziani G, Badalamenti S, Como G. Validation study of thoracic fluid bioimpedance for assessing the haemodialysis-induced changes in total body fluids. Blood Purif 1994, 12:106-112.
    • (1994) Blood Purif , vol.12 , pp. 106-112
    • Graziani, G.1    Badalamenti, S.2    Como, G.3    et al4
  • 16
    • 0031768672 scopus 로고    scopus 로고
    • The hemodynamic effect of different ultrafiltration rates in patients with cardiac failure and patients without cardiac failure
    • van der Sande FM, Mulder AW, Hoorntje SJ. The hemodynamic effect of different ultrafiltration rates in patients with cardiac failure and patients without cardiac failure. Clin Nephrol 1998, 50:301-308.
    • (1998) Clin Nephrol , vol.50 , pp. 301-308
    • van der Sande, F.M.1    Mulder, A.W.2    Hoorntje, S.J.3    et al4
  • 17
    • 0035169654 scopus 로고    scopus 로고
    • Should relative blood volume changes be routinely measured during the dialysis session?
    • Basile C. Should relative blood volume changes be routinely measured during the dialysis session?. Nephrol Dial Transplant 2001, 16:10-12.
    • (2001) Nephrol Dial Transplant , vol.16 , pp. 10-12
    • Basile, C.1
  • 19
    • 27744606099 scopus 로고    scopus 로고
    • Intradialytic blood volume monitoring in ambulatory hemodialysis patients
    • Reddan DN, Szczech LA, Hasselblad V. Intradialytic blood volume monitoring in ambulatory hemodialysis patients. J Am Soc Nephrol 2005, 16:2162-2169.
    • (2005) J Am Soc Nephrol , vol.16 , pp. 2162-2169
    • Reddan, D.N.1    Szczech, L.A.2    Hasselblad, V.3    et al4
  • 20
    • 38849101000 scopus 로고    scopus 로고
    • Integration of blood volume, blood pressure, heart rate and bioimpedance monitoring for the achievement of optimal dry body weight during chronic hemodialysis
    • Bonello M, House AA, Cruz D. Integration of blood volume, blood pressure, heart rate and bioimpedance monitoring for the achievement of optimal dry body weight during chronic hemodialysis. Int J Artif Organs 2007, 30:1098-1108.
    • (2007) Int J Artif Organs , vol.30 , pp. 1098-1108
    • Bonello, M.1    House, A.A.2    Cruz, D.3    et al4
  • 21
    • 38149124614 scopus 로고    scopus 로고
    • Recent advances in the prevention and management of intradialytic hypotension
    • Palmer BF, Henrich WL. Recent advances in the prevention and management of intradialytic hypotension. J Am Soc Nephrol 2008, 19:8-11.
    • (2008) J Am Soc Nephrol , vol.19 , pp. 8-11
    • Palmer, B.F.1    Henrich, W.L.2
  • 22
    • 12144256186 scopus 로고    scopus 로고
    • Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method
    • Engoren M, Barbee D. Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method. Am J Crit Care 2005, 14:40-45.
    • (2005) Am J Crit Care , vol.14 , pp. 40-45
    • Engoren, M.1    Barbee, D.2
  • 23
    • 12344278798 scopus 로고    scopus 로고
    • Non-invasive measurement of cardiac output in patients with chronic heart failure
    • Leslien S, McKee S, Newby D, Webb D, Denvir M. Non-invasive measurement of cardiac output in patients with chronic heart failure. Blood Press Monit 2004, 9:277-280.
    • (2004) Blood Press Monit , vol.9 , pp. 277-280
    • Leslien, S.1    McKee, S.2    Newby, D.3    Webb, D.4    Denvir, M.5
  • 24
    • 34547132055 scopus 로고    scopus 로고
    • Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance
    • Keren H, Burkhoff D, Squara P. Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol 2007, 293:H583-H589.
    • (2007) Am J Physiol Heart Circ Physiol , vol.293
    • Keren, H.1    Burkhoff, D.2    Squara, P.3
  • 25
    • 34848909003 scopus 로고    scopus 로고
    • Cardiac output and cardiopulmonary responses to exercise in heart failure
    • Myers J, Gujja P, Neelagaru S, Burkhoff D. Cardiac output and cardiopulmonary responses to exercise in heart failure. J Card Fail 2007, 13:629-636.
    • (2007) J Card Fail , vol.13 , pp. 629-636
    • Myers, J.1    Gujja, P.2    Neelagaru, S.3    Burkhoff, D.4
  • 28
    • 0033921109 scopus 로고    scopus 로고
    • Comparing different methods of assessing body composition in end-stage renal failure
    • Cooper BA, Aslani A, Ryan M. Comparing different methods of assessing body composition in end-stage renal failure. Kidney Int 2000, 58:408-416.
    • (2000) Kidney Int , vol.58 , pp. 408-416
    • Cooper, B.A.1    Aslani, A.2    Ryan, M.3    et al4
  • 30
    • 34548843036 scopus 로고    scopus 로고
    • Relative blood volume changes underestimate total blood volume changes during hemodialysis
    • Dasselaar JJ, Lub-de Hooge MN, Pruim J. Relative blood volume changes underestimate total blood volume changes during hemodialysis. Clin J Am Soc Nephrol 2007, 2:669-674.
    • (2007) Clin J Am Soc Nephrol , vol.2 , pp. 669-674
    • Dasselaar, J.J.1    Lub-de Hooge, M.N.2    Pruim, J.3    et al4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.