메뉴 건너뛰기




Volumn 45, Issue 22, 2009, Pages 1110-1112

Common path optical coherence tomography with fibre bundle probe

Author keywords

[No Author keywords available]

Indexed keywords

COMMON PATH; FIBRE BUNDLE; FIBRE OPTIC; INTRA-OPERATIVE; LATERAL RESOLUTION; MOVING PARTS; OPTICAL COHERENCE TOMOGRAPHY; SUBMILLIMETRE; SURGICAL TOOLS;

EID: 70350517128     PISSN: 00135194     EISSN: None     Source Type: Journal    
DOI: 10.1049/el.2009.1627     Document Type: Article
Times cited : (24)

References (12)
  • 2
    • 33646204898 scopus 로고    scopus 로고
    • Three-dimensional endoscopic optical coherence tomography by use of a two-axis microelectromechanical scanning mirror
    • Jung, W., McCormick, D.T., Zhang, J., Wang, L., Tien, N.C., and Chen, Z.: ' Three-dimensional endoscopic optical coherence tomography by use of a two-axis microelectromechanical scanning mirror ', Appl. Phys. Lett., 2006, 88, p. 163901
    • (2006) Appl. Phys. Lett. , vol.88 , pp. 163901
    • Jung, W.1    McCormick, D.T.2    Zhang, J.3    Wang, L.4    Tien, N.C.5    Chen, Z.6
  • 4
    • 17444392148 scopus 로고    scopus 로고
    • Scanningless depth-resolved microscopy
    • Oron, D., Tal, E., and Silberberg, Y.: ' Scanningless depth-resolved microscopy ', Opt. Express, 2005, 13, p. 1468-1476
    • (2005) Opt. Express , vol.13 , pp. 1468-1476
    • Oron, D.1    Tal, E.2    Silberberg, Y.3
  • 5
    • 37349079986 scopus 로고    scopus 로고
    • Scanning-less wide-field single-photon counting device for fluorescence intensity, lifetime and time-resolved anisotropy imaging microscopy
    • Spitz, J.-A., Yasukuni, R., Sandeau, N., Takano, M., Vachon, J.-J., Meallet-Renault, R., and Pansu, R.B.: ' Scanning-less wide-field single-photon counting device for fluorescence intensity, lifetime and time-resolved anisotropy imaging microscopy ', J. Microscopy, 2008, 229, p. 104-114
    • (2008) J. Microscopy , vol.229 , pp. 104-114
    • Spitz, J.-A.1    Yasukuni, R.2    Sandeau, N.3    Takano, M.4    Vachon, J.-J.5    Meallet-Renault, R.6    Pansu, R.B.7
  • 6
    • 58149105643 scopus 로고    scopus 로고
    • Experimental and theoretical analysis of core-to-core coupling on fibre bundle imaging
    • Chen, X., Reichenbach, K.L., and Xu, C.: ' Experimental and theoretical analysis of core-to-core coupling on fibre bundle imaging ', Opt. Express, 2008, 16, p. 21598-21607
    • (2008) Opt. Express , vol.16 , pp. 21598-21607
    • Chen, X.1    Reichenbach, K.L.2    Xu, C.3
  • 7
    • 33748927805 scopus 로고    scopus 로고
    • Spectrally-modulated full-field optical coherence microscopy for ultrahigh-resolution endoscopic imaging
    • DOI 10.1364/OE.14.008675
    • Oh, W.Y., Bouma, B.E., Iftimia, N., Yelin, R., and Tearney, G.J.: ' Spectrally-modulated full-field optical coherence microscopy for ultrahigh-resolution endoscopic imaging ', Opt. Express, 2006, 14, p. 8675-8684 (Pubitemid 44435078)
    • (2006) Optics Express , vol.14 , Issue.19 , pp. 8675-8684
    • Oh, W.Y.1    Bouma, B.E.2    Iftimia, N.3    Yelin, R.4    Tearney, G.J.5
  • 8
    • 36448994046 scopus 로고    scopus 로고
    • Fibre imaging bundles for full-field optical coherence tomography
    • Ford, H.D., and Tatam, R.P.: ' Fibre imaging bundles for full-field optical coherence tomography ', Meas. Sci. Technol., 2007, 18, p. 2949-2957
    • (2007) Meas. Sci. Technol. , vol.18 , pp. 2949-2957
    • Ford, H.D.1    Tatam, R.P.2
  • 9
    • 33645732570 scopus 로고    scopus 로고
    • Fourier-domain angle-resolved low coherence interferometry through an endoscopic fibre bundle for light-scattering spectroscopy
    • Pyhtila, J.W., Boyer, J.D., Chalut, K.J., and Wax, A.: ' Fourier-domain angle-resolved low coherence interferometry through an endoscopic fibre bundle for light-scattering spectroscopy ', Opt. Lett., 2006, 31, p. 772-774
    • (2006) Opt. Lett. , vol.31 , pp. 772-774
    • Pyhtila, J.W.1    Boyer, J.D.2    Chalut, K.J.3    Wax, A.4
  • 10
    • 23144433829 scopus 로고    scopus 로고
    • Fiber-optic-bundle-based optical coherence tomography
    • Xie, T., Mukai, D., Guo, S., Brenner, M., and Chen, Z.: ' Fiber-optic-bundle-based optical coherence tomography ', Opt. Lett., 2005, 30, p. 1803-1805
    • (2005) Opt. Lett. , vol.30 , pp. 1803-1805
    • Xie, T.1    Mukai, D.2    Guo, S.3    Brenner, M.4    Chen, Z.5
  • 12
    • 0344686327 scopus 로고    scopus 로고
    • Common-path interferometer for frequency-domain optical coherence tomography
    • Vakhtin, A.B., Kane, D.J., Wood, W.R., and Peterson, K.A.: ' Common-path interferometer for frequency-domain optical coherence tomography ', Appl. Opt., 2003, 42, p. 6953-6958
    • (2003) Appl. Opt. , vol.42 , pp. 6953-6958
    • Vakhtin, A.B.1    Kane, D.J.2    Wood, W.R.3    Peterson, K.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.