메뉴 건너뛰기




Volumn 92, Issue 6, 2009, Pages 476-481

Effect of cycloplegia on axial length and anterior chamber depth measurements in children

Author keywords

Anterior chamber depth; Axial length; Children; Limits of agreement

Indexed keywords

DIAGNOSTIC AGENT; MYDRIATIC AGENT;

EID: 70350437762     PISSN: 08164622     EISSN: 14440938     Source Type: Journal    
DOI: 10.1111/j.1444-0938.2009.00419.x     Document Type: Article
Times cited : (44)

References (19)
  • 1
    • 4644334484 scopus 로고    scopus 로고
    • History of ophthalmic ultrasound
    • Lizzi FL, Coleman DJ. History of ophthalmic ultrasound. J Ultrasound Med 2004 23 : 1255 1266.
    • (2004) J Ultrasound Med , vol.23 , pp. 1255-1266
    • Lizzi, F.L.1    Coleman, D.J.2
  • 2
    • 33744984829 scopus 로고    scopus 로고
    • Repeatability and agreement of two A-scan ultrasonic biometers and IOLMaster in non-orthokeratology subjects and post-orthokeratology children
    • Chan B, Cho P, Cheung SW. Repeatability and agreement of two A-scan ultrasonic biometers and IOLMaster in non-orthokeratology subjects and post-orthokeratology children. Clin Exp Optom 2006 89 : 160 168.
    • (2006) Clin Exp Optom , vol.89 , pp. 160-168
    • Chan, B.1    Cho, P.2    Cheung, S.W.3
  • 3
    • 0034747904 scopus 로고    scopus 로고
    • The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster
    • Lam AKC, Chan R, Pang PCK. The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster. Ophthalmic Physiol Opt 2001 21 : 477 483.
    • (2001) Ophthalmic Physiol Opt , vol.21 , pp. 477-483
    • Lam, A.K.C.1    Chan, R.2    Pang, P.C.K.3
  • 4
    • 0742305077 scopus 로고    scopus 로고
    • Ocular component measurement using the Zeiss IOLMaster
    • Sheng H, Bottjer CA, Bullimore MA. Ocular component measurement using the Zeiss IOLMaster. Optom Vis Sci 2004 81 : 27 34.
    • (2004) Optom Vis Sci , vol.81 , pp. 27-34
    • Sheng, H.1    Bottjer, C.A.2    Bullimore, M.A.3
  • 5
    • 0033805274 scopus 로고    scopus 로고
    • Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis
    • Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol 2000 238 : 765 773.
    • (2000) Graefes Arch Clin Exp Ophthalmol , vol.238 , pp. 765-773
    • Haigis, W.1    Lege, B.2    Miller, N.3    Schneider, B.4
  • 6
    • 43649103045 scopus 로고    scopus 로고
    • Evaluation of a new IOLMaster algorithm to measure axial length
    • Hill W, Angeles R, Otani T. Evaluation of a new IOLMaster algorithm to measure axial length. J Cataract Refract Surg 2008 34 : 920 924.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 920-924
    • Hill, W.1    Angeles, R.2    Otani, T.3
  • 8
    • 48149109261 scopus 로고    scopus 로고
    • Testability of the Retinomax autorefractor and IOLMaster in preschool children
    • MEPEDS Study Group.
    • Borchert M, Wang Y, Tarczy-Hornoch K, Cotter S, Deneen J, Azen S, Varma R, MEPEDS Study Group. Testability of the Retinomax autorefractor and IOLMaster in preschool children. Ophthalmology 2008 115 : 1422 1425.
    • (2008) Ophthalmology , vol.115 , pp. 1422-1425
    • Borchert, M.1    Wang, Y.2    Tarczy-Hornoch, K.3    Cotter, S.4    Deneen, J.5    Azen, S.6    Varma, R.7
  • 11
    • 33646762089 scopus 로고    scopus 로고
    • Evaluation of biometric methods for measuring the anterior chamber depth in the non-contact mode
    • Meinhardt B, Stachs O, Stave J, Beck R, Guthoff R. Evaluation of biometric methods for measuring the anterior chamber depth in the non-contact mode. Graefes Arch Clin Exp Ophthalmol 2006 244 : 559 564.
    • (2006) Graefes Arch Clin Exp Ophthalmol , vol.244 , pp. 559-564
    • Meinhardt, B.1    Stachs, O.2    Stave, J.3    Beck, R.4    Guthoff, R.5
  • 12
    • 45249107234 scopus 로고    scopus 로고
    • Comparability and intra-/interobserver reliability of anterior chamber depth measurements with the Pentacam and IOLMaster
    • Savant V, Chavan R, Pushpoth S, Ilango B. Comparability and intra-/interobserver reliability of anterior chamber depth measurements with the Pentacam and IOLMaster. J Refract Surg 2008 24 : 615 618.
    • (2008) J Refract Surg , vol.24 , pp. 615-618
    • Savant, V.1    Chavan, R.2    Pushpoth, S.3    Ilango, B.4
  • 13
    • 1942446238 scopus 로고    scopus 로고
    • Possible errors in determining axial length changes during accommodation with the IOLMaster
    • Atchison DA, Smith G. Possible errors in determining axial length changes during accommodation with the IOLMaster. Optom Vis Sci 2004 81 : 282 285.
    • (2004) Optom Vis Sci , vol.81 , pp. 282-285
    • Atchison, D.A.1    Smith, G.2
  • 15
    • 0000004140 scopus 로고
    • Measurement in medicine: The analysis of method comparison studies
    • Altman D, Bland J. Measurement in medicine: the analysis of method comparison studies. The statistician 1983 32 : 307 317.
    • (1983) The Statistician , vol.32 , pp. 307-317
    • Altman, D.1    Bland, J.2
  • 16
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986 1 (8476 307 310.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.1    Altman, D.2
  • 17
    • 0028791287 scopus 로고
    • Comparing method of measurement: Why plotting difference against standard method is misleading
    • Bland JM, Altman DG. Comparing method of measurement: why plotting difference against standard method is misleading. Lancet 1995 346 (8982 1085 1087.
    • (1995) Lancet , vol.346 , Issue.8982 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 33847139692 scopus 로고    scopus 로고
    • Assessment and reproducibility of anterior chamber depth measurement with anterior segment optical coherence tomography compared with immersion ultrasonography
    • Nemeth G, Vajas A, Tsorbatzoglou A, Kolozsvari B, Modis LJ, Berta A. Assessment and reproducibility of anterior chamber depth measurement with anterior segment optical coherence tomography compared with immersion ultrasonography. J Cataract Refract Surg 2007 33 : 443 447.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 443-447
    • Nemeth, G.1    Vajas, A.2    Tsorbatzoglou, A.3    Kolozsvari, B.4    Modis, L.J.5    Berta, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.