메뉴 건너뛰기




Volumn 81, Issue 4, 2004, Pages 283-286

Possible Errors in Determining Axial Length Changes during Accommodation with the IOLMaster

Author keywords

Axial length; Gradient index; Partial coherence interference; Schematic eye; Zeiss IOLMaster

Indexed keywords

ERROR ANALYSIS; INTERFEROMETRY; LENSES; REFRACTIVE INDEX; TOMOGRAPHY;

EID: 1942446238     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/00006324-200404000-00015     Document Type: Article
Times cited : (49)

References (12)
  • 1
    • 0026101781 scopus 로고
    • Optical measurement of the axial eye length by laser Doppler interferometry
    • Hitzenberger CK. Optical measurement of the axial eye length by laser Doppler interferometry. Invest Ophthalmol Vis Sci 1991;32:616-24.
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 616-624
    • Hitzenberger, C.K.1
  • 3
    • 0034747904 scopus 로고    scopus 로고
    • The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster
    • Lam AK, Chan R, Pang PC. The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster. Ophthalmic Physiol Opt 2001;21:477-83.
    • (2001) Ophthalmic Physiol Opt , vol.21 , pp. 477-483
    • Lam, A.K.1    Chan, R.2    Pang, P.C.3
  • 4
    • 0035205647 scopus 로고    scopus 로고
    • Reproducibility of optical biometry using partial coherence interferometry: Intraobserver and interobserver reliability
    • Vogel A, Dick HB, Krummenauer F. Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability. J Cataract Refract Surg 2001;27:1961-8.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1961-1968
    • Vogel, A.1    Dick, H.B.2    Krummenauer, F.3
  • 6
    • 0742305077 scopus 로고    scopus 로고
    • Ocular component measurement using the Zeiss IOLMaster
    • Sheng H, Bottjer CA, Bullimore MA. Ocular component measurement using the Zeiss IOLMaster. Optom Vis Sci 2004;81:27-34.
    • (2004) Optom Vis Sci , vol.81 , pp. 27-34
    • Sheng, H.1    Bottjer, C.A.2    Bullimore, M.A.3
  • 7
    • 0033805274 scopus 로고    scopus 로고
    • Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis
    • Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol 2000;238:765-73.
    • (2000) Graefes Arch Clin Exp Ophthalmol , vol.238 , pp. 765-773
    • Haigis, W.1    Lege, B.2    Miller, N.3    Schneider, B.4
  • 8
    • 1942467502 scopus 로고    scopus 로고
    • Effect of accommodation on axial length measurement in optical coherence biometry
    • 44 ARVO E-Abstract 4080
    • Uozato H, Shimizu K, Minei R, Suzuki H. Effect of accommodation on axial length measurement in optical coherence biometry. Invest Ophthalmol Vis Sci 2003;44 ARVO E-Abstract 4080.
    • (2003) Invest Ophthalmol Vis Sci
    • Uozato, H.1    Shimizu, K.2    Minei, R.3    Suzuki, H.4
  • 9
    • 0030863198 scopus 로고    scopus 로고
    • Biometric investigation of changes in the anterior eye segment during accommodation
    • Drexler W, Baumgartner A, Findl O, Hitzenberger CK, Fercher AF. Biometric investigation of changes in the anterior eye segment during accommodation. Vision Res 1997;37:2789-800.
    • (1997) Vision Res , vol.37 , pp. 2789-2800
    • Drexler, W.1    Baumgartner, A.2    Findl, O.3    Hitzenberger, C.K.4    Fercher, A.F.5
  • 10
    • 0004930027 scopus 로고
    • Appendices II and IV
    • Southall JP, ed. Rochester, NY: Optical Society of America
    • Gullstrand A. Appendices II and IV. In: Southall JP, ed. Helmholtz's Treatise on Physiological Optics, Vol. 1. Rochester, NY: Optical Society of America, 1924.
    • (1924) Helmholtz's Treatise on Physiological Optics , vol.1
    • Gullstrand, A.1
  • 11
    • 0036072966 scopus 로고    scopus 로고
    • Age-related changes in refractive index distribution and power of the human lens as measured by magnetic resonance micro-imaging in vitro
    • Moffat BA, Atchison DA, Pope JM. Age-related changes in refractive index distribution and power of the human lens as measured by magnetic resonance micro-imaging in vitro. Vision Res 2002;42:1683-93.
    • (2002) Vision Res , vol.42 , pp. 1683-1693
    • Moffat, B.A.1    Atchison, D.A.2    Pope, J.M.3
  • 12
    • 0022105223 scopus 로고
    • Accommodation-dependent model of the human eye with aspherics
    • Navarro R, Santamaría J, Bescós J. Accommodation-dependent model of the human eye with aspherics. J Opt Soc Am (A) 1985;2:1273-81.
    • (1985) J Opt Soc Am (A) , vol.2 , pp. 1273-1281
    • Navarro, R.1    Santamaría, J.2    Bescós, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.