Comparison of the Tono-Pen and Goldman tonometer for measuring intraocular pressure in patients with glaucoma

Author keywords

Comparison; Intraocular pressure; Tono Pen

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; BIOMEDICAL TECHNOLOGY ASSESSMENT; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORRELATION COEFFICIENT; FEMALE; GLAUCOMA; HUMAN; INTRAOCULAR PRESSURE; MAJOR CLINICAL STUDY; MALE; PRESSURE MEASUREMENT; PROSPECTIVE STUDY; RELIABILITY; TONOMETER;

EID: 11344262810     PISSN: 14426404     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1442-9071.2004.00907.x     Document Type: Article
Times cited : (44)

References (19)
  • 1
    • 0027291601 scopus 로고
    • Sources of error with the use of the Goldmann-type tonometers
    • Whitacre MM, Stein R. Sources of error with the use of the Goldmann-type tonometers. Surv Ophthalmol 1993; 38: 1-30.
    • (1993) Surv. Ophthalmol. , vol.38 , pp. 1-30
    • Whitacre, M.M.1    Stein, R.2
  • 3
    • 0023470773 scopus 로고
    • Clinical evaluation of the Oculab Tono-Pen to the Goldmann applanation tonometer
    • Kao S, Lichter P, Bergstrom T et al. Clinical evaluation of the Oculab Tono-Pen to the Goldmann applanation tonometer. Ophthalmology 1987; 94: 1541-4.
    • (1987) Ophthalmology , vol.94 , pp. 1541-1544
    • Kao, S.1    Lichter, P.2    Bergstrom, T.3
  • 4
    • 11344274239 scopus 로고
    • Clinical evaluation of the Oculab Tono-Pen
    • Minkler D, Baerveldt G, Huer D et al. Clinical evaluation of the Oculab Tono-Pen. Am J Ophthalmol 1990; 109: 716-20.
    • (1990) Am. J. Ophthalmol. , vol.109 , pp. 716-720
    • Minkler, D.1    Baerveldt, G.2    Huer, D.3
  • 5
    • 0031703801 scopus 로고    scopus 로고
    • Tonometry in adults and chidren. A manometric of pneumatonometry, applanation and Tono-Pen in vitro and in vivo
    • Eisenberg DL, Sherman BG, McKeown CA, Schuman JS. Tonometry in adults and chidren. A manometric of pneumatonometry, applanation and Tono-Pen in vitro and in vivo. Ophthalmology 1998; 105: 1173-81.
    • (1998) Ophthalmology , vol.105 , pp. 1173-1181
    • Eisenberg, D.L.1    Sherman, B.G.2    McKeown, C.A.3    Schuman, J.S.4
  • 6
    • 0024517249 scopus 로고
    • An evaluation of the Tono-Pen for the measurement of diurnal intraocular pressure
    • Farrar S, Miller K, Shields B et al. An evaluation of the Tono-Pen for the measurement of diurnal intraocular pressure. Am J Ophthalmol 1989; 107: 411-16.
    • (1989) Am. J. Ophthalmol. , vol.107 , pp. 411-416
    • Farrar, S.1    Miller, K.2    Shields, B.3
  • 7
    • 0026474107 scopus 로고
    • Tonometry comparison: Goldmann versus Tono-Pen
    • Kooner K, Cooksey J, Barron J et al. Tonometry comparison: Goldmann versus Tono-Pen. Ann Ophthalmol 1992; 24 29-36.
    • (1992) Ann. Ophthalmol. , vol.24 , pp. 29-36
    • Kooner, K.1    Cooksey, J.2    Barron, J.3
  • 8
    • 0026733030 scopus 로고
    • Tono-Pen tonometry in normal and post-keratoplasty eyes
    • Geyer O, Mayron Y, Loewenstein A et al. Tono-Pen tonometry in normal and post-keratoplasty eyes. Br J Ophthalmol 1992; 76: 538-40.
    • (1992) Br. J. Ophthalmol. , vol.76 , pp. 538-540
    • Geyer, O.1    Mayron, Y.2    Loewenstein, A.3
  • 9
    • 0028590107 scopus 로고
    • Clinical comparison of the Proton and Tono-Pen tonometers with the Goldmann applanation tonometer
    • Midelfart A, Wigers A. Clinical comparison of the Proton and Tono-Pen tonometers with the Goldmann applanation tonometer. Br J Ophthalmol 1994; 78: 895-8.
    • (1994) Br. J. Ophthalmol. , vol.78 , pp. 895-898
    • Midelfart, A.1    Wigers, A.2
  • 10
    • 0023893222 scopus 로고
    • Comparison of the Tono-Pen to the Goldmann applanation tonometer
    • Frenkel R, Hong Y, Shin D. Comparison of the Tono-Pen to the Goldmann applanation tonometer. Arch Ophthalmol 1988; 106: 750-3.
    • (1988) Arch. Ophthalmol. , vol.106 , pp. 750-753
    • Frenkel, R.1    Hong, Y.2    Shin, D.3
  • 12
    • 0000004140 scopus 로고
    • Measurement in medicine. The analysis of method comparison studies
    • Altman DG, Bland JM. Measurement in medicine. The analysis of method comparison studies. Statistician 1983; 32: 307-47.
    • (1983) Statistician , vol.32 , pp. 307-347
    • Altman, D.G.1    Bland, J.M.2
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 15
    • 0014314194 scopus 로고
    • Repeated applanation tonometry
    • Moses RA, Liu C. Repeated applanation tonometry. Am J Ophthalmol 1968; 66: 89-91.
    • (1968) Am. J. Ophthalmol. , vol.66 , pp. 89-91
    • Moses, R.A.1    Liu, C.2
  • 16
    • 0027411154 scopus 로고
    • Tonometry in the general practice setting (1): Tono-Pen compared to Goldmann applanation tonometry
    • Christoffersen T, Fors T, Ringberg U, Holtedahl K. Tonometry in the general practice setting (1): Tono-Pen compared to Goldmann applanation tonometry. Acta Ophthalmol 1993; 71: 103-8.
    • (1993) Acta Ophthalmol. , vol.71 , pp. 103-108
    • Christoffersen, T.1    Fors, T.2    Ringberg, U.3    Holtedahl, K.4
  • 17
    • 0000021294 scopus 로고
    • The clinical application of the Goldmann applanation tonometer
    • Schmidt TAF. The clinical application of the Goldmann applanation tonometer. Am J Ophthalmol 1960; 49: 967-78.
    • (1960) Am. J. Ophthalmol. , vol.49 , pp. 967-978
    • Schmidt, T.A.F.1
  • 18
    • 0002523438 scopus 로고
    • Applanation tonometry
    • FW Newell, ed. Glaucoma. New York: Josiah Mary Jr Foundation
    • Goldmann H. Applanation tonometry. In: FW Newell, ed. Glaucoma. Transactions of the Second Conference. New York: Josiah Mary Jr Foundation, 1957; 167-220.
    • (1957) Transactions of the Second Conference , pp. 167-220
    • Goldmann, H.1
  • 19
    • 0036235038 scopus 로고    scopus 로고
    • Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen
    • Bhan A, Browning A, Shah S et al. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Invest Ophthalmol Vis Sci 2002; 43: 1389-92.
    • (2002) Invest. Ophthalmol. Vis. Sci. , vol.43 , pp. 1389-1392
    • Bhan, A.1    Browning, A.2    Shah, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.