-
2
-
-
0015076420
-
Fracture reduction using a biodegradable material, polylactic acid
-
D.E. Cutright, E.E. Hunsuck, and J.D. Beasley Fracture reduction using a biodegradable material, polylactic acid J Oral Surg 9 1971 393 397
-
(1971)
J Oral Surg
, vol.9
, pp. 393-397
-
-
Cutright, D.E.1
Hunsuck, E.E.2
Beasley, J.D.3
-
3
-
-
0015335779
-
A biodegradable intraosseous appliance in the treatment of mandibular fractures
-
L. Getter, D.E. Cutright, S.N. Bhaskar, and J.K. Augsburg A biodegradable intraosseous appliance in the treatment of mandibular fractures J Oral Surg 30 1972 344 348
-
(1972)
J Oral Surg
, vol.30
, pp. 344-348
-
-
Getter, L.1
Cutright, D.E.2
Bhaskar, S.N.3
Augsburg, J.K.4
-
4
-
-
0015252289
-
The repair of fractures of the orbital floor using biodegradable polylactic acid
-
D.E. Cutright, and E.E. Hunsuck The repair of fractures of the orbital floor using biodegradable polylactic acid Oral Surg Oral Med Oral Pathol 33 1972 28 34
-
(1972)
Oral Surg Oral Med Oral Pathol
, vol.33
, pp. 28-34
-
-
Cutright, D.E.1
Hunsuck, E.E.2
-
5
-
-
0022064045
-
Resorbable materials for osteosynthesis. An experimental animal study
-
R. Ewers, and H. Forster Resorbable materials for osteosynthesis. An experimental animal study Dtsch Z Mund Kiefer Gesichtschir 9 1985 196 201
-
(1985)
Dtsch Z Mund Kiefer Gesichtschir
, vol.9
, pp. 196-201
-
-
Ewers, R.1
Forster, H.2
-
6
-
-
0021930711
-
Experimental and clinical results of new advances in the treatment of facial trauma
-
R. Ewers, and F. Härle Experimental and clinical results of new advances in the treatment of facial trauma Plast Reconstr Surg 75 1985 25 31
-
(1985)
Plast Reconstr Surg
, vol.75
, pp. 25-31
-
-
Ewers, R.1
Härle, F.2
-
7
-
-
0023205611
-
Resorbable poly(L-lactide) plates and screws for the fixation of zygomatic fractures
-
R.R. Bos, G. Boering, F.R. Rozema, and J.W. Leenslag Resorbable poly(L-lactide) plates and screws for the fixation of zygomatic fractures J Oral Maxillofac Surg 45 1987 751 753
-
(1987)
J Oral Maxillofac Surg
, vol.45
, pp. 751-753
-
-
Bos, R.R.1
Boering, G.2
Rozema, F.R.3
Leenslag, J.W.4
-
8
-
-
0028343026
-
Sagittal ramus osteotomies fixed with biodegradable screws: A preliminary report
-
R. Suuronen, P. Laine, T. Pohjonen, and C. Lindqvist Sagittal ramus osteotomies fixed with biodegradable screws: a preliminary report J Oral Maxillofac Surg 52 1994 715 720
-
(1994)
J Oral Maxillofac Surg
, vol.52
, pp. 715-720
-
-
Suuronen, R.1
Laine, P.2
Pohjonen, T.3
Lindqvist, C.4
-
10
-
-
0030902915
-
Potential for guided bone regeneration and bone graft fixation with resorbable membranes in pediatric craniofacial surgery
-
B.L. Eppley Potential for guided bone regeneration and bone graft fixation with resorbable membranes in pediatric craniofacial surgery J Craniofac Surg 8 1997 127 128
-
(1997)
J Craniofac Surg
, vol.8
, pp. 127-128
-
-
Eppley, B.L.1
-
11
-
-
0030926022
-
Resorbable plate fixation in pediatric craniofacial surgery
-
B.L. Eppley, A.M. Sadove, and R.J. Havlik Resorbable plate fixation in pediatric craniofacial surgery Plast Reconstr Surg 100 1997 1 7
-
(1997)
Plast Reconstr Surg
, vol.100
, pp. 1-7
-
-
Eppley, B.L.1
Sadove, A.M.2
Havlik, R.J.3
-
12
-
-
0032185145
-
Fixation of zygomatic fractures with a new biodegradable copolymer osteosynthesis system. Preliminary results
-
G. Enislidis, S. Pichorner, F. Lambert, A. Wagner, F. Kainberger, and M. Kautzky Fixation of zygomatic fractures with a new biodegradable copolymer osteosynthesis system. Preliminary results Int J Oral Maxillofac Surg 27 1998 352 355
-
(1998)
Int J Oral Maxillofac Surg
, vol.27
, pp. 352-355
-
-
Enislidis, G.1
Pichorner, S.2
Lambert, F.3
Wagner, A.4
Kainberger, F.5
Kautzky, M.6
-
13
-
-
0032427494
-
Biodegradable self-reinforced poly-L/DL-lactide plates and screws in bimaxillary orthognathic surgery: Short-term skeletal stability and material related failures
-
P.E. Haers, and H.F. Sailer Biodegradable self-reinforced poly-L/DL-lactide plates and screws in bimaxillary orthognathic surgery: short-term skeletal stability and material related failures J Craniomaxillofac Surg 26 1998 363 372
-
(1998)
J Craniomaxillofac Surg
, vol.26
, pp. 363-372
-
-
Haers, P.E.1
Sailer, H.F.2
-
14
-
-
0031780545
-
Biodegradable polylactide plates and screws in orthognathic surgery: Technical note
-
P.E. Haers, R. Suuronen, C. Lindqvist, and H. Sailer Biodegradable polylactide plates and screws in orthognathic surgery: technical note J Craniomaxillofac Surg 26 1998 87 91
-
(1998)
J Craniomaxillofac Surg
, vol.26
, pp. 87-91
-
-
Haers, P.E.1
Suuronen, R.2
Lindqvist, C.3
Sailer, H.4
-
15
-
-
0031989566
-
Skeletal stability following mandibular advancement and rigid fixation with polylactide biodegradable screws
-
I. Kallela, P. Laine, R. Suuronen, T. Iizuka, S. Pirinen, and C. Lindqvist Skeletal stability following mandibular advancement and rigid fixation with polylactide biodegradable screws Int J Oral Maxillofac Surg 27 1998 3 8
-
(1998)
Int J Oral Maxillofac Surg
, vol.27
, pp. 3-8
-
-
Kallela, I.1
Laine, P.2
Suuronen, R.3
Iizuka, T.4
Pirinen, S.5
Lindqvist, C.6
-
16
-
-
0033023171
-
Lag-screw fixation of anterior mandibular fractures using biodegradable polylactide screws: A preliminary report
-
I. Kallela, T. Iizuka, A. Salo, and C. Lindquist Lag-screw fixation of anterior mandibular fractures using biodegradable polylactide screws: a preliminary report J Oral Maxillofac Surg 57 1999 113 118
-
(1999)
J Oral Maxillofac Surg
, vol.57
, pp. 113-118
-
-
Kallela, I.1
Iizuka, T.2
Salo, A.3
Lindquist, C.4
-
17
-
-
0033137307
-
Osteotomy site healing following mandibular sagittal split osteotomy and rigid fixation with polylactide biodegradable screws
-
I. Kallela, P. Laine, R. Suuronen, P. Ranta, T. Iizuka, and C. Lindqvist Osteotomy site healing following mandibular sagittal split osteotomy and rigid fixation with polylactide biodegradable screws Int J Oral Maxillofac Surg 28 1999 166 170
-
(1999)
Int J Oral Maxillofac Surg
, vol.28
, pp. 166-170
-
-
Kallela, I.1
Laine, P.2
Suuronen, R.3
Ranta, P.4
Iizuka, T.5
Lindqvist, C.6
-
18
-
-
0034530082
-
A resorbable and rapid method for maxillomandibular fixation in pediatric mandible fractures
-
B.L. Eppley A resorbable and rapid method for maxillomandibular fixation in pediatric mandible fractures J Craniofac Surg 11 2000 236 238
-
(2000)
J Craniofac Surg
, vol.11
, pp. 236-238
-
-
Eppley, B.L.1
-
19
-
-
0034488693
-
Bioresorbable fixation for congenital pediatric craniofacial surgery: A 2-year follow-up
-
S.N. Kurpad, J.A. Goldstein, and A.R. Cohen Bioresorbable fixation for congenital pediatric craniofacial surgery: a 2-year follow-up Pediatr Neurosurg 33 2000 306 310
-
(2000)
Pediatr Neurosurg
, vol.33
, pp. 306-310
-
-
Kurpad, S.N.1
Goldstein, J.A.2
Cohen, A.R.3
-
20
-
-
0034813217
-
Use of self-reinforced polylactide osteosynthesis devices in craniofacial surgery: A long-term follow-up study
-
W. Serlo, O.I. Kaarela, H.H. Peltoniemi, J. Merikanto, N.A. Ashammakhi, and K. Lassila Use of self-reinforced polylactide osteosynthesis devices in craniofacial surgery: a long-term follow-up study Scand J Plast Reconstr Surg Hand Surg 35 2001 285 292
-
(2001)
Scand J Plast Reconstr Surg Hand Surg
, vol.35
, pp. 285-292
-
-
Serlo, W.1
Kaarela, O.I.2
Peltoniemi, H.H.3
Merikanto, J.4
Ashammakhi, N.A.5
Lassila, K.6
-
21
-
-
0036141099
-
The use of self-reinforced biodegradable bone plates and screws in orthognathic surgery
-
T.A. Turvey, R.B. Bell, T.J. Tejera, and W.R. Proffit The use of self-reinforced biodegradable bone plates and screws in orthognathic surgery J Oral Maxillofac Surg 60 2002 59 65
-
(2002)
J Oral Maxillofac Surg
, vol.60
, pp. 59-65
-
-
Turvey, T.A.1
Bell, R.B.2
Tejera, T.J.3
Proffit, W.R.4
-
22
-
-
0036287227
-
Treatment of mandible fractures using bioabsorbable plates
-
Y.K. Kim, and S.G. Kim Treatment of mandible fractures using bioabsorbable plates Plast Reconstr Surg 110 2002 25 31
-
(2002)
Plast Reconstr Surg
, vol.110
, pp. 25-31
-
-
Kim, Y.K.1
Kim, S.G.2
-
23
-
-
0036716091
-
Fixation of mandibular fractures with biodegradable plates and screws
-
K.C. Yerit, G. Enislidis, C. Schopper, D. Turhani, F. Wanschitz, and A. Wagner Fixation of mandibular fractures with biodegradable plates and screws Oral Surg Oral Med Oral Pathol Oral Radiol Endod 94 2002 294 300
-
(2002)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.94
, pp. 294-300
-
-
Yerit, K.C.1
Enislidis, G.2
Schopper, C.3
Turhani, D.4
Wanschitz, F.5
Wagner, A.6
-
24
-
-
1542269131
-
Self-reinforced bioresorbable poly-L/DL-Lactide [SR-P(L/DL)LA] 70/30 miniplates and miniscrews are reliable for fixation of anterior mandibular fractures: A pilot study
-
L. Ylikontiola, K. Sundqvuist, G.K. Sandor, P. Törmälä, and N. Ashammakhi Self-reinforced bioresorbable poly-L/DL-Lactide [SR-P(L/DL)LA] 70/30 miniplates and miniscrews are reliable for fixation of anterior mandibular fractures: a pilot study Oral Surg Oral Med Oral Pathol Oral Radiol Endod 97 2004 312 317
-
(2004)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.97
, pp. 312-317
-
-
Ylikontiola, L.1
Sundqvuist, K.2
Sandor, G.K.3
Törmälä, P.4
Ashammakhi, N.5
-
25
-
-
4143065625
-
Craniofacial reconstruction with a fast resorbing polymer: A 6- to 12-month clinical follow-up review
-
S.R. Cohen, R.E. Holmes, H.S. Meltzer, M.L. Levy, and M.Z. Beckett Craniofacial reconstruction with a fast resorbing polymer: a 6- to 12-month clinical follow-up review Neurosurg Focus 16 2004 E12
-
(2004)
Neurosurg Focus
, vol.16
, pp. 12
-
-
Cohen, S.R.1
Holmes, R.E.2
Meltzer, H.S.3
Levy, M.L.4
Beckett, M.Z.5
-
26
-
-
2442569830
-
Fractures of the mandible in children under the age of six years
-
W.D. MacLennan Fractures of the mandible in children under the age of six years Br J Surg 9 1956 125 128
-
(1956)
Br J Surg
, vol.9
, pp. 125-128
-
-
MacLennan, W.D.1
-
27
-
-
0014320371
-
Fractures of the facial skeleton in children
-
N.L. Rowe Fractures of the facial skeleton in children J Oral Surg 26 1968 505 515
-
(1968)
J Oral Surg
, vol.26
, pp. 505-515
-
-
Rowe, N.L.1
-
28
-
-
0017618592
-
Facial fractures in children: An analysis of 122 fractures in 109 patients
-
L.B. Kaban, J.B. Mulliken, and J.E. Murry Facial fractures in children: an analysis of 122 fractures in 109 patients Plast Reconstr Surg 59 1977 15 20
-
(1977)
Plast Reconstr Surg
, vol.59
, pp. 15-20
-
-
Kaban, L.B.1
Mulliken, J.B.2
Murry, J.E.3
-
29
-
-
0027217215
-
Pediatric facial fractures: Evolving patterns of treatment
-
J.C. Posnick, M. Wells, and G. Pron Pediatric facial fractures: evolving patterns of treatment J Oral Maxillofac Surg 51 1993 836 844
-
(1993)
J Oral Maxillofac Surg
, vol.51
, pp. 836-844
-
-
Posnick, J.C.1
Wells, M.2
Pron, G.3
-
30
-
-
0027371553
-
Comparison of CT imaging artifacts from craniomaxillofacial internal fixation devices
-
T.G. Fiala, R.A. Novelline, and M.J. Yaremchuk Comparison of CT imaging artifacts from craniomaxillofacial internal fixation devices Plast Reconstr Surg 92 1993 1227 1232
-
(1993)
Plast Reconstr Surg
, vol.92
, pp. 1227-1232
-
-
Fiala, T.G.1
Novelline, R.A.2
Yaremchuk, M.J.3
-
31
-
-
0027417781
-
Ultrastructural findings in soft tissues adjacent to titanium plates used in jaw fracture treatment
-
H. Schliephake, H. Lehmann, U. Kunz, and R. Schmelzeisen Ultrastructural findings in soft tissues adjacent to titanium plates used in jaw fracture treatment Int J Oral Maxillofac Surg 22 1993 20 25
-
(1993)
Int J Oral Maxillofac Surg
, vol.22
, pp. 20-25
-
-
Schliephake, H.1
Lehmann, H.2
Kunz, U.3
Schmelzeisen, R.4
-
32
-
-
0027248481
-
Should titanium miniplates be removed after bone healing is complete?
-
A. Rosenberg, K.W. Gratz, and H.F. Sailer Should titanium miniplates be removed after bone healing is complete? Int J Oral Maxillofac Surg 22 1993 185 188
-
(1993)
Int J Oral Maxillofac Surg
, vol.22
, pp. 185-188
-
-
Rosenberg, A.1
Gratz, K.W.2
Sailer, H.F.3
-
33
-
-
0028032268
-
Cortical porosis under plates. Reaction to unloading or to necrosis?
-
H. Uhthoff, D. Boisvert, and M. Finnegan Cortical porosis under plates. Reaction to unloading or to necrosis? J Bone Joint Surg 76 1994 1507 1512
-
(1994)
J Bone Joint Surg
, vol.76
, pp. 1507-1512
-
-
Uhthoff, H.1
Boisvert, D.2
Finnegan, M.3
-
34
-
-
0028215040
-
Comparison of artifact from craniomaxillfacial internal fixation devices: Magnetic resonance imaging
-
T.G. Fiala, K.T. Page, T.L. Davis, T.A. Campbell, B.R. Rosen, and M.J. Yaremchuk Comparison of artifact from craniomaxillfacial internal fixation devices: magnetic resonance imaging Plast Reconstr Surg 93 1994 725 731
-
(1994)
Plast Reconstr Surg
, vol.93
, pp. 725-731
-
-
Fiala, T.G.1
Page, K.T.2
Davis, T.L.3
Campbell, T.A.4
Rosen, B.R.5
Yaremchuk, M.J.6
-
35
-
-
0029029786
-
Passive and active intracranial translocation of osteosynthesis plates in adolescent minipigs
-
J.F. Hönig, H.A. Merten, and H.G. Luhr Passive and active intracranial translocation of osteosynthesis plates in adolescent minipigs J Craniofac Surg 6 1995 292 298
-
(1995)
J Craniofac Surg
, vol.6
, pp. 292-298
-
-
Hönig, J.F.1
Merten, H.A.2
Luhr, H.G.3
-
36
-
-
0029056152
-
"false" migration of rigid fixation appliances in pediatric craniofacial surgery
-
F.A. Papay, S. Hardy, L. Morales, M. Walker, and D. Enlow "False" migration of rigid fixation appliances in pediatric craniofacial surgery J Craniofac Surg 6 1995 309 313
-
(1995)
J Craniofac Surg
, vol.6
, pp. 309-313
-
-
Papay, F.A.1
Hardy, S.2
Morales, L.3
Walker, M.4
Enlow, D.5
-
37
-
-
0029394777
-
Bone changes after experimental osteotomies fixed with absorbable self-reinforced poly-L-lactide screws or metallic screws studied by plain radiographs, quantitive computed tomography, and magnetic resonance imaging
-
J. Viljanen, J. Kinnunen, S. Bandestam, A. Majola, P. Rokkanen, and P. Tormälä Bone changes after experimental osteotomies fixed with absorbable self-reinforced poly-L-lactide screws or metallic screws studied by plain radiographs, quantitive computed tomography, and magnetic resonance imaging Biomaterials 16 1995 1353 1358
-
(1995)
Biomaterials
, vol.16
, pp. 1353-1358
-
-
Viljanen, J.1
Kinnunen, J.2
Bandestam, S.3
Majola, A.4
Rokkanen, P.5
Tormälä, P.6
-
38
-
-
0030932222
-
Detection of titanium in human tissues after craniofacial surgery
-
D.S. Jorgenson, M.H. Mayer, R.G. Ellenbogen, J.A. Centeno, F.B. Johnson, and F.G. Mullick Detection of titanium in human tissues after craniofacial surgery Plast Reconstr Surg 99 1997 976 979
-
(1997)
Plast Reconstr Surg
, vol.99
, pp. 976-979
-
-
Jorgenson, D.S.1
Mayer, M.H.2
Ellenbogen, R.G.3
Centeno, J.A.4
Johnson, F.B.5
Mullick, F.G.6
-
40
-
-
0026549107
-
Biodegradable self-reinforced composite materials: Manufacturing structure and mechanical properties
-
P. Törmälä Biodegradable self-reinforced composite materials: manufacturing structure and mechanical properties Clin Mater 10 1992 29 34
-
(1992)
Clin Mater
, vol.10
, pp. 29-34
-
-
Törmälä, P.1
-
41
-
-
0025334647
-
Foreign body reactions to fracture fixation implants of biodegradable synthetic polymers
-
O. Böstman, E. Hirvensalo, J. Mäkinen, and P. Rokkanen Foreign body reactions to fracture fixation implants of biodegradable synthetic polymers J Bone Joint Surg (Br) 72 1990 592 596
-
(1990)
J Bone Joint Surg (Br)
, vol.72
, pp. 592-596
-
-
Böstman, O.1
Hirvensalo, E.2
Mäkinen, J.3
Rokkanen, P.4
-
42
-
-
0026518970
-
Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures
-
O. Böstman Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures Clin Orthop 278 1992 193 199
-
(1992)
Clin Orthop
, vol.278
, pp. 193-199
-
-
Böstman, O.1
-
43
-
-
0028878553
-
Late degradation tissue response to poly(L-lactide) bone plates and screws
-
J.E. Bergsma, W.C. de Bruijn, F.R. Rozema, R.R. Bos, and G. Boering Late degradation tissue response to poly(L-lactide) bone plates and screws Biomaterials 16 1995 25 31
-
(1995)
Biomaterials
, vol.16
, pp. 25-31
-
-
Bergsma, J.E.1
De Bruijn, W.C.2
Rozema, F.R.3
Bos, R.R.4
Boering, G.5
-
44
-
-
0016215346
-
Mandibular growth and remodelling processes after condylar fracture. a longitudinal roentgencephalometric study
-
K. Lund Mandibular growth and remodelling processes after condylar fracture. A longitudinal roentgencephalometric study Acta Odontol Scand Suppl 32 1974 3 117
-
(1974)
Acta Odontol Scand Suppl
, vol.32
, pp. 3-117
-
-
Lund, K.1
|