메뉴 건너뛰기




Volumn 42, Issue 14, 2009, Pages 2301-2306

Accurate intraocular pressure prediction from applanation response data using genetic algorithm and neural networks

Author keywords

Central corneal thickness; Cornea; Finite element simulation; Genetic algorithm; Goldmann applanation tonometry; Intraocular pressure; Neural networks

Indexed keywords

CENTRAL CORNEAL THICKNESS; CORNEA; FINITE ELEMENT SIMULATION; GOLDMANN APPLANATION TONOMETRY; INTRAOCULAR PRESSURE;

EID: 70349566395     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2009.06.020     Document Type: Article
Times cited : (9)

References (16)
  • 1
    • 0036235038 scopus 로고    scopus 로고
    • Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen
    • Bhan A., Browning A.C., Shah S., Hamilton R., Dave D., and Dua H.S. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Invest. Ophthalmol. Vis. Sci. 43 5 (2002) 1389-1392
    • (2002) Invest. Ophthalmol. Vis. Sci. , vol.43 , Issue.5 , pp. 1389-1392
    • Bhan, A.1    Browning, A.C.2    Shah, S.3    Hamilton, R.4    Dave, D.5    Dua, H.S.6
  • 2
    • 0030297968 scopus 로고    scopus 로고
    • Constitutive laws for biomechanical modeling of refractive surgery
    • Bryant M.R., and McDonnell P.J. Constitutive laws for biomechanical modeling of refractive surgery. J. Biomech. Eng. 118 4 (1996) 473-481
    • (1996) J. Biomech. Eng. , vol.118 , Issue.4 , pp. 473-481
    • Bryant, M.R.1    McDonnell, P.J.2
  • 3
    • 0016663381 scopus 로고
    • Applanation tonometry and central corneal thickness
    • Ehlers N., Bramsen T., and Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol. 53 1 (1975) 34-43
    • (1975) Acta Ophthalmol. , vol.53 , Issue.1 , pp. 34-43
    • Ehlers, N.1    Bramsen, T.2    Sperling, S.3
  • 4
    • 0004376035 scopus 로고
    • Pseudoelasticity of arteries and the choice of its mathematical expression
    • Fung Y.C., Fronek K., and Patitucci P. Pseudoelasticity of arteries and the choice of its mathematical expression. Am. J. Physiol. 237 5 (1979) H620-H631
    • (1979) Am. J. Physiol. , vol.237 , Issue.5
    • Fung, Y.C.1    Fronek, K.2    Patitucci, P.3
  • 8
    • 0017840770 scopus 로고
    • Increased corneal thickness simulating elevated intraocular-pressure
    • Johnson M., Kass M.A., Moses R.A., and Grodzki W.J. Increased corneal thickness simulating elevated intraocular-pressure. Arch. Ophthalmol. 96 4 (1978) 664-665
    • (1978) Arch. Ophthalmol. , vol.96 , Issue.4 , pp. 664-665
    • Johnson, M.1    Kass, M.A.2    Moses, R.A.3    Grodzki, W.J.4
  • 9
    • 58149123724 scopus 로고    scopus 로고
    • Correlations between corneal biomechanical properties measured with the ocular response analyzer and ICare rebound tonometry
    • Jorge J.M., Gonzalez-Meijome J.M., Queiros A., Fernandes P., and Parafita M.A. Correlations between corneal biomechanical properties measured with the ocular response analyzer and ICare rebound tonometry. J. Glaucoma 17 6 (2008) 442-448
    • (2008) J. Glaucoma , vol.17 , Issue.6 , pp. 442-448
    • Jorge, J.M.1    Gonzalez-Meijome, J.M.2    Queiros, A.3    Fernandes, P.4    Parafita, M.A.5
  • 11
    • 43749092192 scopus 로고    scopus 로고
    • Effect of cornea material stiffness on measured intraocular pressure
    • Kwon T.H., Ghaboussi J., Pecknold D.A., and Hashash Y.M. Effect of cornea material stiffness on measured intraocular pressure. J. Biomech. 41 8 (2008) 1707-1713
    • (2008) J. Biomech. , vol.41 , Issue.8 , pp. 1707-1713
    • Kwon, T.H.1    Ghaboussi, J.2    Pecknold, D.A.3    Hashash, Y.M.4
  • 12
    • 0031195491 scopus 로고    scopus 로고
    • Anatomically accurate, finite model eye for optical modeling
    • Liou H.L., and Brennan N.A. Anatomically accurate, finite model eye for optical modeling. J. Opt. Soc. Am. A Opt. Image Sci. Vision 14 8 (1997) 1684-1695
    • (1997) J. Opt. Soc. Am. A Opt. Image Sci. Vision , vol.14 , Issue.8 , pp. 1684-1695
    • Liou, H.L.1    Brennan, N.A.2
  • 13
    • 13844313434 scopus 로고    scopus 로고
    • Influence of corneal biomechanical properties on intraocular pressure measurement-quantitative analysis
    • Liu J., and Roberts C.J. Influence of corneal biomechanical properties on intraocular pressure measurement-quantitative analysis. J. Cataract Refractive Surg. 31 1 (2005) 146-155
    • (2005) J. Cataract Refractive Surg. , vol.31 , Issue.1 , pp. 146-155
    • Liu, J.1    Roberts, C.J.2
  • 15
    • 0030561003 scopus 로고    scopus 로고
    • An ultrasonic technique for the measurement of the elastic moduli of human cornea
    • Wang H.C., Prendiville P.L., McDonnell P.J., and Chang W.V. An ultrasonic technique for the measurement of the elastic moduli of human cornea. J. Biomech. 29 12 (1996) 1633-1636
    • (1996) J. Biomech. , vol.29 , Issue.12 , pp. 1633-1636
    • Wang, H.C.1    Prendiville, P.L.2    McDonnell, P.J.3    Chang, W.V.4
  • 16
    • 0027269723 scopus 로고
    • The effect of corneal thickness on applanation tonometry
    • Whitacre M.M., Stein R.A., and Hassanein K. The effect of corneal thickness on applanation tonometry. Am. J. Ophthalmol. 115 5 (1993) 592-596
    • (1993) Am. J. Ophthalmol. , vol.115 , Issue.5 , pp. 592-596
    • Whitacre, M.M.1    Stein, R.A.2    Hassanein, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.