메뉴 건너뛰기




Volumn 75, Issue 3, 2009, Pages 933-940

Quantitative Assessment of Image-Guided Radiotherapy for Paraspinal Tumors

Author keywords

IGRT; IMRT; Paraspinal tumors; Rigid registration

Indexed keywords

ANTERIOR POSTERIORS; CT SCAN; CT SCANNERS; HIGH DOSE; IGRT; IMAGE GUIDED RADIOTHERAPY; IMRT; INTENSITY-MODULATED RADIOTHERAPY; LUMBAR SPINES; MUTUAL INFORMATIONS; OPTIMAL REGISTRATION; PARASPINAL; PARASPINAL TUMORS; PATIENT POSITIONING; PATIENT SETUP; POSITIONING ERROR; QUANTITATIVE ASSESSMENTS; RIGID BODY; RIGID REGISTRATION; RIGID TRANSFORMATIONS; ROTATIONAL ERRORS; TARGET VOLUMES;

EID: 70349554315     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2009.04.010     Document Type: Article
Times cited : (14)

References (25)
  • 1
    • 56049083730 scopus 로고    scopus 로고
    • Spinal radiosurgery: Technology and clinical outcome
    • Avanzo M., and Romanelli P. Spinal radiosurgery: Technology and clinical outcome. Neurosurg Rev 32 (2009) 1-13
    • (2009) Neurosurg Rev , vol.32 , pp. 1-13
    • Avanzo, M.1    Romanelli, P.2
  • 2
    • 37249035632 scopus 로고    scopus 로고
    • Spinal radiosurgery for metastatic disease of the spine
    • Finn M.A., Vrionis F.D., and Schmidt M.H. Spinal radiosurgery for metastatic disease of the spine. Cancer Control 14 (2007) 405-411
    • (2007) Cancer Control , vol.14 , pp. 405-411
    • Finn, M.A.1    Vrionis, F.D.2    Schmidt, M.H.3
  • 3
  • 4
    • 43249095706 scopus 로고    scopus 로고
    • Conventionally-fractionated image-guided intensity modulated radiotherapy (IG-IMRT): A safe and effective treatment for cancer spinal metastasis
    • Gong Y., Wang J., and Bai S. Conventionally-fractionated image-guided intensity modulated radiotherapy (IG-IMRT): A safe and effective treatment for cancer spinal metastasis. Radiat Oncol 3 (2008) 11
    • (2008) Radiat Oncol , vol.3 , pp. 11
    • Gong, Y.1    Wang, J.2    Bai, S.3
  • 5
    • 34548426521 scopus 로고    scopus 로고
    • A review of image-guided intensity-modulated radiotherapy for spinal tumors
    • Yamada Y., Lovelock D.M., and Bilsky M.H. A review of image-guided intensity-modulated radiotherapy for spinal tumors. Neurosurgery 61 (2007) 226-235
    • (2007) Neurosurgery , vol.61 , pp. 226-235
    • Yamada, Y.1    Lovelock, D.M.2    Bilsky, M.H.3
  • 6
    • 34547605025 scopus 로고    scopus 로고
    • Craniospinal irradiation with spinal IMRT to improve target homogeneity
    • Pai Panandiker A., Ning H., and Likhacheva A. Craniospinal irradiation with spinal IMRT to improve target homogeneity. Int J Radiat Oncol Biol Phys 1 68 (2007) 1402-1409
    • (2007) Int J Radiat Oncol Biol Phys , vol.1 , Issue.68 , pp. 1402-1409
    • Pai Panandiker, A.1    Ning, H.2    Likhacheva, A.3
  • 7
    • 0141504154 scopus 로고    scopus 로고
    • Near simultaneous computed tomography image-guided stereotactic spinal radiotherapy: An emerging paradigm for achieving true stereotaxy
    • Shiu A.S., Chang E.L., Ye J.S., et al. Near simultaneous computed tomography image-guided stereotactic spinal radiotherapy: An emerging paradigm for achieving true stereotaxy. Int J Radiat Oncol Biol Phys 57 (2003) 605-613
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 605-613
    • Shiu, A.S.1    Chang, E.L.2    Ye, J.S.3
  • 8
    • 47149097983 scopus 로고    scopus 로고
    • Comparison of kilovoltage cone-beam computed tomography with megavoltage projection pairs for paraspinal radiosurgery patient alignment and position verification
    • Kriminski S.A., Lovelock D.M., and Seshan V.E. Comparison of kilovoltage cone-beam computed tomography with megavoltage projection pairs for paraspinal radiosurgery patient alignment and position verification. Int J Radiat Oncol Biol Phys 1 71 (2008) 1572-1580
    • (2008) Int J Radiat Oncol Biol Phys , vol.1 , Issue.71 , pp. 1572-1580
    • Kriminski, S.A.1    Lovelock, D.M.2    Seshan, V.E.3
  • 9
    • 0032817892 scopus 로고    scopus 로고
    • Noninvasive patient fixation for extracranial stereotactic radiotherapy
    • Lohr F., Debus J., Frank C., et al. Noninvasive patient fixation for extracranial stereotactic radiotherapy. Int J Radiat Oncol Biol Phys 45 (1999) 521-527
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 521-527
    • Lohr, F.1    Debus, J.2    Frank, C.3
  • 10
    • 84956857429 scopus 로고
    • Virtual simulation in radiotherapy planning
    • Bendl R., Hoess A., and Schlegel W. Virtual simulation in radiotherapy planning. Lect Notes Comput Sci 905 (1995) 287-292
    • (1995) Lect Notes Comput Sci , vol.905 , pp. 287-292
    • Bendl, R.1    Hoess, A.2    Schlegel, W.3
  • 11
    • 0035661024 scopus 로고    scopus 로고
    • A feasibility study of mutual information based setup error estimation for radiotherapy
    • Kim J., Fessler J.A., Lam K.L., et al. A feasibility study of mutual information based setup error estimation for radiotherapy. Med Phys 28 (2001) 2507-2517
    • (2001) Med Phys , vol.28 , pp. 2507-2517
    • Kim, J.1    Fessler, J.A.2    Lam, K.L.3
  • 12
    • 18744416987 scopus 로고    scopus 로고
    • Calculation of rotational setup error using the real-time tracking radiation therapy (RTRT) system and its application to the treatment of spinal schwannoma
    • Onimaru R., Shirato H., and Aoyama H. Calculation of rotational setup error using the real-time tracking radiation therapy (RTRT) system and its application to the treatment of spinal schwannoma. Int J Radiat Oncol Biol Phys 54 (2002) 939-947
    • (2002) Int J Radiat Oncol Biol Phys , vol.54 , pp. 939-947
    • Onimaru, R.1    Shirato, H.2    Aoyama, H.3
  • 13
    • 33646924615 scopus 로고    scopus 로고
    • Magnitude and clinical relevance of translational and rotational patient setup errors: A cone-beam CT Study
    • Guckenberger M., Meyer J., Vordermark D., et al. Magnitude and clinical relevance of translational and rotational patient setup errors: A cone-beam CT Study. Int J Radiat Oncol Biol Phys 65 (2006) 934-942
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 934-942
    • Guckenberger, M.1    Meyer, J.2    Vordermark, D.3
  • 14
    • 33847306482 scopus 로고    scopus 로고
    • Position accuracy of cone-beam computed tomography in combination with a hexapod robot treatment table
    • Meyer J., Wilbert J., and Beyer K. Position accuracy of cone-beam computed tomography in combination with a hexapod robot treatment table. Int J Radiat Oncol Biol Phys 67 (2007) 1220-1228
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1220-1228
    • Meyer, J.1    Wilbert, J.2    Beyer, K.3
  • 15
    • 24044543599 scopus 로고    scopus 로고
    • Real-time intra-fraction-motion tracking using the treatment couch: A feasibility study
    • D'Souza W.D., Naqvi S.A., and Yu C.X. Real-time intra-fraction-motion tracking using the treatment couch: A feasibility study. Phys Med Biol 50 (2005) 4021-4033
    • (2005) Phys Med Biol , vol.50 , pp. 4021-4033
    • D'Souza, W.D.1    Naqvi, S.A.2    Yu, C.X.3
  • 16
    • 27744457314 scopus 로고    scopus 로고
    • The need for rotational margins in intensity-modulated radiotherapy and a new method for planning target volume design
    • Langer M.P., Papiez L., Spirydovich S., et al. The need for rotational margins in intensity-modulated radiotherapy and a new method for planning target volume design. Int J Radiat Oncol Biol Phys 63 (2005) 1592-1603
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , pp. 1592-1603
    • Langer, M.P.1    Papiez, L.2    Spirydovich, S.3
  • 17
    • 0033041247 scopus 로고    scopus 로고
    • Inclusion of geometric uncertainties in the radiotherapy treatment planning by means of coverage probability
    • Stroom J.C., de Boer H.C., and Huizenga H. Inclusion of geometric uncertainties in the radiotherapy treatment planning by means of coverage probability. Int J Radiat Oncol Biol Phys 43 (1999) 905-919
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , pp. 905-919
    • Stroom, J.C.1    de Boer, H.C.2    Huizenga, H.3
  • 18
    • 0037359535 scopus 로고    scopus 로고
    • CT image-guided intensity-modulated therapy for paraspinal tumors using stereotactic immobilization
    • Yenice K.M., Lovelock D.M., Hunt M.A., et al. CT image-guided intensity-modulated therapy for paraspinal tumors using stereotactic immobilization. Int J Radiat Oncol Biol Phys 55 (2003) 583-593
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , pp. 583-593
    • Yenice, K.M.1    Lovelock, D.M.2    Hunt, M.A.3
  • 19
    • 34447106601 scopus 로고    scopus 로고
    • Precision required for dose-escalated treatment of spinal metastases and implications for image-guided radiation therapy (IGRT)
    • Guckenberger M., Meyer J., Wilbert J., et al. Precision required for dose-escalated treatment of spinal metastases and implications for image-guided radiation therapy (IGRT). Radiother Oncol 84 (2007) 56-63
    • (2007) Radiother Oncol , vol.84 , pp. 56-63
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3
  • 20
    • 34347269146 scopus 로고    scopus 로고
    • Precision of image-guided radiotherapy (IGRT) in six degrees of freedom and limitations in clinical practice
    • Guckenberger M., Meyer J., and Wilbert J. Precision of image-guided radiotherapy (IGRT) in six degrees of freedom and limitations in clinical practice. Strahlenther Oncol 183 (2007) 307-313
    • (2007) Strahlenther Oncol , vol.183 , pp. 307-313
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3
  • 21
    • 70349534929 scopus 로고    scopus 로고
    • Adaptive radiotherapy of head and neck cancer using automatic elastic matching of CT images (Abstr.)
    • Thieke C., Malsch U., Seeber A., et al. Adaptive radiotherapy of head and neck cancer using automatic elastic matching of CT images (Abstr.). Radiother Oncol 81 Suppl. 1 (2006) S27
    • (2006) Radiother Oncol , vol.81 , Issue.SUPPL. 1
    • Thieke, C.1    Malsch, U.2    Seeber, A.3
  • 22
    • 33748940252 scopus 로고    scopus 로고
    • Kilovoltage CT using a linac-CT scanner combination
    • Thieke C., Malsch U., and Schlegel W. Kilovoltage CT using a linac-CT scanner combination. Br J Radiol 79 (2006) 79-86
    • (2006) Br J Radiol , vol.79 , pp. 79-86
    • Thieke, C.1    Malsch, U.2    Schlegel, W.3
  • 23
    • 38149067615 scopus 로고    scopus 로고
    • A quantitative image quality comparison of four different image guided radiotherapy devices
    • Stützel J., Oelfke U., and Nill S. A quantitative image quality comparison of four different image guided radiotherapy devices. Radiother Oncol 86 (2008) 20-24
    • (2008) Radiother Oncol , vol.86 , pp. 20-24
    • Stützel, J.1    Oelfke, U.2    Nill, S.3
  • 25
    • 33748335530 scopus 로고    scopus 로고
    • Image-guided radiotherapy using megavoltage cone-beam computed tomography for treatment of paraspinous tumors in the presence of orthopedic hardware
    • Hansen E.K., Larson D.A., and Aubin M. Image-guided radiotherapy using megavoltage cone-beam computed tomography for treatment of paraspinous tumors in the presence of orthopedic hardware. Int J Radiat Oncol Biol Phys 66 (2006) 323-326
    • (2006) Int J Radiat Oncol Biol Phys , vol.66 , pp. 323-326
    • Hansen, E.K.1    Larson, D.A.2    Aubin, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.