메뉴 건너뛰기




Volumn 66, Issue 2, 2006, Pages 323-326

Image-guided radiotherapy using megavoltage cone-beam computed tomography for treatment of paraspinous tumors in the presence of orthopedic hardware

Author keywords

Image guided radiotherapy; Intensity modulated radiotherapy; Megavoltage cone beam computed tomography; Metastatic spine tumor; Primary spine tumor

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DOSIMETRY; MEDICAL IMAGING; ONCOLOGY; ORTHOPEDICS; TUMORS; VOLTAGE CONTROL;

EID: 33748335530     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2006.05.038     Document Type: Article
Times cited : (48)

References (15)
  • 1
    • 28344436618 scopus 로고    scopus 로고
    • Surgical management of metastatic spine tumors
    • Khan S.N., and Donthineni R. Surgical management of metastatic spine tumors. Orthop Clin N Am 37 (2006) 99-104
    • (2006) Orthop Clin N Am , vol.37 , pp. 99-104
    • Khan, S.N.1    Donthineni, R.2
  • 2
    • 0037310920 scopus 로고    scopus 로고
    • Spinal cord compression
    • Schiff D. Spinal cord compression. Neurol Clin North Am 21 (2003) 67-86
    • (2003) Neurol Clin North Am , vol.21 , pp. 67-86
    • Schiff, D.1
  • 3
    • 23944475575 scopus 로고    scopus 로고
    • The surgical management of primary tumors of the spine
    • Fisher C.G., Keynan O., Boyd M.C., and Dvorak M.F. The surgical management of primary tumors of the spine. Spine 30 (2005) 1899-1908
    • (2005) Spine , vol.30 , pp. 1899-1908
    • Fisher, C.G.1    Keynan, O.2    Boyd, M.C.3    Dvorak, M.F.4
  • 4
    • 0025939587 scopus 로고
    • Tolerance of normal tissue to therapeutic irradiation
    • Emami B., Lyman J., Brown A., et al. Tolerance of normal tissue to therapeutic irradiation. Int J Radiat Oncol Biol Phys 21 (1991) 109-122
    • (1991) Int J Radiat Oncol Biol Phys , vol.21 , pp. 109-122
    • Emami, B.1    Lyman, J.2    Brown, A.3
  • 5
    • 0025283905 scopus 로고
    • The incidence of myelitis after irradiation of the cervical spinal cord
    • Marcus Jr. R.B., and Million R.R. The incidence of myelitis after irradiation of the cervical spinal cord. Int J Radiat Oncol Biol Phys 19 (1990) 3-8
    • (1990) Int J Radiat Oncol Biol Phys , vol.19 , pp. 3-8
    • Marcus Jr., R.B.1    Million, R.R.2
  • 6
    • 12144290705 scopus 로고    scopus 로고
    • Intensity-modulated stereotactic radiotherapy of paraspinal tumors: a preliminary report
    • Bilsky M.H., Yamada Y., Yenice K.M., et al. Intensity-modulated stereotactic radiotherapy of paraspinal tumors: a preliminary report. Neurosurgery 54 (2004) 823-830
    • (2004) Neurosurgery , vol.54 , pp. 823-830
    • Bilsky, M.H.1    Yamada, Y.2    Yenice, K.M.3
  • 7
    • 0036224430 scopus 로고    scopus 로고
    • The effect of titanium stabilization rods on spinal radiation dose
    • Liebross R.H., Starkschall G., Wong P., et al. The effect of titanium stabilization rods on spinal radiation dose. Med Dosim 27 (2002) 21-24
    • (2002) Med Dosim , vol.27 , pp. 21-24
    • Liebross, R.H.1    Starkschall, G.2    Wong, P.3
  • 8
    • 23944461511 scopus 로고    scopus 로고
    • Accurate setup of paraspinal patients using a noninvasive patient immobilization cradle and portal imaging
    • Lovelock D.M., Hua C., Wang P., et al. Accurate setup of paraspinal patients using a noninvasive patient immobilization cradle and portal imaging. Med Phys 32 (2005) 2606-2614
    • (2005) Med Phys , vol.32 , pp. 2606-2614
    • Lovelock, D.M.1    Hua, C.2    Wang, P.3
  • 9
    • 0034816928 scopus 로고    scopus 로고
    • Image-guided hypo-fractionated stereotactic radiosurgery to spinal lesions
    • Ryu S.I., Chang S.D., Kim D.H., et al. Image-guided hypo-fractionated stereotactic radiosurgery to spinal lesions. Neurosurgery 49 (2001) 838-846
    • (2001) Neurosurgery , vol.49 , pp. 838-846
    • Ryu, S.I.1    Chang, S.D.2    Kim, D.H.3
  • 10
    • 3042778361 scopus 로고    scopus 로고
    • CyberKnife frameless stereotactic radiosurgery for spinal lesions: clinical experience in 125 cases
    • Gerszten P.C., Ozhasoglu C., Burton S.A., et al. CyberKnife frameless stereotactic radiosurgery for spinal lesions: clinical experience in 125 cases. Neurosurgery 55 (2004) 89-98
    • (2004) Neurosurgery , vol.55 , pp. 89-98
    • Gerszten, P.C.1    Ozhasoglu, C.2    Burton, S.A.3
  • 11
    • 0037086333 scopus 로고    scopus 로고
    • Investigations of a minimally invasive method for treatment of spinal malignancies with linac stereotactic radiation therapy: accuracy and animal studies
    • Medin P.M., Solberg T.D., De Salles A.A.F., et al. Investigations of a minimally invasive method for treatment of spinal malignancies with linac stereotactic radiation therapy: accuracy and animal studies. Int J Radiat Oncol Biol Phys 52 (2002) 1111-1122
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 1111-1122
    • Medin, P.M.1    Solberg, T.D.2    De Salles, A.A.F.3
  • 13
    • 33748313414 scopus 로고    scopus 로고
    • The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement
    • in press
    • Aubin M., Morin O., Chen J., et al. The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement. Br J Radiol (2006) in press
    • (2006) Br J Radiol
    • Aubin, M.1    Morin, O.2    Chen, J.3
  • 14
    • 0035424531 scopus 로고    scopus 로고
    • Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer
    • Martinez A.A., Di Y., Lockman D., et al. Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer. Int J Radiat Oncol Biol Phys 50 (2000) 1226-1234
    • (2000) Int J Radiat Oncol Biol Phys , vol.50 , pp. 1226-1234
    • Martinez, A.A.1    Di, Y.2    Lockman, D.3
  • 15
    • 33644932630 scopus 로고    scopus 로고
    • Megavoltage cone-beam CT: system description and clinical applications
    • Morin O., Gillis A., Chen J., et al. Megavoltage cone-beam CT: system description and clinical applications. Med Dosim 31 (2006) 51-61
    • (2006) Med Dosim , vol.31 , pp. 51-61
    • Morin, O.1    Gillis, A.2    Chen, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.