메뉴 건너뛰기




Volumn 79, Issue SPEC. ISS., 2006, Pages

Kilovoltage CT using a linac-CT scanner combination

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CANCER RADIOTHERAPY; CANCER RESEARCH; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; GERMANY; HEAD AND NECK CANCER; HUMAN; IMMOBILIZATION; INTENSITY MODULATED RADIATION THERAPY; INTERMETHOD COMPARISON; LINEAR ACCELERATOR; MALIGNANT NEOPLASTIC DISEASE; MATHEMATICAL ANALYSIS; MEDICAL ERROR; PATHOLOGICAL ANATOMY; PATIENT POSITIONING; PROSTATE CANCER; QUANTITATIVE ANALYSIS; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; SPINAL CORD CANCER; TREATMENT OUTCOME; TREATMENT PLANNING; TUMOR LOCALIZATION; TUMOR VOLUME;

EID: 33748940252     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/88849490     Document Type: Article
Times cited : (27)

References (20)
  • 1
    • 0032817892 scopus 로고    scopus 로고
    • Noninvasive patient fixation for extracranial stereotactic radiotherapy
    • Lohr F, et al. Noninvasive patient fixation for extracranial stereotactic radiotherapy. Int J Radiat Oncol Biol Phys 1999;45:521-7.
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 521-527
    • Lohr, F.1
  • 2
    • 0033977805 scopus 로고    scopus 로고
    • Extracranial stereotactic radiation therapy: Set-up accuracy of patients treated for liver metastases
    • Herfarth KK, et al. Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases. Int J Radiat Oncol Biol Phys 2000;46:329-35.
    • (2000) Int J Radiat Oncol Biol Phys , vol.46 , pp. 329-335
    • Herfarth, K.K.1
  • 3
    • 0035989949 scopus 로고    scopus 로고
    • A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    • Groh BA, Siewerdsen JH, Drake DG, Wong JW, Jaffray DA. A performance comparison of flat-panel imager-based MV and kV cone-beam CT. Med Phys 2002;29:967-75.
    • (2002) Med Phys , vol.29 , pp. 967-975
    • Groh, B.A.1    Siewerdsen, J.H.2    Drake, D.G.3    Wong, J.W.4    Jaffray, D.A.5
  • 5
    • 0030176082 scopus 로고    scopus 로고
    • A dual computed tomography linear accelerator unit for stereotactic radiation therapy: A new approach without cranially fixated stereotactic frames
    • Uematsu M, et al. A dual computed tomography linear accelerator unit for stereotactic radiation therapy: a new approach without cranially fixated stereotactic frames. Int J Radiat Oncol Biol Phys 1996;35:587-92.
    • (1996) Int J Radiat Oncol Biol Phys , vol.35 , pp. 587-592
    • Uematsu, M.1
  • 6
    • 0037296854 scopus 로고    scopus 로고
    • A new irradiation unit constructed of self-moving gantry-CT and linac
    • Kuriyama K, et al. A new irradiation unit constructed of self-moving gantry-CT and linac. Int J Radiat Oncol Biol Phys 2003;55:428-35.
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , pp. 428-435
    • Kuriyama, K.1
  • 7
    • 12844261801 scopus 로고    scopus 로고
    • Image-guided radiotherapy for prostate cancer by CT-linear accelerator combination: Prostate movements and dosimetric considerations
    • Wong JR, et al. Image-guided radiotherapy for prostate cancer by CT-linear accelerator combination: prostate movements and dosimetric considerations. Int J Radiat Oncol Biol Phys 2005;61:561-9.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 561-569
    • Wong, J.R.1
  • 8
    • 1642520145 scopus 로고    scopus 로고
    • Commissioning and clinical implementation of a sliding gantry CT scanner installed in an existing treatment room and early clinical experience for precise tumor localization
    • Cheng CW, et al. Commissioning and clinical implementation of a sliding gantry CT scanner installed in an existing treatment room and early clinical experience for precise tumor localization. Am J Clin Oncol 2003;26:e28-e36.
    • (2003) Am J Clin Oncol , vol.26
    • Cheng, C.W.1
  • 9
    • 0035312748 scopus 로고    scopus 로고
    • Three-dimensional accuracy and interfractional reproducibility of patient fixation and positioning using a stereotactic head mask system
    • Karger CP, Jakel O, Debus J, Kuhn S, Hartmann GH. Three-dimensional accuracy and interfractional reproducibility of patient fixation and positioning using a stereotactic head mask system. Int J Radiat Oncol Biol Phys 2001;49:1493-504.
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 1493-1504
    • Karger, C.P.1    Jakel, O.2    Debus, J.3    Kuhn, S.4    Hartmann, G.H.5
  • 10
    • 0000190431 scopus 로고
    • Automated multi-modality image registration based on information theory
    • Collignon A, et al. Automated multi-modality image registration based on information theory. Information Processing in Medical Imaging 1995;262-74.
    • (1995) Information Processing in Medical Imaging , pp. 262-274
    • Collignon, A.1
  • 11
    • 0031221119 scopus 로고    scopus 로고
    • Alignment by maximization of mutual information
    • Viola P, Wells W, III. Alignment by maximization of mutual information. Int J Computer Vision 1997;137-54.
    • (1997) Int J Computer Vision , pp. 137-154
    • Viola, P.1    Wells III, W.2
  • 13
    • 0038605594 scopus 로고    scopus 로고
    • Modern techniques in the radiotherapy of prostate cancer. Non-surgical treatment options for localized stages
    • Didinger B, Schulz-Ertner D, Wannenmacher M, Debus J. [Modern techniques in the radiotherapy of prostate cancer. Non-surgical treatment options for localized stages]. Radiologe 2003;43:448-54.
    • (2003) Radiologe , vol.43 , pp. 448-454
    • Didinger, B.1    Schulz-Ertner, D.2    Wannenmacher, M.3    Debus, J.4
  • 14
    • 13244283350 scopus 로고    scopus 로고
    • Incorporating organ movements in inverse planning: Assessing dose uncertainties by Bayesian inference
    • Unkelbach J, Oelfke U. Incorporating organ movements in inverse planning: assessing dose uncertainties by Bayesian inference. Phys Med Biol 2005;50:121-39.
    • (2005) Phys Med Biol , vol.50 , pp. 121-139
    • Unkelbach, J.1    Oelfke, U.2
  • 15
    • 0142057570 scopus 로고    scopus 로고
    • Adapting inverse planning to patient and organ geometrical variation: Algorithm and implementation
    • Birkner M, Yan D, Alber M, Liang J, Nusslin F. Adapting inverse planning to patient and organ geometrical variation: algorithm and implementation. Med Phys 2003;30:2822-31.
    • (2003) Med Phys , vol.30 , pp. 2822-2831
    • Birkner, M.1    Yan, D.2    Alber, M.3    Liang, J.4    Nusslin, F.5
  • 16
    • 0030061461 scopus 로고    scopus 로고
    • Analysis of prostate and seminal vesicle motion: Implications for treatment planning
    • Beard CJ, et al. Analysis of prostate and seminal vesicle motion: implications for treatment planning. Int J Radiat Oncol Biol Phys 1996;34:451-8.
    • (1996) Int J Radiat Oncol Biol Phys , vol.34 , pp. 451-458
    • Beard, C.J.1
  • 17
    • 33750324194 scopus 로고    scopus 로고
    • Berücksichtigung von interfraktionellen Bewegungen bei der Präzisionsbestrahlung des Prostatakarzinoms - Konsequenzen für Zielvolumina und Dosis-Volumen-Histogramm
    • M.D. Thesis, University of Heidelberg, Germany
    • Didinger B. Berücksichtigung von interfraktionellen Bewegungen bei der Präzisionsbestrahlung des Prostatakarzinoms - Konsequenzen für Zielvolumina und Dosis-Volumen-Histogramm. 2003. M.D. Thesis, University of Heidelberg, Germany.
    • (2003)
    • Didinger, B.1
  • 18
    • 11144279948 scopus 로고    scopus 로고
    • Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy
    • Deurloo KE, et al. Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy. Int J Radiat Oncol Biol Phys 2005;61:228-38.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 228-238
    • Deurloo, K.E.1
  • 19
    • 0141504154 scopus 로고    scopus 로고
    • Near simultaneous computed tomography image-guided stereotactic spinal radiotherapy: An emerging paradigm for achieving true stereotaxy
    • Shin AS, et al. Near simultaneous computed tomography image-guided stereotactic spinal radiotherapy: an emerging paradigm for achieving true stereotaxy. Int J Radiat Oncol Biol Phys 2003;57:605-13.
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 605-613
    • Shin, A.S.1
  • 20
    • 14844283770 scopus 로고    scopus 로고
    • Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes
    • Mohan R, et al. Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes. Int J Radiat Oncol Biol Phys 2005;61:1258-66.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 1258-1266
    • Mohan, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.