메뉴 건너뛰기




Volumn 24, Issue 3, 2004, Pages 296-297

Glucose monitoring for diabeitc patients using icodextrin

Author keywords

[No Author keywords available]

Indexed keywords

EXTRANEAL; GLUCOSE; GLUCOSE OXIDASE; ICODEXTRIN; DIALYSIS FLUID; DRUG DERIVATIVE; GLUCAN; MALTOHEPTAOSE; MALTOHEXAOSE; MALTOPENTAOSE; MALTOSE; MALTOTETROSE; MALTOTRIOSE; OLIGOSACCHARIDE; TRISACCHARIDE;

EID: 2942676862     PISSN: 08968608     EISSN: None     Source Type: Journal    
DOI: 10.1177/089686080402400316     Document Type: Article
Times cited : (8)

References (10)
  • 1
    • 0031761237 scopus 로고    scopus 로고
    • Positive interference of icodextrin metabolites in some enzymatic glucose methods
    • [Letter]
    • Janssen W, Harff G, Caers M, Schellekens A. Positive interference of icodextrin metabolites in some enzymatic glucose methods [Letter]. Clin Chem 1998; 44: 2379-80.
    • (1998) Clin. Chem. , vol.44 , pp. 2379-2380
    • Janssen, W.1    Harff, G.2    Caers, M.3    Schellekens, A.4
  • 2
    • 2942654049 scopus 로고    scopus 로고
    • Interference in blood glucose determination for PD patients on icodextrin (ICO)
    • [Abstract]
    • Dratwa M, Wens R, Tammine M, Tranaeus A. Interference in blood glucose determination for PD patients on icodextrin (ICO) [Abstract]. Perit Dial Int 1998; 18(Suppl 2):S85.
    • (1998) Perit. Dial. Int. , vol.18 , Issue.SUPPL. 2
    • Dratwa, M.1    Wens, R.2    Tammine, M.3    Tranaeus, A.4
  • 3
    • 0032449162 scopus 로고    scopus 로고
    • A previously undescribed side effect of icodextrin: Overestimation of Glycemia by Glucose Analyzer
    • Wens R, Taminne M, Devriendt J, Collart F, Broeders N, Mestrez F, et al. A previously undescribed side effect of icodextrin: overestimation of glycemia by glucose analyzer. Perit Dial Int 1998; 18:603-9.
    • (1998) Perit. Dial. Int. , vol.18 , pp. 603-609
    • Wens, R.1    Taminne, M.2    Devriendt, J.3    Collart, F.4    Broeders, N.5    Mestrez, F.6
  • 4
    • 0034851188 scopus 로고    scopus 로고
    • Important causes of hypoglycaemia in patients with diabetes on peritoneal dialysis
    • Mehmet S, Quan G, Thomas S, Goldsmith D. Important causes of hypoglycaemia in patients with diabetes on peritoneal dialysis. Diabetes UK. Diabet Med 2001; 18:679-82.
    • (2001) Diabetes. UK. Diabet. Med. , vol.18 , pp. 679-682
    • Mehmet, S.1    Quan, G.2    Thomas, S.3    Goldsmith, D.4
  • 5
    • 0141797504 scopus 로고    scopus 로고
    • Spurious hyperglycaemia and icodextrin in peritoneal dialysis fluid
    • Riley SG, Chess J, Donovan KL, Williams JD. Spurious hyperglycaemia and icodextrin in peritoneal dialysis fluid. BMJ 2003; 327:608-9.
    • (2003) BMJ , vol.327 , pp. 608-609
    • Riley, S.G.1    Chess, J.2    Donovan, K.L.3    Williams, J.D.4
  • 6
    • 0343035656 scopus 로고    scopus 로고
    • Direct determination of polyglucose metabolites in plasma using anion-exchange chromatography with pulsed amperometric detection
    • Burke RA, Hvizd MG, Shockley TR. Direct determination of polyglucose metabolites in plasma using anion-exchange chromatography with pulsed amperometric detection. J Chromatogr B Biomed Sci Appl 1997; 693: 353-7.
    • (1997) J. Chromatogr. B. Biomed. Sci. Appl. , vol.693 , pp. 353-357
    • Burke, R.A.1    Hvizd, M.G.2    Shockley, T.R.3
  • 7
    • 0042537406 scopus 로고    scopus 로고
    • Carbohydrates
    • Burtis C, Ashwood ER, eds. 5th ed. New York: WB Saunders Company
    • Sacks DB. Carbohydrates. In: Burtis C, Ashwood ER, eds. Tietz Fundamentals of Clinical Chemistry. 5th ed. New York: WB Saunders Company; 2001: 444-8.
    • (2001) Tietz Fundamentals of Clinical Chemistry , pp. 444-448
    • Sacks, D.B.1
  • 8
    • 2942686434 scopus 로고    scopus 로고
    • Evaluation of potential interference in the blood glucose test kit MediSense Sof Tact with icodextrin and its metabolites
    • McGaw Park, IL: Baxter Study Report; January
    • Skoufos L. Evaluation of potential interference in the blood glucose test kit MediSense Sof Tact with icodextrin and its metabolites. McGaw Park, IL: Baxter Study Report; January, 2002.
    • (2002)
    • Skoufos, L.1
  • 9
    • 0030478428 scopus 로고    scopus 로고
    • Production, characterization, and reconstitution of recombinant quinoprotein glucose dehydrogenase (soluble type; EC 1.1.99.17) apoenzyme of Acinetobacter calcoaceticus
    • Olsthoorn AJJ, Duine JA. Production, characterization, and reconstitution of recombinant quinoprotein glucose dehydrogenase (soluble type; EC 1.1.99.17) apoenzyme of Acinetobacter calcoaceticus. Arch Biochem Biophys 1996; 336:42-8.
    • (1996) Arch. Biochem. Biophys. , vol.336 , pp. 42-48
    • Olsthoorn, A.J.J.1    Duine, J.A.2
  • 10
    • 0022830441 scopus 로고
    • Quinoprotein glucose dehydrogenase and its application in an amperometric glucose sensor
    • D'Costa EJ, Higgins IJ, Turner APF. Quinoprotein glucose dehydrogenase and its application in an amperometric glucose sensor. Biosensors 1986; 2:71-87.
    • (1986) Biosensors , vol.2 , pp. 71-87
    • D'Costa, E.J.1    Higgins, I.J.2    Turner, A.P.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.